Extron Electronics SMB 100 User Manual

IMPORTANT:
Refer to www.extron.com for the
complete user guide, installation
SMB 100 Series • Installation Guide
instructions, and specifications.
The Extron SMB Series Surface Mount Boxes are designed for mounting various Extron architectural products, including wall plates, Architectural Adapter Plates (AAP), AAP Mounting Frames, and MediaLink® Controllers. Each box can be surface mounted on a tabletop or wall for convenient access to connectors and controls.
The back and bottom of the boxes feature AAP openings. Blank AAP panels are included to ll unused openings.
This guide provides information for a qualied, experienced installer to install an SMB surface mount box.
SMB 101
Single-gang Surface Mount Box
SMB 104
Four-gang Surface Mount Box
SMB 102
Two-gang Surface Mount Box
SMB 105
Five-gang Surface Mount Box
SMB 103
Three-gang Surface Mount Box
SMB 107
Seven-gang Surface Mount Box
Recommended Fasteners
Choose the appropriate type of screw or bolt for the mounting surface (see the table below). The mounting holes in the bottom panel of the SMB accommodate #6 or 1/4 inch screws.
Wall Type Fasteners Min. Size Fastener
Drywall Toggle bolts 3/16 inch At least 3 1/2 inch Min. 3/8 inch wall thickness
Solid wood Wood screws #6 with a washer At least 3 3/32 inch Min. 3/8 inch wall thickness
Masonry Masonry screws 1/4 inch At least 3 3/16 inch masonry bit Do not mount to masonry joints.
Quantity
Drill Bit Size Notes
Grounding
The bottom plate includes a #6‑32 stud insert for grounding; a grounding nut is included with each SMB.
Mounting the SMB
NOTES:
• This unit must be installed in accordance with the National Electrical Code and with all local codes.
• Ensure that the installation meets the local and state regulatory requirements, including building, electrical,
and safety codes, and ADA accessibility requirements.
• Ensure that there are no utility cables or pipes at the intended location that might be damaged or cause injury
when installing the box.
The SMB can be mounted on any interior wall type or on a tabletop. Knockouts allow for raceways to be run from the top or rear of the box. Install the cables into the wall or raceway before mounting the box or installing any devices in the SMB. The installation instructions apply to all models.
1
SMB Series Surface Mount Boxes • Installation Guide (Continued)
Mounting the SMB to a Surface
1. Find a suitable location and use a non‑permanent marker or tape to outline
at least one corner of the SMB perimeter on the surface.
To access the rear keyhole slots or other mounting holes, it may be necessary to remove the enclosure cover. To remove the cover, rst remove three screws on each side (six total), then lift the cover off.
2. Using the bottom plate, mark the pilot hole
locations for the:
a. three keyhole slots, or
b. two mounting holes.
NOTE: Alternately, 1/4 inch bolts can be
used in the larger portion of the keyhole slot. Mark the pilot holes accordingly.
3. If required, mark the location for the cable
2a
Keyhole Slots (3)
access hole.
4. Drill 3/32 inch pilot holes for the keyhole slots
marked in step 2aor the mounting holes marked in step 2b.
z Cut cable access hole marked in step 3.
z If using the smaller portion of the keyhole
Grounding Stud
slots, insert screws into the pilot holes, but
5. Mount the SMB bottom plate with the fasteners.
6. If the cover was removed, replace it.
do not tighten until the bottom plate is slid into position.
Bottom Plate
1
Mark location of bottom plate.
SMB 103
Three-gang SMB (shown)
(Optional)
3
Mark Cable Access Location
2b
Mounting Holes (2)
Cable Routing
Cables may access the SMB through the AAP openings and through raceway knockouts.
1. If cables enter the SMB through the rear panel, use the rear panel AAP openings. AAP modules are sold separately.
2. With the SMB fastened to the mounting surface, run all necessary cables through the pass‑through opening before installing
any device(s) into the SMB.
NOTE: A nut is provided for grounding installed devices.
3. Once the SMB is secured, cable the connections, then install the AAPs or other devices.
ExtronHeadquarters
+800.633.9876 Inside USA/Canada Only
 ExtronUSA-West ExtronUSA-East
+1.714.491.1500 +1.919.850.1000
+1.714.491.1517 FAX +1.919.850.1001 FAX
© 2012 Extron Electronics All rights reserved. All trademarks mentioned are the property of their respective owners. www.extron.com
ExtronEurope
+800.3987.6673
Inside Europe Only
+31.33.453.4040
+31.33.453.4050 FAX
ExtronAsia
+800.7339.8766
Inside Asia Only
+65.6383.4400
+65.6383.4664 FAX
ExtronJapan
+81.3.3511.7655
+81.3.3511.7656 FAX
ExtronChina
+4000.EXTRON +4000.398766
Inside China Only
+86.21.3760.1568
+86.21.3760.1566 FAX
ExtronMiddleEast
+971.4.2991800
+971.4.2991880 FAX
ExtronKorea
+82.2.3444.1571
+82.2.3444.1575 FAX
ExtronIndia
1800.3070.3777
Inside India Only
+91.80.3055.3777
+91.80.3055.3737 FAX
68-2302-01 Rev.A 08 12