8.2. Color Adjustment ........................................................................................................... 21
9. Saving of the Adjustment ..................................................................................................... 27
10. Packaging of omniSHAPE ................................................................................................. 28
10.1. Packaging of the screen ............................................................................................. 28
10.2. Packaging of the Base Frame .................................................................................... 29
10.3. Packaging of the accessories ....................................................................................... 31
10.4. Packing all together ....................................................................................................... 31
Page 2
Document Nr.:
Version:
1.Vers. from date:
1.Version from:
Modified from:
Modified at:
Page Nr.
OSH-Manual-EN
1.3
28.02.2012
A. Schutz
A. Schutz
11.05.2012
2 von 33
WARNING
WARNUNG
DANGER
Electrical shock hazard:
Do not open the housing of OSH-E-01 or cleaning the device
before turning the power switch off and unplugging all
connected cables.
Gefahr eines elektrischen Schlages:
Auf keinen Fall das Gehäuse öffnen oder eine Reinigung
durchführen, bevor das Gerät ausgeschaltet ist und alle Kabel
ausgesteckt sind.
Risque de choc électrique:
Ne jamais ouvrir le boîtier ou d'effectuer un nettoyage avant que
l'appareil est éteint et tous les câbles sont débranchés. =>
Ne jamais ouvrir le boîtier ou effectuer un nettoyage avant que
l'appareil ne soit éteint et que tous les câbles sont débranchés.
CAUTION
VORSICHT
GARE
Do not look directly into the projection lens in using any optical
lens, after the screen is removed.
Schauen sie niemals mit Hilfe eines optischen Instruments in
die Projektionslinse, nachdem sie die Scheibe entfernt haben.
Ne regardez jamais à travers un instrument optique dans la
lentille de projection après avoir retiré le disque. => Ne
regardez jamais à travers un instrument optique dans la lentille
de projection après avoir retiré l'écran.
1. Safety Guidelines / Sicherheitsrichtlinien / Directives de sécurité
Page 3
Document Nr.:
Version:
1.Vers. from date:
1.Version from:
Modified from:
Modified at:
Page Nr.
OSH-Manual-EN
1.3
28.02.2012
A. Schutz
A. Schutz
11.05.2012
3 von 33
NOTICE
ACHTUNG
ATTENTION
Do not cover the fan-area of the OSH-E-01. Otherwise it may
result that the device overheats.
Verschließen sie niemals die Lüfter-Bereiche. Andernfalls kann
das Gerät überhitzen.
Ils n'ont jamais fermer les zones de fans. Sinon, l'appareil peut
surchauffer. => Ne jamais couvrir ou obturer les ventilateurs,
risque de surchauffe.
Page 4
Document Nr.:
Version:
1.Vers. from date:
1.Version from:
Modified from:
Modified at:
Page Nr.
OSH-Manual-EN
1.3
28.02.2012
A. Schutz
A. Schutz
11.05.2012
4 von 33
2. Stacking the omniSHAPE
Before starting to build a wall you have to loosen the screws in the corners. If this isn’t done,
the accuracy of the screens flatness won’t be very good.
To build a tower of some omniSHAPES you have to put the first omniSHAPE on a stable
ground. Optional you can use the omniSHAPE Basements.
Make sure that the ground or the basement is in water level.
Page 5
Document Nr.:
Version:
1.Vers. from date:
1.Version from:
Modified from:
Modified at:
Page Nr.
OSH-Manual-EN
1.3
28.02.2012
A. Schutz
A. Schutz
11.05.2012
5 von 33
Then lock the second omniSHAPE on the
first by using a soft-head hammer.
Now you have to lock the latches with a soft-head hammer.
After this you can stack the omniSHAPES. You have to pull the latch of the next
omniSHAPE to the front side.
Stack the second omniSHAPE on the first.
Page 6
Document Nr.:
Version:
1.Vers. from date:
1.Version from:
Modified from:
Modified at:
Page Nr.
OSH-Manual-EN
1.3
28.02.2012
A. Schutz
A. Schutz
11.05.2012
6 von 33
For safety, as shown in the picture, pull the cotter pin into the guiderail
3. Building a concave or convex wall
You can use the connection plate to build walls in different angles. These angles are:
-12°/ -6°/ 0°/ +6°/ +12°
Look below for choosing the right holes for the angle you need.
