Ez One Shot BAR CODE SCANNER User Manual

Default
CHECK VERSION
Version: MAR20041021
DEFAULT
BAR CODE SCANNER USER'S MANUAL
Ez One Shot
CONTENTS
GENERAL
Table of contents
-------
1
Introduction, Ez Troubleshooting
-------
2-3
Cloning Mode
-------
4-5
Getting Started
How to fix the scanner to the terminal
-------
6-9
How to change a cable
-------
9
How to set up the parameter
-------
10
SETTING GROUP
1 Interfaces selection, Computer type, Default
-------
11
2 Reading Mode
-------
12
3
Check Version, Beep tone, Caplock Mode
-------
13
4
Preamble and postamble
-------
14
5
Accuracy adjustment
-------
15
6
Enable and Disable Code ID
-------
16
7 Symbologies Code Identifier,
-------
17
8~9
Set Code ID, Customer Configuration
-------
18-19
10
Delay between block and character
-------
20
11
Terminator & keyboard layout
-------
21
12
RS232: Baud rate, Data bits & parity
-------
22
13
RS232: Stop bit, handshaking, ACK/NAK, Flow Control
-------
23
14
Wand Emulation parameter setting
-------
24
SYMBOLOGY
FORMATTING
( GROUP 15~31)
15 Enable Barcode Symbology
-------
26
16 Disable Barcode Symbology
-------
27
17 China post code ( Toshiba code), Code 32
-------
28
18 UK Plessy code, MSI code
-------
30
19 Code IATA, Code93, Telepen
-------
32
20 Interleaved 2 of 5, Code 11
-------
34
21 Codabar
-------
36
22 ABC Codabar, CX Codabar,
-------
38
23 Codabar Coupling
-------
39
24 Code 128, Standard Code 39, Full ASCII code
39
-------
40
25
Industrial 2 of 5, Matrix 2 of 5
-------
42
26 UPC-E
-------
44
27 UPC-E(0) &(1), UPC-E&UPC-A Expand
-------
45
28 UPC-A
-------
46
29 EAN-8
-------
47
30 EAN-13
-------
48
31 EAN/UCC 128, ISSN, ISBN
-------
49
FULL ASCII (CODE 39 ) TABLE, FUNCTION CODE TABLE
32~39Full ASCII table ( Code 39)
-------
50-57
40 Numeric table
-------
58
41~42Function code table (Code 39) for PC- AT
-------
59-60
43~46Trouble Shooting
-------
61-63
APPENDIX- A
Default
-------
64-66
Cable pinout
-------
67-68
2
GENERAL
INTRODUCTION
This scanner apply with Ez one shot easy programming decoder, It is specially designed to deliver high-end bar code reading performance at the lowest possible price. The scanner utilizes exceptional decoding technology. One-time settings are easily made by scanning set-up bar codes in this handy user's manual. This bar code scanner uses CCD or optical diode technology which does not have moving part, provide ragged reliable quality, enables it suit for any harsh environment conditions. Furthermore, the LED illumination light source of scanner provides less harmful beam to human eyes, and more longer product lifetime.
Notes: ( Please contact your distributor for the detail model number.)
The Ez One shot decoder are mainly apply to the following categories bar code scanner for your reference:
1. Short Range- The reading distance is about from contact to 100mm,
2. Mid Range- The reading distance is about from contact to180mm,
3. Long Range - The reading distance is about from 5mm to 300mm,
4. Wand or Pen bar code scanner.
5. Scan Engine and Fixed Mount scanner .
This scanner has many settings that can be used to conform the unit to the requirements of a particular application. For most usages, however,the default settings programmed into the unit at the factory are appropriate.It is not recommended that the default settings be changed unless thereis a specific need to alter the characteristics of the scanner's performance.
The scanner is easy to install and use. Many problems encountered can be attributed to a wrong setting that has been programmed into the scanner. Before troubleshooting the problem, try this:
1. Unplug the cable from the host computer.
2. Plug the cable back into the host computer.
3. Reset the scanner settings to DEFAULT (Group 1).
If these steps do not resolve the problem, please refer to the troubleshooting table on the next page. If this fails to correct the problem, please consult the troubleshooting section beginning on page 61~63 for further assistance.
