High Resolution Video and Serial Link
MTP Transmitters and Receivers
User Guide
Twisted Pair
68-2206-01 Rev. C
04 14
Safety Instructions
Safety Instructions • English
WARNING: This symbol, , when used on the product, is intended to
alert the user of the presence of uninsulated dangerous voltage within the
product’s enclosure that may present a risk of electric shock.
ATTENTION: This symbol, , when used on the product, is intended
to alert the user of important operating and maintenance (servicing)
instructions in the literature provided with the equipment.
For information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the Extron Safety and
Regulatory Compliance Guide, part number 68-290-01, on the Extron website,
www.extron.com.
Instructions de sécurité • Français
AVERTISSEMENT: Ce pictogramme, , lorsqu’il est utilisé sur le
produit, signale à l’utilisateur la présence à l’intérieur du boîtier du produit
d’une tension électrique dangereuse susceptible de provoquer un choc
électrique.
ATTENTION: Ce pictogramme, , lorsqu’il est utilisé sur le produit, signale
à l’utilisateur des instructions d’utilisation ou de maintenance importantes
qui se trouvent dans la documentation fournie avec le matériel.
Pour en savoir plus sur les règles de sécurité, la conformité à la réglementation,
la compatibilité EMI/EMF, l’accessibilité, et autres sujets connexes, lisez les
informations de sécurité et de conformité Extron, réf. 68-290-01, sur le site
Extron, www.extron.com.
Sicherheitsanweisungen • Deutsch
WARNUNG: Dieses Symbol auf dem Produkt soll den Benutzer darauf
aufmerksam machen, dass im Inneren des Gehäuses dieses Produktes
gefährliche Spannungen herrschen, die nicht isoliert sind und die einen
elektrischen Schlag verursachen können.
VORSICHT: Dieses Symbol auf dem Produkt soll dem Benutzer in der
im Lieferumfang enthaltenen Dokumentation besonders wichtige Hinweise
zur Bedienung und Wartung (Instandhaltung) geben.
Weitere Informationen über die Sicherheitsrichtlinien, Produkthandhabung,
EMI/EMF-Kompatibilität, Zugänglichkeit und verwandte Themen finden Sie in
den Extron-Richtlinien für Sicherheit und Handhabung (Artikelnummer
68-290-01) auf der Extron-Website, www.extron.com.
Инструкция по технике безопасности • Русский
ПРЕДУПРЕЖДЕНИЕ: Данный символ, , если указан на продукте,
предупреждает пользователя о наличии неизолированного опасного напряжения
внутри корпуса продукта, которое может привести к поражению электрическим
током.
ВНИМАНИЕ: Данный символ, , если указан на продукте,
предупреждает пользователя о наличии важных инструкций
по эксплуатации и обслуживанию в руководстве,
прилагаемом к данному оборудованию.
Для получения информации о правилах техники безопасности,
соблюдении нормативных требований, электромагнитной
совместимости (ЭМП/ЭДС), возможности доступа и других
вопросах см. руководство по безопасности и соблюдению
нормативных требований Extron на сайте Extron: www.extron.com,
номер по каталогу - 68-290-01.
ADVERTENCIA: Este símbolo, , cuando se utiliza en el producto,
avisa al usuario de la presencia de voltaje peligroso sin aislar dentro del
producto, lo que puede representar un riesgo de descarga eléctrica.
ATENCIÓN: Este símbolo, , cuando se utiliza en el producto, avisa
al usuario de la presencia de importantes instrucciones de uso y
mantenimiento recogidas en la documentación proporcionada con el
equipo.
Para obtener información sobre directrices de seguridad, cumplimiento
de normativas, compatibilidad electromagnética, accesibilidad y temas
relacionados, consulte la Guía de cumplimiento de normativas y seguridad de
Extron, referencia 68-290-01, en el sitio Web de Extron, www.extron.com.
주의: 이 기호 가 제품에 사용될 경우, 장비와 함께 제공된 책자에 나와 있는 주요 운영 및
유지보수(정비) 지침을 경고합니다.
안전 가이드라인, 규제 준수, EMI/EMF 호환성, 접근성, 그리고 관련 항목에
대한 자세한 내용은 Extron 웹 사이트(www.extron.com)의 Extron 안전 및
규제 준수 안내서, 68-290-01 조항을 참조하십시오.
ii
FCC Class A Notice
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part15 of the FCC rules. The ClassA limits provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and,
if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is
likely to cause interference. This interference must be corrected at the expense of the user.
NOTE:This unit was tested with shielded I/O cables on the peripheral devices.
Shielded cables must be used to ensure compliance with FCC emissions limits.
For more information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the “Extron Safety and Regulatory
Compliance Guide” on the Extron website.
Conventions Used in this Guide
Notifications
The following notifications are used in this guide:
CAUTION: A caution indicates a situation that may result in minor injury.
ATTENTION: Attention indicates a situation that may damage or destroy the product or
associated equipment.
NOTE: A note draws attention to important information.
Specifications Availability
Product specifications are available on the Extron website, www.extron.com.
