This symbol is intended to alert the user of important operating and maintenance
(servicing) instructions in the literature provided with the equipment.
This symbol is intended to alert the user of the presence of uninsulated dangerous
voltage within the product’s enclosure that may present a risk of electric shock.
Caution
Read Instructions • Read and understand all safety and operating instructions before using the equipment.
Retain Instructions • The safety instructions should be kept for future reference.
Follow Warnings • Follow all warnings and instructions marked on the equipment or in the user information.
Avoid Attachments • Do not use tools or attachments that are not recommended by the equipment
manufacturer because they may be hazardous.
Consignes de Sécurité • Français
Ce symbole sert à avertir l’utilisateur que la documentation fournie avec le
matériel contient des instructions importantes concernant l’exploitation et la
maintenance (réparation).
Ce symbole sert à avertir l’utilisateur de la présence dans le boîtier de l’appareil
de tensions dangereuses non isolées posant des risques d’électrocution.
Attention
Lire les instructions• Prendre connaissance de toutes les consignes de sécurité et d’exploitation avant d’utiliser
le matériel.
Conserver les instructions• Ranger les consignes de sécurité afin de pouvoir les consulter à l’avenir.
Respecter les avertissements • Observer tous les avertissements et consignes marqués sur le matériel ou
présentés dans la documentation utilisateur.
Eviter les pièces de xation • Ne pas utiliser de pièces de fixation ni d’outils non recommandés par le fabricant
du matériel car cela risquerait de poser certains dangers.
Sicherheitsanleitungen • Deutsch
Dieses Symbol soll dem Benutzer in der im Lieferumfang enthaltenen
Dokumentation besonders wichtige Hinweise zur Bedienung und Wartung
(Instandhaltung) geben.
Dieses Symbol soll den Benutzer darauf aufmerksam machen, daß im Inneren
des Gehäuses dieses Produktes gefährliche Spannungen, die nicht isoliert sind
und die einen elektrischen Schock verursachen können, herrschen.
Achtung
Lesen der Anleitungen • Bevor Sie das Gerät zum ersten Mal verwenden, sollten Sie alle Sicherheits-und
Bedienungsanleitungen genau durchlesen und verstehen.
Aufbewahren der Anleitungen • Die Hinweise zur elektrischen Sicherheit des Produktes sollten Sie
aufbewahren, damit Sie im Bedarfsfall darauf zurückgreifen können.
Befolgen der Warnhinweise • Befolgen Sie alle Warnhinweise und Anleitungen auf dem Gerät oder in der
Benutzerdokumentation.
Keine Zusatzgeräte • Verwenden Sie keine Werkzeuge oder Zusatzgeräte, die nicht ausdrücklich vom Hersteller
empfohlen wurden, da diese eine Gefahrenquelle darstellen können.
Instrucciones de seguridad • Español
Este símbolo se utiliza para advertir al usuario sobre instrucciones importantes
de operación y mantenimiento (o cambio de partes) que se desean destacar en
el contenido de la documentación suministrada con los equipos.
Este símbolo se utiliza para advertir al usuario sobre la presencia de elementos
con voltaje peligroso sin protección aislante, que puedan encontrarse dentro
de la caja o alojamiento del producto, y que puedan representar riesgo de
electrocución.
Precaucion
Leer las instrucciones • Leer y analizar todas las instrucciones de operación y seguridad, antes de usar el
equipo.
Conservar las instrucciones • Conservar las instrucciones de seguridad para futura consulta.
Obedecer las advertencias • Todas las advertencias e instrucciones marcadas en el equipo o en la
documentación del usuario, deben ser obedecidas.
Evitar el uso de accesorios • No usar herramientas o accesorios que no sean especificamente recomendados
por el fabricante, ya que podrian implicar riesgos.
Power sources • This equipment should be operated only from the power source indicated on the product. This
equipment is intended to be used with a main power system with a grounded (neutral) conductor. The third
(grounding) pin is a safety feature, do not attempt to bypass or disable it.
Power disconnection • To remove power from the equipment safely, remove all power cords from the rear of the
equipment, or the desktop power module (if detachable), or from the power source receptacle (wall plug).
Power cord protection • Power cords should be routed so that they are not likely to be stepped on or pinched by
items placed upon or against them.
