Eye Lighting H573D, H573S Installation & Maintenance

Installation & Maintenance
H573D / H573S
CLASS I, IP65
Installation
The Eye Lighting H573 series’ are floodlights for outdoor (permanent) use, designed to be operated in conjunction with remote control gear appropriate for the lamp type and wattage in use.
The floodlight is designed to be securely mounted on a suitably solid horizontal surface using 2x M16 bolts.
Attach the lamp carrier to the main body by snapping its hinge pin into the cradle on the body.
Screw the lamp in to its full extent, ensuring that it’s secure, but not over tightened.
Ensuring the gasket and joining surfaces are clean, secure the lamp carrier to the main body by pivoting the three screws and tightening the wing nuts evenly.
Incoming supply cables from the control gear are terminated in the termination box via the 20mm threaded entry.
To maintain the integrity of the enclosure’s protection against dust and moisture ingress, cable glands or conduit fittings rated at least IP65 must be used.
Check that the cable glands are tightened correctly. Floodlights must be installed within the maximum
recommended distance to the control gear, as applicable to the type used.
These instructions should be retained by the floodlight owner for reference, and made available as necessary, to ensure future maintenance is carried out correctly.
EL-IM003.00 Page 1 of 2
Aiming
Adjust the horizontal aiming of the floodlight by loosening the anchor and swivel screws (not supplied) fixing the base to the mounting surface. Using the markings on the base plate as a guide, adjust to the required angle and tighten the screws.
Adjust the tilt by loosening the screws at the pivot point and releasing the locking lever. Using the markings on the pivot plate, adjust the floodlight to the required tilt angle and hold in place by tightening the lever. Check the tilt angle is correct and tighten the screws.
General Operation and Maintenance
Failed lamps are to be replaced promptly, or the circuit isolated, to avoid possible control gear damage. Continual operation on supply voltage above that nominated on the control gear will reduce expected lamp and component life.
Clean excessive build up of foreign material from outer surfaces of the body. Clean the lens as required with warm water and mild detergent.
Screws requiring loosening for future service and lamp replacement should be greased for ease of maintenance. Use silicone base grease only, as oil base grease may damage some components.
Luminaires with damaged or cracked glass shall be removed from service immediately.
Continuously operated lamps should be turned off at least once a week for 1 hour.
Lamp Replacement
The floodlight is to be wiped clean of all dust and debris prior to disassembly.
Loosen the three wing nuts and pivot the fixing screws away from the lamp carrier and swing the carrier away from the body.
Replace the lamp only with a type and wattage suitable for the control gear in use. Screw the lamp in to its full extent, ensuring that it’s secure, but not over tightened.
Ensure gasket and joining surfaces are clean, return the lamp carrier to its position and evenly tighten the wing nuts.
H573D/H573S
Max weight = 8.7 kg
Projected Area = 0.22 m
LAMP TABLE
Type Wattage Lamp
M1000LE/BUH
Metal Halide
High
1000W
940W
Pressure Sodium
1000W
Mercury 1000W HF1000PD
MF1000LE/BUH M1000B X/U
MF1000B X/U NH940LX
NH940FLX NH1000
NH1000F
2
For further enquiries, please contact:
Eye Lighting 15 Industrial Ave, Wacol QLD Australia 4076 Tel: (617) 3335 3588 Fax: (617) 3335 3533 Email: info@eli.com.au
EL-IM003.00 Page 2 of 2
Before carrying out any servicing on this luminaire, ensure that the mains supply is fully isolated. High voltages, greater than mains voltage, can be present during
Important – Safety