The SW VGAxi / MACxi are 350 MHz bandwidth switchers are housed in rack mountable, 1U high, half width metal enclosures with internal, universal 100 - 240 VAC 50/60 Hz power supplies. They have built-in standard contact closure remote control capability with Tally through the 25 pin Contact Remote connector (see Contact Remote pin assignments - Figure 4-A). Optional remote controls available for both switcher types are the KP-10 wired remote with 25 foot cable, the IR-10 Infrared remote control with an operating range of approximately 30 feet and the RS-232 2,4,6,8 Controller. VGAxi switchers are available with 2, 4 or 6 inputs while the SW MACxi is only available with 2 inputs. If more than 2 MAC inputs are required, the SW4 VGAxi or SW6 VGAxi may be used with VGA/MAC adapters (see connection diagram in Figure 3-A and Part Numbers on Page 5).
Auto-switching
Auto-switching is a feature of the SW VGAxi and SW MACxi switchers that can be enabled/disabled using a switch on the rear panel (see item E in Figure 2-A). With the AUTO/MANUAL switch in the AUTO position, the front panel AUTO SWITCH ACTIVE LED is ON, the input selection buttons are disabled, and the switcher automatically selects the highest number input that has sync pulses available.
Figure 1-A
Front Panel Component Descriptions
The letters next to the following descriptions match the circled letters in Figure 1-A above. A Auto Switch Active LED - ON = Auto switch mode active (Rear panel Auto/Manual switch UP)
B Input selection switches and LEDs - LED for selected input will be ON.
Installation and Operation
Extron • SW Switchers VGAxi / MACxi • User’s Guide
Page 2
Figure 2-A
Rear Panel Component Descriptions
The letters next to the following descriptions match the circled letters in Figure 2-A above. C AC power connector - Standard IEC power connector (100 - 240 VAC 50/60 HZ)
D Power LED - ON if AC power is present E AUTO/MANUAL switch - Down = normal mode, UP = Auto switch mode F VGA Input connectors G VGA Output connector H Contact Remote connector - 25-pin contact closure connector - see Page 4 for details.
Features
• Two, four or six inputs available, depending on the model
• 350 MHz bandwidth (-3 dB)
• Auto-switchable (switch selectable)
• 25 pin contact closure remote control connector
• Unselected inputs are 75 ohm terminated
• Tactile switch buttons with LEDs
• 1U, 1/2 rack width enclosure
• Internal universal power supply
• Input/Output connectors - VGAxi = Female 15 pin HD, MACxi = Female 15 pin D
• VGAxi is compatible with IBM PS/2, VGA, SuperVGA, XGA, VESA and XGA-2 computers. MAC and Quadra may be used with SW 2 MACxi, or, if more than two inputs are required, SW 4/6 VGAxi switchers may be used with optional MAC/VGA adapter (26-340-01 or 26-340-02).
Connection Diagrams
Extron • SW Switchers VGAxi / MACxi • User’s Guide
Page 3
LCD Projector
MAC Computer
Extron Interface
Extron Interface
MAC Computer
PC Monitor
PC Computer
PC Computer
PC Computer
MAC Computer
MAC Computer
PC Computer
VGA/MAC Adapters
Figure 3-A
SW 6 VGAxi switcher diagram
Figure 3-B
SW 2 MACxi switcher diagram
Remote Connector
Extron • SW Switchers VGAxi / MACxi • User’s Guide
Page 4
REMOTE Connector - The Remote connector provides a way to control the VGAxi / MACxi switchers
using contact closure devices such as the following:
• Extron KP-10 (wired remote keypad, IR-10 (infrared remote), RS-232 2-4-6-8 (Host computer)
• Third Party Remote Control - Information below may be used to design a third party remote control. Remote connector pin assignments are shown in the table below (Figure 4-A). To select a different
switcher input number through the remote connector, momentarily connect the pin for the desired input number (#) to logic ground (pin 25).
NOTE __ The duration of a momentary connection is defined as 250 — 500 milli-seconds.
The Tally pins can be used for remote indication of the switcher's selected input. Tally #1 - #6 (pins 14 -19) will indicate the switcher's selected input # with a logic low (0 volts), the Tally pins are normally at logic high (5 volts). For example, with switcher input #2 selected, the front panel LED for that input would be ON and Tally #2 (pin 15) would be 0 volts while the remaining Tally pins would be 5 volts. The schematics shown below (Figure 4-B) may be used as a guide to design and build indicator circuits for the Tally pins. An example of an LED circuit is shown at the top, two versions of incandescent lamp driver circuits are shown below the LED circuit. The +5 volt source on remote connector pin 13 is limited to 100mA, if a different voltage or a higher current is required, an external voltage source will be necessary. Looping is a configuration technique (see Figure 4-C) that enables the total number of inputs to a switcher (A) to be increased by connecting its highest input to the output of another switcher (B). A Loop control signal from switcher B (Loop Out - Remote connector pin 24) to switcher A (Loop In ­Remote connector pin 12) will cause switcher A to select its highest input when an input selection is made on switcher B. If a third switcher (C) is added, its output would connect to the highest input on switcher B and its Loop Out signal would connect to switcher B's Loop In. An input selection on Switcher C would cause switcher B to select its highest input and signal switcher A to select its highest input. The selected input on switcher C would be available at Switcher A's output. An input selection on Switcher A would drop Switchers B and C out of the loop until a selection is made on either B or C.