Servicing • Refer all servicing to qualified service personnel. There are no user-serviceable parts inside. To prevent
the risk of shock, do not attempt to service this equipment yourself because opening or removing covers may
expose you to dangerous voltage or other hazards.
Slots and openings • If the equipment has slots or holes in the enclosure, these are provided to prevent
overheating of sensitive components inside. These openings must never be blocked by other objects.
Lithium battery • There is a danger of explosion if battery is incorrectly replaced. Replace it only with the same or
equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s
instructions.
Avertissement
Alimentations• Ne faire fonctionner ce matériel qu’avec la source d’alimentation indiquée sur l’appareil. Ce
matériel doit être utilisé avec une alimentation principale comportant un fil de terre (neutre). Le troisième
contact (de mise à la terre) constitue un dispositif de sécurité : n’essayez pas de la contourner ni de la
désactiver.
Déconnexion de l’alimentation• Pour mettre le matériel hors tension sans danger, déconnectez tous les cordons
d’alimentation de l’arrière de l’appareil ou du module d’alimentation de bureau (s’il est amovible) ou encore de
la prise secteur.
Protection du cordon d’alimentation • Acheminer les cordons d’alimentation de manière à ce que personne ne
risque de marcher dessus et à ce qu’ils ne soient pas écrasés ou pincés par des objets.
Réparation-maintenance • Faire exécuter toutes les interventions de réparation-maintenance par un technicien
qualifié. Aucun des éléments internes ne peut être réparé par l’utilisateur. Afin d’éviter tout danger
d’électrocution, l’utilisateur ne doit pas essayer de procéder lui-même à ces opérations car l’ouverture ou le
retrait des couvercles risquent de l’exposer à de hautes tensions et autres dangers.
Fentes et orices • Si le boîtier de l’appareil comporte des fentes ou des orifices, ceux-ci servent à empêcher les
composants internes sensibles de surchauffer. Ces ouvertures ne doivent jamais être bloquées par des objets.
Lithium Batterie • Il a danger d’explosion s’ll y a remplacment incorrect de la batterie. Remplacer uniquement
avec une batterie du meme type ou d’un ype equivalent recommande par le constructeur. Mettre au reut les
batteries usagees conformement aux instructions du fabricant.
Vorsicht
Stromquellen • Dieses Gerät sollte nur über die auf dem Produkt angegebene Stromquelle betrieben werden.
Dieses Gerät wurde für eine Verwendung mit einer Hauptstromleitung mit einem geerdeten (neutralen) Leiter
konzipiert. Der dritte Kontakt ist für einen Erdanschluß, und stellt eine Sicherheitsfunktion dar. Diese sollte nicht
umgangen oder außer Betrieb gesetzt werden.
Stromunterbrechung • Um das Gerät auf sichere Weise vom Netz zu trennen, sollten Sie alle Netzkabel aus der
Rückseite des Gerätes, aus der externen Stomversorgung (falls dies möglich ist) oder aus der Wandsteckdose
ziehen.
Schutz des Netzkabels • Netzkabel sollten stets so verlegt werden, daß sie nicht im Weg liegen und niemand
darauf treten kann oder Objekte darauf- oder unmittelbar dagegengestellt werden können.
Wartung • Alle Wartungsmaßnahmen sollten nur von qualiziertem Servicepersonal durchgeführt werden. Die
internen Komponenten des Gerätes sind wartungsfrei. Zur Vermeidung eines elektrischen Schocks versuchen
Sie in keinem Fall, dieses Gerät selbst öffnen, da beim Entfernen der Abdeckungen die Gefahr eines
elektrischen Schlags und/oder andere Gefahren bestehen.
Schlitze und Öffnungen • Wenn das Gerät Schlitze oder Löcher im Gehäuse aufweist, dienen diese zur
Vermeidung einer Überhitzung der empndlichen Teile im Inneren. Diese Öffnungen dürfen niemals von
anderen Objekten blockiert werden.
Litium-Batterie • Explosionsgefahr, falls die Batterie nicht richtig ersetzt wird. Ersetzen Sie verbrauchte Batterien nur
durch den gleichen oder einen vergleichbaren Batterietyp, der auch vom Hersteller empfohlen wird. Entsorgen
Sie verbrauchte Batterien bitte gemäß den Herstelleranweisungen.