EZ TROUBLESHOOTING
. A001$
CLONING MODE
.A018$( Cloning Mode on PC/AT) - you can clone the settings to a PC/AT regardless what kind of device has been chosen on the scanner
. A016$
CLONING MODE
. A018$
CLONING MODE ON- PC/AT
Figure 1
* Format of Cloning :
1st rows >>> ".A017$" ( never edit any data of the first row )
2nd rows >>> "....XXXX" you can adjust the String's Length starting
from the dots"...." forward. The length of the string should
be in 4, 8,12,16 or 20 ( MAX )digits. 3rd rows~ so on >>> XXXX End rows- A dot "." Is an ending of cloning.
XXXX Stand for any String
FORMAT OF CLONINGFORMAT OF CLONING
NOTES:
4
WHAT IS CLONING MODE?
HOW SHOULD CLONING WORK?
CLONING duplicates a wand's settings in other wands. It can save time when a number of wands must be programmed to the same settings.
1. Using this guide, make all the necessary settings for one wand.
2. Scan the CLONING MODE bar code shown below.
3. When CLONING MODE is scanned, all setup parameters will be converted to alphanumeric characters and shown on the monitor.
4. Using a bar code printer, print out all the setup parameters as Code 39 bar code labels.
5. Scan the printed labels sequentially with each wand to be programmed.
1. All cloning strings are upper case.
2. All cloning strings printed on labels should be the same as those on the monitor sequentially from first to last.
3. Cloning mode works in Word Note Pad only.
4. Never edit the data on the first row (.A017$). It is an entry gate for cloning.
5. The cloning string's length can be adjusted by combining multiple strings into one, or by breaking one string to multiple strings starting
from the second row after "....". Length must be in sequences of four,
such as 4,8,12,16,20 (MAX).
6. Be sure to print the dots exactly where they are shown on the monitor.
HOW TO CHANGE A CABLE
The CCD scanner are designed to switch easily between interface options. To switch from one interface to another, the appropriate cable must be installed. To change a cable, simply follow these steps:
1.To release the cable, insert a pin or straightened paper clip into the hole at the base of the scanner where the cable is connected.
2. Remove the cable from the scanner.
3. Plug in the new cable.
After changing to a new cable, be sure to resetthe interface setting as appropriate (including parameter settings for the RS-232 interface).
New Cable
Present cable
New Cable
Present cable
9
USB INTERFACES
The USB Interface supported is compatible with the Apple MAC series,
later PCs and Windows 98, 2000, Me, and XP.
1. Connect the USB cable between the scanner and the computer.
2. The scanner will beep.
3. The Scanner will detect the USB driver automatically. (The first time the scanner is connected via the USB port, follow the appropriate instructions for the host computer.)
4. Set the scanner to KEYBOARD/USB interface by referring to
GROUP-1 (Interface Selections).
5. Scanner will beep to confirm the setting.
6. Scan a bar code to confirm that data shows on the monitor.
How do you program a scanner with this user's guide?
.
RESET
. P023$
HOW TO SET PARAMETERS
1. Use the scanner to scan at the bar code representing the function/ parameter you want to set.
2. When you hear two beeps, the new setting will have been defined or updated into the memory processor.
Default parameters are indicated in bold type and underlined characters. The character font is ARIAL BLACK. CD = Check Digit. CDV = Check Digit Verification.
Most settings require only a single bar code, but a few need several different bar codes to be scanned in order to completely define a setting. They are:
Preamble / Postamble (maximum 16 digits)
MinLength/MaxLength
Accuracy Adjustment
Customer Configuration ID ( Example: Code 39 )
Set A Data - ( CX-Codabar, ABC Codabar, Codabar Coupling).
.
Step 1: Scan CLR PRE/POSTAMBLE. Step 2: Scan PREAMBLE or POSTAMBLE.. Step 3: Scan any alphanumeric from Full ASCII Table in Groups32 - 40. Step 4: Scan PREAMBLE or POSTAMBLE.
