EZ Smart 606 User Manual

Page 1
P. 1
Table of Contents
Introduction..........................................................................................................................
About the Product.............................................................................................................
About the EZ Smart-606 Meter....................................................................................
About the EZ Smart-606
About the EZ Smart-606 Test Strip vial..........................................................................
About the Glucode Chip.........................................................................................
Installing/Replacing the battery.....................................................................................
Setting up the Meter............................................................................................................
Coding your EZ Smart-606
Meter...........................................................................................
The Control Solution Test...........................................................................................................
Testing your Blood Glucose Level...........................................................................................
Preparing the Test Strip...................................................................................................
Obtaining a blood sample....................................................................................
Applying blood sample to the EZ Smart-606 Test Strip.........................................................
Memory Features..............................................................................................................
Care and Storage.............................................................................................................
Display Messages.........................................................................................................
Specifications....................................................................................................
Limitations of the Procedure...........................................................................................
Service and Warranty.......................................................................................................
Customer Service............................................................................................................................
2 2 3 4 5 5 6 6 7
8 10 10 11 11 13 14 15 20 21 22 23
P. 2
About the Product
Your EZ Smart-606 System is made up of several components. This booklet is designed to guide you through the operation of the system with detailed directions and pictures.
Introduction
Congratulations on choosing the EZ Smart-606 System, the latest advancement in biosensor technology. Adopted for its ease of use and quick response time, the EZ Smart-606 has the ability to process accurate results utilizing only a small volume of blood for in vitro diagnostics. The EZ Smart-606 Systems intended use is to provide a convenient and safe monitoring system for diabetic individuals. This is an over the counter(OTC) product. Technically, blood glucose is oxidized enzymatically when the electrical current generated by glucose oxidation is measured. The advantage of using the System comes from the EZ Smart- 606 Test Strips, which is specially designed to allow the monitoring of your blood glucose level quickly and easily. What makes the EZ Smart
-606 Test Strip so special is on how blood samples are drawn. Our unique design allows you to use a small amount of blood to produce results in only a short time.
Your EZ Smart-606 System contains:
vEZ Smart-606 Meter vOne vial of EZ Smart-606 Test Strips (10 strips) vOne Glucode Chip (outside the strip vial) vOne Lancing Device (Optional for compact kit) vTen Lancets (Optional for compact kit) vOne carrying case
v vLog book (Optional for compact kit) vQuick Reference Guide vOne vial of Control Solution (Optional for
compact kit)
Note: 25, 50 test strips vial can be purchased individually.
P. 3
About the EZ Smart-606 Meter
5
2
The FRONT
1
2
3
4
8
9
6
7
1. Display Your test results are displayed here.
The large, easy to read screen guides you through the test by using numbers and symbols.
2. M Button
3. S Button
4. Test port This is where you insert the Test
Strip into the Meter.
The BACK
5
5. Battery Cover
6. Unit Switch Switch for mmol/l or mg/dL.
7. Label
8. Reset Button Press this button to re-set
the system.
9. Glucode Chip Insert the Glucode Chip for
coding.
P. 4
About the EZ Smart-606 Test Strip
1
2
3
1
The EZ Smart-606 Test Strip is used to perform the blood glucose test in conjunction with the EZ Smart-606
Meter. Each strip can be used only once.
The EZ Smart-606
Test Strip consists of the following parts:
1.Confirmation Window This is where you can confirm that enough blood has been applied to
the target area.
2.Targ et Ar ea This is where blood is drawn into the EZ Smart-606 Tes t S tr i p.
3.Contact Bar This end of the EZ Smart-606 Test Strip is inserted into the Test Port to activate the
EZ Smart-606 Meter. (white side face up)
3
P. 5
About the EZ Smart-606 Test Strip Vial
EZ Smart-606
Control Solution Range
Code Number Exp. Date
Lot Number
About the Glucode Chip
The Glucode Chip is used to ensure that your EZ Smart-606 Meter provides you with accurate results. Before performing the blood glucose test or starting a new strip vial, please check your
EZ Smart-606 Meter with the Glucode Chip to ensure proper performance (further instructions for use of the Glucode Chip is provided on page 7). After checking your Meter, the Glucode Chip
is also used to code setting.