Page 7
Document Nr.:
Version:
1.Vers. from date:
1.Version from:
Modified from:
Modified at:
Page Nr.
OSH-Manual-EN
1.3
28.02.2012
A. Schutz
A. Schutz
11.05.2012
7 von 33
For example a wall, composed of two omniSHAPES in a +12° angle:
The connection bars on the left and the right side are needed to get the same height,
when stacking the next omniSHAPES on top.
4. Removing the Engine
On the backside of the omniSHAPE you have to release the internal hexagon screws (AllenKey) that are marked in the picture.
Page 8
Document Nr.:
Version:
1.Vers. from date:
1.Version from:
Modified from:
Modified at:
Page Nr.
OSH-Manual-EN
1.3
28.02.2012
A. Schutz
A. Schutz
11.05.2012
8 von 33
Now you have to put your fingers into the handhold pull to remove the OSH-E-01.
Now you can haul the engine out and in.
After removing the Engine you have to remove the cover of the lens.
Page 9
Document Nr.:
Version:
1.Vers. from date:
1.Version from:
Modified from:
Modified at:
Page Nr.
OSH-Manual-EN
1.3
28.02.2012
A. Schutz
A. Schutz
11.05.2012
9 von 33
5. Assembling the Screen
The OSH-CS-480 has an upper and a lower side. The lower side is marked by the serial
number. The upper side is market by a label Oben / Top.
On the backside of the Screen there are 4 screws. You have to unscrew the screws to a
distance of 1cm between the screw head and the frame of the Screen.
You have to clip the screw heads into the keyholes of the screen adapter.
Page 10
Document Nr.:
Version:
1.Vers. from date:
1.Version from:
Modified from:
Modified at:
Page Nr.
OSH-Manual-EN
1.3
28.02.2012
A. Schutz
A. Schutz
11.05.2012
10 von
33
After this you have to fasten the screws at the four positions.
6. Plugging the cables
It’s your choice to connect each omniSHAPE with the single power cable EY-SCHUKOVDE-1,8m or to connect some omniSHAPES together with the Y-cables. Connecting the
power supply is shown by using the Y-cables.
Do only use Y-cables at up to 10 omniSHAPES in one line
It’s not allowed to use the Y-cables in the countries China, Japan, and Korea
Plug the cables as shown in the pictures. When using the Y-cables, make sure that you have
a cable from you main power supply to the first Y-cable. It’s not included.
Notice: The DVI input signal must have a resolution of 1920x1080 pixels @ 50Hz / 60Hz.
For connecting the omniSHAPES to your pc, plug the EYE-RS232-RJ45-1m cable into the
RS232 In slot. If you don’t have this cable, look at the pin configuration below:
Configure the addresses of the omniSHAPES:
Switch on each omniSHAPE by pushing the ON / OFF switch at the backside.
Page 12
Document Nr.:
Version:
1.Vers. from date:
1.Version from:
Modified from:
Modified at:
Page Nr.
OSH-Manual-EN
1.3
28.02.2012
A. Schutz
A. Schutz
11.05.2012
12 von
33
Wall:
To design a wall with the different shapes of screens
Source:
To place a source on the omniSHAPES
Geometry:
To adjust the geometry
Color:
For color adjustment
Components:
To create a complete component list of the things you have to purchase.
7. omniSHAPE Configuration Software
7.1. Start Up of the Software
Copy the folder “omniSHAPES-Designer Release” to a chosen directory of your computer.
Run the executable file:
The main window opens.
Description of symbols:
Page 13
Document Nr.:
Version:
1.Vers. from date:
1.Version from:
Modified from:
Modified at:
Page Nr.
OSH-Manual-EN
1.3
28.02.2012
A. Schutz
A. Schutz
11.05.2012
13 von
33
Preferences:
To set up the connection settings
Service:
Service console for maintenance
Connect:
To connect to the omniSHAPES
Save:
To save the configured settings on the omniSHAPES
Power On:
To power on the chosen omniSHAPES
Standby:
To set the chosen omniSHAPES to standby mode
7.2. Designing a wall
To add a new omniSHAPE you have to choose the screen-shape in the drop down list.
Page 14
Document Nr.:
Version:
1.Vers. from date:
1.Version from:
Modified from:
Modified at:
Page Nr.
