Extron electronics XTP R HWP 201 4K Setup Manual

XTP R HWP 201 4K • Setup Guide
F G
H
I
Wall Stud
Backing Clip
Mounting Screw
Rotate the backing clip out of the way to insert the mud ring into the wall.
XTP R HWP 201 4K
Decorator-style Faceplate
e
The XTP R HWP 201 4K is a single output XTP decorator-style wallplate receiver that can be installed into the provided mud ring or an optional UL Listed metal junction box. This guide provides instructions for an experienced installer to install and connect the XTP R HWP 201 4K.
Throughput, Power, and Control
Input, Control, and Front Panel Features
Connectors
XTP input
A
connector
DC power
B
connector
LAN connector
C
RS-232 and
D
IR Over XTP connector
Analog audio
E
output connector
HDMI output
F
connector
USB configuration
G
connector
HDMI audio switch
H
Reset button
I
B
A
Rear Front
Figure 1. XTP R HWP 201 4K Rear (Left) and Front (Right) Panel Features
Installation
NOTE: If a junction box is required, use a metal box only.
Ensure the installation meets building, electrical, and safety codes. For additional mounting considerations, see the XTP R HWP 201 4K User Guide at www.extron.com. For metal junction boxes, refer to the
manufacturer for additional mounting instructions and considerations.
ATTENTION: Do not mount multiple devices adjacent to each other
in the same metal junction box. Add at least a one gang space between devices.
POWER
12V
0.8 A MAX.
XTP R HWP 201 4K
XTP IN
Screws or Nails
Wall opening is flush with edge of box.
Cable Clamp
E
D
C
AUDIO
LR
OVER XTP
IRRS-232
Tx
Rx Tx RxG
LAN
HDMI
AUDIO
RESET
CONFIG
ON OFF
HDMI OUT
Installing a Junction Box or Mud Ring
Follow the steps below if mounting the XTP R HWP 201 4K in a junction box or mud ring.
Installation site preparation
1. Use a soft pencil to mark guidelines on the mounting surface. For
accuracy, use a template or the mounting enclosure.
NOTE: Install junction boxes against wall studs.
2. Cut a hole in the wall. To avoid making the hole too big, cut inside
the marked lines.
3. If using the mud ring in a wall with insulation inside, remove at least
6 inches of the insulation around the cutout. If a wall stud interferes with removing the insulation, remove as much insulation as possible between the cutout and the wall stud.
4. Test the t by inserting the mud ring or metal junction box into the
hole in the wall. If necessary, enlarge the hole as needed.
Metal junction box or mud ring installation
To install a UL Listed metal junction box (see gure 2), use mounting
screws to fasten the box to a wall stud.
To install the provided mud ring (see gure 3), attach the mounting
screws to the mud ring and loosely attach backing clips to the ends of the screws. Rotate the backing clips so the mud ring ts in the
opening and then tighten them to t snugly against the back of the wall.
e
Signal Output Cable
XTP R HWP 201 4K
Decorator-style Faceplate
Figure 2. Metal Junction Box Installation
Figure 3. Mud Ring Installation
1
Cabling and Mounting the XTP R HWP 201 4K
12345678
RJ-45
Connector
Insert Twisted
Pair Wires
Pins:
Pin
1
2
3
4
5
6
7
8
Wire color
White-green
Green
White-orange
Blue
White-blue
Orange
White-brown
Brown
Wire color
T568A T568B
White-orange
Orange
White-green
Blue
White-blue
Green
White-brown
Brown
Tx/Rx
Pins
Tx
Rx
Rx Tx
IR Device
RS-232 Device
G
G
Tx Rx
G
OVER XTP
RS-232 IR
Tx
Rx
Balanced Audio Output
Unbalanced Audio Output
No Ground Here
Rear panel connections
1. Connect a shielded twisted pair cable between the XTP input connector on the receiver (see figure 1, A on
the previous page) and the XTP output connector on an XTP twisted pair transmitter or XTP matrix switcher.
