Safety Instructions
Safety Instructions • English
WARNING: This symbol, , when used on the product, is intended to
alert the user of the presence of uninsulated dangerous voltage within
the product’s enclosure that may present a risk of electric shock.
ATTENTION: This symbol, , when used on the product, is intended
to alert the user of important operating and maintenance (servicing)
instructions in the literature provided with the equipment.
For information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the Extron Safety and
Regulatory Compliance Guide, part number 68-290-01, on the Extron
website,
www.extron.com.
Instructions de sécurité • Français
AVERTISSEMENT: Ce pictogramme, , lorsqu’il est utilisé sur le
produit, signale à l’utilisateur la présence à l’intérieur du boîtier
du produit d’une tension électrique dangereuse susceptible de
provoquer un choc électrique.
ATTENTION: Ce pictogramme, , lorsqu’il est utilisé sur le produit,
signale à l’utilisateur des instructions d’utilisation ou de maintenance
importantes qui se trouvent dans la documentation fournie avec le
matériel.
Pour en savoir plus sur les règles de sécurité, la conformité à la
réglementation, la compatibilité EMI/EMF, l’accessibilité, et autres sujets
connexes, lisez les informations de sécurité et de conformité Extron, réf. 68290-01, sur le site Extron,
www.extron.fr.
Sicherheitsanweisungen • Deutsch
WARNUNG: Dieses Symbol auf dem Produkt soll den Benutzer
darauf aufmerksam machen, dass im Inneren des Gehäuses dieses
Produktes gefährliche Spannungen herrschen, die nicht isoliert sind
und die einen elektrischen Schlag verursachen können.
VORSICHT: Dieses Symbol auf dem Produkt soll dem Benutzer in
der im Lieferumfang enthaltenen Dokumentation besonders wichtige
Hinweise zur Bedienung und Wartung (Instandhaltung) geben.
Weitere Informationen über die Sicherheitsrichtlinien, Produkthandhabung,
EMI/EMF-Kompatibilität, Zugänglichkeit und verwandte Themen finden Sie in
den Extron-Richtlinien für Sicherheit und Handhabung (Artikelnummer
68-290-01) auf der Extron-Website,
www.extron.de.
Instrucciones de seguridad • Español
ADVERTENCIA: Este símbolo, , cuando se utiliza en el producto,
avisa al usuario de la presencia de voltaje peligroso sin aislar dentro
del producto, lo que puede representar un riesgo de descarga
eléctrica.
ATENCIÓN: Este símbolo, , cuando se utiliza en el producto, avisa
al usuario de la presencia de importantes instrucciones de uso
y mantenimiento recogidas en la documentación proporcionada
con el equipo.
Para obtener información sobre directrices de seguridad, cumplimiento
de normativas, compatibilidad electromagnética, accesibilidad y temas
relacionados, consulte la Guía de cumplimiento de normativas y seguridad
de Extron, referencia 68-290-01, en el sitio Web de Extron,
www.extron.es.
Korean
경고: 이 기호 , 가 제품에 사용될 경우, 제품의 인클로저 내에 있는
접지되지 않은 위험한 전류로 인해 사용자가 감전될 위험이 있음을
경고합니다.
주의: 이 기호 , 가 제품에 사용될 경우, 장비와 함께 제공된 책자에 나와
있는 주요 운영 및 유지보수(정비) 지침을 경고합니다.
안전 가이드라인, 규제 준수, EMI/EMF 호환성, 접근성, 그리고 관련
항목에 대한 자세한 내용은 Extron 웹 사이트(
Extron 안전 및 규제 준수 안내서, 68-290-01 조항을 참조하십시오.
www.extron.co.kr)의
FCC Class A Notice
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part15 of the FCC rules. The ClassA limits provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and,
if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is
likely to cause interference; the user must correct the interference at his own expense.
NOTE:This unit was tested with shielded I/O cables on the peripheral devices.
Shielded cables must be used to ensure compliance with FCC emissions limits.
For more information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the “Extron Safety and Regulatory
This section gives an overview of the user guide. This section also describes the
MTP 15HD A Architectural Series of transmitters. Topics that are covered include:
•About this Guide
•About the MTP Transmitters
About this Guide
This guide contains installation, configuration, and operation information for the
Extron MTP 15HD A Architectural Series of transmitters.
