The Extron® PVS 405D is a ve input, one HDMI output switcher with a built-in audio amplier and a 3-port Ethernet switch. It is part of the PoleVault®,
SELECT
R
CONFIG
AUDIO
1
345
2
AUX
INPUT
PlenumVault®, and WallVault® Digital Systems, and is used in conjunction with the Extron PVT digital series of transmitters and Extron speakers. The PVS 405D accepts HDMI and high resolution (RGB) video and audio signals. The RGB input is digitized at the PVT input wallplate. In addition, it has dedicated ports for connecting the optional VoiceLift and a Page Sensor unit for facility communications.
NOTE: For full installation, configuration, connector wiring, and operation details, see the PVS 405D User Guide, available at
www.extron.com.
Installing and Cabling the PVS 405D Switcher
The PVS 405D may come already pre-mounted in the Extron PMK 560 (Projector Mount Kit) and the PVM 220 (PlenumVault Mount Kit).
However, if it is not pre-mounted, to mount the PVS 405D, follow the steps in the system installation guide, supplied with the complete PoleVault, PlenumVault, or WallVault System. Alternatively follow the steps in the relevant Setup Guide for the mounting kit (PMK 560, PVM 220, WMK 160, or USFM 100). Connect the cables to the switcher as shown below.
PEAK
NORMAL
SIGNAL
AUDIO LEVEL ADJUSTINPUTS
VOICELIFT
PEAK
NORMAL
SIGNAL
PAGING SENSOR
SENSITIVITY
POLEVAULT SWITCHER
system
PVS 405D
ATTENTION: The PoleVault signal transmission method is specic for PVS 405D switchers working with PVT digital wallplates.
DO NOT connect the input ports to an MTP system or to an Ethernet/LAN or data transmission system.
NOTES:
The PVS 405D is capable of receiving signals from PVT wallplates located up to 150 feet (45 m) away.
RJ-45 termination must comply with the TIA/EIA T 568A or 568B wiring standards for all connectors. The same standard
MUST be used at both ends of all cables. Refer to the PoleVault System Installation Manual for details. The cables supplied with the PoleVault system are terminated to the TIA 568A standard.
The use of shielded cable, such as Extron STP201 or Extron XTP DTP 24 cable, is strongly recommended.
POWER 12V 3A MAX
12
Power Connector
nal Power Supply
Line Out Output (Audio)
INPUTS OUTPUT AUDIO OUT
1/2
3/4
AUDIO
IN OUT
VGA IN
HDMI Output
LOCAL OUT
to Display Device
HDMI
6 2 3
HDMI Connector
SIG LINKSIG LINK
PVT IN PVT IN
1
HDMI/RGB
AUDIO IN
HDMI IN
IR OUT
S G
PVT SW HDMI RGB D HDMI or RGB video/audio, Inputs1/2 and 3/4 1 STP cable with RJ-45 connectors
7
L
R
INPUT 5
L
R
Aux Audio Input 5
Sensor Input
PAGING
SENSOR
AUX OVER PVT REMOTE
Aux Input
Figure 1. PVS 405D Switcher Connections
5
+V
+V
PVS 405D
VOICELIFT
4
VoiceLift Receiver
Audio Output to Speakers
PVS terminal
Speaker
(left and right)
wire color
Red Positive (+) Black Negative (-)
AMPLIFIED AUDIO OUT
DO NOT
GROUND
OR SHORT
SPEAKER OUTPUTS
CLASS 2 WIRING
RS-232
IR
Tx Rx
SG G
10
SG
IR control
8
LR
4/8
Ω
MLC 104 IP Plus
9
RS-232 input
NOTE: You must
connect a ground wire between the MLC and PVS.
Ground (Gnd)
Receive (Rx)
B A
NOTE: If you use cable that
has a drain wire, tie the drain wire to ground at both ends.
