Extron Electronics XTP DTP 24 User Manual

XTP DTP 24 Plug Kit for XTP DTP 24 Cable • Setup Guide
The Extron Shielded XTP DTP 24 RJ-45 Plug kit terminates XTP DTP 24 shielded twisted pair cable. The plug can accommodate solid and stranded conductors with a diameter in the range of 0.044 to 0.048inch.
The following tools are required to complete a fully shielded cable assembly:
RJ-45 Crimper
Pliers
RJ-45 Tester
Wire Cutter/Stripper
The kit contains connectors and guides and provides a method to complete a fully shielded cable assembly. To terminate XTP DTP 24 shielded twisted pair cable, follow these steps:
1. Optional: Slide a strain relief or heat shrink
over the cable. The strain relief and heat shrink are not included.
2. Strip approximately 1.25 inches (31.8mm) of
the cable jacket from the end of the cable.
3. Remove the foil and mylar shielding (if
present) from the end of the cable.
against the bottom of the cable jacket for grounding purposes (see note in step 11).
NOTE: In the gure at right, the cable is
viewed from beneath, so the wires are in reverse order.
2
Braid Shield
Fold Back Braid
4
1.25"
Foil Shield
5. Separate and untwist the four exposed
twisted pair wires and trim (but do not strip) the wires to 0.8inch (20.3 mm).
6. Arrange and lay at the eight wires in the
correct order to comply with the TIA/EIA 568B wiring standard (see the table at right).
NOTES: Plenum cable does not have a
stripe on the white conductor.
Pin
1
2
3
4
5
6
7 8
5
T568B Wiring
0.80"
T568B
Wire Colors
White/Orange
Orange
White/Green
Blue
White/Blue
Green
White/Brown
Brown
12345678
7. Feed the individual wires, in the correct order,
through the open front face of the plastic guide and out through the individual holes at the other side. The rear of the guide should be seated against the end of the jacket and braid.
8. Cut the wires to 0.6 inch (15.2 mm) as shown
at right.
9. Push the guide up, leaving 0.3 inch of the
wires exposed above the guide (see image at right).
10. Insert the guide and wires into the RJ-45
connector, making sure the wires pass the crimping teeth of the connector.
NOTE: Ensure the wires are in the correct
order (see table on the previous page) and the bottom of the connector is next to the braid shield that was folded under the cable in step 4.
11. Insert the connector into the termination tool
and crimp it to secure the connector to the cable. Use pliers to secure the connector tabs around the cable and the ground.
NOTE: To ensure correct grounding
throughout the cable, the braid shield (folded back in step 4) must make contact with the shielded RJ-45 connector on both ends of the cable.
Heat Shrink Tubing/ Strain Relief (optional)
0.6"
8
0.3"
9
11
NOTE:
Ensure conductors are seated properly under contacts.
Guide
7
10
Front
12. If a strain relief is present, slide it forward to
cover the cable and the rst 0.4inch (10.2 mm) of the RJ-45 connector.
13. Test both ends of the cable for conductivity.
NOTE: If there is a need to re-terminate the
cable, cut off the terminated end of the cable and repeat steps 2 through 12.