OSH-Manual-EN
1.3
28.02.2012
A. Schutz
A. Schutz
11.05.2012
14 von
33
Also you have to choose the Screentype in the drop down list beneath.
Press the to add this omniSHAPE to the wall.
Page 15
Document Nr.:
Version:
1.Vers. from date:
1.Version from:
Modified from:
Modified at:
Page Nr.
OSH-Manual-EN
1.3
28.02.2012
A. Schutz
A. Schutz
11.05.2012
15 von
33
7.3. Connecting to the omniSHAPE
7.3.1. Network connection Settings
For Network usage you can connect the first omniSHAPE by Network, then go on with the
cabling as seen at point 6 ->plugging the cables.
First you have to configure the network settings of your network adapter. Go to the
preferences of internet protocol version 4 (TCP/IPv4) as seen below.
Type in the IP-Address manually as shown below:
Go back to your omniSHAPES Designer Software and press the button Preferences for the
connection settings.
Choose the Network settings and set the IP-address of the omniSHAPE you want to
connect. The standard IP-address is192.168.0.11.
Page 16
Document Nr.:
Version:
1.Vers. from date:
1.Version from:
Modified from:
Modified at:
Page Nr.
OSH-Manual-EN
1.3
28.02.2012
A. Schutz
A. Schutz
11.05.2012
16 von
33
Notice: The connection by network is not as fast as the connection by RS232.
If you want to change the network settings of omniSHAPES, connect your PC to the
omniSHAPES by serial Port. Then choose the omniSHAPE on which you want to adjust the
IP-address, Gateway or Subnet Mask and set it to the values you want by pressing the
button Set to Device.
7.3.2. Serial connection Settings
Press the button Preferences for the connection settings .
You have to do some settings before.
1. Choose the com-Port
2. Choose the baud-rate 115200 baud or 256000 baud.
3. Choose “8N1”
4. Press “Open Serial Port”
Choose on omniSHAPE or the complete wall, after it’s chosen, the color switches from grey to
light purple.
Press Connect to get connected to the omniSHAPE.
After the omniSHAPE Designer is connected the omniSHAPE the color has changed to dark
purple.
Page 17
Document Nr.:
Version:
1.Vers. from date:
1.Version from:
Modified from:
Modified at:
Page Nr.
OSH-Manual-EN
1.3
28.02.2012
A. Schutz
A. Schutz
11.05.2012
17 von
33
Not connected
connected
After being connected to the wall without chosen any omniSHAPE, all will have dark color.
Page 18
Document Nr.:
Version:
1.Vers. from date:
1.Version from:
Modified from:
Modified at:
Page Nr.
OSH-Manual-EN
1.3
28.02.2012
A. Schutz
A. Schutz
11.05.2012
18 von
33
On the picture beside you
can see the background grid
which is seen on the screens
of each omniSHAPE.
Not chosen
omniSHAPE ID:1 is chosen
7.4. Adjusting the Geometry
At the point “Geometry” you can adjust the geometry settings. You have to set the picture
HD_XGA_Grid.bmp which is a content of the main folder of omniSHAPES-Designer. Set it
as the background picture of the source desktop.
To adjust the geometry you first have to choose one omniSHAPE. Click on the symbol
in the main Window.
The omniSHAPE, what you want to adjust has to be chosen.
Here you can see the geometry configuration of the omniSHAPES-Designer.
Adjusting features
Page 19
Document Nr.:
Version:
1.Vers. from date:
1.Version from:
Modified from:
Modified at:
Page Nr.
OSH-Manual-EN
1.3
28.02.2012
A. Schutz
A. Schutz
11.05.2012
19 von
33
Picture
Description
Click inside the box and then use the arrow
keys to adjust the size. Up or right will let the
picture grow, left or down will let the picture
get smaller.
Click inside the box, you could use the
arrow keys to rotate. Press right to rotate the
picture clockwise, press left to rotate the
picture counterclockwise.
Click inside the green center, then use the
arrow keys to move the whole picture
To move the picture faster hold the shift
button on the keyboard while using the
arrow keys
Click inside the rectangles in the corners or
the other exteriors. Then use the arrow keys
to adjust geometry.
IMPORTANT
After adjusting the size or the position you
have to save the settings.
Notice: The settings will only be saved to
the omniSHAPES you have chosen.
Press the save-button to save.
After it’s saved you will see the advice in the
lower side of the program.
