The Extron TLP Pro 725M is a 7-inch wall mounted capacitive touchscreen touchpanel with a TFT active matrix color LCD screen. The
screen has 1024x600 resolution and 24-bit color depth. It is ideal for any AV application requiring compact touchpanels with exible
mounting options and a fully customizable interface. This guide provides instructions for experienced installers to mount and install
these touchpanels.
Setup Checklist
Get Ready
Download and install the latest version of the following software:
GUI Designer — For designing layouts for Extron TouchLink
Global Configurator
and touchpanel.
®
Professional or Global Configurator Plus — For setting up and conguring the control processor
Toolbelt — Provides device discovery, device information, rmware updates, and conguration of network settings, system
utilities, and user management for TouchLink Pro devices.
Global Scripter
NOTE:All four software programs are available from www.extron.com.
®
— Provides an integrated development environment for Extron control systems programming.
Obtain the following network information from your network administrator:
DHCP status — (on or off). If DHCP is off, you must also obtain:
IP address Subnet mask Gateway
®
Pro touchpanels and third party touch interfaces.
rce.
User name — This can be either admin or user.
Password — By default, this is extron (for either admin or user).
Make a note of the touchpanel MAC address.
Mount and Cable All Devices
ATTENTION:
• Do not power on the touchpanels or control processors until you have read the Attention in the “Rear Panel Features”
section of the TLP Pro 725 Series User Guide or the IPCP Pro User Guide or IPL Pro User Guide.
• Ne branchez pas les écrans tactiles ou les contrôleurs avant d’avoir lu la mise en garde dans la section «Rear Panel
Features » du TLP Pro 725 Series User Guide ou du IPCP Pro User Guide or IPLProUserGuide.
Mount the units. There are several mounting options for TouchLink Pro touchpanels (see Mounting on the next page).
Connect the touchpanel to a Power over Ethernet injector (see figure 5 on page 4).
Connect the power injector to the LAN and power it on (see figure 5).
Set up the Touchpanels for Network Communication
Connect the PC that you are using for setup, the control processor, and the touchpanel to the same Ethernet subnetwork.
Use the Setup Menu (see page 4) or Toolbelt to set the DHCP status and, if necessary, the IP address, subnet mask, gateway,
and related settings for the touchpanel.
Configure the Touchpanels
The GUI Designer Help File, the Global Configurator Help File, and the Toolbelt Help File provide step-by-step instructions and
detailed information. The Global Configurator Help File includes an introduction to the software and sections on how to start a project
and conguration.
Global Scripter provides an Extron-exclusive Python library (ControlScript®) and Global Scripter modules to get you started.
1
Page 2
TLP Pro 725M • Setup Guide (Continued)
NORTH
NORTH
AMERICAN
AMERICAN
MK
Mounting
The TLP Pro 725M can be wall-mounted, either using a UL-listed junction box, an external wall box, or directly into drywall or furniture.
Suitable mounting accessories can be found at www.extron.com.
ATTENTION:
• Do not install the TLP Pro 725M in a re resistant rated wall or partition assembly.
• Ne pas installer le TLP Pro 725M dans un mur résistant au feu ou une cloison.
• All structural steps and electrical installation must be performed by qualied personnel in accordance with local and
national building codes and electrical codes.
• Toute étape structurelle et installation électrique, doit être effectuée par un personnel qualié, conformément aux
codes du bâtiment, aux codes incendie et sécurité, et aux codes électriques, locaux et nationaux.
With a Wall Box or Junction Box
Some local building codes require the touchpanel to be
mounted in a junction box. Junction boxes or wall boxes
must be purchased separately.
With a wall box
1. Install a junction box or wall box (see gure 1,
1
),
following the instructions provided by the manufacturer.
2. Fasten the mounting plate to the wallbox (
2
) with
the provided screws. Use the mounting holes that
are appropriate to the junction box you are using (see
gure 2).
1
TOP
2
3
NOTES: Extron provides:
• Four 3/4" #6-32 Philips pan head screws for
mounting to US junction boxes
• Two 16 mm M 3.5 Philips pan head screws for
mounting to MK junction boxes
• EU junction boxes are usually provided with
their own screws.
3. Run and connect cables to the back of the touchpanel
(see Rear Panel Features on the following page).
4. The mounting plate has four hooks (
corner. Position the touch panel so that the four
mounting slots (see figure 4,D) in the rear of the
), one in each
3
touchpanel align with these hooks.
5. Move the touchpanel inward and downward so that
touchpanel sits securely on the hooks and the tongue
at the bottom of the mounting plate (4) sits in the
groove in the bottom of the touchpanel (see inset,
gure 1, 5).
6. Fasten the touchpanel to the mounting plate with the
lock screw (6).
Without a junction box
If the wall box is not required by local building codes, you
can mount the touchpanel directly into drywall.
1. Place the mounting plate against the wall or furniture
in a suitable location and ensure that it is level. Use the
mounting plate as a template to mark the wall.
2. Cut a hole 3.5 inches (89 mm) wide x 2.0 inches
(51 mm) high to pass cables through the wall.
3. Use the MK slots and drill the two pilot holes
(gure 2). Extron recommends using two Molly bolts or
SnapToggle bolts.
4. Secure the mounting plate to the wall (gure 1,
5. Complete the installation as described in steps 3
through 6 in the previous section.
2
4
4
5
Back View
6
Figure 1. Mounting the TLP Pro 725M with a Junction Box
AMERICAN
EU
3.5" (89 mm)
MK
EU
2.0"
(51 mm)
).