Transmit (Tx)
Transmit (Tx)
Receive (Rx)
3-port 10/100 Ethernet Switch
Connect to ports as follows:
1. TCP/IP network
2. MLC controller
3. Optional network device
11
LAN 1 LAN 2 LAN 3
MLC wire color
White Tx on RS-232 port Violet Rx on RS-232 port Drain wire Ground (G) Black PVS Power Supply (–) Red PVS Power Supply (+)
B A
Rx
AB
MLS PWR
RS-232 12V
To PVS terminal
Ground
B
+12 VDC input
Tx
MLC 104 IP Plus right side
+12V IN
GROUND
GROUND
panel MLS and Power ports
To Supplied PVS Switcher Power Supply
1
PVS 405D • Setup Guide (Continued)
Step 1 — Connect A/V inputs
a HDMI and RGB video and audio inputs — Using recommended TP cables (see the Notes re cables on page 1), connect
up to four HDMI or RGB input sources via the PVT SW HDMI RGB D or PVT SW HDMI D input wallplates to these two RJ-45 female connectors. These inputs can be four HDMI with embedded audio, or two HDMI and two high resolution computer video and audio sources, or a combination. The front panel input selection button toggles the inputs 1 through 4 as required.
NOTE: Each PVT input wallplate supports two input sources. A maximum of two PVT input wallplates can be connected
to the PVS 405D.
Audio input — Input 5 is a dedicated-audio only input for an auxiliary, stereo, line-level analog audio signal from an
b
output source such as an iPod device or an MP3 player. Connect the cable from the source to this 5-pole captive screw connector. The connector can be wired as balanced or unbalanced (see the PVS 405D User Guide for method).
NOTE: Input 5 is audio only. No video signals are supported on this input.
Aux input — Connect an auxiliary audio device to this 3-pole captive screw connector. It can be wired for balanced or
c
unbalanced mono audio. Aux audio can be congured to duck program audio or to be mixed with program audio (inputs 1-5).
VoiceLift receiver connection — Connect an optional Extron VoiceLift receiver to this RJ-45 connector for the
d
integration of a VoiceLift Microphone system.
NOTE: The Extron VoiceLift Microphone Kit is an optional accessory and must be purchased separately.
Paging sensor input — Connect the optional Extron Priority Page Sensor Kit to this port, to enable program audio
e
interruptions during paging system broadcasts.
NOTE: Priority Page Sensor Kits (part numbers 70-1064-01 or 70-619-01) are optional accessories, purchased separately.
Step 2 — Connect A/V Outputs
HDMI output — Connect an HDMI capable display or the projector to this female HDMI connector.
f
Audio Out (line level) — This port is used for connecting an external Extron audio amplier, a recording podcasting
g
device, or an assistive listening system. It can be congured via RS-232 or USB for xed or variable audio output (default is variable). It can be wired for balanced or unbalanced signals (see the PVS 405D User Guide for method)..
Amplified Audio Out — Connect speakers to each channel marked “L” and “R” (left and right) using the supplied black
h
4-pin, 5 mm connector. Wire red to positive, black to negative. Each channel is rated for 25 W at 4 or 8 ohm loads. If using more than one speaker per channel, connect them in parallel.
ATTENTION: DO NOT tie L and R outputs to each other and/or to ground as it will short the outputs and damage the amplifier.
Step 3 — Connect Remote Control, IR, and LAN Connectors
Remote (RS-232/MLC) control port — The PVS switcher can be controlled via an RS -232 connection directly from a
i
host computer, a control system, or a MediaLink® Controller (MLC). The MLC provides remote control of input switching and volume. Connect a cable between this port and the MLC MediaLink Controller (see gure 2). The RS-232 protocol is 9600 baud, 8-bit, 1-stop bit, no parity, and no ow control. See the MLC 104 IP Plus User Manual for full details.
NOTE: To power the MLC 104 IP Plus wire it directly into the same power supply the switcher uses (see gures 2 and 3).
INPUTS OUTPUT AUDIO OUT
1/2
3/4
SIG LINK SIG LINK
POWER 12V 3A MAX
PVT IN PVT IN
Projector
DISPLAY
ON
VCR
OFF
1
DVD
VOLUME
2
PC
3
CONFIG
4
MLC 104 IP PLUS
Tx
DISPLAY RS-232/IR
2
L
HDMI
INPUT 5
L
RS-232
Ground
Rx
Tx
RS-232/IR
PRESS TAB WITH
TWEEKER TO REMOVE
LAN
2
3
1
GROUND
COMM LINK
Rx
CM
SCP
IR IN
A B
GROUND
MLS PWR
DIGITAL
RS-232 12V
I/O
Rx
IR OUT
GROUND
+V OUT
A B C D E
Figure 2. MLC 104 IP Plus to PVS 405D Connection
PVS 405D
PAGING
SENSOR
R
VOICELIFT
+V
AUX OVER PVT REMOTE
R
IR control
S
IR Out
Ground
G
RS-232
Tx
DISPLAY
Tx
Receive (Rx)
Rx
IR OUT
GROUND
+12V IN
GROUND
GROUND
A
Transmit (Tx)
B
Tx
Rx
AB
MLC 104 IP Plus right side panel
+12V IN
GROUND
GROUND
MLS and Power ports
MLS PWR
Ground (Gnd)
G
Ground +12 VDC input
Transmit (Tx) Receive (Rx)
AMPLIFIED AUDIO OUT
DO NOT
GROUND
OR SHORT
SPEAKER
OUTPUTS
CLASS 2 WIRING
RS-232
IR
Tx Rx
SG G
Tx Rx
LR
4/8
Ω
NOTES:
• You must connect a ground wire between the MLC and PVS.