About the MTP Transmitters
The Extron MTP T 15HD A Architectural Twisted Pair Transmitters (available in either black or
white) are a series of wall, Architectural Adapter Plate (AAP) or furniture mounting products
that are based on the MTP T 15HD A Twisted Pair Transmitter.
The Extron MTP T 15HD A architectural transmitters accept high resolution computer-video
on a female 15-pin HD connector and a stereo audio signal on a female 3.5 mm mini stereo
jack. The female RJ-45 output connector, mounted on a 3 inch pigtail, transmits a computer
video and summed mono audio signal to an MTP R 15HD A, MTP RL 15HD A, or
MTP RL 15HD A SEQ receiver. A pre-peaking control switch boosts the transmission
distance of the proprietary signal.
The MTP T 15HD A architectural series is part of a system for long-distance distribution of
VGA or other high resolution video and audio, over Extron Enhanced Skew-Free AV UTP
Cable, or any CAT 5, 5e, or 6 shielded twisted pair (STP), unshielded twisted pair (UTP), or
foil shielded twisted pair (FTP) cable.
Twisted Pair Cable Advantages
Twisted pair cable is smaller, lighter, more flexible, and less expensive than coaxial cable.
Termination of the cable with RJ-45 connectors is simple, quick, and economical (see
Twisted Pair Cable Termination on page 13 for wiring details).
Transmission Distance
The maximum distance is determined by the frequency and resolution of the signal that is
input to the transmitter.
See the table on page 2 for the recommended maximum transmission distances and
transmitter Pre-Peak switch positions using Extron Enhanced Skew-Free AV UTP cable or
UTP CAT 5 cable, terminated with CAT 5 rated connectors.
MTP T 15HD A Architectural Series • Introduction1
Video
Format
Pre-Peak
off
Pre-Peak onMax. Distance
(High Quality)
Max. Distance
(Variable Quality)
Composite,
S-video,
Component
640x480
800x600
1024x768*
1280x960*
1280x1024*
1360x765
1365x768
1366x768
1400x1050
1440x900
1600x1200*
1920x1200
2048x1080
HDTV 720p
HDTV 1080i
HDTV 1080p
<300'
(90 m)
<300'
(90 m)
<300'
(90 m)
<300'
(90 m)
<250'
(75 m)
<250'
(75 m)
<250'
(75 m)
<250'
(75 m)
<250'
(75 m)
<250'
(75 m)
<250'
(75 m)
<250'
(75 m)
<250'
(75 m)
<250'
(75 m)
<250'
(75 m)
<250'
(75 m)
>350'
(105 m)
>350'
(105 m)
>350'
(105 m)
>350'
(105 m)
>300'
(90 m)
>300'
(90 m)
>300'
(90 m)
>300'
(90 m)
>300'
(90 m)
>300'
(90 m)
>300'
(90 m)
>300'
(90 m)
>300'
(90 m)
>300'
(90 m)
>300'
(90 m)
>300'
(90 m)
800'
(245 m)
700'
(215 m)
550'
(165 m)
500'
(150 m)
400'
(120 m)
350'
(105 m)
400'
(120 m)
400'
(120 m)
400'
(120 m)
350'
(105 m)
350'
(105 m)
300'
(90 m)
300'
(90 m)
300'
(90 m)
400'
(120 m)
300'
(90 m)
300'
(90 m)
1000'
(300 m)
750'
(240 m)
650'
(200 m)
600'
(185 m)
500'
(150 m)
450'
(135 m)
500'
(150 m)
450'
(135 m)
450'
(135 m)
400'
(120 m)
400'
(120 m)
450'
(135 m)
400'
(120 m)
400'
(120 m)
500'
(150 m)
400'
(120 m)
400'
(120 m)
Figure 1. Recommended Pre-Peak Switch Positions and Transmission Distances
NOTES:
• Resolutions marked with an asterisk (*) in the table above have the same range
specifications at 75 Hz.
