Extron Electronics P-S 100 User Manual

when power is applied and an overcurrent condition (2.0 amps or more) exists.
Continued operation in an overload condition will cause premature power supply failure.
Channel Overload LEDs — These rear panel LEDs light
5
red to indicate that an overcurrent condition (0.6 amps or more, or a short circuit) exists for the associated output. When the Channel Overload LED lights for a specific output, that output is switched off.
Specifications
Power input ............................. 100VAC to 240VAC, 50/60 Hz, 31 watts,
internal, auto-switchable
Power output .......................... (10) 12VDC outputs (maximum current of
all outputs 2.0 A )
Temperature/humidity ........ Storage -40° to +158°F (-40° to +70°C) /
10% to 90%, non-condensing Operating +32° to +113°F (0° to +45°C) /
10% to 90%, non-condensing
Rack mount ............................. Yes, with optional rack shelf, part #60-190-01
Enclosure type ........................ Metal
Enclosure dimensions ........... 1.75" H x 4.4" W x 8.5" D
4.4 cm H x 11.2 cm W x 21.6 cm D
Product weight ....................... 1.0 lbs (0.5 kg)
Shipping weight ..................... 3 lbs (1.4 kg)
Vibration .................................. ISTA/NSTA 1A in carton
(International Safe Transit Association)
Listings: .................................... UL, CUL
Compliances: ........................... CE
MTBF ........................................ 30,000 hours
Warranty .................................. 3 years parts and labor
Specifications are subject to change without notice.
User’s Guide
www.extron.com
Extron Electronics, USA
1230 South Lewis Street Anaheim, CA 92805 USA
714.491.1500 Fax 714.491.1517
Extron Electronics, Europe
© 2002 Extron Electronics. All rights reserved.
Extron Electronics, Asia
135 Joo Seng Road, #04-01 PM Industrial Building Singapore 368363 +65.6383.4400 Fax +65.6383.4664
Extron Electronics, Japan
Daisan DMJ Building 6F 3-9-1 Kudan Minami Chiyoda-ku, Tokyo 102-0074 Japan +81.3.3511.7655 Fax +81.3.3511.7656
P/S 100
Universal 12VDC Power Supply
68-527-01 Rev. C
Printed in the USA
07 02
Installation
1
2
345
- wire
+ wire
- wire
Up to 5 power supply outputs
Power connector
plastic cover
+ wire
Description
The Extron P/S 100 is a 12VDC 2.0 A universal power supply with ten separate outputs on two 10-connector, 3.5mm captive screw connectors. The outputs are rated at 12V, 200 mA each. The universal power supply can power up to ten devices that require 12VDC external power, such as some Extron interfaces and products in the VersaTools™ line of basic distribution amplifiers, switchers, and associated video accessories.
The rack mountable P/S 100 has an internal auto-switchable power supply that can accept 100VAC to 240VAC at 50 Hz to 60 Hz.
Installation
For optional rack mounting, mount up to four P/S 100s on a 19" 1U Universal Rack Shelf (Extron part #60-190-01) (figure 1).
Half rack width false front panel uses 2 front holes
Quarter Rack Width False Front Panel
Rear Panel Connections
Connect the power cables from the various devices that
1
will receive power from the P/S 100 to the 3.5mm captive screw connectors (included) (figure 2).
100-240V -
2
50/60 Hz 0.9 A MAX
3
Figure 2 — P/S 100 front and rear panels
Each captive screw connector has ten poles and can support up to five power supply outputs (figure 3).
5
1
2 3 4 5 6 7 8 9 10
4
POWER-GREEN
OVERLOAD-AMBER
CHANNEL OVERLOAD
12 VDC OUTPUT 200 mA PER CHANNEL
1
12 VDC POWER SUPPLY
P/S 100
(2) 4-40 x 3/16" screws
1 2
V
D C
P
P
/
S
O W
1
E
0
R
0
S
U
P P
L Y
Use 2 mounting holes on opposite corners
Figure 1 — Rack mounting the P/S 100
1. Mount the P/S 100 on the rack shelf, using two 4-40 x 3/16” screws in opposite (diagonal) corners.
2. If necessary, mount the half rack width false front panel (included with the Universal Rack Shelf) and/or the quarter rack width false front panel (included with the P/S 100) to the shelf, using two 4-40 x 3/16” screws in the front holes for each panel.
Figure 3 — Connecting power cables to P/S 100
2
Indications
3
4
Plug in the P/S 100.
Power LED — This front panel LED (figure 3) lights to indicate that the P/S 100 is receiving power.
Power/Overload LED — This rear panel LED lights green when power is applied and is normal, and lights amber
P/S 100 • IndicationsP/S 100 • Installation
32