• If you use cable that has a drain wire, tie the drain wire to ground at both ends.
LAN 1 LAN 2 LAN 3
To Supplied PVS Switcher Power Supply
(12 VDC, 4 A max.)
IR control port — Connect the wiring from the IR Out port on rear of the MLC to this connector. IR signals on this
HDMI
1/
S
LINK
S
LINK
3/
S
OUTPUTAUDIO OUT
5D
G
SENSO
AUX
VOIC
INPUT 5
R
RS-232 12V
O
T
IR
S
G
LAN 1
LAN 2
LAN 3
L
R
4/
Ω
DO NOT
GROUND
OR SHO
S
R
O
S
T
CLASS
G
j
connector are passed to the connected PVT wallplate for control of devices, such as BluRay or DVD players.
Ethernet connectors — Connect LAN cables to these three ports for 10/100 Ethernet connectivity as follows:
k
1.
TCP/IP network (owner furnished), 2. MLC MediaLink controller, 3. Optional network device
Step 4 — Connect power
DC power connector — When all other cables have been connected, plug the cable with the orange captive screw
l
connector (supplied with the power supply) from the 12 VDC power source into this receptacle and apply power. The front panel power LED and an input LED illuminates when the switcher is receiving power.
NOTE: Use only the supplied 12 V, 4 A power supply for this switcher. The PVS 405D power supply can support a typical
system: for example, a PVS 405D, 2 PVT Wallplates, 2 or 4 speakers, an MLC 104 IP Plus with an IRCM DV+, and a VoiceLift Microphone system. If an additional SCP 104 is used, the MLC 104 IP Plus MUST have its own power supply.
PVS 405D
POWER 12V 3A MAX
INPUTS OUTPUT AUDIO OUT
INPUT
1/2
3/4
2
4
SIG LINKSIG LINK
IG
PVT IN PVT IN
HDMI
IG
PVS 40
PAGING
PAGIN
R
SENSOR
L
R
VOICELIFT
ELIFT
+V
+V
AUX OVER PVT REMOTE
INPUT 5
L
R
AMPLIFIED AUDIO OUT
AMPLIFIED AUDIO OU
DO NOT
GROUND
RT
OR SHORT
PEAKE
SPEAKER
UTPUT
OUTPUTS
CLASS 2 WIRING
2 WIRIN
VER PV
IR
Tx Rx
SG G
RS-232
4/8
8
Ω
LR
LAN 1 LAN 2 LAN 3
Front Panel Overview
1
a Power indicator LED — This LED lights green when power is supplied, and amber when in power save mode. b Device Reset button — Pressing this inset button resets the switcher to default settings. See the PVS 405D User Guide
for reset mode details.
c Front panel mini USB configuration port — Connect a computer to this mini USB port (cable not supplied), for device
conguration and upgrading the rmware.
d Input selection button and e
is active (current input lights green).
f Aux input LED — This LED indicates when the aux input is active for input level adjustment. g Audio input adjustment knobs and h level LEDs — The audio input adjustment knob allows the user to adjust the
level of the audio input. The associated LEDs (peak, normal, and signal) indicate the active audio level.
i VoiceLift input adjustment knobs and
the VoiceLift (microphone) input level. The associated LEDs (peak, normal and signal) indicate the active audio level.
k Paging Sensor sensitivity adjustment knob and l Status LED — The adjustment knob allows the user to adjust the
sensitivity of the Page Sensor to interrupt program audio during facility broadcasts. The status LED lights when a broadcast is detected.