• It is possible to exceed the recommended distance, but image quality may be
reduced.
at 60 Hz
MTP T 15HD A Architectural Series • Introduction2
NOTES:
• The transmitters are for use with, and perform best with Extron Enhanced
Skew-Free AV cable terminated in accordance with the TIA/EIA T 568 A wiring
standard. CAT 5 cables are acceptable but less preferable. We also recommend
the use of pre-terminated and tested cables. Cables terminated on site should be
tested before use to ensure that they comply with Category 5 specifications.
• The recommendations shown in the table on the previous page apply for a single
transmitter connected to a MTP receiver and for a daisy chain. For example, the
maximum suggested range for 1024 x 768 video is 300 feet (90 m) with
Pre-Peak off and 500 feet (150 m) with Pre-Peak on whether the system consists
of one transmitter and one receiver or a transmitter and three daisy-chained
receivers.
About the MTP T 15HD A WM
The MTP T 15HD A WM Twisted Pair Transmitter is a wall or furniture mountable version of
the MTP T 15HD A, and can be mounted into any standard Underwriters Laboratories (UL)
listed one-gang electrical wall box or by using the included mud ring.
AUDIO IN
COMPUTER IN
MTP T 15HD A
Figure 2. MTP T 15HD A WM Face
MTP T 15HD A Architectural Series • Introduction3
About the MTP T 15HD A D
The MTP T 15HD A D Twisted Pair Transmitter is a wall or furniture mountable version of the
MTP T 15HD A that fits any Decora® style wall plate.
AUDIO IN
COMPUTER IN
Figure 3. MTP T 15HD A D Face
About the MTP T 15HD A AAP
The MTP T 15HD A AAP Twisted Pair Transmitter can be mounted in any Extron product
that accepts a double space AAP, such as the AAP 102.
Figure 4. MTP T 15HD A AAP Face
AUDIO IN
COMPUTER
IN
MTP T 15HD A
MTP T 15HD A Architectural Series • Introduction4
Installation
This section provides information on:
•Installing the MTP T 15HD A WM and MTP T 15HD A D
•Installing the MTP T 15HD A AAP
•Connections and Settings
•Power Supply Wiring and Grounding
•Twisted Pair Cable Termination
•EDID Minder Configuration
Installing the MTP T 15HD A WM and MTP T 15HD A D
The MTP T 15HD A WM and MTP T 15HD A D can be installed in a one-gang electrical wall
box, with the MTP T 15HD A D fitting into a Decora wall plate cover (supplied). If a suitable
wall box is already installed, follow steps 5 through 8 on the following page. To install a new
wall box or to install using the included mud ring, follow all the steps below. UL-listed wall
boxes are recommended.
The installation must conform to national and local electrical codes and to the size
requirements of the wall plate.
The following UL requirements pertain to the installation of the MTP T 15HD A architectural
series into a wall or furniture.
•These units are not to be connected to a centralized DC power source or used beyond
their rated voltage range.
•These units must be installed in UL-listed junction boxes.
•These units must be installed with conduit in accordance with the National Electrical
Code.
Preparing the Site and Installing the Wall Box
Choose a location that allows cable runs without interference. Allow enough depth for
both the wall box and the cables. The box should be at least 2.5 inches (6.4 cm) deep
to accommodate the connectors and cables. Install the cables into the wall, furniture, or
conduits before installing the wall plate.
1. If a wall box is not available to use for a template, use the dimensions from the template
on page 15 or download a full size template online at www.extron.com.
If installing directly into furniture, cut out the center portion of the template.
2. Place the template (or the wall box) against the installation surface, and mark the
guidelines for the opening.
3. Cut out the material from the marked area.
4. Insert the wall box into the opening. The box or the rear connectors of the wall plate
should fit easily into the opening. Enlarge or smooth the edges of the opening as
needed.
MTP T 15HD A Architectural Series • Installation5
5. With the power supply disconnected, feed cables for the output devices through the
MTP 15HD A WM
PC INPUT
AUDIO
MTP T 15HD A WM
Wall
Wall Mounting
Bracket (mud ring)
opening and through the wall box punch-out holes, securing them with cable clamps to
provide strain relief.
6. Trim back, insulate, or do both to exposed cable shields with heat shrink to reduce the
chance of short circuits.
a. To prevent short circuits, the outer foil shield can be cut back to the point where the
cable exits the cable clamp.
b. Both braided and foil shields should be connected to an equipment ground at the
other end of the cable.