Output
C
B
A
FIGURE 4-A
N/C
1N916
TALLY PIN
EXTERNAL POWER
+5V (PIN 13)
Using a Relay & External Power
+5V (PIN 13)
TALLY PIN
LED
330 Ohm
LED INDICATOR CIRCUIT
FIGURE 4-B
+5V (PIN 13)
EXTERNAL POWER
TALLY PIN
RESISTOR VALUE DEPENDS ON CURRENT REQUIREMENT OF LAM
P
330 Ohm
Using an Opto-isolator & External Power
INCANDESCENT LAMP CIRCUITS
RECOMMENDED RELAYS MANUFACTURER GENERAL LOW C URRENT AROMAT DS2 TQ ITT/PANASONIC R-Z-5C A5W OMRON G5Y G6H
FIGURE 4-C
Extron Electronics, Asia
41B Kreta Ayer Road Singapore 089003 +65.226.0015 FAX +65.226.0019
Singapore
Extron Electronics, Europe
Beeldschermweg 6C 3821 AH Amersfoort +31.33.453.4040 FAX +31.33.453.4050
The Netherlands
Extron Electronics
1230 South Lewis Street Anaheim, CA 92805
714.491.1500 FAX 714.491.1517
USA
SM
Specifications
Refer to the safety instructions in the literature that came with
this equipment.
Specifications
Video Input Video Signal Level _ 0 to 2 volts p-p
Video Gain _ Unity Frequency Range (H. Sync) _ 15-145 kHz Frequency Range (V. Sync) _ 30-170 Hz
RGB Video Bandwidth _ 350 MHz (-3 dB) (VGAxi and M
AC
xi
)
Input Impedance _ 75 Ohms
Output Impedance _ 75 Ohms
Termination Impedance _ 75 Ohms
Sync Input Impedance _ 510 Ohms
Connectors Input and Output VGA
xi __
15 pin HD D-Sub (Female)
Input and Output M
AC
xi __
15 pin D-Sub (Female)
Contact Remote _ 25 pin D-Sub
Control System Contact Closure _ Momentary (100 ms min.),
_ w/Tally feedback
Loop Signal _ Momentary low, 1 ms min, 5 ms max
General Operation Temperature _ 0°-50° C
Storage Temperature _ -40° to +70° C
Humidity _ 10% to 90% non condensing
MTBF Demonstrated _ 30,000 Hours
Vibration _ NSTA 1A in carton
Approvals _ CE, UL Listed, FCC Class A
Power Supply Internal _ 100-240 VAC 50/60 Hz, 0.2A max.
Dimensions _ 8.75" W x 9.5" D x 1.75" H
_ 22.2 cm W x 24 cm D x 4.4 cm H
Shipping Weight _ 3 lbs (1.4 kgs) - VGA
xi
and M
AC
xi
Warranty _ 2 years parts and labor
Part Numbers SW2 VGA
xi __
60-257-01
SW4 VGA
xi __
60-258-01
SW6 VGA
xi __
60-259-01
SW2 MAC
xi __
60-261-01
VGA/MAC Adapter (Composite Video) _ 26-340-01
VGA/MAC HV Adapter (MAC H/V sync) _ 26-340-02
KP-10 wired keypad remote control _ 60-111-01
IR-10 Infrared remote control _ 70-036-01
RS-232 2-4-6-8 Controller _ 60-112-01
VGA connector pin-9 is normally not used and does not exist in most cases, however, some equipment/applications may require the signal on input connector pin-9 to be passed to output connector pin-9. If this is a requirement, it will be necessary to solder one or more jumpers onto the inside of the rear panel. The jumpers (JMP1 - JMP6) are shown on the Printed Circuit Board layout below. The switcher model determines which jumper applies to which input as follows:
I
NPUT 1INPUT 2INPUT 3INPUT 4INPUT 5INPUT 6
SW6 VGA
xixi
xixi
xi JMP1 JMP2 JMP3 JMP4 JMP5 JMP6
SW4 VGA
xixi
xixi
xi JMP3 JMP4 JMP5 JMP6
SW2 VGA
xixi
xixi
xi JMP5 JMP6
To access the inside of the rear panel, DISCONNECT POWER and remove four screws from the top of the switcher. The bottom panel can then be removed. Unplug the two cables connected to the circuit board enabling it to be removed.
JMP5
JMP3
JMP1
JMP2JMP4
JMP6
Figure 5-A
SW SWITCHERS – VGAxi
/ MACxi
SW2 VGA
xixi
xixi
xi
SW4 VGA
xixi
xixi
xi
SW6 VGA
xixi
xixi
xi
SW2 MAC
xx
xx
ii
ii
i
USERS GUIDE
Written & Printed in the USA
89-05
68-375-01
Rev. A
Loading...