EZ 2810 Operator Instructions Manual

2810 Shower Panel
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov.
Operator’s Instructions
EZ Way, Inc. PO Box 89 Clarinda, IA 51632 1-800-627-8940 www.ezlifts.com
Form 2-326
Rev. 09/13/18
Table of Content
1. Introduction 2 Intended Use, Product description and Technical specification 3 Safety and control instructions 4 Installation Instructions 5 Features and Controls 6 Operating Procedures
6.1 Showering 9
6.2 Cleaning 10
6.3 Calibrating the cleaning to give a mix of approx. 2% 11
7 Options
7.1 Digital thermometer 12
7.2 Mechanical lock for cleaning liquid bottle 13
8 Routine Maintenance 9 Labels on the 2810 10 Maintenance record 11 Training record
3 4 5 5 8 9
12
14 15 16 17
2
1. Introduction
Dear Customer, Thank you for choosing one of our quality products. We hope you enjoy the 2810 Shower panel.
This manual shall, in conjunction with staff training, ensure that the operator/user is always using and/or operating the 2810 correctly.
The manufacturer requires that each user has read and understands the entire operating manual and that they can apply the instructions as specified. This applies to anyone who was not present at the in-service.
This instruction manual should generally be kept easily accessible for every user. Copying the whole manual is encouraged since its sole purpose is to improve the standard of training and safety.
Please order another copy from us if the instruction manual is lost or unusable, or if it has become illegible over time.
If you require further information or have any questions please do not hesitate to contact EZ Way.
Please make sure you have read, understood and applied the information on the following pages.
3
2. Intended Use, Product Description and Technical Specifications
Intended use:
The 2810 l is a wall mounted Shower Panel.
The patient is typically a person who is unable to take care of their personal hygiene.
The user is any adult person who is capable of reading and understanding the operating manual and is qualified to care for dependent persons/patients.
Before using the 2810, the user must read and understand the operating manual.
The 2810 is intended to be used in a showering area together with the EZ 1000 shower chair and EZ 2000, EZ 3000, EZ 3200, EZ 4000 and EZ 4200 shower trolleys.
Technical Specification
Width 23" Height Depth 5" Recommended mounting
height from floor Min. Dynamic water
pressure Max. Dynamic water
pressure
15"
49"
0,15 Bar
5 Bar
4
3. Safety and Control Instructions
The recommended maintenance procedures will depend on the hardness of your water supply and it is good practice to establish these routine instructions on a weekly basis and then adjust the frequency as your conditions indicate.
Only qualified staff, who understand all
operating and safety procedures may operate the Shower Panel.
Always physically check water temperature
before and during showering and that the thermoscopic mixer functions properly.
Read the separate product manual for
calibrating the thermostat.
Make sure that both valves (2 and 5) on the
front of the Panel are closed after each use.
Make sure that the bottle (8) is filled with
concentrated cleaning detergent before cleaning.
Do not use solvent based cleaning liquids,
iodine based detergent, bromine or methylene blue or a nonabrasive type cleaner.
Do not use any cleaning detergent containing
more than 40 % of alcohol.
After cleaning, rinse with fresh water.
Clean the strainers on the patient and cleaning
shower heads in hot water and rub it with your thumb.
Make sure that hoses, controls, connections and
mixer are free from damages.
Shower Panel should not be used if defects are
noticed. Prompt service is required.
4. Installation Instructions
Plumbing rough - In
All pipes, fittings, backflow preventors, vacuum valves, shut-off valves and connections to panel to be supplied and installed by others to comply with local building and plumbing codes. The manufacturer refers to the European standard EN
1717. To prevent backflow, any bathtub, toilet chair or similar product may not be installed within reach of the patient shower hose.
The patient shower system has a Rada 215-t3 oem thermostat, a main valve on the panel front and a shower handle without on/off trigger.
The Rada 215-t3 oem thermostat has built in filters and check valves and is factory set to give maximum 38 degrees Celsius. The thermostat shall be installed to R15 (½”) cold and hot water supply.
We refer to the enclosed Rada 215-t3 oem thermostat product manual.
The yellow cleaning shower (for cleaning equipment only) has a main safety valve on the panel front and a cleaning handle without on/off trigger.
The cleaning shower shall be installed to a R15 (1/2") cold water supply and if demanded, to a separate “class A tank”.
The concentrated cleaning liquid is preset to give about 2 % mixture in the cleaning shower and the cleaning bottle shall be filled by the cap. See operating manual.
To eliminate pipe debris it is essential that the hot and cold supply pipes are thoroughly flushed before connection to the shower panel.
Recommended mounting height from floor 47".