TLP Pro 725C Series • Setup Guide
Overview
The Extron TLP Pro 725C is a 7 inch Cable Cubby touchpanel with a ip-up, 1024x600 (WSVGA) LCD touchscreen with
24-bit color depth. The TLP Pro 725C NC is a streamlined version of the touchpanel, with a set of features designed to adhere
to government and military security protocols. Either model is ideal for any AV application requiring a full-size, Cable Cubby
touchpanel with a customizable interface. This guide provides instructions for experienced installers to mount and install the
TLPPro 725C series touchpanels. For more complete instructions, see the TLPPro 725C User Guide, at www.extron.com.
Setup Checklist
Get Ready
Download and install the latest version of the following software:
GUI Designer — For designing layouts for Extron TouchLink
Global Configurator
processor and touchpanel.
®
Professional and Global Configurator Plus — For setting up and conguring the control
Toolbelt — Provides device discovery, device information, rmware updates, and conguration of network settings,
system utilities, and user management for TouchLink Pro devices.
Global Scripter
®
— Provides an integrated development environment for Extron control systems programming.
NOTE: All four software programs are available from www.extron.com.
Obtain the following network information from your network administrator:
DHCP status — (on or off). If DHCP is off, you must also obtain:
IP address Subnet mask Gateway
User name — This can be either admin or user.
Password — By default, this is extron (for either admin or user).
Make a note of the touchpanel MAC address.
Make sure you are familiar with all the included parts and have all the necessary tools (see page 2) for installing the cable
cubby.
®
Pro touchpanels and third party touch interfaces.
Included Parts
Check that all the following parts are included when the touchpanel is received.
8-cable Cable
Pass-through Plate (2)
TLP Pro 725C (1)
Figure 1. Included Parts (and Number Provided)
NOTE: Active or Passive AAPs must be purchased separately (www.extron.com).
3-space
AAP Frame (2)
3/8” Hole Plug (12)1/4” Hole Plug (4)
#6-32 Screw (8)
3-space
Connectivity
Bracket (2)
1

TLP Pro 725C Series • Setup Guide (Continued)
Tools Required for Installation
Phillips Screw Driver
1/4" Hex Nut Driver
Figure 2. Tools required for installation
Safety Glasses
Vacuum Cleaner
Tape Measure
Marking Pen
Mount and Cable All Devices
ATTENTION:
• Do not power on the touchpanels or control processors until you have read the Attention in the “Rear Panel Features”
section of the TLP Pro 725C Series User Guide.
• Ne branchez pas les écrans tactiles ou les contrôleurs avant d’avoir lu la mise en garde dans la section «Rear Panel
Features » du TLP Pro 725C Series User Guide.
Cut a hole in the table (see Step 1 — Cut-out Dimensions and Step 2 — Cut the Surface on page 3).
Run cables to the cable cubby (see Step 3 — Run all Cables on page 4).
Install modules into the Cable Cubby enclosure. Multiple optional modules can be installed in the TLP Pro 725C Cable Cubby
in a variety of congurations. Decide which modules and which conguration best serve your needs. Options include:
• Cable Retractors (see Step 4 — Install Cable Retractors (Optional) on page 4).
• Pass-through Cable Modules (see Step 5 — Assemble Pass-through Cable Module (Optional) on page 4).
• AAP Modules (see Step 6 — Assemble AAP Module (Optional) on page 4).
• Power Modules (see Step 7 — Install Modules on page 5).
Mount the units (see Step 8 — Mounting the Enclosure on page 6).
Connect the touchpanel to a Power over Ethernet injector (see figure 9 on page 7).
Connect the power injector to the LAN and power it on (see figure 9).
Set up the Touchpanels for Network Communication
Connect the PC that you are using for setup, the control processor, and the touchpanel to the same Ethernet subnetwork.
Use the Setup Menu (see page 8) or Toolbelt to set the DHCP status and, if necessary, the IP address, subnet mask,
gateway, and related settings for the touchpanel.
Configure the Touchpanels
The GUI Designer Help File, the Global Configurator Help File, and the Toolbelt Help File provide step-by-step instructions and
detailed information. The Global Configurator Help File includes an introduction to the software and sections on how to start a
project and conguration.
Global Scripter provides an Extron-exclusive Python library (ControlScript®) and Global Scripter modules to get you started.
Mounting
Planning
Before making any cuts, select the best location for the TLPPro 725C.
Ensure that the edge that opens on the lid is oriented correctly.
Ensure there is enough space for all the system cables and components, including cable retractors, if they are to be installed.
The space requirements for retractors are shown in the TLP Pro 725C User Guide, which is available at www.extron.com.
Decide on the method for cutting a hole in the table:
• Hand router and template
• CNC wood router
• Jigsaw and paper template
Verify that you have the correct template or dimensions.
Check all relevant regulations.
Ensure that the installation complies with local, state, and national building and electrical codes.
Ensure that the installation complies with the Americans with Disabilities Act or other accessibility requirements.
