This guide provides basic instructions for an experienced installer to set up and operate the Extron® MMX 32 VGA MTP mini matrix switcher.
N
For full installation and operating details, refer to the MMX 32 VGA MTP Users’s Guide,
available online at www.extron.com.
Step 1 — Mounting
Turn off or disconnect all equipment power sources and mount the MMX 32 VGA MTP as required (rack, furniture, or tabletop mounted).
Step 2 — Connect inputs
Connect up to three video sources (RGBHV, RGBS, RGsB, RsGsBs, component video, S-video or composite video) to the female 15-HD connectors, inputs 1-3. Connect audio sources to the 3.5 mm stereo jacks and wire the audio connectors as shown at right.
Step 3 — Connect outputs
Attach the applicable output cables (video, audio, and video and audio) as below:
a. Video output 1 — Connect a display device to this female 15-pin HD connector.
b. Audio output 1 — Connect speakers to this 3.5 mm stereo jack.
c. Audio/Video (RGB) output 2 — Connect an MTP U R series or other MTP receiver
to this RJ-45 UTP connector. Wire the connector as shown at right. Connect a projector or other RGB video output device to the receiver, and connect speakers for summed (L and R) mono audio output.
d. Audio output 2 — Connect speakers
to this 5-pole, 3.5 mm captive screw connector for balanced/unbalanced audio and wire connector for dual mono output as shown below.
L
MONO AUDIO
R
L
MONO AUDIO
R
Unbalanced Output
Balanced Output
Do not tin the wires!
Mono output 1-
Sleeve(s)
Mono output 1+
Mono output 2+
Mono output 2-
Sleeve(s)
Mono output 1
Mono output 2
NO GROUND.
NO GROUND.
C
For unbalanced audio, connect both sleeves to the center (ground)
contact. DO NOT connect the sleeves to the negative (-) contacts.
Setup Guide — MMX 32 VGA MTP
NOTE If you are using Enhanced Skew-Free™ A/V
cable, use the TIA/EIA T568A standard only.
Insert Twisted Pair Wires
Pins:
12 34 56 78
RJ-45 Connector
5
Pin
1 Red+/V. sync+
2 Red–/V. sync–
3 Mono audio+
Green–
6 Mono audio–
7 Blue+/H. sync+
8
Blue–/H. sync–
4
Wire color
White-green
Green
White-orange
White-blue
Orange
White-brown
Brown
Wire color
568 A 568 B
Signal
White-orange
Orange
White-green
White-blue
Green
White-brown
Brown
Green+Blue Blue
L R
INPUT 2
INPUT 1
AUDIO
AUDIO
OUTPUT 1
AUDIO
INPUT 3
AUDIO
REMOTE
AUDIO
MMX 32 VGA MTP
OUTPUT 1
2 1 3
OUTPUT 2
2 1 3
RS-232
+5V
POWER 12V
0.5A MAX
2
1
1 2 3
CONTACT
Tx Rx
SYNC - TRI
PRE PEAK - ON
OUTPUT 2
RGB/AUDIO
Sleeve ( )
Ring (R)
Tip (L)
3.5 mm TRS Stereo Plug Connector
(unbalanced)
1
Page 2
Step 4 — Remote connections
a. Contact closure connectors — Connect an Extron
MMX 32 AAP or MMX 32 MAAP contact closure remote control panel to these two 5-pole captive screw connectors to provide control for outputs 1 and 2. Connect the 5 V and Gnd (-) 2-pole captive screw connector on the AAP or MAAP to either of these connectors.
b. RS-232 connector — Connect an RS-232 control module to this 3-pole captive screw
connector (see image above) to allow remote control using the Extron Simple Instruction Set™(SIS™) or the Extron Universal Switcher Control Program.
N
For full SIS commands and details of the Universal Switcher Control Program, refer to the
MMX 32 VGA MTP Users’s Guide.
Step 5 — Power
Plug the included external 12 VDC power supply into the 2-pole captive screw connector. Wire the connector as shown at right.
Step 6 — Pre-Peaking and sync selection
Pre-Peaking — To compensate for signal loss over long cable runs, set the DIP switch position (up = on, down = off) as shown in the table below:
Video Format
Cable length
Signal quality at max.
distance
Pre-Peak Off Pre-Peak On High Variable
Composite, S-video, Component
800 ft (245 m) 1000 ft (300 m)
640 x 480 <300 ft (90 m) >350 ft (105 m) 700 ft (215 m) 750 ft (230 m)
800 x 600 <300 ft (90 m) >350 ft (105 m) 550 ft (165 m) 650 ft (200 m)
1024 x 760 <300 ft (90 m) >350 ft (105 m) 500 ft (150 m) 600 ft (185 m)
1280 x 1024 <250 ft (75 m) >300 ft (90 m) 350 ft (105 m) 450 ft (135 m)
1600 x 1200 <250 ft (75 m) >300 ft (90 m) 300 ft (90 m) 450 ft (135 m)
Sync selection — To select either bi-level sync or tri-level sync on output 2, set the sync DIP
switch to the desired setting (up = tri-level sync, down = bi-level sync).
N
Set when transmitting tri-level sync component video.
SECTION A–A
A A
Power Supply
Output Cord
Ridges
Smooth
3/16"
(5 mm) Max.
2-Pole Captive Screw Connector
Tie Wrap
Setup Guide — MMX 32 VGA MTP cont’d
REMOTE
RS-232
+5V
2
1
1 2 3
Tx Rx
CONTACT
Output 1 control
Output 2 control
RS-232
connection
SYNC - TRI
PRE PEAK - ON
2
Page 3
Front Panel Operation
Outputs 1 and 2 — For each output press the button for the desired input (1, 2 or 3). The
LED for that input lights.