Step 1: Scan MIN LENGTH or MAX LENGTH. Step 2: Scan two digits from Appendix 1.
Step 3: Scan MIN LENGTH or MAX LENGTH
Step1: Scan ACCURACY ADJUSTMENT.
Scan one digit from Appendix 1. Scan ACCURACY ADJUSTMENT.
Scan CODE 39 SET ID from Group 8. Scan either one digits or two digits alphanumeric (maximum2 digits)
from Full ASCII table In Groups 32 - 40.
Scan CODE 39 SET ID from Group 8.
Scan SET A DATA. Scan one digits any alphanumeric character from Full ASCII Table in
Groups 32 - 40.
Scan SET A DATA.
Step 2: Step 3:
Step 1: Step 2:
Step 3:
Step1: Step 2:
Step 3:
NOTES:
1. The scanner will beep three times as a reminder that a setting is
not yet complete.
2. If you make a mistake, forget a step, etc., scan CLEAR to start
again.
SETTING BAR CODE
10
. A001$
COMPUTER TYPE
. C007$
NOTEBOOK*
MAC ADB
PC- AT
GROUP-1
INTERFACES SELECTION, COMPUTER TYPE, DEFAULT.
. C001$
KEYBOARD& USB
. C003$
WAND
. C008$
RS485
. C002$
RS232
INTERFACES SELECTION
DEFAULT
Caution: This scanner is designed to switch easily between interface options. To switch from one interface to another, the appropriate cable must be installed. After changing to a new cable, be sure to reset the interface setting as appropriate.
. C006$
. C004$
SYMPTOMS SOLUTION
Scanner seems to be performing as usual, but no data is being output.
1. Unplug the cable from the host computer.
2. Plug the cable back into the host computer.
3. Set the scanner to the exact computer type immediately.
SOLUTION
SYMPTOM
Thewanddoesnot scan/ The scanner does not scan when the trigger is depressed.
1. Unplug the cable from the host computer.
2. Plug the cable back into the host computer.
3. Set the wand to the correct interface. The cable needs to match the interface.
11
Caution:Please ensure the correct computer type is set when the scanner is attached to a new host computer. If set to Notebook, the scanner will operate with no external keyboard.
. A012$
. A013$
. A011$
. A010$
0
1
2
3
4
5
6
7
8
9
. P 023$
RESET
. A014$
. A008$
. A015$
. A009$
4 563987 123453 11421
145287
Preamble 145287
CODE ID AIM ID : ]E0
BARCODE / DATA EAN 13 +5
]E0
OUTPUT : 145287]E0456398712345312411
SYMBOLOGIES
FactoryIDAIM
ID
SYMBOLOGIES
FactoryIDAIM
ID
SYMBOLOGIES CODE ID IDENTIFIER, SET ID
SYMBOLOGIES CODE ID IDENTIFIER
GROUP-7
. B002$
. B003$
. B004$
. B005$
. B006$
. B011$
. B012$
. B013$
. B014$
. B010$
. B001$
. D012$
. D013$
CR+LF
. D014$
TAB
. D015$
. D010$
. D016$
. D011$
. C011$
. C012$
FRENCH
. C013$
. C014$
ITALIAN
. C015$
UNIVERSAL CODE
. C010$
ENGLISH (USA)
. C016$
SWISS
. C018$
. C017$
. C009$
JAPAN
. E010$
. E011$
. E015$
. E014$
. E012$
. E009$
. E013$
. E008$
. E006$
. E001$