•MTP C7 [CAT 7, C7] products that are compatible with Shielded Twisted Pair 201
(STP201) or CAT 7 cable only.
In this guide, any reference to these products refers to either family, unless explicitly stated.
NOTE: For clarity and where applicable, in this guide, the CAT 5, 5e, 6 versions are
referred to as non-C7 MTPs.
This guide details the installation and operation of the following products:
•MTP T 15HD A twisted pair (TP) transmitter
•MTP RL 15HD A receiver with loop-through
•MTP RL 15HD A SEQ receiver with loop-through and skew equalization
In this guide:
•The term "transmitter" refers specifically to the MTP T 15HD A transmitter.
•The term "receiver" refers to either of the receiver models — the MTP RL 15HD A or
MTP RL 15HD A SEQ.
•The term "SEQ receiver" refers specifically to the MTP RL 15HD A SEQ receiver with
skew equalization capabilities.
MTP 15HD A Series • Introduction1
About the MTP Transmitters and Receivers
The Extron MTP T 15HD A transmitter and MTP RL 15HD A and MTP RL 15HD A SEQ
receivers are a system for long-distance distribution of VGA or other high resolution video
and audio.
The MTPs are a part of the Extron compact line of basic distribution amplifiers, switchers,
transmitters and receivers, and associated video accessories.
High resolution video on a 15-pin HD connector as well as stereo audio on a 3.5 mm stereo
jack is sent to the MTP transmitter. The transmitter sums the left and right audio channels
to convert the audio to mono (L+R) format. The MTP T then converts the input video and
mono audio signals to proprietary signals and outputs them to the compatible MTP receiver
on an RJ-45 connector. A pre-peaking control allows you to boost the transmission distance
of the proprietary signal. The transmitter also makes the input video available for local use
on a 15-pin HD connector.
The transmitted proprietary signal is sent to the receiver on an RJ-45 connector and is
converted back into its high resolution video and mono audio components. The receiver
auto-detects the incoming video format, enabling the signal to be output on the appropriate
pins of the 15-pin HD connector, while the two sets of identical mono audio signals are
output on a single 3.5 mm captive screw connector (A series only; RS series outputs on an
RS-232 connection).
The receiver also buffers the proprietary input signal and sends it to another compatible
MTP receiver or to a daisy chain of receivers.
NOTES:
• The transmitter provides pre-peaking, which boosts the signal before it is
transmitted. The buffered output on the receiver does not provide any
pre-peaking control. The total recommended distance (see the table on page 4)
for an entire daisy chain is the same as for a single transmitter and receiver. The
Pre-Peak switch on the transmitter has the same effect on the recommended
transmission distance for a daisy chain as for a single transmitter and receiver.
• Up to eight receivers can be connected in series using Buffered Output connectors,
provided that the total distance from the twisted pair output of the transmitter to
the last receiver in the chain does not exceed the recommended distance for the
resolution being used.
The SEQ receiver also corrects the skew delay commonly encountered when CAT 5, 5e, 6,
7, or STP201 cables are used for RGB video, component video, and S-video transmission.
NOTE: An SEQ receiver should not be necessary when Extron Enhanced Skew-Free AV
UTP cable and non-C7 transmitters and receivers are used.
Each MTP transmitter and receiver model is shipped with an external desktop 12 V power
supply that accepts 100 VAC to 240 VAC, 50-60 Hz input.
Twisted Pair Cable Advantages
Twisted pair cable is smaller, lighter, more flexible, and less expensive than coaxial cable.
Termination of the cable with RJ-45 connectors is simple, quick, and economical.
MTP 15HD A Series • Introduction2
Transmission Distance
The maximum distance is determined by the frequency and resolution of the signal that
is input to the transmitter. The table on page 4 specifies the recommended maximum
transmission distances and transmitter Pre-Peak switch positions (see E on page 10) using
Extron Enhanced Skew-Free AV UTP cable, STP201 cable, or CAT 5, 5e, 6, or 7 cable,
terminated with RJ-45 connectors.
NOTES:
• The transmitter and receiver are designed for and perform best with
Extron Enhanced Skew-Free AV UTP cable terminated in accordance with the
TIA/EIA T 568 A wiring standard. CAT 5, 5e, and 6 cables are acceptable, but less
preferable. We also recommend the use of pre-terminated and tested cables. Cables
terminated on site should be tested before use to ensure that they comply with
Category 5 specifications.
• The recommendations shown in the table on page 4 apply for a single transmitter
and receiver and for a daisy chain. For example, the maximum suggested range for
1024 x 768 video is 300 feet (90 m) with the Pre-Peak switch off and 500 feet
(150 m) with the Pre-Peak switch on, whether the system consists of one transmitter
and one receiver or a transmitter and three daisy-chained receivers.
• Extron recommends using at least 25 feet of twisted pair cable between the
transmitter and the first receiver.
• For daisy-chained units, the first receiver in the chain must be at least
100 feet (30 m) from the transmitter when the Pre-Peak switch is on.
• For daisy-chained units, any receiver in the chain closer than 350 feet (105 m) may
experience some form of over-peaking when the Pre-Peak switch is on.
An over-peaked image may appear bloomed.