Notice: All configuration settings are not stored on the devices automatically. Without
choosing and pressing the save button, all data are lost after power down. After power on
the last saved data are used.
Page 20
Document Nr.:
Version:
1.Vers. from date:
1.Version from:
Modified from:
Modified at:
Page Nr.
OSH-Manual-EN
1.3
28.02.2012
A. Schutz
A. Schutz
11.05.2012
20 von
33
7.5. Mapping
To add a source, press “+” after choosing the resolution.
Now you can move the Source over the omniSHAPE in any position you want to have.
By pressing the Apply Mapping button, the pictures on the chosen omniSHAPE will be
mapped.
To undo the mapping, press Mapping Off, and the mapping will be recessed you find the
button in the geometry settings. To get there press the button on the left.
Page 21
Document Nr.:
Version:
1.Vers. from date:
1.Version from:
Modified from:
Modified at:
Page Nr.
OSH-Manual-EN
1.3
28.02.2012
A. Schutz
A. Schutz
11.05.2012
21 von
33
8. Color adjustment
8.1. Shading correction
To activate the Shading correction, press the button Service at the left side. Then type
“set(0;image_shading_select;1)” into the command line and press “Send”.
Now the Shading image will be loaded. This will need 30 to 40 seconds. After it’s completely
loaded you have to save by pressing the save button .
To deactivate the Shading correction, press the button Service at the left side. Then type
“set(0;image_shading_select;0)” into the command line and press “Send”.
Now the Shading correction has switched off. Now you have to save by choosing the
omniSHAPES and pressing the save button . Otherwise they will be lost after power down.
8.2. Color Adjustment
Press the color adjustment button on the left.
Page 22
Document Nr.:
Version:
1.Vers. from date:
1.Version from:
Modified from:
Modified at:
Page Nr.
OSH-Manual-EN
1.3
28.02.2012
A. Schutz
A. Schutz
11.05.2012
22 von
33
Choose all omniSHAPES (Strg+A) and press the button “Factory Reset” to reset the color
calibration to the factory values. It will take a few minutes until all the omniSHAPES are reset
to the factory values.
After it’s done there will be information in the lower side of the window
Then you have to save the settings, therefore choose the omniSHAPES and press the save
button . Otherwise they will be lost after power down.
Page 23
Document Nr.:
Version:
1.Vers. from date:
1.Version from:
Modified from:
Modified at:
Page Nr.
OSH-Manual-EN
1.3
28.02.2012
A. Schutz
A. Schutz
11.05.2012
23 von
33
Now adjust one omniSHAPE to the color you want to have. Therefore you can adjust the
three values as seen in the picture below.
Now press the button “Apply to Wall” to send the values of this one unit to the whole wall.
After the one omniSHAPE has sent it to all the other omniSHAPES you will see a
in the lower side of the window.
Now the Automatic adjustment is active.
It will take some time (about half an hour) until the whole wall is adjusted automatically.
There might be some omniSHAPES in the wall that are different to the others, then do the
following steps.
Choose the omniSHAPE which you want to adjust and press the button “Enable”.
Page 24
Document Nr.:
Version:
1.Vers. from date:
1.Version from:
Modified from:
Modified at:
Page Nr.
OSH-Manual-EN
1.3
28.02.2012
A. Schutz
A. Schutz
11.05.2012
24 von
33
After pressing the Enable button, the Auto Adjustment switched to Inactive.
Page 25
Document Nr.:
Version:
1.Vers. from date:
1.Version from:
Modified from:
Modified at:
Page Nr.
OSH-Manual-EN
1.3
28.02.2012
A. Schutz
A. Schutz
11.05.2012
25 von
33
Now you can readjust the one unit as seen in the picture below.
After you have done the readjust, press “Apply to Selection”to set it.
After pressing the button, the Auto Adjustment will switch back to Active.
Repeat it again with the other units you want to readjust.
After you waited 20 minutes the wall has auto adjusted automatically.
Then you have to save the settings, therefore choose the omniSHAPES and press the save
button . Otherwise they will be lost after power down.
Page 26
Document Nr.:
Version:
1.Vers. from date:
1.Version from:
Modified from:
Modified at:
Page Nr.