CODE Number
v Note: Always use the Glucode Chip to ensure your EZ Smart-606 Meter is performing properly. v
DO NOT misplace your Glucode Chip.
P. 6
Installing/Replacing the battery
The EZ Smart-606 Meter uses one 3-Volt lithium battery (CR-2032).
When to Replace the Battery
When the battery is low, the Meter will show a warning signal. When this display appears, it is time to replace a new battery. When the low battery warning signal is shown, the EZ Smart-606 Meter will provide accurate results for approximately 50 more measurements.
How to Replace the Battery
1. From the back of the Meter, gently slide and remove the battery cover.
2. Insert a 3-Volt lithium battery (CR-2032) with the + side facing up.
3. Slide battery cover back into place.
Setting Up the Meter
To turn the Meter on, first pull the plastic tab out from the battery chamber, then press the reset button located at the back of the Meter and proceed with the following instructions.
1. Select unit, mg/dL or mmol/l on the back.
Code Setting and Unit Selection
2. Plug the Glucode Chip into the Glucode Chip slot for strip coding.
P. 7
Coding your EZ Smart-606 Meter
Each batch of EZ Smart-606 Test Strip is encoded with a number that must match one of the code numbers stored in the EZ Smart-606 Meter. In order to ensure an accurate result, the code number on the display must also match the code number found on the EZ Smart-606 Test Strip vial.
1. Insert the EZ Smart-606 Glucode Chip into the Glucode Chip slot. The EZ Smart-606 Meter will automatically be encoded.
Note: Code the EZ Smart-606 Meter whenever you start a new Test Strip vial.
2. All segments of the LCD display will appear indicating that the EZ Smart-606 Meter is functioning properly. Then a beep will sound,
followed by the code number.
3. Match the code number on the EZ Smart-606 Meter display with the code number on the EZ Smart-606 Test Strip vial. If the code matches, you may begin to test.
P. 8
The Control Solution Test
The Control Solution is used to check and ensure that the EZ Smart-606 Meter and EZ Smart-606 Test Strip are working together properly and that you are performing the test correctly. For an accurate reading, check the system with the EZ Smart-606 Control Solution on a routine basis (approximately once a week).
NOTE :
1. Control Solutions are required but not supplied.
2. There are three EZ Smart-606 Control Solutions at different desired range of aqueous glucose (Low, Normal or High). For more information about the EZ Smart-606 Control Solution, Please read your EZ Smart-606 Control Solution package insert. Two sets of control solution should be used, a high level and a low level control solution of your choice.
1. Insert a EZ Smart-606 Tes t S t r ip , white side face up, Contact Bars end first, into the test port. The EZ Smart-606 Meter will auto- matically turn on.
To perform a Control Solution test:
2. All segments of the LCD dis­play will appear, indicating that the EZ Smart-606 Meter is functioning properly.
3. A beep will sound and the code number will appear followed by a flashing
S
symbol. Be sure the code number on the display matches the code number on the
EZ Smart-606 Test Strip vial. If the code numbers do not match, code the EZ Smart-606 Meter by using Glucode Chip, accordingly.
P. 9
4. After the S  symbol appears, press the M button for 3 sec to switch the
ctl symbol. The ctl symbol indicates that the Meter will mark your current test as a Control Solution test. Now you are ready to apply the Control Solution.
5. Discard the first drop of Control Solution and apply a small drop of Control Solution onto your fingertip. Then, place this drop of Control Solution onto the target well area.
6. As soon as enough solution has been drawn into the Confirmation Window, the
EZ Smart-606 Meter will beep and begin counting down from 8 to 1 and the Control Solution test result will appear.
Caution: Please remember that in order to prevent contamination, follow the above instructions for preforming the Control Solution test.
Results falling outside the specified range may be caused by:
v Error in performing the test v Expired or contaminated Control Solution v Expired or contaminated EZ Smart-606
Tes t S t r ip s
v Improper coding of the EZ Smart-606 Meter v EZ Smart-606 Meter malfunction
Comparing Control Solution Results
The EZ Smart-606 is functioning properly if the result falls inside the specified range printed on the Test Strip vial. If the test result falls outside the specified range, repeat the test.
