This guide provides basic instructions for an experienced installer to set up and operate an Extron MTP DA4 or DA8 distribution amplier.
Pre-installation — Jumpers
See the gure at the right or see “Termination and Mute Jumpering” in the MTP DA4 and MTP DA8 User Guide for more information.
Mute
(Default)
NOTE: The jumpers have no effect when the DA is part of an MTP CV/SV
series, or VTT001/VTR001 system.
Serial
or
J3
Audio
(Default)
Jumper J3
This sets the DA to properly terminate RGB video as well as the audio (default) or serial portion of the input signal.
Jumper J9
This sets the DA to always pass the audio or serial link regardless of the contact closure mute status (default). It can also be set to mute the audio or serial link when its video mute function is activated.
Installation
Step 1 — Mounting
Turn off or disconnect all equipment power sources and mount the MTP DA as required. A mounting example is shown below). See “Mounting” in the user guide for more mounting options.
6" Deep Rack Shelf
or
J9
Enable
Mute
1/2 Rack Width False Front Face Plate
(2) 4-40 x 3/16" screws
MTP DA SERIES
Use 2 mounting holes on opposite corners.
Figure 1. Mounting the MTP DA
Step 2 — Input from the Transmitter
Terminate a TP cable as shown in gure 3. Connect the cable into a MTP transmitter and into the AV input connector.
Step 3 — Outputs to the Receivers
Terminate up to four or eight (depending on model) TP cables as shown in the gure to the right. Connect the cables into the DA AV output ports and into receivers that are compatible with the transmitter.
NOTES:
• The inputs and outputs should be terminated using the same standard on both
ends of the cable.
• Only use the TIA/EIA T568A standard when using Enhanced Skew-Free™ AV
cable.
Pins:
12345678
Insert Twisted
Pair Wires
RJ-45
Connector
A/V INPUT
1234
T568A T568B
Pin
Wire color
1
White-green
2
Green
3
White-orange Blue Blue
4
White-blue
5
Orange
6
White-brown
7
Brown
8
A/V OUTPUTS
Wire color
White-orange Orange White-green
White-blue Green White-brown Brown
MTP DA4 and DA8 • Setup Guide
AA
MTP DA8
Step 4 — Power
Wire the 2-pole captive screw connector for the external 12 VDC power supply
Smooth
Ridges
(see the image on the right).
Grounding the Power Input Port
Extron MTP DA products can be adversely affected by electrostatic discharge (ESD) if they are not grounded correctly.
To prevent malfunctions or product damage, an experienced installer can correctly
3/16" (5 mm) Max.
ground an Extron MTP DA product by inserting one end of the grounding wire to the negative or ground pin on the power input connector (see the image on the right). Tie the other end of the wire to an earth ground.
Plug the connector into the MTP DA.
SECTION A–A
Power Supply
Output Cord
If you have any questions about how to ground a product in a specic application, contact an Extron technical support specialist.
Operation — Mutes
To mute an output, tie the Output Mute pin to the ground ( ). To mute all outputs, tie the A pin to the ground (see gure 2 for more information).
DVD
Output Mute Connector
1234 5678A
MTP DA4
Output Mute Connector
1 234A
Pin Contact
Function
Closure
1 Out #1 Mute output #1
2 Out #2 Mute output #2
3 Out #3 Mute output #3
4 Out #4 Mute output #4
5 Out #5 Mute output #5
6 Out #6 Mute output #6
7 Out #7 Mute output #7
8 Out #8 Mute output #8
A Out All Mute all output
Gnd Ground
Extron MTP T AV RCA
Twisted Pair Transmitter
INPUT
L R
12V
0.5a MAX
VIDEO
OUTPUT
MTP T SV A RCA
INPUT
-
+
POWER
12V
0.5A MAX
TP Cable
Extron MTP DA8
Twisted Pair Distribution Amplier
OUTPUT MUTE
A 8
7
6
5
4
3
2
1
5 6 7 8 OUTPUTS 4
3
1 2
Up To 8 Receivers
TP Cable
Extron MTP R AV
Twisted Pair Receivers
R
OUTPUT
L
SHARP
MTP R SV A
INPUT VIDEO
MAX 12V
0.5a
OUTPUT
L R
SHARP
VIDEO
MTP R SV A
INPUT
MAX 12V
0.5a
OUTPUT
L R
SHARP
VIDEO
MTP R SV A
INPUT
MAX 12V
0.5a
R
OUTPUT
L
SHARP
VIDEO
MTP R SV A
INPUT
MAX 12V
0.5a
Flat Panel Display
POWER 12V xA MAX
Rear Panel
Tie Wrap
Ridges
Earth Ground
Figure 2. Mute Connector and Pinout Figure 3. Example of a Typical MTP DA8 Application
Extron Headquarters +800.633.9876 Inside USA/Canada Only
Extron USA - West Extron USA - East +1.714.491.1500 +1.919.850.1000 +1.714.491.1517 FAX +1.919.850.1001 FAX
Extron Europe +800.3987.6673 Inside Europe Only
+31.33.453.4040 +31.33.453.4050 FAX
Extron Asia +800.7339.8766 Inside Asia Only
+65.6383.4400 +65.6383.4664 FAX
Extron Japan
+81.3.3511.7655 +81.3.3511.7656 FAX
Extron China +4000.EXTRON +4000.398766 Inside China Only
+86.21.3760.1568 +86.21.3760.1566 FAX
Extron Middle East
+971.4.299.1800 +971.4.299.1880 FAX
Extron Korea
+82.2.3444.1571 +82.2.3444.1575 FAX
Extron India
1800.3070.3777 Inside India Only
+91-80-3055.3777 +91 80 3055 3737 FAX
68-975-50 Rev. D
© 2013 Extron Electronics All rights reserved. www.extron.com
01 13
Loading...