7. Connect the output device cables to the rear of the MTP architectural wall plate (see
Twisted Pair Cable Termination on page 13 for connector wiring details).
8. Connect input devices (see Front Panel Features on page 9 for connector details),
restore the power supply, and test the wall plate. Make any cabling adjustments before
final installation as the cables will be inaccessible afterwards.
Installing into a Mud Ring (WM and Decora Models)
1. Using the mud ring as a guide, mark the edges and cut out the material within the
marked area.
2. Insert the mud ring into the opening, rotate the arms, and secure with the supplied
screws.
3. Follow steps 5 through 8 of Preparing the Site and Installing the Wall Box above,
and Final Installation on page 7.
Figure 5. Mounting the MTP T 15HD A WM Using the Mud Ring
MTP T 15HD A Architectural Series • Installation6
Final Installation
After testing and making any adjustments, turn off the power supply and carefully insert the
wall box or mud ring into the opening.
Attach it with nails or screws, leaving the front edge flush with the outer wall or furniture
surface (see figure 6).
NOTES:
• If attaching the wall box to wood, use four #8 or #10 screws or 10-penny nails. A
minimum of 0.5 inches (1.3 cm) of screw thread must penetrate the wood.
• If attaching the wall box to metal studs or furniture, use four #8 or #10
self-tapping sheet metal screws or machine bolts with matching nuts.
Wall Stud
Installation
Cable
Cable
Clamp
Screws
or Nails
Wall Stud
Installation
Cable
Cable
Clamp
Screws
or Nails
Figure 6. Installing the Wall Box
•If installing an MTP T 15HD A WM, mount the faceplate directly to the box or mud ring.
•If installing an MTP T 15HD A D, mount it directly to the wall box, then attach the
Decora wall plate, as shown in figure 7, and restore the power supply.
Wall Box
Wall opening
is flush with
edge of box.
Figure 7. Mounting the MTP T 15HD A D
MTP T 15HD A D
AUDIO
PC INPUT
Decora
Faceplate
MTP T 15HD A Architectural Series • Installation7
Installing the MTP T 15HD A AAP
The MTP T 15HD A AAP must be attached to a device faceplate or AAP wall plate and
cabled before the device or wall plate is pretested or installed in a wall or furniture.
1. Before attaching any cables, insert the standoffs of the MTP T 15HD A AAP through the
holes in the faceplate or AAP wall plate of the device.
2. Using the provided #4-40 nuts and captive washers, secure the AAP to the faceplate or
wall plate.
3. Repeat steps 1 and 2 to mount any other AAPs. Cover any openings in the faceplate
with blank plates (provided with the AAP faceplate).
4. Be sure to include the AAP connectors as part of the installation pretest before final
installation of the faceplate.
5. For more detailed installation information, see the installation guide shipped with the
device or AAP faceplate.
AAP 102
AUDIO IN
COMPUTER
IN
MTP T 15HD A
MTP T 15HD A AAP
AAP 102
Figure 8. Mounting the MTP T 15HD A AAP
MTP T 15HD A Architectural Series • Installation8
Connections and Settings
AUDIO IN
MTP T 15HD A
COMPUTER IN
MTP T 15HD A D
MTP T 15HD A WM
AUDIO IN
MTP T 15HD A
COMPUTER
IN
MTP T 15HD A AAP
COMPUTER IN
AUDIO IN
1
3
2
123
1
3
2
Tip
ATTENTION:Potential damage to property.
Do not connect these devices to a computer data or telecommunications network.
Front Panel Features
The front panel features are the same on all the MTP T 15HD A architectural models, as
shown in figure 9.
Figure 9. Architectural Series Front Panel Features
a Power LED — Indicates power is applied to the MTP.
Left (+)
Ring
Right (
-
)
b Audio input connector — Connect a 3.5 mm stereo audio
plug into this jack for unbalanced audio input. Wire the plug as
shown in the figure to the right.
Sleeve ( )
NOTE: The figure above shows a typical audio connector, which consists of the tip,
ring, and sleeve. The tip, ring, and sleeve wires are also shown on the captive
screw audio connector diagram (see figure 11 on page 10).