Note: The result will not be stored into the memory and will not be incorporated into the average in the ctl mode. DO NOT use the system if the problem persists.
Please call Tyson Bioresearch, Inc., Customer Services
at
+886-37-585-998 or website of www.tysonbio.com
P. 10
Testing your Blood Glucose Level
Before testing blood glucose, you need the following items:
1. EZ Smart-606 Meter
2. EZ Smart-606 Test Str ip
3. Adjustable Automatic Lancing Device
4. Sterile Lancet
5. Glucode Chip
v Never share a lancing device and lancet with another person. v Always use a new and sterile lancet. Lancets are for single use only. v
Always use a new
EZ Smart-606
Test Strip. Test Strips are for single use only.
v
Do not get lotion, oil, dirt or debris in or on the lancet and lancing device.
Caution: To reduce the chances of infection:
Preparing the Test Strip
1.Wash hands using soap and warm water.Rinse and dry thoroughly.
2.Pull out an EZ Smart-606 Te st
Strip from the vial and re-cap the vial immediately.
3.Insert the Test Strip white side face up, into the test port
.
4. A beep will sound and the code number will appear followed by a flashing S
symbol. Now you are ready to obtain a blood sample.
Reminder: Make sure that the code number on t he display ma tches the code
number displayed on the Test Strip vial. If the code number on the display does not match the code number on the Test Strip vial, code the
Meter by using
Glucode Chip, accordingly.( See page 7)
P. 11
Obtaining a Blood Sample
SAMPLE MAY BE OBTAINED FROM FINGER
For further instructions please see the insert provided with lancing device.
1. Unscrew and remove the endcap of lancing device.
2. Insert the lancet into the lancet holder.
3. Twist and remove the protective lancet cover to expose the sterile needle tip.
4. Recapping and unscrewing the endcap to the body of the lancing device.
5. Pull back on the cocking mechanism until it comes to a stop.
6. Place the lancing device firmly against the finger tip and press the release button.
PERFORM THE TEST
7. After sampling, remove the endcap containing the used lancet carefully.
8. Remove the lancet from the lancing device. Discard the used lancet properly in accordance with
local, state, and federal law.
Applying blood sample to the EZ Smart-606 Test Strip
1. After obtaining a blood sample, place the drop onto the test well of
the EZ Smart-
606 Te st
Strip.
2. Blood is automatically drawn into the EZ
Smart-
606 Test Strip.
Page 2
P. 12
3. As soon as enough blood has filled th e Confirmation Window
(see picture) of the Test Strip,
the EZ Smart-
606 Meter will
beep and begin counting down from 8 to 1.
Confirmation Window
4. Your blood glucose result
will appear on the LCD panel and will be stored into the Meter memory automatically.
Note:To ensure accurate results, make sure the Confir­mation Window of the Test Strip is completely filled with your blood sample.
5. The EZ Smart-606 results range between 20 to 600 mg/dL (1.1 to 33.3 mmol/l). If a HI message appears on your display, your EZ Smart-
606 Meter has detected
that your blood glucose level is higher than 600 mg/dL(33.3 mmol/l). It is suggested that you review your testing procedure and test again with a new EZ Smart-
606
Test Strip to confirm the result. If the same result occurs, consult your
healthcare professional immediately.
6. If a Lo message appears on your display, your EZ Smart-606 Meter has de-
tected that your blood glucose level is lower than 20 mg/dL (1.1 mmol/l). It is suggested that you review your testing procedure and test again with a new EZ
Smart-
606 Test Strip to confirm the result. If the same result occurs, consult
your healthcare professional immediately.
If no further tests are performed, the EZ Smart-606 Meter will automatically shut off after 4 minutes.
P. 13
After finishing the test, we recommend using a tissue paper to remove EZ Smart-
606 Test Strip from the EZ Smart-606 Meter for proper disposal.
Caution: Any change or administer of medication based on the EZ Smart-606 blood glucose test results without the consent advice of a physician or healthcare professional is not recommended.
