Extron electronics TLP Pro 725C Series Setup Manual

Page 1
TLP Pro 725C Series • Setup Guide
#4-40 Screw (8)
#6 Star Washer (8)
Overview
The Extron TLP Pro 725C is a 7 inch Cable Cubby touchpanel with a ip-up, 1024x600 (WSVGA) LCD touchscreen with 24-bit color depth. The TLP Pro 725C NC is a streamlined version of the touchpanel, with a set of features designed to adhere to government and military security protocols. Either model is ideal for any AV application requiring a full-size, Cable Cubby touchpanel with a customizable interface. This guide provides instructions for experienced installers to mount and install the TLPPro 725C series touchpanels. For more complete instructions, see the TLPPro 725C User Guide, at www.extron.com.
Get Ready
 Download and install the latest version of the following software:
GUI Designer — For designing layouts for Extron TouchLink Global Configurator
processor and touchpanel.
®
Professional and Global Configurator Plus — For setting up and conguring the control
Toolbelt — Provides device discovery, device information, rmware updates, and conguration of network settings,
system utilities, and user management for TouchLink Pro devices.
Global Scripter
®
— Provides an integrated development environment for Extron control systems programming.
NOTE: All four software programs are available from www.extron.com.
 Obtain the following network information from your network administrator:
DHCP status — (on or off). If DHCP is off, you must also obtain:
IP address Subnet mask Gateway
User name — This can be either admin or user.
Password — By default, this is extron (for either admin or user).  Make a note of the touchpanel MAC address.  Make sure you are familiar with all the included parts and have all the necessary tools (see page 2) for installing the cable
cubby.
®
Pro touchpanels and third party touch interfaces.
Included Parts
Check that all the following parts are included when the touchpanel is received.
8-cable Cable
Pass-through Plate (2)
TLP Pro 725C (1)
Figure 1. Included Parts (and Number Provided)
NOTE: Active or Passive AAPs must be purchased separately (www.extron.com).
3-space
AAP Frame (2)
3/8” Hole Plug (12)1/4” Hole Plug (4)
#6-32 Screw (8)
3-space
Connectivity
Bracket (2)
1
Page 2
TLP Pro 725C Series • Setup Guide (Continued)
Tools Required for Installation
Phillips Screw Driver
1/4" Hex Nut Driver
Figure 2. Tools required for installation
Safety Glasses
Vacuum Cleaner
Tape Measure
Marking Pen
Mount and Cable All Devices
ATTENTION:
Do not power on the touchpanels or control processors until you have read the Attention in the “Rear Panel Features”
section of the TLP Pro 725C Series User Guide.
Ne branchez pas les écrans tactiles ou les contrôleurs avant d’avoir lu la mise en garde dans la section «Rear Panel
Features » du TLP Pro 725C Series User Guide.
 Cut a hole in the table (see Step 1 — Cut-out Dimensions and Step 2 — Cut the Surface on page 3).  Run cables to the cable cubby (see Step 3 — Run all Cables on page 4).  Install modules into the Cable Cubby enclosure. Multiple optional modules can be installed in the TLP Pro 725C Cable Cubby
in a variety of congurations. Decide which modules and which conguration best serve your needs. Options include:
Cable Retractors (see Step 4 — Install Cable Retractors (Optional) on page 4).
Pass-through Cable Modules (see Step 5 — Assemble Pass-through Cable Module (Optional) on page 4).
AAP Modules (see Step 6 — Assemble AAP Module (Optional) on page 4).
Power Modules (see Step 7 — Install Modules on page 5).
 Mount the units (see Step 8 — Mounting the Enclosure on page 6).  Connect the touchpanel to a Power over Ethernet injector (see figure 9 on page 7).  Connect the power injector to the LAN and power it on (see figure 9).
Set up the Touchpanels for Network Communication
 Connect the PC that you are using for setup, the control processor, and the touchpanel to the same Ethernet subnetwork.  Use the Setup Menu (see page 8) or Toolbelt to set the DHCP status and, if necessary, the IP address, subnet mask,
gateway, and related settings for the touchpanel.
Configure the Touchpanels
The GUI Designer Help File, the Global Configurator Help File, and the Toolbelt Help File provide step-by-step instructions and detailed information. The Global Configurator Help File includes an introduction to the software and sections on how to start a project and conguration.
