Eyra AP–180 Instructions For Use Manual

Intelligent pulse battery charger AP-180
INSTRUCTIONS FOR USE
Pulse battery charger AP–180
12V 12A, 24V 6A, 36V 3,6A, 48V 3A, 60V 2,5A
CHARGER CHARACTERISTICS
- Pulsed charge current
- Charger that can "listen" to the chemistry of the battery
- Fast, smooth and battery friendly charging
microprocessor pulse charging system
- 4 charging programs, STA (standard), AGM, GEL, CaCaWET starter battery
- There is no warming up effect, which reduces battery life at overcharge
- 4 charging phase: bulk charge, absorption, equalization, float charge
- Regenerate cells majorly, when they were charged improperly - Battery
desulfatization effect
- Pulse-charging prolong the battery life.
- Safe against short-circuit
- Precise full charge indicator (green LED)
- Working temperature range from 0º to +35ºC
- Charging is independent of oscillations in the supply voltage (PWM
technology)
- START button for completely discharged battery
1
Intelligent pulse battery charger AP-180
CHARGER PARTS
CHARGER OVERVIEW
2
Intelligent pulse battery charger AP-180
INSTRUCTIONS FOR CONNECTING THE CHARGER WITH BATTERY
Battery charger AP-180 is suitable for charging only lead (Pb) batteries from all
together capacity of min. 6Ah (at 12V charger). Maximum capacity of charged battery is not limited. Battery charger is for (we recommend that the charging time is not too long) battery systems up to 200Ah total capacity. Check if charger and battery have the
same voltage!
Charger model:
AP-180 12V AP-180 24V AP-180 36V AP-180 48V AP-180 60V
Minimum battery capacity:
6Ah 3Ah 2Ah 1Ah 1Ah
Plug the charger (230Vac cable) into the mains.
Switch on the main supply switcher (POWER) on back of the charger.
All three LEDs flash briefly, the charger is ready to charge.
BLACK on poll of the battery
RED on + poll of the battery
At correct connection YELLOW LED indicator lights on. The battery is charging.
When the battery is full, GREEN LED indicator lights on.
If the charger does not activate by flashing a yellow LED:
Battery voltage is too low (fully discharged battery) - Press START button for forced charging. The front panel fuse is burn. The fuse on the front panel should be only 15A (for the 12V charger, for the rest of chargers, see the table below).
Charger model:
AP-180 12V AP-180 24V AP-180 36V AP-180 48V AP-180 60V
Front panel fuse:
15A 10A 7,5A 5A 5A
LEGEND OF LED SIGNALS WHILE CHARGING THE BATTERY
LED LED activity Charge phase
battery charge
level
RED, YELLOW, GREEN
short blink all LEDs charger is ready /
YELLOW
blinks bulk charge (Bulk) < 65%
YELLOW
continuously lit absorption I charge (Abso1) 65%...75%
GREEN
blinks absorption II charge (Abso2) 75%...85%
GREEN
2x fast blink equalization charge (Equal) 85%...90%
GREEN
continuously lit float charge (Float) >90%
RED
continuously lit temperature off (Error) /
3
Loading...
+ 5 hidden pages