Advertencia
Alimentación eléctrica • Este equipo debe conectarse únicamente a la fuente/tipo de alimentación eléctrica
indicada en el mismo. La alimentación eléctrica de este equipo debe provenir de un sistema de distribución
general con conductor neutro a tierra. La tercera pata (puesta a tierra) es una medida de seguridad, no
puentearia ni eliminaria.
Desconexión de alimentación eléctrica • Para desconectar con seguridad la acometida de alimentación eléctrica
al equipo, desenchufar todos los cables de alimentación en el panel trasero del equipo, o desenchufar el
módulo de alimentación (si fuera independiente), o desenchufar el cable del receptáculo de la pared.
Protección del cables de alimentación • Los cables de alimentación eléctrica se deben instalar en lugares donde
no sean pisados ni apretados por objetos que se puedan apoyar sobre ellos.
Reparaciones/mantenimiento • Solicitar siempre los servicios técnicos de personal calicado. En el interior no
hay partes a las que el usuario deba acceder. Para evitar riesgo de electrocución, no intentar personalmente la
reparación/mantenimiento de este equipo, ya que al abrir o extraer las tapas puede quedar expuesto a voltajes
peligrosos u otros riesgos.
Ranuras y aberturas • Si el equipo posee ranuras o orificios en su caja/alojamiento, es para evitar el
sobrecalientamiento de componentes internos sensibles. Estas aberturas nunca se deben obstruir con otros
objetos.
Batería de litio • Existe riesgo de explosión si esta batería se coloca en la posición incorrecta. Cambiar esta batería
únicamente con el mismo tipo (o su equivalente) recomendado por el fabricante. Desachar las baterías usadas
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15
of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired operation.
The Class A limits are designed to provide reasonable protection against harmful interference when the equipment
is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy
and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which
case the user will be required to correct the interference at his own expense.
NOTE: This unit was tested with shielded cables on the peripheral devices. Shielded cables must be used with the
unit to ensure compliance with FCC emissions limits.
.
Conventions Used in this Guide
In this user guide, the following are used:
CAUTION: A caution indicates a potential hazard to equipment or data.
NOTE: A note draws attention to important information.
TIP: A tip provides a suggestion to make working with the application easier.
WARNING: A warning warns of things or actions that might cause injury, death, or
This manual details the installation and operation of the Extron MTP 1500RL 15HD A SEQ
Twisted Pair receiver with audio and skew equalization
In this guide the following terms are used:
z“Transmitter” refers specifically to the MTP transmitter.z“Receiver” or “SEQ receiver” refers specically to the MTP 1500RL 15HD A SEQ receiver
with skew equalization.
MTP 1500RL 15HD A SEQ Description
The receiver is used for long distance distribution of RGB, component (bi-/tri-level), S-video,
or composite video and audio over twisted pair cables.
It is a half rack size twisted pair receiver that is fully compatible with all MTP transmitters,
distribution ampliers, matrix switchers and associated video accessories. When used with
any of the Extron MTP transmitter models, the receiver can transmit video over extended or
standard distances.
The MTP 1500RL 15HD A SEQ receive signals up to 2048x1080, HD component video (up
to1080p), standard component, S-video, bi-level or tri-level component video, and high
resolution RGB video). This is done using an RJ-45 connection and over an Extron Enhanced
Skew-Free™ AV UTP cable, or over a Category (CAT) 5, 5e or CAT 6, shielded twisted pair
The receiver outputs multiple RGB formats, composite video, S-video and component video
on the 15-pin HD connector, according to the current DIP switch settings.
NOTE: The MTP 1500RL receiver cannot be used with VTT or TP transmitters.
The receiver ships with external desktop 12 V, 1 A power supply that accepts 100 to
240 VAC, 50 Hz to 60 Hz input.
zReceives high resolution video and mono audio signals 1,500 feet (450 meters) or more
over a single CAT 5-type cable
zSupports RGBHV, RGBS, RGsB, RsGsBs, component, S-video, and composite videozCompatible with HDTV component video, bi-level or tri-level synczSeparate continuously variable level and peaking controlszBuffered MTP loop-through for daisy-chaining up to eight receiverszIndependent skew compensation adjustments for each colorzCompatible with any Extron MTP transmitterzLow profile, rack-mountable metal enclosure
MTP 1500RL 15HD A SEQ • Introduction1
Transmission Distance
The maximum transmission distance is determined by the frequency and resolution of the
transmitted signal. The table below shows the maximum transmission distances (in feet and
meters) and the transmitter Pre-peak switch positions using Extron Enhanced Skew-Free AV
UTP cable or UTP CAT cable, terminated with RJ-45 connectors.
