Extron electronics MTP 4T 15HD RS Setup Manual

IMPORTANT:
Go to www.extron.com for the complete
user guide, installation instructions, and
specifications before connecting the
product to the power source.
MTP 4T 15HD RS • Setup Guide
This sheet provides quick start instructions for an experienced installer to set up and operate the MTP 4T 15HD RS multiple VGA video and RS-232 transmitters.
NOTE: Each MTP 4T 15HD RS transmitter requires at least one connected
compatible MTP receiver. Additional receivers can be daisy chained.
Installation
Step 1 — Mounting
Turn off or disconnect all equipment power sources and mount the unit as required.
Step 2 — Transmitter Inputs
INPUT
Tx Rx
RS-232
MONITOR
• Connect a computer (VGA) video source to each Input
connector.
• Connect a VGA monitor to each Monitor connector.
• Plug an RS-232 device into each RS-232 port. Wire the
connectors as shown below.
Ground
Tx
Rx
Gnd
Receive
Tr ansmit
Connected
RS-232
Device Pins
MTP Pins
Step 3 — TP Cables
Terminate up to four TP cables as shown below. Connect them between each transmitter’s Output port and a receiver’s Input port (both ends need to match).
5
1 2 3
6 7 8
4
Wire Color
White-green Green White-orange
White-blue Orange
White-brown Brown
Wire Color
T568A T568B
White-orange Orange White-green
White-blue Green
White-brown
Brown
Blue Blue
Insert TP Wires
Pins:
1 2345678
Pin
NOTE: If you are using Enhanced Skew-Free™ AV cable, use the TIA/EIA T568A standard only.
MTP 4T 15HD RS Setup Guide
This sheet provides quick start instructions for an experienced installer to set up and operate the MTP 4T 15HD RS multiple VGA video and RS-232 transmitters.
NOTE: Each MTP 4T 15HD RS transmitter requires at least one connected
compatible MTP receiver. Additional receivers can be daisy chained.
Installation
Step 1 Mounting
Turn off or disconnect all equipment power sources and mount the unit as required.
Step 2 Transmitter Inputs
Connect a computer (VGA) video source to each Input
connector.
Connect a VGA monitor to each Monitor connector.
Plug an RS-232 device into each RS-232 port. Wire the
connectors as shown below.
Connected
RS-232
Device Pins
Step 3 TP Cables
Terminate up to four TP cables as shown below. Connect them between each transmitter’s Output port and a receiver’s Input port (both ends need to match).
5
1 2 3
6 7 8
4
Insert TP Wires
Pins:
1 2345678
Pin
NOTE: If you are using Enhanced Skew-Free™ AV cable, use the TIA/EIA T568A standard only.
MTP 4T 15HD RS • Setup Guide (Continued) MTP 4T 15HD RS Setup Guide (Continued)
68-1398-50
Rev. B 01 13
Extron Headquarters +800.633.9876 Inside USA/Canada Only
Extron USA - West Extron USA ­East
+1.714.491.1500 +1.919.850.1000 FAX: +1.714.491.1517 +1.919.850.1001
Extron Europe
+800.3987.6673
Inside Europe Only
+31.33.453.4040
FAX:
+31.33.453.4050
Extron Asia +800.7339.8766
Inside Asia Only
+65.6383.4400
FAX:
+65.6383.4664
Extron Japan +81.3.3511.7655 FAX +81.3.3511.7656
Extron Middle East +971.4.2991800
FAX:
+971.4.2991880
Extron China +4000.EXTRON +4000.398766
Inside China Only
+86.21.3760.1568
FAX:
+86.21.3760.1566
Extron India
1800.3070.3777
Inside India Only
+91-80-3055.3777 +91 80 3055 3737
FAX
Extron Korea +82.2.3444.1571 +82.2.3444.1575 FAX
© 2013 Extron Electronics All rights reserved. www.extron.com
Extron Headquarters +800.633.9876 Inside USA/Canada Only
Extron USA - West Extron USA - East
+1.714.491.1500 +1.919.850.1000 FAX: +1.714.491.1517 +1.919.850.1001
Step 4 — Power
Plug a standard IEC power cord between the unit’s power connector and 100 VAC to 240 VAC, 50 or 60 Hz power source (see Ground guidelines below to ground an Extron MTP 4T 15HD RS).
NOTE: See the MTP 15HD RS User’s Guide and the MTP 15HD RS Setup Guide
to setup and operate the receivers.
INPUT
Tx
Rx
RS-232
MONITOR
OUTPUT
PRE-PEAK
ON
OFF
INPUT
Tx
Rx
RS-232
MONITOR
OUTPUT
PRE-PEAK
ON
OFF
INPUT
Tx
Rx
RS-232
MONITOR
OUTPUT
PRE-PEAK
ON
OFF
INPUT
Tx
Rx
RS-232
MONITOR
OUTPUT
PRE-PEAK
ON
OFF
MTP T 15 HD RS 1
MTP T 15 HD RS 2
MTP T 15 HD RS 3
MTP T 15 HD RS 4
INPUT
BUFFERED
OUTPUT
OUTPUT
POWER
12V .5A MAX
MTP R L 1 5HD R S
ON
1 2 3 4 5 6
H SYNC +
V SYNC +
C SYNC
SOG
VIDEO
END UNIT
RS-232
Tx
Rx
Extron MTP 4T 15HD RS
4 Mini Twisted Pair Transmitters
RS-232
RS-232
PC
Touchscreen with RS-232 Control
Extron MTP RL 15HD RS
Mini Twisted Pair Receiver
TP Cable Up to 500 feet
Grounding guidelines
Extron MTP 4T 15HD RS products can be adversely affected by electrostatic discharge (ESD) if they are not grounded correctly.
To prevent malfunctions or product damage, an experienced installer can correctly ground an Extron MTP 4T15HD RS product by grounding the chassis using a connector hex nut as shown on the right. Tie the other end of the wire to an earth ground.
If you have any questions about how to ground a product in a specic application, contact an Extron technical support specialist.
Step 4 Power
Plug a standard IEC power cord between the unit’s power connector and 100 VAC to 240 VAC, 50 or 60 Hz power source (see Ground guidelines below to ground an Extron MTP 4T 15HD RS).
NOTE: See the MTP 15HD RS User’s Guide and the MTP 15HD RS Setup Guide
to setup and operate the receivers.
RS-232
Grounding guidelines
Extron MTP 4T 15HD RS products can be adversely affected by electrostatic discharge (ESD) if they are not grounded correctly.
To prevent malfunctions or product damage, an experienced installer can correctly ground an Extron MTP 4T15HD RS product by grounding the chassis using a connector hex nut as shown on the right. Tie the other end of the wire to an earth ground.
If you have any questions about how to ground a product in a specic application, contact an Extron technical support specialist.
Loading...