. E002$
. E003$
. E004$
. E005$
. E007$
. E022$
. E021$
. E018$
NONE
. E019$
CTS/RTS
. E025$
1Sec
. E026$
3 Sec
. E027$
10 Sec
. E028$
. E023$
ON
. E024$
. E017$
2STOPBITS
. E016$
1STOPBITS
. E020$
Xon/ Xoff
. D002$
600uS
. D004$
HIGH
. D003$
LOW
. D001$
200us
. D005$
. D006$
Bar Low / Space High
. D007$
PEN TYPE
. D008$
FULL ASCII CODE 39
0
1
2
3
4
5
6
7
8
9
. P023$
SETTING PROCEDURE
0
1
2
3
4
5
6
7
8
9
. P023$
SETTING PROCEDURE
0
1
2
3
4
5
6
7
8
9
. P023$
SETTING PROCEDURE
. J 002$
DISABLE
. J 005$
CDV & NOT SEND CDV
. J 004$
CDV & SEND CD
. J 007$
MAX LENGTH ( 48 )
. J 001$
. J 003$
DISABLE CDV
. J 006$
MIN LENGTH ( 6 )
. I 014$
CDV & NOT SEND CD
MIN LENGTH ( 6 )
. I 015$
MAX LENGTH ( 32 )
. I 016$
. I 013$
CDV & SEND CD
DISABLE CDV
. I 012$
DISABLE
. I 011$
ENABLE
. I 010$
. J 008$
. J 009$
. I 042$
. I 043$
. J 014$
0
1
2
3
4
5
6
7
8
9
. P023$
SETTING PROCEDURE
0
1
2
3
4
5
6
7
8
9
. P023$
SETTING PROCEDURE
. I 039$
. I 036$
. I 017$
. I 018$
. I 022$
. I 023$
. I 040$
. I 038$
. I 037$
. I 035$
. I 019$
. I 020$
OFF
. I 026$
. I 041$
. I 021$
SET INSERT DATA*
. I 033$
ON
OFF
. I 034$
0
1
2
3
4
5
6
7
8
9
. P023$
SETTING PROCEDURE
0
1
2
3
4
5
6
7
8
9
. P023$
SETTING PROCEDURE
. H009$
. H008$
. H007$
. H012$
. H010$
. H011$
. H037$
. H038$
. H039$
. H040$
ADD ON SUPPLEMENT
. H047$
ADD A SPACE ON
. H048$
ADD A SPACE OFF
. H056$
ADDENDA REQUIRED ON
. H055$
ADDENDA REQUIRED OFF
. H053$
. H054$
. H063$
. H064$
.H067$
. H068$
. H065$
. H066$
E(1)ON
E(1)OFF
. H069$
. H070$
LEAD DIGIT SEND
. H003$
DISABLE
. H002$
ENABLE
. H001$
. H033$
+5 ON
. H034$
+5OFF
. H035$
+2 ON
. H036$
+2OFF
. H004$
. H005$
CHECK DIGIT SEND
. H006$
. H045$
ADD A SPACE ON
. H046$
ADD A SPACE OFF
. H060$
ADDENDA REQUIRED ON
. H059$
ADDENDA REQUIRED OFF
DISABLE
. H020$
LEAD DIGIT SEND
. H021$
LEAD DIGIT NO SEND
. H022$
CHECK DIGIT NO SEND
. H024$
CHECK DIGIT SEND
. H023$
. H029$
+5ON
. H030$
+5OFF
. H031$
+2ON
. H032$
+2OFF
. H062$
ADDENDA REQUIRED ON
. H061$
ADDENDA REQUIRED OFF
. H043$
ADD A SPACE ON
. H044$
ADD A SPACE OFF
. H019$
ENABLE
47
DISABLE
. H014$
ENABLE
. H013$
LEAD DIGIT SEND
. H015$
. H016$
. H018$
CHECK DIGIT NO SEND
. H017$
CHECK DIGIT SEND
. H025$
. H026$
+ 5 OFF
. H027$
+2ON
. H028$
+ 2 OFF
. H041$
. H042$
. H058$
ADDENDA REQUIRED ON
. H057$
. H052$
. H051$
. H050$
. H049$
. M005$
. M006$
. M007$
. M003$
. M004$
. M001$
. M002$
58
GROUP-40
FULL ASCII NUMERIC TABLE ( CODE 39 )
1
2
3
4
5
6
7
8
9
0
GROUP-42
FUNCTION CODE TABLE ( CODE 39 )
$T U
Tab
$T W
Esc
Page Up
$T S
Up
$T Q
$T Y
BS
$T %K
Del
Right
$T O
$T Z
Ins
Back Tab
$T V
Page Down
$T T
Down
$T R
$T X
Enter
Left
$T P
Rs232 INTERFACE PROBLEMS
Loading...