2

Product Category
Step 1 — Cut-out Dimensions
ATTENTION:
• The opening in the table for the Cable Cubby should be cut only by licensed and bonded craftspeople. Exercise care to
prevent scarring or damaging the furniture.
• L’ouverture dans la table pour le CableCubby doit être coupée uniquement par un ouvrier détenteur d’une licence. Veillez
à ne pas laisser de marques ni à détériorer le mobilier.
• Use the appropriate metal Extron routing template or refer to the surface cutout dimensions before cutting a hole in the
furniture or other surface. Pay special attention to the direction the unit will face. The connector access side is underlined
(see Using a CNC wood cutter below). Extron is not responsible for miscut mounting holes.
• Utilisez le gabarit de détourage métallique approprié ou reportez-vous aux dimensions de découpe de la surface
indiquées ci-après avant de découper le meuble ou la surface. Faites particulièrement attention à la direction dans
laquelle l’unité sera dirigée. Le côté pour accéder au connecteur est souligné. Extron décline toute responsabilité en cas
d’erreurs de coupe.
• Ensure that the orientation of the Cable Cubby and the hole dimensions are correct before cutting the table.
• Assurez vous que la position du CableCubby et les dimensions du trou soient correctes avant de couper la table.
• Ensure the table surface is at least 0.375 inch (9.5 mm) thick.
• Assurez vous que la surface de la table est au moins 9,5 mm (0,375 pouce) d’épaisseur.
If using a hand router, you should purchase the Extron TLP Pro 725C routing template (see “Installation Routing Templates for
Cable Cubby Series/2 Enclosures” at www.extron.com).
If using a CNC wood router, use the exact cut-out dimensions (see Using a CNC wood cutter below).
If using a reciprocating saw or jigsaw, use the paper cut-out template (available under the Downloads tab on the TLP Pro 725C
page at www.extron.com).
Step 2 — Cut the Surface
CAUTION: Risk of personal injury: Wear safety glasses when operating power equipment.
ATTENTION : Risque de blessure: Portez des lunettes de sécurité lorsque vous utilisez l’équipement électrique.
Be certain the cut is laid out in exactly the desired location and the edge that opens on the lid is correctly oriented. After verifying
and checking dimensions, cut a hole in the surface of the furniture where the enclosure will be installed (see “Preparing the Table”
in the TLP Pro 725C Series User Guide). There are three methods for cutting the hole in the table:
Using a hand router
Recommended method — Use the Extron TLP Pro 725C
routing template (see “Installation Routing Templates for
Cable Cubby Series/2 Enclosures” at www.extron.com).
Refer to the Routing Template User Guide, available at
www.extron.com, to prepare the template and use the
template to cut the hole.
NOTE: The metal routing template must be
purchased separately. It is reusable and should not
be discarded when the installation is complete.
Using a CNC wood cutter
Recommended method — Use the exact cut-out
dimensions:
8.90 +0.00/-0.02 inches W x 7.10 +0.00/-0.02 inches D
(226 +0.0/-0.1 mm W x 180 +0.00/-0.1 mm D)
NOTE: The underlined dimension is the connector or
AAP access side for the unit.
Using a reciprocating saw or jigsaw
Acceptable method — Use the paper cut-out template
(available under the Downloads tab on the TLPPro 725C
product page at www.extron.com).
0
.625 IN OUTSIDE DIAMETER GUIDE BUSHING
0.500 IN CUT DIAME
STANDARD
TER STRAIGHT ROUTER BIT
TLP
USER ACCESS
710CV ROUTER GUIDE - ALL MO
EXTRON ELECTRONICS
12 MM OR 12.7 MM CUT DIAMETER STRAIGHT ROUTER BIT
16 MM O
DELS
UTSIDE DIAMETER GUIDE BUSHING
METRIC
Figure 3. Using a hand router
68-2179-02 Rev. B
eck position and
in the wall.
dimensions, then cut the opening
6. Double ch
where the RWM 2 is being installed.
position on the mounting surface
5. Place the template and mark the
same as those shown.
Make sure the dimensions are the
4. Measure the cutout and template.
DO NOT CUT the gray dotted lines.
along the red line.
(gray) from the template by cutting
3. Remove the surface cut-out area
the page is not scaled.
before printing, and make sure
2. Double-check the print settings,
1. Confirm the product to be installed.
Width = 0.325" (8.3 mm)
Trim Ring Lip
Do not shrink.
Print scale 1:1
Page size: 11" x 17"
R = 0.25" (6.4 mm)
(0.05 cm)
0" (0.00 cm)
0.02"
+ 0.0
AREA
CUT-OUT
SURFACE
Cut-Out Template for the Extron
TLP Pro 720C and TLP Pro 725C
(Do not cut this line.)
Trim Ring Outer Edge
(226 mm)
8.90"
User Access
(180 mm)
7.10"
User Access
Figure 4. Using a reciprocating saw or jigsaw
3