Extron Electronics TLE 350 Setup Guide

TLP 350CV and TLE 350 • Setup Guide
AAP Shelf Bracket Kits
Before connecting the TLP 350CV to a
power source, refer to the TLP 350CV user
guide, which is available at
www.extron.com.

Overview

The Extron TLP 350CV 3.5-inch Cable Cubby® TouchLink™ touchpanel and TLE 350 enclosure provide AV connectivity using convenient pullout cables. The TLP 350CV also provides simple and versatile conguration and control for a range of IPLink control systems via an Ethernet connection, using a required IP Link controller, a touch screen, and 10 customizable buttons. Video and audio input is provided by two BNC connectors.
NOTE: The network output must connect via a network switch, hub, or router to an Ethernet LAN or the Internet, with
an Extron IP Link controller on the same network. Suggested controllers include IPL T S series (for example, IPL T S4), IPL250, IPL T CR48, IPLTSFI244, or IPCP series.
The rst four pages of this guide provides basic instructions for experienced installers to mount either the TLP 350CV or the TLE350. The last four pages show initial conguration for the TLP350CV. For reference material and full instructions about conguring the touchpanel, see the TLP 350CV User Guide, which is available on the Extron website (www.extron.com).

Tools Required for Installation

Tape Measure
Phillips Screw Driver
Marking Pen
Safety Glasses
Vacuum Cleaner
Square
1/4" Hex Nut Driver

Included Parts

Planning

Before making any cuts, select the best location for the
TLP350CV or TLE 350.
Ensure that the edge that opens on the lid is oriented correctly.
Ensure there is enough space for all the system cables and
components, including cable retractors, if they are to be installed.
Decide on the method for cutting a hole in the table:
z Hand router and template
z CNC wood router
z Jigsaw and paper template
Verify that you have the correct template or dimensions.
Check all relevant regulations.
z Ensure the installation complies with local, state, and
national building and electrical codes.
z Ensure the installation complies with the Americans with
Disabilities Act or other accessibility requirements.
Blank AAPs
With Power
Module
Without Power
AC Power Module* 1 0
Pass-through AAPs
4 4
Blank AAPs 3 5
Module
TLP 350CV or TLE 350
AC Power Module*
#4−40 Screws
and Nuts
1-space bracket kit 0 0
2-space bracket kit 2 3
3-space bracket kit 1 1
12 VDC, 1 A
Power Supply
1A MAX
100-240V 50-60Hz
Table Clamps
NOTES:
* Inside the US, the TLP 350CV may be purchased with or without an AC power module. If a power module is
required for the TLE 350, it must be purchased separately. Outside the US, see the Extron website to purchase an AC power module that is suitable for your location.
Active or Passive AAPs must be purchased separately (see the Extron website).
Pass-thru AAPs
Zip Ties
(2 brackets/kit)
2 Pos
3 Pos1 Pos
1
TLP 350CV and TLE 350 • Setup Guide (Continued)
P/N
P/