51
610
c Video input connector — Connect a computer video source to this
15-pin HD connector for high resolution video input.
NOTES:
• Input only sync signals (no video signals) on the sync pins (13 and 14).
• For component video, use the R (R-Y) and R return pins (pins 1 and 6),
G (Y) and G return pins (pins 2 and 7), and B (B-Y) and B return pins
(pins 3 and 8).
• For S-video, use the R, R return (C-chroma), G, and G return (Y-luma) pins.
• For composite video, use the G pin and the associated return pin. For
additional genlocked video signals, use the R, B, and associated return pins.
1511
Female
MTP T 15HD A Architectural Series • Installation9
Rear Panel Features
With the exceptions of d, e, and f on the MTP T 15HD A D, as noted in the figures and
descriptions, the rear panel features are the same on all the MTP T 15HD A architectural
models.
1
2
3
6
1
50ON
PRE-
OFF60
EDID
SELECT
Hz
4
5
6
2
3
PEAK
Figure 10. MTP T 15HD WM and AAP (Left) and MTP T 15HD A D (Right)
Rear Panel Features
a Output connector — Connect one end of a twisted pair cable to this RJ-45 female
connector on the transmitter. Connect the opposite end of the cable to the RJ-45
connector of the receiver (see Twisted Pair Cable Termination on page 13 to wire the
RJ-45 connectors).
b Pre-Peak switch — The Pre-Peak DIP switch boosts the video signal output to correct
for long cable runs (see the table on page 2 for suggested switch settings based on the
transmitted video format and transmission distance).
c Stereo Audio output connector — Insert bare wires into this direct insertion 3.5 mm,
5-pole captive screw audio connector for stereo audio outputs. Wire the connector as
shown in figure 11.
Do not tin the wires!
Figure 11. Captive Screw Audio Connector Wiring
Tip
Ring
Sleeves
Tip
Ring
Balanced Audio Output
LR
No Ground Here
Tip
Sleeves
Tip
No Ground Here
Unbalanced Audio Output
ATTENTION: Potential damage to property.
For unbalanced audio, connect the sleeves
to the ground contact.
DO NOT
connect the sleeves to the
negative (-) contacts.
MTP T 15HD A Architectural Series • Installation10
LR
d Frequency Select switch — The Frequency select DIP switch sets the vertical
AA
frequency of the factory-installed EDID. 50 Hz or 60 Hz can be selected.
e EDID Select rotary switch — This 16 position rotary switch is used to select which
factory-installed EDID information will be used. Position 0 is not used. Positions 1
through F correspond to the EDID information in the table in figure 15 on page 14.
f Power connector — Connect the cables from the included external 12VDC power
supply to the rear panel 3.5 mm, 2-pole captive screw connector (see figures 12 and 13
below and on the next page for wiring and grounding instructions).
To verify the polarity before connection, plug in the power supply with no load and
check the output with a voltmeter.
Power Supply Wiring and Grounding
Figure 12 shows how to wire the power connector. Figure 13 shows how to ground the unit
through the power connector.
ATTENTION: Potential damage to property.
• Power supply voltage polarity is critical. Incorrect voltage polarity can damage the
power supply and the transmitter or receiver. Identify the power cord negative lead
by the ridges on the side of the cord.
• The length of the exposed (stripped) copper wires is important. The ideal length is
3/16 inches (5 mm). Longer bare wires can short together. Shorter wires are not as
secure in the connector and could be pulled out.
To verify the polarity before connection, plug in the power supply with no load and check the
output with a voltmeter.
Smooth
Ridges
Power Supply
Output Cord
SECTION A–A
Captive Screw
Connector
3/16” (5 mm)
MAX
Smooth
Ridges
AA
Power Supply
Output Cord
SECTION A–A
Captive
Screw
Connector
3/16” (5 mm)
MAX
Figure 12. Power Connector Wiring for the MTP T 15HD WM and AAP (Left), and
the MTP T 15HD A D (Right)
Extron twisted pair products can be adversely affected by electrostatic discharge (ESD) if
they are not grounded correctly. To prevent malfunctions or product damage, an installer
can correctly ground an Extron twisted pair product by following the diagram in figure 13 on
the next page.
