The Extron TLP 710CV 7-inch Cable Cubby® TouchLink™ touchpanel and TLE 710 enclosure provide AV connectivity using
convenient pullout cables. The TLP 710CV also provides simple and versatile conguration and control for a range of IPLink
control systems using a touch screen. The touchpanel communicates through an Ethernet connection to a congurable IP Link
control processor. Video and audio input is provided by a twisted pair cable connected to an MTP transmitter.
NOTE: The network output must connect via a network switch, hub, or router to an Ethernet LAN or the Internet, with
an Extron IP Link controller on the same network. Suggested controllers include IPL T S series (for example, IPL T S4),
IPL250, IPL T CR48, IPLTSFI244, or IPCP series.
The rst four pages of this guide provides basic instructions for experienced installers to mount either the TLP 710CV or the
TLE710. The last four pages show initial conguration for the TLP710CV. For reference material and full instructions about
conguring the touchpanel, see the TLP 710CV User Guide (see www.extron.com).
guide, which is available at
www.extron.com.
®
Tools Required for Installation
Tape Measure
Phillips Screw Driver
Marking Pen
Safety Glasses
Vacuum Cleaner
Square
1/4" Hex Nut Driver
Included Parts
Planning
Before making any cuts, select the best location for the
TLP710CV or TLE 710.
Ensure that the edge that opens on the lid is oriented correctly.
Ensure there is enough space for all the system cables and
components, including cable retractors, if they are to be
installed.
Decide on the method for cutting a hole in the table:
zHand router and template
zCNC wood router
zJigsaw and paper template
Verify that you have the correct template or dimensions.
Check all relevant regulations.
zEnsure the installation complies with local, state, and
national building and electrical codes.
zEnsure the installation complies with the Americans with
Disabilities Act or other accessibility requirements.
Blank AAPs
With Power
Module
Without Power
Module
AC Power Module*10
†
Pass-through AAPs
33
Blank AAPs66
TLP 710CV or TLE 710
AC Power Module*
#4−40 Screws
and Nuts
Pass-thru AAPs
Zip Ties
1-space bracket kit01
2-space bracket kit34
3-space bracket kit11
POWER ON
Power over Ethernet
POWER ACTIVE
LOAD ERROR
AMBER
GREEN
BLINK
LAN-IN
(PoE) Injector
PWR LAN OUT
(TLP 710CV only)
Extron
‡
Table Clamps
Extron
Extron
Removal Tool
(2 brackets/kit)
2 Pos
NOTES:
* Inside the US, the TLP 710CV may be purchased with or without an AC power module. If required, a power module for
the TLE 710 must be purchased separately. Outside the US, see www.extron.com to find an AC power module for
your country.
†
Active or Passive AAPs must be purchased separately (see www.extron.com).
‡
The Power over Ethernet injector is provided only with the TLP 710CV.
3 Pos1 Pos
1
TLP 710CV and TLE 710 • Setup Guide (Continued)
P/N
P/
Mounting the TLP 710CV and TLE 710
Step 1 — Obtain Cut-out Dimensions
ATTENTION:
• The table should be cut only by licensed and bonded craftspeople.
• Make certain the correct cut-out dimensions are being used before proceeding to the next step. Extron is not
responsible for mounting holes that are incorrectly cut.
• The surfaces of the Cable Cubby enclosure have screws and other protruding hardware that could damage ne
furniture. Do not rest the enclosure on unprotected furniture.
• Ensure the table surface is at least 0.375 inches (0.95 cm) thick.
zIf using a hand router, you should purchase the Extron TLP 710CV routing template (part number 70-980-01).
zIf using a CNC wood router, use the exact cut-out dimensions (see below).
zIf using a reciprocating saw or jigsaw use the paper cut-out template (part number 68-2179-01 available under the Downloads
tab on the TLP 710CV page at www.extron.com.).
Step 2 — Cut the Surface
CAUTION: Risk of personal injury: To avoid eye injury, wear safety glasses when operating power equipment.