N
When power is applied, the LEDs light sequentially from left to right. For first time power
up, the unit’s default configuration is input 1 tied to both outputs 1 and 2, the front panel is not locked, and all states are unmuted. Input 1 LEDs for output 1 and for output 2 are both lit. If this is not a first time power up, then the LEDs for the last valid input selections light.
Front panel security lock out (executive mode)
Locking the front panel protects the switcher from unwanted tampering. While the switcher is locked, the user can select inputs only through a remote device.
To lock or unlock the front panel, press the following buttons simultaneously and hold them for at least 3 seconds:
• For output 1 press and hold input 1 button. • For output 2 press and hold input 3 button.
The front panel LEDs flash to indicate that the front panel is locked.
System reset
To reset the switcher to its factory settings, press and hold output 1’s input 3 button while powering up the switcher.
Audio switching
When you selecting an input, the audio and video signals from that input are routed together to the appropriate output.
Audio breakaway is possible through the Extron Simple Instruction Set (SIS) or the Extron Universal Switcher Control Program. When audio breakaway is active, the front panel input LED for the audio source flashes, while the LED of the video source lights steadily.
Device Control
Output control
Momentarily short the rear panel Remote contact pin 1, 2, or 3 for the desired output to ground to switch to that input. Use the +5 V port when controlling the output with an MMX 32 AAP/MAAP panel.
RS-232 Control
Software control via the RS-232 connection is possible using the Extron Simple Instruction Set (SIS) or the Extron Windows®-based control program. The RS-232 connector on the MMX 32 VGA MTP is a 3-pole captive screw connector.
The protocol for this connector is:
• 9600 baud • 8-bit • 1 stop bit • no parity • no flow control
N
For RS-232 connect transmit, receive, and ground connectors to the control system or PC.
Software control
Installation — Insert the supplied Extron DVD into DVD drive on a PC that is connected to the MMX. The installation window opens automatically. Select the Software tab, scroll to the Universal Switcher control program, and click on Install. Follow the on-screen instructions to complete installation.
Startup and use — To start up the installed software, click on the desktop icon. To use the software, refer to the MMX 32 VGA MTP Users’s Guide, available online at
www.extron.com, for details.
3
OUTPUT 1
2 1 3
OUTPUT 2
2 1 3
Press and hold Input 1 Button for Output 1.
Press and hold Input 3 Button for Output 2.
Page 4
Setup Guide — MMX 32 VGA MTP cont’d
Extron USA - West
Headqu arte rs
+800 .633.987 6
Inside USA / Canada Only
+1.714.491.1500 +1.714.491.1517 FAX
Extron USA - East
+800 .633.987 6
Inside USA / Canada Only
+1.919.863.179 4 +1.919.863.179 7 FAX
Extron Europe
+800 .3987.6673
Inside Europe Only
+31.33. 453.404 0 +31.33. 453.405 0 FAX
Extron Asia
+800 .7339.876 6
Inside Asia Only
+65.6 383.44 00 +65.6 383.46 64 FAX
Extron Japan
+81.3.3 511.7655 +81.3.3 511.7656 F AX
Extron China
+400 .883.1568
Inside China Only
+86.2 1.3760.1568 +86.2 1.3760.1566 FA X
Extron Middle East
+971.4. 2991800 +971.4. 2991880 FA X
68-789-50
Rev. A
03 10
Command ASCII
command (host to switcher)
Response (switcher to host)
Additional description
Create ties
Tie input X@ to output X#, A and V
X@*X#
! OutX# InX@ All] Tie input X@ audio and video to
output X#.
Tie input X@ RGB to output X#
X@*X#
% OutX# InX@ RGB] Tie input X@ RGB to output X#.
Tie input X@ audio to output X#
X@*X#
$ OutX# InX@ Aud] Tie input X@ audio to output X#.
RGB mute
RGB mute X#*1B VmtX#*1
]
Mute RGB output X#.
RGB unmute X#*0B VmtX#*0
]
Unmute RGB output X#.
Read RGB mute X#B
X(
]
Show RGB mute status X(.
Global (where X# is not included, global RGB mute is activated.)
RGB mute all 1*B Vmt1
]
Mute all RGB.
RGB unmute all 0*B Vmt0
]
Unmute all RGB.
Audio mute
Audio mute X#*1Z AmtX#*1] Mute audio output X#
.
Audio unmute X#*0Z AmtX#*0] Unmute audio output X#.
Read audio mute X#Z
X(]
Show audio mute status X(
.
Global (where X# is not included, global audio mute is activated.)
Audio mute all 1*Z Amt1
]
Mute all audio.
Audio unmute all 0*Z Amt0
]
Unmute all audio.
View ties and output mute
View RGB output tie
X#%
X@
]
Output X# is tied to input X@ video.
View audio output tie
X#$
X@
]
Output X# is tied to input X@ audio.
Output mute X#VM
X2)
]
Output X# mute status is X2)
X@ = Input number (for tie) 0 – 3, 0 = disconnected X# = Output number 1 or 2 X( = 0 or 1 0 = off, 1 = on X2) = Mute 0 = no mute, 1 = video mute, 2 = audio mute,
3 = video and audio mute
N
4
© 2010 Extron Electronics. All rights reserved.
Control by SIS commands
The switcher can be controlled through the use of Extron SIS commands via the RS-232 connector. For full details on SIS commands refer to the MMX 32 VGA MTP Users’s Guide.