Memory Features
The EZ Smart-606 Meter automatically stores the 28 most recent blood glucose results. It also provides you with an average of your blood glucose test results.
1. Press the M button to turn on the EZ Smart-
606 Meter.
2. All segments of the LCD display will appear.
3. The 28 set data aver­age will automati­cally appear, and flash for few seconds.
4. The most recent test result(1 st set) will automatically appear.
Press the M button, the Meter displays
the data order release the M botton shows its reading, accordingly. When the 28 memories are full, the oldest result is removed and replaced with the newest result.
P. 14
Exiting the Memory Mode
1. Press and release the M button to the end of the memory(000 will show). Press the S button again to turn the meter off.
2.Meter will shut down automatically after 15 seconds with no further action.
Results marked as ctl (Control Solution) will not be averaged into the nor be stored into the memory.
Care and Storage
1. Handle the EZ Smart-606 Meter with care. Dropping or throwing the Meter may cause dam- age to the device.
2. Do not expose the Meter, Test Strips, and Control Solution to extreme conditions, such as high humidity, heat, freezing cold or dust.
3. Always wash hands with soap and water and rinse and dry completely before handling the Meter and Test Strips.
4. When cleaning the Meter, gently wipe the exterior surface using a damp soft cloth.
DO NOT
USE ANY ORGANIC SOLVENT
for cleaning.
5.
The Meter should be stored at room temperature in a dry and clean space. DO NOT STORE
IN DIRECT SUNLIGHT OR AREAS WITH HIGH HUMIDITY AND/OR DUST.
It is advised
that you store the Meter and its accessories into the provided carrying case.
We have provided a log book for your recording convenience. To learn more about how to record your results, please refer to the log book for further instructions.
P. 15
For healthcare professionals using this system on multiple patients, please be aware that all items that come in contact with human blood should be handled as potential biohazards. Users should follow the guidelines for prevention of blood-borne transmittable diseases in a healthcare setting for potentially infectious human blood specimens as recommended in the National Committee for Clinical Laboratory Standards, Protection of Laboratory Workers from
Instrument Biohazards and Infectious Disease Transmitted by Blood, Body Fluids and Tissue: Approved Guideline.
NCCLS document M29-A [ISBN 1-56238-339-6].
Display Messages
DISPLAY WHAT IT MEANS ACTION
System check verifying that all seg­ments of the Meter are functioning.
This message appears immedi­ately if your Meter has not been encoded.
No Action Necessary
Code Meter (see page 7)
This is the current code number in use.
This code number should match the code number printed on your EZ Smart-
606 Test Strip vial.
P. 16
DISPLAY WHAT IT MEANS ACTION
The system is ready to accept a blood sample.
The system is ready to accept a Con­trol
Solution sample.
EZ Smart-
606 Meter detects blood
glucose level is higher than 600 mg/ dL(33.3 mmol/l).
The EZ Smart-
606 Meter detects
blood glucose level is lower than 20 mg/dL (1.1 mmol/l).
You may now apply a blood sample.
You may now apply a drop of Con­trol Solution sample.
Indicates high blood glucose level. Repeat test. If result still occurs, consult your physician immediately.
Indicates low blood glucose level. Repeat test. If result still occurs, consult your physician immediately.
P. 17
DISPLAY WHAT IT MEANS ACTION
Temperature is too low to perform the test.
Temperature is too high to perform the test.
An error message indicating a problem with the EZ Smart-
606
Test Strip or Glucode Chip.
An error message indicating a problem with the EZ Smart-
606
Meter.
Repeat the test in a warmer setting (10 - 40
o
C or 50 - 104oF). Wait 15
minutes before re-testing.
Repeat the test in a cooler setting (10 - 40
o
C or 50 - 104oF). Wait 15
minutes before re-testing.
Review the instructions and try again with a new EZ Smart-
606 Test
Strip or Glucode Chip.
Check the meter again with the Glucode Chip. If the problem persists, contact Tyson Bioresearch, Inc. Customer Service for help.
P. 18
DISPLAY
WHAT IT MEANS ACTION
Battery power is too low for fur­ther usage.
Battery power is low. Meter will provide approximately 50 more measurements.
