SETUP and OPERATIONS GUIDE
PLEASE READ THIS GUIDE AND FOLLOW THE STEPS TOWARD SETTING UP THE CAMERA SENSOR IN WORKING MODE.
OPEN THE PACKAGE AND CHECK THAT YOU HAVE THE TOTAL KIT OF PARTS LISTED. SOME ITEMS NOTED ARE NOT
SUPPLIED WITH THE UNIT. THESE INCLUDE : MICROPHONE ATTACHMENT AND THE SPEAKER ATTACHMENT. PLEASE BE
AWARE THAT IT IS UNLAWFUL FOR THE MICROPHONE TO BE USED IN SURVEILLANCE CIRCUMSTANCES IN AUSTRALIA.
EYE CU TECHNOLOGY PTY. LTD. TAKES NO RESPONSIBILITY FOR ANY SUCH USE. ONCE YOU ARE FAMILIAR WITH
EACH PART UNDERTAKE THE ASSEMBLY AS FOLLOWS :
2.1 YOU WILL NEED A PHILLIPS HEAD SCREWDRIVER TO OPEN THE FRONT COVER.
2.2 INSERT THE SD MEMORY CARD
2.3 INSERT THE SIM CARD
2.4 INSERT THE BATTERY PACK
2.5 PLUG IN THE AC/DC POWER ADAPTOR
2.6 CHECK ASSEMBLY & TEST
2.7 TURN POWER ON TO CHARGE BATTERY PACK
YOU WILL THEN BE ABLE TO TEST THE CAMERA SENSOR UNIT, ADD OTHER DEVICES LIKE SMOKE SENSORS,REMOTE’S
ETC. AT THIS POINT YOU WILL NEED TO ACCESS THE WEBSITE AND FOLLOW THE INSTRUCTIONS TO ENABLE YOUR DEVICE TO OPERATE AND TO ACTIVATE THE WARRANTY AND ONGOING OPERATION.
STEP1 FAMILIARISATION
STEP 2 PREPARATION

ONCE YOU HAVE COMMENCED THE BATTERY PACK CHARGE, YOU WILL BE ABLE TO CONNECT (learn in or delete) OTHER SECURITY DEVICES TO THE CAMERA SENSOR. THIS INCLUDES ADDITIONAL PIR’S, SMOKE DETECTORS, REMOTES ETC. THAT HAVE BEEN SUPPLIED WITH YOUR ORDER. THIS WILL ENABLE YOU TO LINK THESE DEVICES TO YOUR SECURITY SYSTEM TO PROVIDE TOTAL SECURITY. YOU ARE ABLE TO ADD OR SUBTRACT DEVICES AT ANY TIME TO EXTEND AND TAYLOR THE SECURITY SYSTEM TO YOUR NEEDS.
STEPS 5-7 PLUG IN THE AC/DC POWER ADAPTOR, CONFIRM WITH POWER ON & CHARGE THE BATTERY
PACK
STEPS 3-4 INSERT THE SIMCARD AND THE BATTERY PACK

STEP 2 PREPARATION
STEPS 8-11 CONFIGURE THE CAMERA SENSOR & ADD OTHER DEVICEs
STEP 12. NOW THAT EVERYTHING IS ASSEMBLED, PLEASE INSTALL THE DEVICES IN THEIR PREFERRED LOCATIONS.
ON COMPLETION GO TO THE WEBSITE—IT SUPPORT
AND FOLLOW THE INSTRUCTIONS FOR REGISTRATION AND
ACTIVATION. YOUR DEVICE SHOULD PROVIDE YOU WITH MANY YEARS OF SECURITY AND SERVICE.