Global Scripter provides an Extron-exclusive Python library (ControlScript®) and Global Scripter modules to get you started.
Mounting
Planning
 Before making any cuts, select the best location for the TLPPro 725C.  Ensure that the edge that opens on the lid is oriented correctly.  Ensure there is enough space for all the system cables and components, including cable retractors, if they are to be installed.
The space requirements for retractors are shown in the TLP Pro 725C User Guide, which is available at www.extron.com.
 Decide on the method for cutting a hole in the table:
Hand router and template
CNC wood router
Jigsaw and paper template
 Verify that you have the correct template or dimensions.  Check all relevant regulations.
 Ensure that the installation complies with local, state, and national building and electrical codes.
 Ensure that the installation complies with the Americans with Disabilities Act or other accessibility requirements.
2
Page 3
Product Category
Trim
uterE
(Do not cut
(Do
thisl
this
)
Step 1 — Cut-out Dimensions
ATTENTION:
The opening in the table for the Cable Cubby should be cut only by licensed and bonded craftspeople. Exercise care to
prevent scarring or damaging the furniture.
L’ouverture dans la table pour le CableCubby doit être coupée uniquement par un ouvrier détenteur d’une licence. Veillez
à ne pas laisser de marques ni à détériorer le mobilier.
Use the appropriate metal Extron routing template or refer to the surface cutout dimensions before cutting a hole in the
furniture or other surface. Pay special attention to the direction the unit will face. The connector access side is underlined
(see Using a CNC wood cutter below). Extron is not responsible for miscut mounting holes.
Utilisez le gabarit de détourage métallique approprié ou reportez-vous aux dimensions de découpe de la surface
indiquées ci-après avant de découper le meuble ou la surface. Faites particulièrement attention à la direction dans
laquelle l’unité sera dirigée. Le côté pour accéder au connecteur est souligné. Extron décline toute responsabilité en cas
d’erreurs de coupe.
Ensure that the orientation of the Cable Cubby and the hole dimensions are correct before cutting the table.
Assurez vous que la position du CableCubby et les dimensions du trou soient correctes avant de couper la table.
Ensure the table surface is at least 0.375 inch (9.5 mm) thick.
Assurez vous que la surface de la table est au moins 9,5 mm (0,375 pouce) d’épaisseur.
If using a hand router, you should purchase the Extron TLP Pro 725C routing template (see “Installation Routing Templates for Cable Cubby Series/2 Enclosures” at www.extron.com).
If using a CNC wood router, use the exact cut-out dimensions (see Using a CNC wood cutter below). If using a reciprocating saw or jigsaw, use the paper cut-out template (available under the Downloads tab on the TLP Pro 725C
page at www.extron.com).
Step 2 — Cut the Surface
CAUTION: Risk of personal injury: Wear safety glasses when operating power equipment. ATTENTION : Risque de blessure: Portez des lunettes de sécurité lorsque vous utilisez l’équipement électrique.
Be certain the cut is laid out in exactly the desired location and the edge that opens on the lid is correctly oriented. After verifying and checking dimensions, cut a hole in the surface of the furniture where the enclosure will be installed (see “Preparing the Table” in the TLP Pro 725C Series User Guide). There are three methods for cutting the hole in the table:
Using a hand router
Recommended method — Use the Extron TLP Pro 725C routing template (see “Installation Routing Templates for Cable Cubby Series/2 Enclosures” at www.extron.com). Refer to the Routing Template User Guide, available at
www.extron.com, to prepare the template and use the
template to cut the hole.
NOTE: The metal routing template must be
purchased separately. It is reusable and should not be discarded when the installation is complete.
Using a CNC wood cutter
Recommended method — Use the exact cut-out dimensions:
8.90 +0.00/-0.02 inches W x 7.10 +0.00/-0.02 inches D (226 +0.0/-0.1 mm W x 180 +0.00/-0.1 mm D)
NOTE: The underlined dimension is the connector or
AAP access side for the unit.
Using a reciprocating saw or jigsaw
Acceptable method — Use the paper cut-out template (available under the Downloads tab on the TLPPro 725C product page at www.extron.com).