All testing values recorded in the memory have been shown.
Replace with a new 3-Volt lithium battery (CR-2032).
Replace with a new 3-Volt lithium battery (CR-2032).
Press S button or wait for 15 sec­onds to turn off the meter.
An error message indicating a prob­lem with the coding of
EZ Smart-
606
Meter.
Check the meter again with the Glucode Chip. If the problem persists, contact Tyson Bioresearch, Inc. Customer Ser­vice for help.
P. 19
Other problems that may occur
ACTION
The EZ Smart-606 Test Strip has not been inserted into the Meter properly.
Review the instructions and re-insert the Test Strip correctly(white side face up).
Defective EZ Smart-606 Test Strip. Replace with a new EZ Smart-606 Te s t
Strip.
Insufficient blood sample.
Repeat the test with new EZ Smart-606 Tes t S t ri p .
Test Strip remains in the test port for more than 4 minutes prior to testing.
Meter will automatically turn-off. Re-insert the Test Strip to the test port.
LCD Screen on the Meter is blank when trying to preform a test.
Contact Tyson Bioresearch, Inc. Customer Service for help.
P. 21
vThe Lancets are in conformity with the MDD 93/42/EEC.
Wuxi Xinda Medical Device Co., Ltd. No.42 Xixin Road, Zhangjing Wuxi, Jiangsu,214194,PRC
+86-510-379-3149
vThe Lancing Device is being clasified as MDD Class I.
Limitations of the Procedure
Caution: The EZ Smart-606 System is designed for in vitro use only and is not intended to test
on newborns.
The EZ Smart-606 Test Strips are designed for use with fresh c apillary whole blood samples.
False results may occur when performing the test while severely dehydrated, severely
hypotensive, in shock or in a hyperglycemic-hyperosmolar state. If you believe you are
suffering from any of the above symptoms, consult a healthcare professional immediately.
EMDAR BV Ijsselburecht 3, Postbus 5486 6802 EL Arnhem, Netherlands +31-263-653-375
Wuxi Xinda Medical Device Co., Ltd. No.42 Xixin Road, Zhangjing Wuxi, Jiangsu,214194,PRC
+86-510-379-3149
EMDAR BV Ijsselburecht 3, Postbus 5486 6802 EL Arnhem, Netherlands +31-263-653-375
P. 22
Service and Warranty
IMPORTANT: The EZ Smart-606 Blood Glucose Monitoring System is designed for in vitro diagnostic use only. Tyson Bioresearch Inc. cannot endorse the performance of the EZ Smart-
606 System when used with Test Strips other than those designed for the EZ Smart-606
Meter. The EZ Smart-606 System manufacturer warranty is valid only when used properly within the guidelines of the provided Users Manual and is invalid when the EZ Smart-
606
System and EZ Smart-606 Test Strip are used improperly.
Manufacturer Warranty:
Tyson Bioresearch, Inc. guarantees that this device will be free of defects in materials and workmanship for a period of three years from the date of original purchase. During the stated three-year period, our company shall repair or replace any EZ Smart-
606 Meter
found defective with a new EZ Smart
-606 Meter.
This warranty does not apply to the performance of a EZ Smart-
606 Meter that has been acciden-
tally damaged, altered, misused, tampered with or abused in any way. In no event shall our company be liable to the purchaser or any other person for any incidental, consequential, or punitive damages arising from or in any way connected with the purchase or operation of the EZ
Smart-
606 Meter or its parts.
For manufacturer warranty services, purchaser must contact Tyson Bioresearch, Inc. for help.
P. 23
Customer Service
If you have any questions or concerns regarding this product and or its operation, or any attempt to correct a problem fails, please call our Customer Service Unit. Our trained specialists will be happy to assist you, train you, or even reaffirm your results.
Customer Service Hotline:
886-37-585998
our office hours are from
8:30am (GMT0030) - 5:30pm (GMT0930)
or E-Mail us at
service@tysonbio.com
When you call our Customer Service Unit, please have your EZ Smart-606 Meter, EZ Smart-606 Test Strip and all other system supplies available. This will allow us to answer any of your ques­tions with speed and efficiency.