Extron electronics TLP Pro 525M seriesl, TLP Pro 725M series, TLP Pro 1025M Series Setup Manual

TLP Pro 525M, 725M, and 1025M Series • Setup Guide
Overview
The Extron TLP Pro 525M, TLP Pro 725M, and TLP Pro 1025M are three series of wall mounted capacitive touchscreen touchpanels with a TFT active matrix color LCD screens.
The TLP Pro 525M series touchpanels have a 5-inch screen with a 800x480 resolution and 24-bit color depth.
The TLP Pro 725M series touchpanels have a 7-inch screen with a 1024x600 resolution and 24-bit color depth.
The TLP Pro 1025M series touchpanels have a 10.1-inch screen with a 1280x800 resolution and 24-bit color depth.
Setup Checklist
Get Ready
 Download and install the latest version of the following software:
GUI Designer — For designing layouts for Extron TouchLink Global Configurator
and touchpanel.
®
Professional and Global Configurator Plus — For setting up and conguring the control processor
Toolbelt — Provides device discovery, device information, rmware updates, and conguration of network settings, system
utilities, and user management for TouchLink Pro devices.
Global Scripter
NOTE: All four software programs are available from www.extron.com.
®
— Provides an integrated development environment for Extron control systems programming.
 Obtain the following network information from your network administrator:
DHCP status — (on or off). If DHCP is off, you must also obtain:
IP address Subnet mask Gateway
User name — This can be either admin or user. Password — By default, this is extron (for either admin or user).
 Make a note of the touchpanel MAC address.
®
Pro touchpanels and third party touch interfaces.
Mount and Cable All Devices
ATTENTION:
Do not power on the touchpanels or control processors until you have read the Attention in the “Rear Panel Features”
section of the TLP Pro 525, 725, and 1025 Series User Guide or the IPCP Pro User Guide or IPL Pro User Guide.
Ne branchez pas les écrans tactiles ou les contrôleurs avant d’avoir lu la mise en garde dans la section «Rear Panel
Features » du TLP Pro 525, 725, and 1025 Series User Guide ou du IPCP Pro User Guide or IPLProUserGuide.
 Mount the units. There are several mounting options for TouchLink Pro touchpanels (see Mounting on the next page).  Connect the touchpanel to a Power over Ethernet injector (see figure 5 on page 5).  Connect the power injector to the LAN and power it on (see figure 5).
Set up the Touchpanels for Network Communication
 Connect the PC that you are using for setup, the control processor, and the touchpanel to the same Ethernet subnetwork.  Use the Setup Menu (see page 6) or Toolbelt to set the DHCP status and, if necessary, the IP address, subnet mask, gateway,
and related settings for the touchpanel.
Configure the Touchpanels
The GUI Designer Help File, the Global Configurator Help File, and the Toolbelt Help File provide step-by-step instructions and detailed information. The Global Configurator Help File includes an introduction to the software and sections on how to start a project and conguration.
Global Scripter provides an Extron-exclusive Python library (ControlScript®) and Global Scripter modules to get you started.
1
TLP Pro 525M, 725M, and 1025M Series • Setup Guide (Continued)
Mounting
All these touchpanels can be wall-mounted, either using a UL-listed junction box, an external wall box, or directly into drywall or furniture. Suitable mounting accessories can be found at www.extron.com.
ATTENTION:
Do not install touchpanels in a re resistant rated wall or partition assembly.
Ne pas installer les écrans tactiles sur un mur protégé par un dispositif coupe-feu ou dans une cloison.
All structural steps and electrical installation must be performed by qualied personnel in accordance with local and
national building codes and electrical codes.
Toute étape structurelle et installation électrique, doit être effectuée par un personnel qualié, conformément aux
codes du bâtiment, aux codes incendie et sécurité, et aux codes électriques, locaux et nationaux.
Figure 1 shows the TLP Pro 725M. Installation for the TLP Pro 525M or TLP Pro 1025M is very similar.
With a Wall Box or Junction Box
Some local building codes require the touchpanel to be mounted in a junction box. Junction boxes or wall boxes must be purchased separately.
NOTES:
The TLP Pro 525M touchpanels mount to a 1-gang junction box. The TLP Pro 725M and 1025M touchpanels mount to a
2-gang junction box.
Extron provides four 3/4" #6-32 Philips pan head screws for mounting to US junction boxes
Extron provides two 16 mm M 3.5 Philips pan head screws for mounting to MK junction boxes
EU junction boxes are usually provided with their own screws.
With a wall box
1. Install a junction box or wall box (see gure 1,
following the instructions provided by the manufacturer.
2. Fasten the mounting plate to the wallbox (
the provided screws. Use the mounting holes that are appropriate to the junction box you are using (see
figure 2, on the following page).
3. Run and connect cables to the back of the touchpanel
(see Rear Panel Features on the following page).
4. The TLP Pro 525M mounting plate has two hooks
(one in each top corner). The TLP Pro 725 M and TLP Pro 1025M mounting plate has four hooks (3), one in each corner (see figure 2).
Position the touch panel so that the mounting slots (see
figure 4,D) in the rear of the touchpanel align with
these hooks.
5. Move the touchpanel inward and downward so that
touchpanel sits securely on the hooks and the tongue at the bottom of the mounting plate (4) sits in the groove in the bottom of the touchpanel (see inset, gure 1, 5).
6. Fasten the touchpanel to the mounting plate with the
lock screw (6).
2
1
) with
),
3
1
TOP
2
4
4
5
Back View
e
6
2
Figure 1. Mounting the TLP Pro 725M with a Junction Box
Loading...
+ 4 hidden pages