0
.625 IN OUTSIDE DIAMETER GUIDE BUSHING
0.500 IN CUT DIAME
STANDARD
TER STRAIGHT ROUTER BIT
TLP
USER ACCESS
710CV ROUTER GUIDE - ALL MO
EXTRON ELECTRONICS
12 MM OR 12.7 MM CUT DIAMETER STRAIGHT ROUTER BIT
16 MM O
DELS
UTSIDE DIAMETER GUIDE BUSHING
METRIC
Figure 3. Using a hand router
68-2179-02 Rev. B
eck position and
in the wall.
dimensions, then cut the opening
6. Double ch
where the RWM 2 is being installed.
position on the mounting surface
5. Place the template and mark the
same as those shown.
Make sure the dimensions are the
4. Measure the cutout and template.
DO NOT CUT the gray dotted lines.
along the red line.
(gray) from the template by cutting
3. Remove the surface cut-out area
the page is not scaled.
before printing, and make sure
2. Double-check the print settings,
1. Confirm the product to be installed.
Width = 0.325" (8.3 mm)
Trim Ring Lip
Do not shrink.
Print scale 1:1 Page size: 11" x 17"
R = 0.25" (6.4 mm)
(0.05 cm) 0" (0.00 cm)
0.02"
­+ 0.0
AREA CUT-OUT
SURFACE
Cut-Out Template for the Extron
TLP Pro 720C and TLP Pro 725C
(Do not cut this line.)
Trim Ring Outer Edge
(226 mm)
8.90"
User Access
(180 mm)
7.10"
User Access
Figure 4. Using a reciprocating saw or jigsaw
3
Page 4
TLP Pro 725C Series • Setup Guide (Continued)
1
4
3
Step 3 — Run all Cables
Run all cables necessary to support the AC connector, the cables stored in the cubby, and all planned AAP connectors. Run the cables below the table and through the hole that was cut in Step 2 — Cut the Surface on the previous page. Leave enough slack in the cables to connect or route them before the cubby is installed in the table. Leave enough space under the TLPPro 725C enclosure for the external power supply and connection of AV cables and the network connection.
Step 4 — Install Cable Retractors (Optional)
If required, Extron cable retractors must be purchased separately. It is difcult to mount the Cable Cubby into the table after the retractors have already been installed so Extron recommends installing the empty retractor bracket at this point. The bracket
should be secured using the lowest level of mounting holes inside the touchpanel enclosure.
The retractors should be added to the bracket after Step 8 — Mounting the Enclosure on page 6. For complete information about retractors and how to install them, see the TLP Pro 725C User Guide and Retractors User Guide at www.extron.com.
Step 5 — Assemble Pass-through Cable Module (Optional)
1. Pass the cables through the connectivity module from the bottom (see
gure 5, 1).
2. Insert the cable into the grommet plate (
3. Fill any unused holes with the provided plugs (
4. Attach the grommet plate to the top of the connectivity module, using
four of the provided #4-40 thread forming screws (4).
To secure the pass-through cable module to the Touchpanel enclosure, see
Step 7 — Install Modules on the next page.
2
).
).
3
3
2
Step 6 — Assemble AAP Module (Optional)
If required, AAPs must be purchased separately. Go to
www.extron.com to see the full range of AAPs that are
available.
1. Secure up to three single space AAPs in the AAP Frame,
using the #4-40 nut with captive washer provided with the AAP (gure 6, 1).
If required, ll any unused spaces with blank AAP plates.
2. Insert cables through the bottom of the connectivity
module and connect them to the AAPs (2).
3. Secure the AAP frame to the connectivity module, using
four of the provided #4-40 thread forming screws (3).
To secure the AAP module to the Touchpanel enclosure, see
Step 7 — Install Modules on the next page.
Figure 5. Installing pass-through cable module
AAP
1
AAP Frame
#4-40 Nut with Captive Washer
Figure 6. Assemble the AAP Module
3
Connectivity Module
2
4
Page 5
Step 7 — Install Modules
Secur using four of the pr pan-head mounting scr
Figure 7 shows how to install a power module. The cable pass­through module and AAP module are installed in the same way.
The TLP Pro 725C has three triple spaces available for installing modules. Extron recommends that, if they are installed, retractors should occupy one of the end spaces. There is no prefered order for the power module, cable pass-through module, or AAP module.
If required, power modules must be purchased separately. See the Extron website (www.extron.com) to select a power module that is suitable for your location.
ATTENTION:
For units that are used in North America, only use AC power
modules that are UL Listed Model “Cable Cubby AC Power Module”.