Mounting the TLP 350CV and TLE 350

Step 1 — Obtain Cut-out Dimensions
ATTENTION:
• The table should be cut only by licensed and bonded craftspeople.
• Make certain the correct cut-out dimensions are being used before proceeding to the next step. Extron is not
responsible for mounting holes that are incorrectly cut.
• The surfaces of the Cable Cubby enclosure have screws and other protruding hardware that could damage ne
furniture. Do not rest the enclosure on unprotected furniture.
• Ensure the table surface is at least 0.375 inches (0.95 cm) thick.
z If using a hand router, you should purchase the Extron TLP 350CV routing template (part number 70-694-01).
z If using a CNC wood router, use the exact cut-out dimensions (see below).
z If using a reciprocating saw or jigsaw use the paper cut-out template (part number 68-2148-01, available under the
Downloads tab on the TLP 350CV page at www.extron.com.)
Step 2 — Cut the Surface
CAUTION: Risk of personal injury: To avoid eye injury, wear safety glasses when operating power equipment.
Be certain the cut is laid out in exactly the desired location and the edge that opens on the lid is correctly oriented. After verifying and checking dimensions, cut a hole in the surface of the furniture where the enclosure will be installed (see “Preparing the Table” in the TLP 350CV User Guide). There are three methods for cutting the hole in the table:
Using a hand router
Recommendedmethod — Use the Extron TLP 350CV routing template, part number 70-694-01. Refer to the Routing Template User Guide, available at
www.extron.com, to prepare the template and use the template to cut the
hole.
CABLE CUBBY 300
NOTE: The metal router guide must be purchased separately. It
HSA 200
is reusable and should not be discarded when the installation is complete.
USER ACCESS
HSA 200
Using a CNC wood cutter
Recommendedmethod — Use the exact cut-out dimensions:
7.50 +0.00/-0.02 inches W x 6.00 +0.00/-0.02 inches D
(19.05 +0.00/-0.05 cm W x 15.24 +0.00/-0.05 cm D)
NOTE: The underlined dimension is the connector or AAP access side
for the unit.
Using a reciprocating saw or jigsaw
Acceptablemethod — Use the paper cut-out template (part number 68-2148-01, available under the
Downloads tab on the TLP 350CV page at www.extron.com.)
2. Remove the surface cut-out area
1. Confirm the product to be installed.
Do not shrink.
Print scale 1:1 Page size: 11" x 17"
P/N 68-2046-01 Rev. B
(Do not cut this line.)
Outer Edge of Trim Ring
4. Cut the opening.
is being installed.
furniture where the TLP 710MV
3. Mark the position on the wall or
(gray) from the template.
CABLE CUBBY 300
USER ACCESS
TLP 710CV
Cut-Out Template for the Extron
2
2
Step 3 — Run all Cables
star washers.
installing single-space
Run all cables necessary to support the AC connector, the cables stored in the cubby, and all planned AAP connectors. Run the cables below the table and through the hole that was cut in Step 2. Leave enough slack in the cables to connect or route them before the cubby is installed in the table. Leave enough space under the enclosure for the external power supply and connection of AV cables and the network connection for the TLP350CV.
Step 4 — Install Cable Retractors (Optional)
If required, Extron cable retractors should be installed in the enclosure at this stage. For complete information about retractors and how to install them, see the Retractors User Guide, which is available from the Extron website (www.extron.com).
Step 5 — Install Power Module (Optional)
ATTENTION: For units that are used in North America, only use
AC power modules that are UL Listed Model “Cable Cubby AC Power Module”.
The unit is not UL Listed if it uses any AC power module other than Model “Cable Cubby AC Power Module”.
NOTE: For models that do not include a power module, see the
Extron website to select a power module that is suitable for your location.
The power module takes up two or three AAP spaces, depending on the model, and may be installed before or after the AAP assembly is installed. It may be installed with AAPs on either side.
Install the power module on the left side.
Push the module through the bottom of the enclosure. Secure the module in place with #4-40 Phillips head screws and
1. Secure the power module into position with #4-40 Phillips
head screws and star washers.
CAUTION: Risk of electric shock: To ensure
good electrical grounding, you must use the star washers with the screws.
2. Run the cable or conduit to a convenient junction box.
Extron recommends the circuit be attached to a junction box that is directly wired to the main circuit.
Step 6 — AAP Assembly
Install all desired cables into the cable pass-through AAPs and install the AAPs into the Cable Cubby.
The simplest way to install the cables and AAPs is to populate the AAP brackets outside the cubby and then install the populated AAP shelf assembly into the cubby.
Install cables in the pass-through holes as shown in the gure to the right.
TIP: Hand tightening the #4-40 nuts makes it easier to place
and secure the assembly inside the enclosure.
NOTE: An extra column of AAP bracket mounting points is available for use with TLP
single-space AAP mounting brackets (part number 70-693-01). Single-space brackets do not fit in any other location.
Rear Brackets
The extra column of mounting points is for
AAP brackets.
3