GH-168 CAMERA SENSOR QUICK USER GUIDE

GH-168 CAMERA SENSOR RE-SET PROCEDURE
TXT SUMMARY

GH –168 CAMERA SENSOR DIP SWITCHES
TROUBLESHOOTING PROBLEMS
Q- The unit does not connect to the network.
A – No network coverage (red LED will flash twice) – first check that the Sim Card is
inserted correctly, if so move the unit to another location to establish a connection.
Q- The unit does not communicate with my mobile phone.
A- Check that the Sim Card has enough credit.
Q- The unit does not TXT me that it is armed when auto arm has been set.
A- Check that the correct time and date has been programmed.
Q- The unit only sends a TXT to the second person on the list.
A – Check that the suffix B (for both TXT and Video) has been programmed after the
phone number.
Q- I can’t connect to the camera when I call it.
A- Make sure you are entering the correct password to gain access.
Q – I can’t hear any audio even though I have plugged in a MIC.
A – Check that the MIC is inserted all the way to make a good connection.
Q- I can’t view images or playback video clips from the memory card.
A- Check that you have the appropriate program loaded on your pc to view images
and playback video footage.

1
GH-168 and GH-868 Peripheral Products Specs
Window and Door Sensor GH-951
RF Carrier Frequency: FSK 426.35 / 433.92 / 868.35MHz
RF Communication Range: Up to 250 meters in open space at 25°C
Working Power: 3.0VDC (CR2) Lithium Battery
Battery Life: Up to 3 years with 50 activations each day
External Hardwires Inputs: Normally Open (N.O.) Or Normally Closed (N.C.)
Outdoor Siren GH-952L
RF Carrier Frequency: FSK 426.35 / 433.92 / 868.35MHz
RF Communication Range: Up to 250 meters in open space at 25°C
IP Degree of Protection: 54
Working Power: 10-13.8VDC
Siren Output: 115dB at 1 meter
Power Failure Siren Time: 2, 4, 8 or 16 minute selectable
Power Consumption: 12mA in Standby
200mA in alarming strobe only
400mA in alarming siren & strobe light
Back up Battery: 9VDC Alkaline battery or 6VDC Rechargeable battery
Tamper Protection Output: Normally Close (N.C.), active high, dry relay contact
Siren Activation Inputs: Normally Open (N.O.), active low and Power failure
StrobeActivation Inputs: Normally Open (N.O.), active low
Indoor Siren GH-952S
RF Carrier Frequency: FSK 426.35 / 433.92 / 868.35MHz
RF Communication Range: Up to 250 meters in open space at 25°C
Working Power: 10-13.8VDC
Wireless Numeric Keypad GH-953
RF Carrier Frequency: FSK 426.35 / 433.92 / 868.35MHz
RF Communication Range: Up to 250 meters in open space at 25°C
Working Power: 3.0VDC (CR123A) Lithium Battery
Battery Life: Up to 3 years in standby
Remote Controller GH-954
RF Carrier Frequency: FSK 426.35 / 433.92 / 868.35MHz
RF Communication Range: Up to 250 meters in open space at 25°C
Working Power: 3.0VDC (CR2032) Lithium Battery
Battery Life: Up to 2 years with 50 activations each day
Commands: AWAY, HOME, Off, Panic

2
Smoke Alarm GH-955
RF Carrier Frequency: FSK 426.35 / 433.92 / 868.35MHz
RF Communication Range: Up to 250 meters in open space at 25°C
Working Power: 3.0VDC (CR123A) Lithium Battery
Battery Life: Up to 3 years in standby
Infrared Detector (PIR) GH-957
RF Carrier Frequency: FSK 426.35 / 433.92 / 868.35MHz
RF Communication Range: Up to 250 meters in open space at 25°C
Working Power: 3.0VDC (CR123A) Lithium Battery
PIR Lens: 9m, 101°
Battery Life: Up to 3 years with 50 activations each day
Interchangeable Lens type and Coverage
Repeater / Range Extender GH-958
RF Carrier Frequency: FSK 426.35 / 433.92 / 868.35MHz
RF Communication Range: Up to 250 meters in open space at 25°C
Working Power: 12VDCAdapter
Emergency Helper GH-959
RF Carrier Frequency: FSK 426.35 / 433.92 / 868.35MHz
RF Communication Range: Up to 250 meters in open space at
25°C
Working Power: 3.0VDC (CR2025) Lithium Battery
Battery Life: Up to 3 years in standby