ATTENTION: Do not connect this connector to a computer data or telecommunications network.
The XTP R HWP 201 4K is compatible with shielded twisted pair (F/UTP, SF/UTP, and S/FTP) cables. Extron recommends using the following practices to achieve full transmission distances up to 330 feet (100 meters) and reduce transmission errors.
Use Extron XTP DTP 24 SF/UTP cable for the best performance. At a minimum, Extron recommends
24 AWG, solid conductor, STP cable with a minimum bandwidth of 400 MHz.
Terminate cables with shielded connectors to the TIA/EIA-T568B standard.
Limit the use of more than two pass-through points, which may include patch points, punch down
connectors, couplers, and power injectors. If these pass-through points are required, use shielded couplers and punch down connectors.
NOTE: When using shielded twisted pair cable in bundles or conduits, consider the following:
Do not exceed 40% ll capacity in conduits.
Do not comb the cable for the rst 20 meters, where cables are straightened, aligned, and secured in tight bundles.
Loosely place cables and limit the use of tie wraps or hook-and-loop fasteners.
Separate twisted pair cables from AC power cables.
2. Power the XTP R HWP 201 4K in one of the following methods:
Connect the provided external power supply to the 2-pole captive screw connector for local 12 V power (see figure 1, B).
Connect an XTP Power Injector to the XTP connection between the receiver and a locally powered XTP transmitter or XTP matrix switcher.
Connect the XTP R HWP 201 4K to an XTP matrix switcher and enable the remote power feature on the XTP matrix switcher.
TIA/EIA-T568B
Pin Wire Color
1 White-orange
2 Orange
3 White-green
4 Blue
5 White-blue
6 Green
7 White-brown
8 Brown
Mounting the XTP R HWP 201 4K to the metal junction box or mud ring
1. Using the provided screws, attach the XTP R HWP 201 4K to the mud ring or metal junction box through the inner screw holes (see
figure 2 or 3 on the previous page).
2. Using the provided screws, attach the faceplate to the XTP R HWP 201 4K through the outer screw holes (see figure 2 or 3).
NOTE: For configuration, control, and firmware upgrades, connect a host device to the USB mini-B connector before attaching the
faceplate (see figure 1, G, and see the XTP R HWP 201 4K User Guide for details).
Front Panel Connections
1. Connect a host device or control LAN or WAN to the LAN RJ-45 connector for pass-through 10/100 Base-T
Ethernet communication (see figure 1, C). This is an Ethernet pass-through port.
2. To pass bidirectional serial, infrared, or other control signals, connect a control device or controllable device
to the RS-232 and IR Over XTP connector (see figure 1, D). Wire the connector as shown to the right.
NOTE: RS-232 and IR data can be transmitted simultaneously.
3. Connect a balanced or unbalanced, stereo
or mono audio output device to the 3.5 mm, 5-pole captive screw connector (see figure 1,
) for 2-channel stereo analog audio. Wire the
E
connector as shown to the right.
4. Connect a digital video display to the female
HDMI connector (see figure 1, F).
Configuration and Control
To congure the receiver, connect a host device to the front panel USB conguration port (see figure 1, G). On the host device, use the Extron XTP software (recommended) or Simple Instruction Set (SISTM) commands via Extron DataViewer (see the XTP R HWP 201 4K User Guide at
www.extron.com for more information).
For information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics, see the
Extron Safety and Regulatory Compliance Guide on the Extron website.
2
Worldwide Headquarters: Extron USA West, 1025 E. Ball Road, Anaheim, CA 92905, 800.633.9876
© 2019 Extron Electronics — All rights reserved. www.extron.com
All trademarks mentioned are the property of their respective owners.
Tip
Ring
Sleeves
Tip
Ring
LR
Tip
Sleeves
Tip
No Ground Here
LR
Do not tin the wires!
68-2908-50 Rev. A
12 18