NOTE: The maximum distance is defined as the distance from the first input signal
Transmission distance with more than one device before the MTP 1500RL 15HD A SEQ
Input
Source
source to the last output signal display, regardless of the number and type of
devices between.
Transmission distance with one device before the MTP 1500RL 15HD A SEQ
1500 feet (457 m) maximum
Input
Source
VGA
cable
VGA
cable
MTP Tx
Device
MTP Tx
Device
TP
cable
1500 feet (457 m) maximum
TP
MTP RL Rx
cable
Device
MTP 1500RL
15HD A Device
TP
cable
15HD A Device
MTP 1500RL
VGA
cable
VGA
cable
Display
Display
Figure 1. Maximum Transmission Distances
NOTE: The transmitter and receiver are designed for and perform best with Extron
Enhanced Skew-Free AV cable terminated in accordance with the TIA/EIA T568A
standard. CAT 5 cables are acceptable but less preferable. Using pre-terminated
and tested cables is also recommended. Cables terminated on-site should be
tested before use to ensure that they comply with Category 5 specifications.
MTP 1500RL 15HD A SEQ • Introduction2
MTP 1500RL 15HD A SEQ Application Diagram
Ext
MTP
Tw
with Loop
RGBHV
PC
Audio
Extron
MTP T 15HD A
Twisted Pair
MTP T 1 5HD A
PRE-PEAK
ON
Transmitter
OUTPUT
AUDIO
OFF
MONITOR
POWER
12V
INPUT
.5A MAX
500’ (152 m) UTP Cable
(CAT 5/5e/6)
Flat Panel
Display
SPARE
END
VIDEO
SOG
CSYNC
V +
H +
ON
AUDIO
MTP 1500RL 15HD A SEQ
MONO
LR
OUTPUT
BUFFERED OUTPUT
INPUT
MTP
MTP
POWER
1500RL 15HD A SEQ
ron
12V
1.0A MAX
isted Pair Receiver
-Through and Skew EQ
Audio
RGBHV
500’ (152 m) UTP Cable
(CAT 5/5e/6)
Extron
MTP 1500RL 15HD A SEQ
Twisted Pair Receiver
with Loop-Through and Skew EQ
Figure 2. Typical MTP 1500RL 15HD A SEQ Application
Flat Panel
Display
SPARE
END
VIDEO
SOG
CSYNC
V +
H +
ON
AUDIO
MTP 1500RL 15HD A SEQ
MONO
LR
OUTPUT
BUFFERED OUTPUT
INPUT
MTP
MTP
POWER
12V
1.0A MAX
Audio
RGBHV
MTP 1500RL 15HD A SEQ • Introduction3
Installation and
Setup
This section describes how to connect applicable cables to the MTP 1500RL A SEQ receiver.
Rear panel connectors and features for the MTP 1500RL A SEQ receiver is shown below.
INPUT
MTP
BUFFERED OUTPUT
MTP
POWER
12V
1A MAX
OUTPUT
AUDIO
MONO
LR
H +
V +
CSYNC
SOG
VIDEO
END
ON
MTP 1500RL 15HD A SEQ
SPARE
1
2
3
4
5
6
Figure 3. Rear Panel Features of the MTP 1500RL 15HD A SEQ
a Power connector — Plug the included external 12 VDC, 1 A, power supply into this
2-pole captive screw connector (see “Power Supply Wiring” section for wiring details).
CAUTIONS:• Always use a power supply supplied or specied by Extron. Use of an
unauthorized power supply voids all regulatory compliance certification
and may cause damage to the supply and the end product.
• Unless otherwise stated, the AC/DC adapters are not suitable for use in
air handling spaces or in wall cavities.
• The installation must always be in accordance with the applicable
provisions of National Electrical Code ANSI/NFPA 70, article 75 and the
Canadian Electrical Code part 1, section 16.