NORTH
AMERICAN
NORTH
e
EU
EU
2
Figure 2. TLP Pro 725M Mounting Plate
Page 3
Front Panel Features
IIJJKK
AABBCCAA
D
D
E
EEE
Figure 3. TLP Pro 725M Front Panel
Motion sensor — Detects motion between three to ve feet from the touchpanel, and at least 15° from the center axis.
A
• When no motion has been detected for a user-dened period of time, the touchpanel enters sleep mode.
• When motion is detected by the sensor, the screen display is restored and active.
Communication LED — Shows the conguration and connection status of the touchpanel:
B
• Unlit during normal operation (the touchpanel is congured and connected to an IP Link Pro control processor).
• Blinks red if the touchpanel has been congured but is not connected to an IP Link Pro control processor.
• Lit solidly red if the touchpanel has not been congured.
The indicator can be toggled between enabled and disabled, using the Setup Menu (see the next page).
Capacitive touchscreen — A 7-inch screen with 1024x600 resolution.
D
Status lights — Two LED light bars, one on either side of the screen, which can be programmed to provide system feedback.
E
• Light red or green• Blink or light continuously
For information about programming these LEDs, see the Global Configurator Help File and Global Scripter Help File.
Rear Panel Features
Product Category
DD
EE
F
F
G
G
D
D
Figure 4. TLP Pro 725M Rear Panel
Menu Button— Activates the setup menu (see Setup Menu on the next page).
A
Reset Button— Pressing the Reset button allows the unit to be reset in any of three different modes (for an overview, see
B
Reset Modes, on the next page).
Reset LED— Provides feedback about the reset status when the user presses the Reset button (see Reset Modes).
C
CCAABB
Menu Button
A
DD
HH
DD
Reset Button
B
Reset LED
C
Mounting Slots (4)
D
Digital Input Monitoring Port
E
LAN/PoE Connector
F
USB Port
G
Rear Panel Status Lights (6)
H
Speaker
I
Slot for Mounting Plate
J
Mounting Screw
K
3
Page 4
TLP Pro 725M • Setup Guide (Continued)
To network switchTo touchpanel
Mounting Slots (see figure 4 on the previous page) — Four, one in each corner. The hooks on the corners of the mounting plate
D
(see figure 1, 3 on page 2) t into these slots for wall mounting.
Digital Input Monitoring Port — This two-pole captive screw port (1 = signal and G = ground) monitors digital input with or
E
without a +5 VDC pull-up.
LAN/PoE Connector — Connect the touchpanel to a PoE power injector (not provided) using a twisted pair cable, terminated
F
with an RJ-45 connector. Connect the power injector to the LAN through a nework switch. An Extron IP Link Pro control
processor must also be connected to the same network as the TouchLink Pro touchpanel.
ATTENTION:
• The TLP Pro 725M is Power over Ethernet (PoE 802.3af, class 3) compliant. Do not power on the touchpanels
or control processors until you have read the Attention in the “Rear Panel Features” section of the TLP Pro 725
Series User Guide or the IPCP Pro User Guide or IPL Pro User Guide.
• Le TLP Pro 725M est compatible avec l’alimentation POE via Ethernet (PoE 802.3af, classe 3). Ne branchez pas
les écrans tactiles ou les contrôleurs avant d’avoir lu la mise en garde dans la section «Rear Panel Features » du
TLP Pro 725 Series User Guide ou du IPCP Pro User Guide or IPLProUserGuide.
100-240V ~ 50-60Hz
NOTE: The TLP Pro 725M is shipped without a power injector. The
power injector must be purchased separately.
Figure 5 shows the Extron XTP PI 100. Your power injector may look
different.
USB Port — Compatible with USB 2.0.
G
Rear Panel Status Lights — Six, three on each side of the panel, which
H
can be programmed to:
• Illuminate red or green in color
• Blink at three different rates or stay continuously lit
For information about programming these LEDs, see the Global Configurator Help File and Global Scripter Help File.
Speaker — A single speaker provides audible feedback for the user.
I
Slot for Mounting Plate — The tongue at the bottom of the mounting plate (see figure 1, 4) ts into this slot, for wall mounting.
J
Mounting Screw — Tightens against the tongue of the mounting plate to secure the touchpanel.
K
0.4A MAX
XTP
XTP PWR
PWR
Figure 5. XTP PI 100 Power Injector
Reset Modes: a Brief Summary
The TLP Pro 725M offers the following reset modes (see the TLP Pro 725 Series User Guide for complete information):
• Use Factory Firmware — With the unit powered off, press and hold the Reset button (see figure 4,
on the previous
B
page) while reapplying power to the unit. Use this mode with Toolbelt software to replace rmware in the event of conicts
arising from uploading a rmware update.
• Reset All IP Settings — Press and hold the Reset button for 6 seconds. After the Reset LED (
) ashes twice, release
C
and momentarily press the Reset button. Use this mode to reset all network settings without affecting user-loaded les.
• Reset to Factory Defaults — Press and hold the Reset button for 9 seconds. After the Reset LED ashes three times,
release and momentarily press the Reset button. Use this mode to return the touchpanel to factory default settings.
Setup Menu
Press the Menu button (figure 4, A) to open the setup menu.
Select any of the ve available screens (Status, Network,
Display, Audio, and Advanced) by pressing the appropriate
button in the navigation bar at the top of the screen (for more
information, see the TLPPro 725 Series User Guide).