EYC THM86, THM87 Operation Manual

Page 1
[公司地址 ]
THM86/87 Operation Manual
Industrial Multifunction Dew Point Transmitter
V 0.1
Page 2
THM86/87 Industrial Multifunction Dew Point Transmitter Operation manual
Version01
PAGE2 OF 27 Date2017.12.20
Table of Contents
1. Features
2. Security considerations
3. Installation
4. Connection
5. Software operation step
6. Maintenance and exception processing
Page 3
THM86/87 Industrial Multifunction Dew Point Transmitter Operation manual
Version01
PAGE3 OF 27 Date2017.12.20
1.2 Application
Page 4
THM86/87 Industrial Multifunction Dew Point Transmitter Operation manual
Version01
PAGE4 OF 27 Date2017.12.20
Please read this Specification carefully, prior to use of this, and keep the manual properly, for timely reference.
This product can not be used for explosion-proof area. Do not use this product in a situation where human life may be affected. EYC-TECH will not bear any responsibility for the results produced by the operators.
●Installation and wring must be performed by qualified personnel in accordance with all applicable
safety standards.
●This product must be operated under the operating conditions specified in manual to prevent equipment damages.
●This product must be operated under the operating condition specified in this manual to prevent
equipment damages.
●This product must be operated under the normally atmospheric condition to prevent equipment damages.
● To prevent products damage, always disconnect the power supply from the product before
performing any wiring and installation.
● All wiring must comply with local codes of indoor wiring and electric installation rules.
● Please use crimp type terminal.
● To prevent personal injury, do not touch the moving part of product in operation.
● It may cause high humidity atmosphere during the product was breakdown. Please take safety
strategy.
3. Dimension
Page 5
THM86/87 Industrial Multifunction Dew Point Transmitter Operation manual
Version01
PAGE5 OF 27 Date2017.12.20
4. Connection
4.1 Analogue Diagram
4.2 RS-485 Diagrams
Page 6
THM86/87 Industrial Multifunction Dew Point Transmitter Operation manual
Version01
PAGE6 OF 27 Date2017.12.20
4.3 Analogue + RS-485 Diagram
Page 7
THM86/87 Industrial Multifunction Dew Point Transmitter Operation manual
Version01
PAGE7 OF 27 Date2017.12.20
Page 8
THM86/87 Industrial Multifunction Dew Point Transmitter Operation manual
Version01
PAGE8 OF 27 Date2017.12.20
1. Free installation programTHS86 UI_F19D.exe Please use installation program when free program doesn’t execute
2. Installation program THS_UI_XXXXXXXX(Date)_F19D(INSTALLER).rar a. Operating System requirements above Windows XP b. Click THS86 UI_F19D
Page 9
THM86/87 Industrial Multifunction Dew Point Transmitter Operation manual
Version01
PAGE9 OF 27 Date2017.12.20
1. Connect product to PC via RS-485 cable
2. Execute F19D UI”
3. Click “Interface > Config”
Page 10
THM86/87 Industrial Multifunction Dew Point Transmitter Operation manual
Version01
PAGE10 OF 27 Date2017.12.20
a.
d.
e.
b.
c.
Page 11
THM86/87 Industrial Multifunction Dew Point Transmitter Operation manual
Version01
PAGE11 OF 27 Date2017.12.20
a. Show value and trend chart of Dew point temperature b. Show “Open Port, Read successful
a.
b.
a.
Page 12
THM86/87 Industrial Multifunction Dew Point Transmitter Operation manual
Version01
PAGE12 OF 27 Date2017.12.20
Use scan function to connect when forgetting the connection information or having more facilities .
1. Connect the product to PC via RS-485 cable
2. Execute “F19D UI”
3. Click “Interface > Config”
Page 13
THM86/87 Industrial Multifunction Dew Point Transmitter Operation manual
Version01
PAGE13 OF 27 Date2017.12.20
5. Click “Scan to execute connection facilities
a.
b.
Page 14
THM86/87 Industrial Multifunction Dew Point Transmitter Operation manual
Version01
PAGE14 OF 27 Date2017.12.20
a.
b.
Page 15
THM86/87 Industrial Multifunction Dew Point Transmitter Operation manual
Version01
PAGE15 OF 27 Date2017.12.20
Page 16
THM86/87 Industrial Multifunction Dew Point Transmitter Operation manual
Version01
PAGE16 OF 27 Date2017.12.20
a. Show values and trend chat Dew point Temperature
a.
b.
a.
Page 17
THM86/87 Industrial Multifunction Dew Point Transmitter Operation manual
Version01
PAGE17 OF 27 Date2017.12.20
Page 18
THM86/87 Industrial Multifunction Dew Point Transmitter Operation manual
Version01
PAGE18 OF 27 Date2017.12.20
a.
b.
c.
Page 19
THM86/87 Industrial Multifunction Dew Point Transmitter Operation manual
Version01
PAGE19 OF 27 Date2017.12.20
Page 20
THM86/87 Industrial Multifunction Dew Point Transmitter Operation manual
Version01
PAGE20 OF 27 Date2017.12.20
Clear the chart records
Change the chart style
Select the OUTPUT channel
Set line color chosen from OUTPUT
Snap chart
Save the data measuring when the system start connecting before clinking the
Export icon
Show/Not show the statement of Y axis
Show/Not show the statement of X axis
Show/Not show the statement of Y secondary axis
Show/ Not show chart
Log/Not log measuring data
Adjust time range of X axis
Adjust time range of Y axis
Page 21
THM86/87 Industrial Multifunction Dew Point Transmitter Operation manual
Version01
PAGE21 OF 27 Date2017.12.20
a. File > Log Interval b. Select time interval of record
Page 22
THM86/87 Industrial Multifunction Dew Point Transmitter Operation manual
Version01
PAGE22 OF 27 Date2017.12.20
a. Log measuring range Save the data measuring when the system start connecting before clinking the Export icon
a-1. Click Display > Export
Page 23
THM86/87 Industrial Multifunction Dew Point Transmitter Operation manual
Version01
PAGE23 OF 27 Date2017.12.20
b-1. Display > Log(OFF)
b-2. Appoint path and Key in file name > save > Log (ON)
1. If file name is some as the path name, the original file will be covered.
2. If logging records exceed 65536, the log file will be split 65536 records each file
which the file name append _NNN and N start from 1.
Page 24
THM86/87 Industrial Multifunction Dew Point Transmitter Operation manual
Version01
PAGE24 OF 27 Date2017.12.20
Page 25
THM86/87 Industrial Multifunction Dew Point Transmitter Operation manual
Version01
PAGE25 OF 27 Date2017.12.20
Page 26
THM86/87 Industrial Multifunction Dew Point Transmitter Operation manual
Version01
PAGE26 OF 27 Date2017.12.20
a. Output selection b. Responding time c. Voltage or current Output d. Voltage or current analog range e. Upper and Lower point of Output
a.
b.
c.
d.
e.
Page 27
THM86/87 Industrial Multifunction Dew Point Transmitter Operation manual
Version01
PAGE27 OF 27 Date2017.12.20
6. Inspection and maintenance