• The power supply must not be permanently fixed to building structure
or similar structure.
b Input connector — Connect one end of the twisted pair cable from an MTP transmitter
to this RJ-45 connector (see “TP Cable Termination” to wire the connector).
CAUTION: Do not connect these devices to a computer data or telecommunications
network.
c Buffered output connector — Connect up to 5 daisy-chained MTP receivers to
this RJ-45 connector.
NOTE: In a daisy-chain, the maximum distance from video source to display device
should not exceed 1500 feet.
MTP 1500RL 15HD A SEQ • Installation and Setup4
d High resolution video output connector — Connect a projector or other high
resolution video device to this 15-pin HD connector for RGB output.
NOTE: See DIP switch settings for signal format output.
e Audio connector — Connect a suitable audio device to the 5-pole captive screw
connector for mono audio output.
MONO AUDIO
1
2
Do not tin the wires!
MONO AUDIO
Mono output 1
NO GROUND.
Sleeve(s)
Mono output 2
NO GROUND.
Unbalanced Output
CAUTION
For unbalanced audio, connect the sleeve(s) to the ground contact.
DO NOT connect the sleeve(s) to the negative (-) contacts.
Mono output 1+
1
Mono output 2+
2
Mono output 1-
Sleeve(s)
Mono output 2-
Balanced Output
Figure 4. Audio Connector Wiring
f Receiver DIP switches — Set these DIP switches for the applicable signal.
zH sync (H+) and V sync (V+) switches — Set these switches up for positive
sync or down for negative sync.
zComposite sync (CSync), Sync on green (SOG), and Video switches —
Set these switches as shown in the table below to output the indicated format.
Output FormatC SyncSOGVideo
RGBHV
RGBS
RGsB
Component video*
S-video
Composite video*
* Input video format must match.
= switch is down
<
= switch is up
>
<<<
><<
<><
<<>
<<>
<<>
H +
V +
CSYNC
SOG
VIDEO
END
SPARE
ON
zEnd unit switch — Set this switch up if either of the following is true:
zThe receiver being configured is the only receiver connected to the transmitter.zThe receiver being configured is the last receiver in a daisy-chained system.
MTP 1500RL 15HD A SEQ • Installation and Setup5
Power Supply Wiring
1.0 A MAX
POWER
AA
NOTE: This product is intended to be supplied by a UL Listed power supply and
Wire the supplied male power connector (plug) as in shown below.
12V
output rated at 12 VDC, 1 A.
Rear Panel
Power Receptacle
DC Power Cord
Captive Screw Connector
Smooth
3/16”
(5 mm) Max.
Ridges
SECTION A–A
2-Pole Captive Screw
Connector
Ground
+12 VDC
AC Power Cord
External
Power Supply
(12 VDC, 1 A )
Power Supply
Output Cord
Tie Wrap
Figure 5. Power Connector Wiring
NOTES: • The length of the exposed wires in the stripping process is critical.
The ideal length is 3/16 inches (5 mm). If it is longer, the exposed wires
may touch one another, causing a short circuit between them. Any shorter
and the wires could be easily pulled out even if tightly fastened by the
captive screws.
• Do not tin the wires. Tinned wire does not hold its shape and can become
loose over time.
CAUTION: Power supply voltage polarity is critical. Incorrect voltage polarity can
damage the power supply and the product. Identify the power cord
negative lead by the ridges on the side of the cord.
To verify the polarity before connection, plug in the power supply with no load and
check the output with a voltmeter.
WARNING: The two power cord wires must be kept separate while the power
As an alternative, an Extron PS 124 Universal 12 VDC Power Supply, part #60-1022-01,
can power multiple MTPs or other Extron 12 VDC devices using only one AC power
connector..
supply is plugged in. Remove power before wiring.
MTP 1500RL 15HD A SEQ • Installation and Setup6
TP Cable Termination
RJ-45 Connector
NOTE: RJ-45 termination must comply with TIA/EIA T568A or TIA/EIA T568B wiring
standards for all connections.
The gure below details the recommended termination of TP cables with RJ-45 connectors
in accordance with the TIA/EIA T568A or TIA/EIA T568B wiring standards. Either standard
can be used with CAT 5 cable, but the same standard must be used on both ends of the
cable.