Be certain the cut is laid out in exactly the desired location and the edge that opens on the lid is correctly oriented. After verifying
and checking dimensions, cut a hole in the surface of the furniture where the enclosure will be installed (see “Preparing the Table”
in the TLP 710CV User Guide). There are three methods for cutting the hole in the table:
Using a hand router
Recommended method — Use the Extron TLP 710CV routing template, part
number 70-980-01. Refer to the Routing Template User Guide, available at
www.extron.com, to prepare the template and use the template to cut the
hole.
NOTE: The metal router guide must be purchased separately. It
is reusable and should not be discarded when the installation is
complete.
CABLE CUBBY 300
HSA 200
USER ACCESS
HSA 200
CABLE CUBBY 300
USER ACCESS
Using a CNC wood cutter
Recommended method — Use the exact cut-out dimensions:
8.90 +0.00/-0.02 inches W x 7.10 +0.00/-0.02 inches D
(22.61 +0.00/-0.05 cm W x 18.03 +0.00/-0.05 cm D)
NOTE: The underlined dimension is the connector or AAP access side
for the unit.
Using a reciprocating saw or jigsaw
Acceptable method — Use the paper cut-out template (part number 68-2179-01
available under the Downloads tab on the TLP 710CV page at www.extron.com.)
P/N 68-2046-01 Rev. B
(Do not cut this line.)
Outer Edge of Trim Ring
4. Cut the opening.
is being installed.
furniture where the TLP 710MV
3. Mark the position on the wall or
(gray) from the template.
2. Remove the surface cut-out area
1. Confirm the product to be installed.
Do not shrink.
Print scale 1:1
Page size: 11" x 17"
TLP 710CV
Cut-Out Template for the Extron
2
2
Step 3 — Run all Cables
of mounting points
Run all cables necessary to support the AC connector, the cables stored in the cubby, and all planned AAP connectors. Run the
cables below the table and through the hole that was cut in Step 2. Leave enough slack in the cables to connect or route them
before the cubby is installed in the table. Leave enough space under the enclosure for the external power supply and connection
of AV cables and the network connection for the TLP710CV.
Step 4 — Install Cable Retractors (Optional)
If required, Extron cable retractors should be installed in the
enclosure at this stage. For complete information about retractors
and how to install them, see the Retractors User Guide, which is
available from the Extron website (www.extron.com).
Step 5 — Install Power Module (Optional)
ATTENTION: For units that are used in North America, only use
AC power modules that are UL Listed Model “Cable Cubby
AC Power Module”.
The unit is not UL Listed if it uses any AC power module other
than Model “Cable Cubby AC Power Module”.
NOTE: For models that do not include a power module, see the
Extron website to select a power module that is suitable for
your location.
The power module takes up two or three AAP spaces, depending on
the model, and may be installed before or after the AAP assembly is
installed. It may be installed with AAPs on either side.
1. Secure the power module into position with #4-40 Phillips
head screws and star washers.
CAUTION:Risk of electric shock: To ensure good
electrical grounding, you must use the star washers with
the screws.
2. Run the cable or conduit to a convenient junction box.
Extron recommends the circuit be attached to a junction
box that is directly wired to the main circuit.
Step 6 — AAP Assembly
Install all desired cables into the cable pass-through AAPs and
install the AAPs into the Cable Cubby.
The simplest way to install the cables and AAPs is to populate
the AAP brackets outside the cubby and then install the
populated AAP shelf assembly into the cubby.
Install cables in the pass-through holes as shown in the gure to the right.
Secure the power module
to the TLP 710CV frame
with #4-40 Phillips head
screws and star washers.
Rear Brackets
TIP: Hand tightening the #4-40 nuts makes it easier to place and
secure the assembly inside the enclosure.
NOTE: An extra column of AAP bracket mounting points is available
for use with TLP Single-space AAP mounting brackets (part
number 70-693-01). Single-space brackets will not fit in any other
location.
The extra column
is for installing
single-space
AAP brackets.