Ground the power port by inserting one end of the grounding wire to the negative or ground
pin on the power input connector.
MTP T 15HD A Architectural Series • Installation11
POWER
12V
0.5A MAX
Rear
Panel
3/16"
(5 mm)
MAX
Tie
Wrap
Ridges
Earth
Ground
Figure 13. Power Connector Wiring and Grounding
WARNING:Failure to follow these instructions may result in serious injury.
The two power cord wires must be kept separate while the power supply is plugged
in. Disconnect the power before wiring.
NOTES:
• Your transmitter and receiver pair may have shipped with a blue captive screw
connector. This blue connector can be plugged into either a blue or an orange
power receptacle. The blue connector does not have the extended tail or the
included tie-wrap.
• Do not tin the power supply leads before installing in the direct insertion connector.
Tinned wires are not as secure in the connectors and could be pulled out of the
connector.
ATTENTION:Potential damage to property.
• This product is intended to be supplied by a Listed Power Unit marked “Class 2”
or “LPS”, rated 12 VDC, maximum 1.0 A. Always use a power supply supplied
or specified by Extron. Use of an unauthorized power supply voids all regulatory
compliance certification and may cause damage to the supply and the end
product.
• Unless otherwise stated, the AC/DC adapters are not suitable for use in air
handling spaces or in wall cavities. The power supply is to be located within the
same vicinity as the Extron AV processing equipment in an ordinary location,
Pollution Degree 2, secured to the equipment rack within the dedicated closet,
podium, or desk.
• The installation must always be in accordance with the applicable provisions of
National Electrical Code ANSI/NFPA 70, article 75, and the Canadian Electrical
Code part 1, section 16. The power supply shall not be permanently fixed to
building structure or similar structure.
Use the supplied tie wrap to strap the power cord to the extended tail of the connector.
As an alternative, an Extron PS 124 Universal 12 VDC Power Supply can power multiple
MTPs or other Extron 12 VDC devices using only one AC power connector.
MTP T 15HD A Architectural Series • Installation12
Twisted Pair Cable Termination
Pins:
nS
1R
2R
Figure 14 details the recommended termination of twisted pair cables with RJ-45
connectors in accordance with the TIA/EIA T568A or TIA/EIA T568B wiring standards. You
can use either standard with CAT 5, 5e, or 6 cable, but ensure that you use the same standard on both ends of the cable.
12345678
Insert Tw isted
Pair Wires
RJ-45
Connector
Figure 14. Twisted Pair Cable Termination Diagram
NOTES:
• RJ-45 termination with CAT 5, 5e, or 6 cable must comply with the TIA/EIA T568A
or TIA/EIA T568B wiring standards for all connections.
• RJ-45 termination with Skew-Free AV UTP cable must comply with TIA/EIA T568A
only.
• The audio data that is carried on wire pair 3 and 6 is incompatible with the Extron
TPX 88 A, which cannot switch the audio, output it locally, or break it away.
• Extron Enhanced Skew-Free AV cable is not recommended for
Ethernet or LAN applications. This cable is specially designed for compatibility with
Extron Twisted Pair products that are wired using the TIA/EIA T568A standard.
TIA/EIA T 568 ATIA/EIA T 568 B
Pi
White-green
Green
White-orange
3
Blue
4
White-blue
5
Orange
6
White-brown
7
Brown
8
Wire color
Wire color
White-orange
Orange
White-green
Blue
White-blue
Green
White-brown
Brown
ignal
ed/V. sync +
ed/V. sync -
Mono audio +
Green +
Green -
Mono audio -
Blue/H. sync +
Blue/H. sync -
NOTE: When using Enhanced Skew-Free
AV UTP cable, use the TIA/EIA T568A
standard only.
• The green, brown, and blue wire pairs of this cable have virtually identical
• The orange wire pair of this cable has a different length and should not be used
lengths and should be used to transmit the RGB signals.
to transmit the RGB signals.
MTP T 15HD A Architectural Series • Installation13
EDID Minder Configuration
The MTP T 15HD A D unit supports emulation of factory-installed EDID information through
EDID Minder.
To use factory-installed EDID information:
1. If you have not already done so, connect the source device to the MTP 15HD
transmitter. Do not power on the source device at this time.