OSH-Manual-EN
1.3
28.02.2012
A. Schutz
A. Schutz
11.05.2012
26 von
33
Sequence Index
Colortemperature / K
Command
1
approx. 6200
set(1;led_seq_index;1)
2
approx. 5700
set(1;led_seq_index;2)
3
approx. 5000
set(1;led_seq_index;3)
4
approx. 4400
set(1;led_seq_index;4)
5
approx. 4200
set(1;led_seq_index;5)
8.3. Color Temperature
You can use these sequence indexes to change the color temperatures.
You can set them in typing the following commands into the command-line:
Then you have to save the settings, therefore choose the omniSHAPES and press the save
button .
Page 27
Document Nr.:
Version:
1.Vers. from date:
1.Version from:
Modified from:
Modified at:
Page Nr.
OSH-Manual-EN
1.3
28.02.2012
A. Schutz
A. Schutz
11.05.2012
27 von
33
Notice: The adjustment will only be
loaded onto the selected Shapes.
Multiple selections are possible.
9. Saving of the Adjustment
To save the adjustment you have to mark the omniSHAPES of which you want to save the
configuration. Therefor you have to mark them. After they’re marked the color switches from
black to purple as seen in the pictures below:
Then press File -> Save Adjustment as… as seen below.
Then choose a filename and save it to the directory you want.
It could be that the omniSHAPE wall looks misaligned after you did some adjustments. Now you
can load the saved adjustment.
Choose the omniSHAPE on which you want to load the saved adjustment, then press File ->
Load Adjustment… as seen below.
Choose the file in which you saved the adjustment, press open and the adjustment is reloaded
again on the unit you have chosen.
Then press the save button to save the adjustment.
Page 28
Document Nr.:
Version:
1.Vers. from date:
1.Version from:
Modified from:
Modified at:
Page Nr.
OSH-Manual-EN
1.3
28.02.2012
A. Schutz
A. Schutz
11.05.2012
28 von
33
10. Packaging of omniSHAPE
10.1. Packaging of the screen
Screw the screws of the screen into the screen frame.
Pack the Screen into the screen protection fleece.
Put the screen into the screen cardboard box.
Close the screen cardboard box with Scotch tape.
Page 29
Document Nr.:
Version:
1.Vers. from date:
1.Version from:
Modified from:
Modified at:
Page Nr.
OSH-Manual-EN
1.3
28.02.2012
A. Schutz
A. Schutz
11.05.2012
29 von
33
10.2. Packaging of the Base Frame
Fix the lens protection cover in front of the lens.
Place the connection plate on the omniSHAPE. Use the T-Position to stack it on the bolts.
Also place the connection bar on the bolts.
Page 30
Document Nr.:
Version:
1.Vers. from date:
1.Version from:
Modified from:
Modified at:
Page Nr.
OSH-Manual-EN
1.3
28.02.2012
A. Schutz
A. Schutz
11.05.2012
30 von
33
Put the rubber foam bars on the bolts.
Put it into the foil bag.
Put it into the Base Frame cardboard box and close the foil bag with some Scotch tape.
Page 31
Document Nr.:
Version:
1.Vers. from date:
1.Version from:
Modified from:
Modified at:
Page Nr.
OSH-Manual-EN
1.3
28.02.2012
A. Schutz
A. Schutz
11.05.2012
31 von
33
Close the Base Frame cardboard box with some Scotch Tape.
10.3. Packaging of the accessories
Pack all the accessories into the accessories cardboard box.
10.4. Packing all together
Put one of the two rubber foams for Base Frame cardboard box into the outer cardboard
box.
Put the Base Frame cardboard box into the rubber foam.
Page 32
Document Nr.:
Version:
1.Vers. from date:
1.Version from:
Modified from:
Modified at:
Page Nr.
OSH-Manual-EN
1.3
28.02.2012
A. Schutz
A. Schutz
11.05.2012
32 von
33
Put the second rubber foam on the Base Frame cardboard box.
Put the rubber foam for screen cardboard box on the screen cardboard box.
Put it into the outer cardboard box.
Page 33
Document Nr.:
Version:
1.Vers. from date:
1.Version from:
Modified from:
Modified at:
Page Nr.
OSH-Manual-EN
1.3
28.02.2012
A. Schutz
A. Schutz
11.05.2012
33 von
33
Put the accessories cardboard box into the outer cardboard box as seen in the picture.
Close the outer cardboard box and tape it with some Scotch tape.
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.