PinT568A Wire ColorT568B Wire Color
Pins:
1
2
3
4
5
6
7
8
White-greenWhite-orange
GreenOrange
White-orangeWhite-green
BlueBlue
White-blueWhite-blue
OrangeGreen
White-brownWhite-brown
BrownBrown
12345678
Insert Twisted
Pair Wires
Figure 6. TP Cable Termination
NOTES: • Enhanced Skew-free AV cable is not recommended for Ethernet/LAN
applications.
•DO NOT connect the RJ-45 input to LAN, Ethernet, outside plant
communications, or any telecommunications networks
• This cable is specially designed for compatibility with Extron Twisted Pair
products that are wired using the TIA/EIA T568A standard.
The table below shows the MTP RJ-45 pin assignments for audio and video signals.
8Blue/H Sync -Blue/C Sync -No SignalNo SignalB- Y -
Figure 7. MTP RJ-45 Pin Assignments
MTP 1500RL 15HD A SEQ • Installation and Setup7
Operation
This section describes the operation details for the MTP 1500RL RS SEQ receiver. It covers:
zFront Panel Controls and IndicatorszPeaking and Level AdjustmentzSkew Delay Compensation
Front Panel Controls and Indicators
Front panel features on the MTP 1500RL 15HD A SEQ receiver are shown below.
1
2
3
4
5
6
SELECT
RED
GREEN
BLUE
DELAY
ADJUST
LEVEL
PEAKING
RGB
MIN/MAX
MTP 1500RL SERIES
Figure 8. MTP 1500RL 15HD A SEQ Receiver Front Panel
a Power LED — Indicates power is applied to the MTP.
b Select button — This recessed button selects the red, green, or blue video signal to
adjust, and resets all them to a skew delay of zero nanoseconds.
Press and release this button to cycle through and select the red, green, or blue video
signal for adjusting. The selected signal is indicated by the Red, Green, and Blue LEDs
(c).
Press and hold the button in for approximately 3 seconds to zero the skew delay for red,
green, and blue. The Red, Green, and Blue LEDs (d) all turn off. Release the button.
NOTE: The SEQ receiver automatically saves the setting for the video signal that is
being deselected when this button is pushed or when the selection times
out after 10 seconds.
c Red, Green, and Blue LEDs — These LEDs indicate the video signal that is selected by
the Select button (b) for skew adjustment using the Adjust control (d). The LED for the
selected color blinks when the skew compensation for the video signal of the selected
color has reached the minimum or maximum limit.
MTP 1500RL 15HD A SEQ • Operation8
d Adjust skew control — This control delays the selected red, green, or blue video signal
up to a maximum of 62 nanoseconds (ns), made in 2 ns incremental steps. Rotate the
control counterclockwise to reduce the delay or clockwise to increase it (see “Skew
Delay Compensation” for details).
NOTES:• The movement of the adjustment control is smooth and does not have
mechanical steps or high- and low-limit stops.
• Watch the displayed image to observe the steps of delay.
• For best performance set the skew of the most delayed signal to 0 ns
(minimum) and adjust the other two signals to meet it.
e Level control — The Level control alters the video output voltage to affect the
brightness of the displayed image.
Adjust the knob while viewing the displayed image to set the level or boost that
provides the best picture quality (see “Peaking and Level Adjustment” section for
details).
f Peaking control — Peaking affects the sharpness of a picture. Increased peaking can
compensate for mid- and high-frequency detail loss due to low bandwidth system
components or capacitance in long cables.
Adjust this control while viewing the displayed image to obtain the optimum picture
sharpness. The LED lights red when the peaking is at the minimum (0) and maximum
(100%) peaking settings (see the “Peaking and Level Adjustment” section for
details).
NOTE: To avoid possible video loss due to errors in the format detection, always
Peaking and Level Adjustment
For best performance and video format detection, the equalization of the MTP should be
adjusted properly. To achieve this, do the following:
1. Terminate the green video signal output with a 75 ohm resistance, and measure the
video signal.
NOTE:• Set the gain adjustment so that a white field video signal is +0.7
2. Using an alternating black and white pattern, adjust the peaking so that the video signal
matches that of the white field video. This equalizes both the low frequency (white field)
and the high frequency (alternating black and white field) to the same video level for
best results.
Do not over-peak the signal.
start with minimal peaking and level, then increase values only as required.
volts from the ground level.