Tx
Rx
MLC 104 IP Plus right side panel
Included power supply is used for both PVS 405D and MLC 104 IP Plus
AB
+12V IN
GROUND
GROUND
MLS and Power ports
MLS PWR
Figure 3. Power Supply Connections to PVS 405D and MLS 104 IP Plus
AUDIO LEVEL ADJUSTINPUTS
SELECT
R
CONFIG
3
2
1
2
3
45AUX
5
AUDIO
6
INPUT
74
PEAK
NORMAL
SIGNAL
8
VOICELIFT
PEAK
NORMAL
SIGNAL
10
9 1211
Figure 4. Front Panel Features
LEDs (1-5) — The button selects and switches inputs and the LEDs indicate which input
level LEDs — The VoiceLift level adjustment knob allows the user to adjust
j
PAGING SENSOR
SENSITIVITY
PVS 405D
POLEVAULT SWITCHER
3
PVS 405D • Setup Guide (Continued)
Front Panel Operation and Configuring the PVS 405D Switcher
For full details of front panel operation and switcher conguration, refer to the PVS 405D User Guide, and the MLC 104 IP Plus User Guide. For VoiceLift and Page Sensor installation and operation details, refer to the VoiceLift System User Guide and the Priority Page Sensor Kit Installation Instructions. All these are available online at www.extron.com.
Front Panel Operation
1. To change inputs, press the input button d to sequentially cycle through inputs 1 through 4, (video and audio), and input 5
(audio only). The LEDs this press and hold the Select button for 3 seconds until the Aux LED lights.
2. To adjust audio input levels, select an input then turn the Input encoder g through 43 positions in 1 dB steps
(-18 to +24 dB, default 0). The LEDs h indicate the signal level status (not volume).
3. To adjust VoiceLift microphone level, turn the VoiceLift i through 43 positions in 1 dB steps (-18 to +24 dB, default 0).
Front panel LEDs
j
NOTE: On initial switcher power-up the output volume level is automatically adjusted to 80%.
4. To adjust Paging sensitivity, turn the Paging encoder k clockwise to increase, and counter-clockwise to decrease sensitivity.
The status LED l illuminates when an announcement from the paging system is detected.
The Extron Priority Page Sensor Kits (PPS 35, part number 70-1064-01 or PPS 25, part number 70-619-01) are optional accessories and can be purchased separately.
Configuration
The PVS 405D switcher can be controlled by a MediaLink Controller (MLC) or by an RS-232 device acting through the MLC. The switcher can be also set up and controlled via a host computer or other device (such as a control system) attached to the rear panel RS-232 remote port of the switcher. The control device (host) can use Extron Simple Instruction Set (SIS™) commands or the Product Conguration Software (PCS) program. See pages 1 and 2 for connection details.
(inputs 1-5) indicate which input is active. The aux input is selectable for configuration only. To do
e
indicate mic input signal levels.
NOTE: Configuration can also be completed by connecting a USB cable to the mini USB config. port on the front panel
(see c in figure 3). This port uses the same protocol as the rear panel RS-232 port.
See the PVS 405D User Guide for full conguration methods using SIS commands.
See the Product Conguration Software (PCS) program embedded Help le for conguration methods using PCS.
The software and device User Guides and Instructions mentioned in this guide can be found at www.extron.com.
Extron Headquarters
+1.800.633.9876 (Inside USA/Canada Only)
Extron USA - West Extron USA - East +1.714.491.1500 +1.919.850.1000 +1.714.491.1517 FAX +1.919.850.1001 FAX
4
Extron Europe
+800.3987.6673 (Inside Europe Only)
+31.33.453.4040 +31.33.453.4050 FAX
© 2014 Extron Electronics All rights reserved. www.extron.com
Extron Asia
+65.6383.4400 +65.6383.4664 FAX
Extron Japan
+81.3.3511.7655 +81.3.3511.7656 FAX
Extron China
+86.21.3760.1568 +86.21.3760.1566 FAX
Extron Middle East
+971.4.299.1800 +971.4.299.1880 FAX
Extron Korea
+82.2.3444.1571 +82.2.3444.1575 FAX
Extron India
1800.3070.3777 (Inside India Only)
+91.80.3055.3777 +91.80.3055.3737 FAX
68-2379-50
Rev. A 01 14
Loading...