Extron Electronics SMB 1 User Manual

SMB 1 • Installation Guide
Strain Relief Clamp
ews
Mounting Holes (4)
The Extron SMB 1 surface mount box ships with the included parts shown in the gure to the right. It offers a variety of mounting options for the TLPPRO320M and TLPPRO520M:
z Stand the box on a suitable surface — The SMB 1 has
two anti-skid pads attached to the bottom that allow it to stand on a suitable surface without attaching it to the surface.
swivel mount adapter kit (not provided) allows the SMB1 to be permanently mounted for security, but rotated to provide access to the touchpanel from around the table. See the SMA-1 Installation Guide, at www.extron.com before installing the SMB 1.
z Permanently attach the box to a glass surface — Use
the optional GMK 1 kit (not provided). See the GMK 1 Installation Guide, at www.extron.com.
z Secure the box to a suitable surface — This allows the
SMB 1 to be permanently secured to a table-top or wall (see “Mount the SMB 1 Directly to Furniture or a Wall,” below).
Rear Cable
Access Cover
#4 Sheet Metal
Screws
(2 each)
Strain Relief Boot
SMB 1
Zip Ties (2 each)
Cable Wrap
Bottom Cable
Access Plug
#8 Wood Scr
and washers
(4 each)
#6 Sheet Metal
(4 each)
Screw Size and Type (Number) and Function
#4-20 x 5/16" Sheet Metal
#8-15 x ¾" Wood
#6-19 x 3/8" Sheet Metal
(2) Secure rear cable access cover
(4) Secure SMB 1 to furniture
(4) Secure wall plate adapter to SMB 1
Screws
Mount the SMB 1 Directly to Furniture or a Wall
The illustrations in this section of the guide show the SMB 1 mounted to a table-top or lectern. Wall mounting is identical except that the base of the SMB 1 is vertical, against the surface of the wall.
ATTENTION:
1. Determine where the SMB 1 is to be mounted.
2. Mark the position of the four mounting holes and drill four pilot
3. If cable access is required through the base of the SMB 1,
4. Secure the SMB 1 to a table-top using the four provided
Four wood screws are provided to mount the SMB 1 to a table top. To mount the SMB 1 to a wall, use screws and
xtures that are appropriate for the wall material. These are not provided.
All structural steps and electrical installation must be performed by qualied personnel in accordance with local and
national building codes and local and national electrical codes.
holes 3/32inch (2.4 mm) in diameter into the tabletop or wall.
remove the hole plug from the bottom cable access hole. Mark
#8 Wood Screws with Washers (4)
the position of the hole and drill a hole through the table that is large enough to carry the cables.
#8wood screws with washers.
Bottom Cable Access Hole
SMB 1 • Installation Guide (Continued)
Rear Cable
Strain Relief Clamp
ws (2)
all Plate Adapter
Cabling
Run cable to the SMB 1 before installing the touchpanels. Leave some slack in the wiring during installation.
From Underneath
1. Bundle the wiring using the provided cable wrap.
2. Feed it from under the furniture through the hole drilled in the table in step 3 of the
previous section.
3. Secure the cable with one or more zip ties as shown in the inset of the gure to the
right.
From the Rear
1
Access Opening
Cover cables with Cable Wrap
2
3
4
Strain Relief Boot
1. Remove the rear cable access pop-out (
in gure above).
a
5
#4 scre
2. Bundle the wiring using the provided cable wrap and feed it through the rear cable
access opening (b).
3. Trim the strain relief boot to t the wiring and cable wrap (
4. Slide the boot over the wiring and cable wrap and into the rear cable access opening (
5. Place the strain relief clamp into the boot and fasten it with the provided
c
).
#4sheetmetalscrews (e).
6. Secure the wires and cable wrap with a zip tie (
in the gure to the right).
f
Install the TouchPanel
1. Secure the wall plate adapter to the SMB 1, using the four provided
#6 sheet metal screws.
2. Run cables through the rear cable pop-out or the hole in the base
and connect them to the back panel of the touchpanel (see the TLPPRO320M User Guide or the TLP PRO 520M User Guide at
www.extron.com).
3. Press the touchpanel onto the wall plate adapter. Four catches hold
the touchpanel in place.
4. Remove the bezel and attach the touchpanel to the wall plate
adapter with the two Phillips head screws (#4-40 x ¼") that are provided with the touchpanel. For extra security, these screws can be replaced with two security screws of the same size (not provided).
5. Replace the bezel.
Extron Headquarters
+1.800.633.9876 (Inside USA/Canada Only)
Extron USA - West Extron USA - East
+1.714.491.1500 +1.919.850.1000 +1.714.491.1517 FAX +1.919.850.1001 FAX
Extron Europe
+800.3987.6673 (Inside Europe Only)
+31.33.453.4040 +31.33.453.4050 FAX
Extron Asia
+65.6383.4400 +65.6383.4664 FAX
© 2014 Extron Electronics All rights reserved. www.extron.com
Extron Japan
+81.3.3511.7655 +81.3.3511.7656 FAX
Extron China
+86.21.3760.1568 +86.21.3760.1566 FAX
#4-40 x ¼" Screws (2)
).
d
Extron Middle East
+971.4.299.1800 +971.4.299.1880 FAX
Bezel snaps to unit (2 places on top and 2 places on the bottom)
TLP Pro
#6 Sheet Metal Screws (4)
W
Extron Korea
+82.2.3444.1571 +82.2.3444.1575 FAX
6
SMB 1
Extron India
1800.3070.3777 Inside India Only
+91.80.3055.3777 +91.80.3055.3737 FAX
68-2298-01 Rev. A
02 14
Loading...