• Set the peaking adjustment using the highest frequency video
format signal for the system in RGB, component video, or S-video.
MTP 1500RL 15HD A SEQ • Operation9
Skew Delay Compensation
CAT 5, 5e and CAT 6 cable can lead to registration errors between the red, green, and
blue video signals. Pair skew can be measured with test equipment or identified by viewing
a crosshatch test pattern to determine if either the red, green, or blue video image leads
(appears to the left of) the other two video images.
NOTE: Unless the TP cable is changed, the skew adjustment should need to be
made only once, during installation
SEQ receiver skew compensation
The SEQ receivers have built-in skew compensation capabilities. Adjust the equalization as
follows:
1. Set the skew delay to zero for red, green, and blue as follows:
a. Use a Tweeker or other small screwdriver to press and hold the Select button for
3 seconds. The Red, Green, and Blue LEDS all go out.
b. Release the Select button.
2. Use UTP cable test equipment or examine the displayed video image with a critical eye
to determine which video signal (red, green, or blue) is shifted furthest to the right.
NOTE: A crosshatch test pattern or a black background with vertical white lines is
ideal for determining skew.
3. Adjust the furthest left video signal as follows:
NOTE: The SEQ receiver cannot shift the furthest right video image to the left.
a. Use a Tweeker or other small screwdriver to press and release the Select button until
the LED for the left-shifted color (red, green, or blue) lights.
b. Slowly rotate the Adjust control clockwise while monitoring the display. Continue to
rotate the control until that color is properly converged.
NOTE: A 2ns adjustment is very ne. Up to 10ns of delay may be necessary before
a change in the display is detectable. The maximum delay possible is 62ns.
c. Use a Tweeker or other small screwdriver to press the Select button one more time
to save the most recent adjustment or allow the 10-second timeout to elapse.
4. If the remaining color is left shifted, repeat step 3.
MTP 1500RL 15HD A SEQ • Operation10
Reference
Information
This section provides information about:
zSpecificationszPart Numbers and Accessories
Specications
Video
Gain ............................................... Unity
Number/signal type ........................ 1 set of proprietary analog signals
Warranty ........................................ 3 years parts and labor
NOTE: All nominal levels are at ±10%.
NOTE: Specifications are subject to change without notice.
MTP 1500RL 15HD A SEQ • Reference Information12
Part Numbers and Accessories
Included Parts
DescriptionPart Number
MTP 1500RL 15HD A SEQ receiver60-959-02
External, 12 VDC, 1A power supply PS 1210 C70-775-01
3.5 mm, 3-pole captive screw connector for RS 232 connections
IEC power cord (1)
MTP 1500RL 15HD A SEQ Setup Guide
Optional Parts
These items can be ordered separately:
DescriptionPart Number
Accessories
PS 124 multiple output 12 V power supply60-1022-01
19" 1U Universal Rack Shelf60-190-01
19" 1U Basic Rack Shelf60-604-01
Enhanced Skew-Free™ AV cable
NOTE: Enhanced Skew-Free AV UTP cables are not recommended for Ethernet LAN applications.
Enhanced Skew-Free AV cable (cut, various lengths)26-569-xx
Enhanced Skew-Free AV 1000' (Bulk) (non-plenum)22-141-03
Plenum enhanced Skew-Free AV 1000' (Bulk)22-142-03
RJ-45 connectors
CAT 6 jack (black)10-463-10
CAT 6 jack (red)10-463-11
CAT 6 jack (blue)10-463-12
CAT 6 jack (orange)10-463-13
CAT 6 jack (gray)10-463-14
CAT 6 jack (white)10-463-15
CAT 6 jack (ivory)10-463-16
MTP 1500RL 15HD A SEQ • Reference Information13
Mounting
This section outlines the various mounting options available for the MTP 1500RL unit:
Attach the four provided rubber feet to the bottom of the unit and place it in any
convenient location.
Rack Mounting
UL Guidelines for Rack Mounting
The following Underwriters Laboratories (UL) guidelines are relevant to the safe installation
of these products in a rack:
1. Elevated operating ambient temperature — If the unit is installed in a closed or
multi-unit rack assembly, the operating ambient temperature of the rack environment
may be greater than room ambient temperature. Therefore, install the equipment in an
environment compatible with the maximum ambient temperature (Tma: +122 °F,
+50 °C) specified by Extron.