Pour les unités qui sont utilisées en Amérique du Nord, utilisez
seulement les modules d’alimentation secteur qui sont listés UL, modèle « Cable Cubby AC Power Module ».
The unit is not UL Listed if it uses any AC power module other
than Model “Cable Cubby AC Power Module”.
L’unité n’est pas certifiée UL si elle utilise tout autre module
d’alimentation secteur autre que le modèle «Cable Cubby AC Power Module ».
2
e the modules
ovided #6-32
ews and star washers.
Product Category
e
21-525-01LF
21-526-01LF
To install the power, cable pass-through, or AAP modules, follow these instructions.
1. Insert the module into the cable cubby (gure 7,
the mounting holes on the module line up with the holes on the Cable Cubby enclosure.
If you are installing retractors, they should be secured using the lowest level of mounting holes inside the touchpanel enclosure. Cable pass-through, AAP, and power modules can be mounted at at any height.
2. Secure the modules with #6-32 Phillips head screws and star
washers.
CAUTION: Risk of electric shock: To ensure proper
electrical grounding, use the provided grounding screws and star washers.
ATTENTION : Risque de décharge électrique: An
d’assurer une mise à la terre correcte, utilisez les xations de mise à la terre et les rondelles en étoile fournies.
3. (Power module only) Run the cable or conduit to a convenient
junction box. Extron recommends the circuit be attached to a junction box that is directly wired to the main circuit.
). Make sure
1
125V~ 12A MAX TOTAL
Figure 7. Installing a Module
Insert the modules
1
into the Cable Cubby.
5
Page 6
TLP Pro 725C Series • Setup Guide (Continued)
e
e
21
-52
6-0
1
21-525-01LF
21-526-01LF
is rmly seated in the table.
secure the enclosure.
Lever
Locking
Step 8 — Mounting the Enclosure
NOTE: Use the setup menu to congure the touchpanel before installing it (see Setup Menu on page 8). Once the
enclosure is permanently mounted, the Menu button is under the table and may be difcult to access.
To mount the TLP Pro 725C enclosure, follow these instructions:
1. Remove the edge grommet protecting the edges of the trim ring and the plastic lm on the nished surfaces.
ATTENTION:
Do not use isopropyl alcohol or other solvents to clean the Cable Cubby. Strong solvents will ruin some nishes.
Ne pas utiliser de l’alcool isoproprylique ou d’autres solvants pour nettoyer le CableCubby. Les solvants forts
endommageront certaines nitions.
e
NOTE: To lower the side
clamp, turn the lever down, then press and hold the locking plate while sliding down the clamp.
Plate
Rotate the clamp outward and ensure that the lever is down.
Slide the clamp all the
21 3
way up against the bottom of the table.
Ensure the TLP Pro 725C
Rotate the lever up to
Figure 8. Mounting the TLP Pro 725C Enclosure
2. Rotate the side clamps so that they are ush with the body of the enclosure.
3. Carefully lower the enclosure into the hole cut in the table (see Step 2 — Cut the Surface on page 3). Ensure the trimring
is ush with the top of the table.
4. Once the enclosure is in position, rotate the side clamps outward (one on each side). Ensure the lever is pointing down (see
gure 8, 1).
5. Slide the side clamps up until they are rmly against the bottom of the table (
6. With the enclosure rmly seated, raise the levers to secure the TLP Pro 725C in place on both sides.
7. Use cable ties to secure cables under the table to prevent them becoming tangled.
2
).
6
Page 7
Product Category
To network switchTo touchpanel
Step 9 — Connecting the TLP Pro 725C
The TLP Pro 725C is Power over Ethernet compliant and must be powered through the LAN/PoE port (see figure 11, A, on the next page). Extron recommends the Extron XTP PI 100 power injector. Your power injector may look different.
An Extron IP Link Pro control processor must also be connected to the same network as the TouchLink Pro touchpanel.
ATTENTION:
Do not power on the touchpanel until you have read the Attention in the “Base Features” section of the TLP Pro 725C
Series User Guide.
Ne branchez pas l’écran tactile avant d’avoir lu la mise en garde dans la section «Base Features » du TLP Pro 725C Series
User Guide.
1. Connect the touchpanel to a PoE power injector (not provided) using a
twisted pair cable, terminated with an RJ-45 connector (see gure 9, 1).
2. Connect the power injector to the LAN through a network switch (
Front Panel Features
LCD screen — The TLP Pro 725C series has a 7-inch
A
screen with a 1024x600 resolution.