2. Set the rear panel DIP switch (see d on page 11) to the required frequency (50 or
60 Hz).
NOTE: When the rotary dial (see
DIP switch position is ignored.
3. Set the rotary dial (see e on page 11) to the required position (see figure 15 for specific
EDID and its corresponding rotary switch position).
Positions 1 through F are factory installed. Position 0 is not used.
Rotary Switch
Position
0Not used
1800x600
21024x768 (default)
31280x720
41280x768
51280x800
61280x1024
71360x768
81366x768
91400x1050
A1400x900
B1600x900
C1600x1200
D1680x1050
E1920x1080
F1920x1200
Resolution
on page 11) is set to position 0, the frequency
e
Figure 15. EDID Settings Table
MTP T 15HD A Architectural Series • Installation14
Reference
Information
This section includes a template with cut-out dimensions for installation of the MTP T 15HD
A WM or MTP T 15HD A D transmitter.
Decora Template Dimensions
Use the dimensions in the cut-out template in figure 16 as a guide for cutting a hole in a wall
or furniture.
NOTES:
• The drawing is not full size or to scale. DO NOT scale up or print to use as a
template.
• Full size templates are available online at www.extron.com.
4.50"
(11.43 cm)
2.79"
(7.09 cm)
1.9"
(4.83 cm)
2.8"
(7.1 cm)
SURFACE CUT-OUT
AREA FOR
FURNITURE MOUNT
To p
Panel
To install a
1-gang
MTP T 15HD A WM
directly into
furniture or
wall, cut along
this line.
Figure 16. 1-gang Cut-out Template
MTP T 15HD A Architectural Series • Reference Information15
Extron Warranty
Extron Electronics warrants this product against defects in materials and workmanship for a period of three years
from the date of purchase. In the event of malfunction during the warranty period attributable directly to faulty
workmanship and/or materials, Extron Electronics will, at its option, repair or replace said products or components,
to whatever extent it shall deem necessary to restore said product to proper operating condition, provided that it is
returned within the warranty period, with proof of purchase and description of malfunction to:
USA, Canada, South America,
and Central America:
Extron Electronics
1230 South Lewis Street
Anaheim, CA 92805
U.S.A.
Europe and Africa:
Extron Europe
Hanzeboulevard 10
3825 PH Amersfoort
The Netherlands
Japan:
Extron Electronics, Japan
Kyodo Building, 16 Ichibancho
Chiyoda-ku, Tokyo 102-0082
Japan
China:
Extron China
686 Ronghua Road
Songjiang District
Shanghai 201611
China
Asia:
Extron Asia Pte Ltd
135 Joo Seng Road, #04-01
PM Industrial Bldg.
Singapore 368363
Middle East:
Extron Middle East
Dubai Airport Free Zone
F12, PO Box 293666
United Arab Emirates, Dubai
Singapore
This Limited Warranty does not apply if the fault has been caused by misuse, improper handling care, electrical
or mechanical abuse, abnormal operating conditions, or if modifications were made to the product that were not
authorized by Extron.
NOTE: If a product is defective, please call Extron and ask for an Application Engineer to receive an RA (Return
Authorization) number. This will begin the repair process.
USA: 714.491.1500 or 800.633.9876 Europe: 31.33.453.4040
Asia: 65.6383.4400 Japan: 81.3.3511.7655
Units must be returned insured, with shipping charges prepaid. If not insured, you assume the risk of loss or damage
during shipment. Returned units must include the serial number and a description of the problem, as well as the
name of the person to contact in case there are any questions.
Extron Electronics makes no further warranties either expressed or implied with respect to the product and its quality,
performance, merchantability, or fitness for any particular use. In no event will Extron Electronics be liable for direct,
indirect, or consequential damages resulting from any defect in this product even if Extron Electronics has been
advised of such damage.
Please note that laws vary from state to state and country to country, and that some provisions of this warranty may
not apply to you.
Extron Headquarters
+1.800.633.9876 (Inside USA/Canada Only)
Extron USA - West Extron USA - East
+1.714.491.1500 +1.919.850.1000
+1.714.491.1517 FAX +1.919.850.1001 FAX