Annotator and USP 507
Optional Output Boards • Installation Guide
C
VID
LORES
R-Y/
OUT
R
Y
Y/
B-Y/
G
B
The Extron Annotator and
USP 507 have a series of
optional output boards.
3G/HDSDI
OUT
These boards are:
• Scan converter board • 3G/HD-SDI board • DVI-D board •
Scaler board (with DVI-I). Any one of these boards mounts
DVI-D
OUT
in the optional output slot, above the RGB and MTP ports,
at the rear of the Annotator or USP 507.
For full device operating details, refer to either the
SCALED
DVI-I
OUT
Annotator User Guide or the USP 507 User Guide, both
available at www.extron.com.
Installing a Board in the Annotator or USP 507
1. Turn off the unit, and remove the power cord. Repeat for all connected devices.
2. Remove eight cover-securing screws from the top and three from each side. Slide
the top cover off. Retain the 14 screws.
3. At the rear optional output slot either:
a. Remove the two securing screws a from either side of the blank plate and lift
the plate away. Retain the screws.
NOTE: Re-use the screws to secure
the new output board in
place. Retain the blank plate.
Or,
b. If a board is already installed in the output slot, remove any cables and the two
screws a. Then remove the retaining screw that secures it to the post on the
device motherboard. Carefully lift the board away from the socket. Retain all
the screws.
4. Remove the new board from its box and anti-ESD bag,
holding the board by the front frame or board edge.
5. Turn the board over so the header sockets face up.
Insert the supplied connector pins into all sockets on
the board. Depending on the option card being
installed, the second header may not be present.
6. Turn the board over again so the connector pins are now
facing down. Carefully align the pins with the appropriate
sockets on the unit motherboard, and push the board rmly down into the sockets.
7. Secure the board to the frame with the two retaining screws
the motherboard using either the original or the supplied screw.
8. Replace the cover, securing it with the fourteen screws removed in step 2.
9. Reconnect any input and output devices and connect to the new board.
10. Connect any control devices.
11. Power on the Annotator or USP 507, and all the connected devices.
1 1
C
VID
LORES
R-Y/
OUT
R
RGB/R-Y,Y, B-Y
2
and to the post on
a
Y
Y/
B-Y/
G
B
MTP
1
Header Socket
Continued on side 2.
1
Annotator and USP 507
Optional Output Board • Installation Guide, (continued)
There are four ways to congure the boards: via front panel menus, a software program
(SPPCP), Simple Instruction Set (SIS™) commands, or internal web pages.
Configuring the Boards Using the Front Panel Menu System
To congure the 3G/HD-SDI and DVI-D boards using the front panel menu system, refer
to the relevant device user guide, available at www.extron.com.
The Annotator and the USP 507 have separate
front panel menus for conguring either the scan
converter board or the DVI-I scaler board.
This menu is accessible only after the board has
been installed.
Scan Converter Board and Scaler DVI-I Board
Configuration Menus
1. Press the Menu button repeatedly until either
the relevant Scan Converter Settings menu or
Aux Scaler Conguration menu appears.
2. Press the Next button to reach each
submenu as desired (see the images at right)
and use the front panel adjustment knobs
([ {) to change the settings.
Configuring the Boards Using the Signal
Processing Products Control Program
1. Open the Signal Processing Products
Control Program (SPPCP) on the PC that is
connected to the Annotator or USP 507
via a LAN or an RS-232 port.
2. Connect to the device. A new board relevant
tab (Scan Converter or AUX Scaler)
is now available. Click on the desired tab to
Aux Scaler
Configuration
Next
Resol 1024x768
Refresh 60.00Hz
Rotate to adjust
resolution. Rotate
to adjust refresh rate.
Next
Output Type
RGBHV
Rotate either to
select output type.
Next
Sync Po larity
H neg V neg
Rotate either to
adjust sync polarity
values.
Next
Aspect Ratio
Follow
Rotate either to
select aspect
ratio mode.
Next
Detail
64
Rotate either to
adjust detail level.
Next
Test Pattern
Crop
Rotate either to
select test pattern.
congure the settings.
Scan Converter
Settings
Next
H Size V
2048 2048
Rotate to adjust
H value. Rotate
to adjust V value.
Next
H Center V
2048 2048
Rotate to adjust
H value. Rotate
to adjust V value.
Next
Output Format
S-video/Comp
Rotate either to
select output format.
Next
Output Standard
NTSC
Rotate either to
select output
standard.
Next
Flicker Filter
3
Rotate either to
adjust flicker filter.
Next
H Filter
0
Rotate either to
adjust H filter.
Next
Encoder Filter
0
Rotate either to
adjust encoder filter
NOTE: 3G/HD-SDI and DVI-D output boards are buffered, so resolution and
refresh rates match all other outputs. The output rate must be set to
720p, 1080i, or 1080p to activate the 3G/HD-SDI output.
Refer to the SPPCP Help File for details.
Configuring the Boards Using Internal Web Pages
1. Using a LAN connection, open an Internet browser, enter the IP address of
the unit in the browser address bar, and connect to the unit.
2. Click on the Configuration tab and congure the settings as needed.
Configuring the Boards Using SIS Commands
The boards can also be congured with specic SIS commands. Refer to the Annotator
or USP 507 User Guide at www.extron.com for SIS command listings.
Extron USA Headquarters
+1.800.633.9876 (Inside USA/Canada Only)
© 2012 Extron Electronics — All rights reserved. All trademarks mentioned are the property of their respective owners. www.extron.com
2
Extron USA - West: +1.714.491.1500 FAX: +1.714.491.1517
Extron USA - East: +1.919.863.1794 FAX: +1.919.863.1797
68-1661-60 Rev C 04 12