Motion sensor — Detects motion between three to ve feet
B
from the touchpanel, and at least 15° from the center axis.
When no motion has been detected for a user-dened
period of time, the touchpanel enters sleep mode.
When motion is detected by the sensor, the screen
display is restored and active.
Communication LED — This LED shows the conguration
C
and connection status of the touchpanel:
Unlit during normal operation (the touchpanel is
congured and connected to an IP Link Pro control processor).
Blinks red if the touchpanel has been congured but is
not connected to an IP Link Pro control processor.
Permanently lit if the touchpanel has not been
congured and is not connected to an IP Link Pro control processor.
The indicator can be toggled between enabled and disabled, using the Setup Menu (see page 8).
Light sensor — This sensor monitors ambient light level
D
and adjusts screen brightness, based on the settings congured using the Setup Menu.
100-240V ~ 50-60Hz
2
0.4A MAX
).
2
Figure 9. XTP PI 100 Power Injector
AA
XTP
XTP PWR
PWR
112
B
B C
C D
D B
B
EE
FF
Figure 10. TLP Pro 725C Front Panel and Enclosure Features
Enclosure Features
Activation Switch – the left side of the lid hinge mechanism contains a switch. When the lid is closed, the switch sends the
E
screen into sleep mode. When the lid is opened, the screen display is restored and active.
When the lid is shut, the screen is not activated by motion near the touchpanel.
Speaker — A single speaker, located on the side of the enclosure, provides audible feedback for the user.
F
7
Page 8
TLP Pro 725C Series • Setup Guide (Continued)
e
e
LAN / PoE
275 mA
USB
RESET
MENU
DDEEAABBCC
Base Panel Features
Figure 11. TLP Pro 725C Base Panel
LAN/PoE port — The TLP Pro 725C must be powered through this port (see Step 9 — Connecting the TLP Pro 725C on the
A
previous page for details).
USB port — Compatible with USB 2.0.
B
Reset LED — Provides feedback about the reset status when the user presses the Reset button (see “Reset Modes: a Brief
C
Summary”).
Reset button — Pressing the Reset button allows the unit to be reset in any of three different modes (for an overview, see
D
“Reset Modes: a Brief Summary”).
Menu button — Pressing the Menu button activates the setup menu (see “Setup Menu”).
E
Reset Modes: a Brief Summary
These touchpanels provide the following reset modes (see the TLP Pro 725C Series User Guide for complete information):
Use Factory Firmware — With the unit powered off, press and hold the Reset button (see gure 11,
to the unit. Use this mode with Toolbelt software to replace rmware in the event of conicts arising from uploading a rmware update.
Reset All IP Settings — Press and hold the Reset button for 6 seconds. After the Reset LED (
C
momentarily press the Reset button. Use this mode to reset all network settings without affecting user-loaded les.
Reset to Factory Defaults — Press and hold the Reset button for 9 seconds. After the Reset LED ashes three times, release
and momentarily press the Reset button. Use this mode to return the touchpanel to factory default settings.
Enable or Disable the DHCP Client — This mode toggles between DHCP enabled and DHCP disabled.
) while reapplying power
D
) ashes twice, release and
Setup Menu
Press the Menu button (gure 11, E) to open the setup menu. Figure 12 shows the Status screen. Select any of the ve available screens (Status,
Network, Display, Audio, and Advanced) by
pressing the appropriate button in the navigation bar at the top of the screen (for more information, see the TLP Pro 725C Series User Guide).
For information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics, see the
Extron Safety and Regulatory Compliance Guide on the Extron website.
8
© 2018 Extron Electronics — All rights reserved. www.extron.com
All trademarks mentioned are the property of their respective owners.
Status
Model: TLP Pro 725C
Part Number: 60-1564-02
Firmware Version:
Bootloader Version:1.03.0000
Network
Info
1.02.0001-b001
Display Audio Advanced Exit
Network
IP Address: DHCP: Host Name:
Master Volume: Master Mute: Off
192.168.254.251 Off TLP-AB-CD-EF
Audio
Resolution: GUI Project: Sleep Timer:
99
Controller IP: N/A Project Size: N/A
Display
Advanced
1024x600 N/A 5 Minutes
Figure 12. Setup Menu: Status Screen
68-3319-50 Rev. A
09 18
Loading...