2. Reduced air flow — Install the equipment in the rack so that the equipment gets
adequate air flow for safe operation.
3. Mechanical loading — Mount the equipment in the rack so that uneven mechanical
loading does not create a hazardous condition.
4. Circuit overloading — Connect the equipment to the supply circuit and consider the
effect that circuit overloading might have on overcurrent protection and supply wiring.
Appropriate consideration of the equipment nameplate ratings should be used when
addressing this concern.
5. Reliable earthing (grounding) — Maintain reliable grounding of rack-mounted
equipment. Pay particular attention to supply connections other than direct connections
to the branch circuit (such as the use of power strips).
MTP 1500RL 15HD A SEQ • Mounting14
Rack Mounting Procedure
ws longer
The unit can be mounted on optional rack systems, including:
zRSU 129: 9.5 inch deep, 1U rack shelf kit (part number 60-190-01)zRSU 126: 6 inch deep, 1U rack shelf kit (part number 60-190-10)
To mount the device on a rack shelf
1. Remove the feet from the bottom of the MTP, if they are installed.
2. Mount the MTP using two 4-40 x 3/16 inch screws in opposite (diagonal) corners to
secure the MTP to the shelf.
NOTE:DO NOT stack units on top of one another as this may cause the units to
overheat.
3. Install false faceplates or other units to the rack shelf.
1U Universal Rack Shelf
Front false
faceplate
uses 2
screws.
1/2 Rack Width Front False
Faceplate
Figure 9. Mounting the MTP on a Standard Shelf
Under-desk Mounting
Mount the unit under a desk or podium, using the optional Extron MBU 125 under-desk
mounting kit (part number 70-077-01) by following the instructions provided with the kit.
Through-desk Mounting
Mount the unit through a desk or podium using the optional Extron MBD 129 through desk
mounting kit (part number 70-077-02) by following the instructions provided with the kit.
Use 2 mounting holes on
opposite corners.
(2) 4-40 x 3/16"
Screws
NOTE: Using scre
than 3/16” will damage the
unit and void the warranty.
MTP 1500RL 15HD A SEQ • Mounting15
Extron Warranty
Extron Electronics warrants this product against defects in materials and workmanship for a period of three years
from the date of purchase. In the event of malfunction during the warranty period attributable directly to faulty
workmanship and/or materials, Extron Electronics will, at its option, repair or replace said products or components,
to whatever extent it shall deem necessary to restore said product to proper operating condition, provided that it is
returned within the warranty period, with proof of purchase and description of malfunction to:
USA, Canada, South America,
and Central America:
Extron Electronics
1001 East Ball Road
Anaheim, CA 92805
U.S.A.
Europe, Africa, and the Middle
East:
Extron Europe
Hanzeboulevard 10
3825 PH Amersfoort
The Netherlands
Asia:
Extron Asia
135 Joo Seng Road, #04-01
PM Industrial Bldg.
Singapore 368363
Japan:
Extron Electronics, Japan
Kyodo Building, 16 Ichibancho
Chiyoda-ku, Tokyo 102-0082
Japan
China:
Extron China
686 Ronghua Road
Songjiang District
Shanghai 201611
China
Middle East:
Extron Middle East
Dubai Airport Free Zone
F12, PO Box 293666
United Arab Emirates, Dubai
Singapore
This Limited Warranty does not apply if the fault has been caused by misuse, improper handling care, electrical or
mechanical abuse, abnormal operating conditions, or if modifications were made to the product that were not
authorized by Extron.
NOTE: If a product is defective, please call Extron and ask for an Application Engineer to receive an RA (Return
Authorization) number. This will begin the repair process.
Units must be returned insured, with shipping charges prepaid. If not insured, you assume the risk of loss or damage
during shipment. Returned units must include the serial number and a description of the problem, as well as the
name of the person to contact in case there are any questions.
Extron Electronics makes no further warranties either expressed or implied with respect to the product and its quality,
performance, merchantability, or fitness for any particular use. In no event will Extron Electronics be liable for direct,
indirect, or consequential damages resulting from any defect in this product even if Extron Electronics has been
advised of such damage.
Please note that laws vary from state to state and country to country, and that some provisions of this warranty may