This symbol is intended to alert the user of important operating and maintenance
(servicing) instructions in the literature provided with the equipment.
This symbol is intended to alert the user of the presence of uninsulated dangerous
voltage within the product's enclosure that may present a risk of electric shock.
Caution
ReadInstructions • Read and understand all safety and operating instructions before using the
equipment.
Retain Instructions • The safety instructions should be kept for future reference.
Follow Warnings • Follow all warnings and instructions marked on the equipment or in the user
information.
Avoid Attachments • Do not use tools or attachments that are not recommended by the equipment
manufacturer because they may be hazardous.
Consignes de Sécurité • Français
Ce symbole sert à avertir l’utilisateur que la documentation fournie avec le matériel
contient des instructions importantes concernant l’exploitation et la maintenance
(réparation).
Ce symbole sert à avertir l’utilisateur de la présence dans le boîtier de l’appareil de
tensions dangereuses non isolées posant des risques d’électrocution.
Attention
Lire les instructions• Prendre connaissance de toutes les consignes de sécurité et d’exploitation avant
d’utiliser le matériel.
Conserver les instructions• Ranger les consignes de sécurité afin de pouvoir les consulter à l’avenir.
Respecter les avertissements • Observer tous les avertissements et consignes marqués sur le matériel ou
présentés dans la documentation utilisateur.
Eviter les pièces de fixation • Ne pas utiliser de pièces de fixation ni d’outils non recommandés par le
fabricant du matériel car cela risquerait de poser certains dangers.
Sicherheitsanleitungen • Deutsch
Dieses Symbol soll dem Benutzer in der im Lieferumfang enthaltenen
Dokumentation besonders wichtige Hinweise zur Bedienung und Wartung
(Instandhaltung) geben.
Dieses Symbol soll den Benutzer darauf aufmerksam machen, daß im Inneren des
Gehäuses dieses Produktes gefährliche Spannungen, die nicht isoliert sind und
die einen elektrischen Schock verursachen können, herrschen.
Achtung
Lesen der Anleitungen • Bevor Sie das Gerät zum ersten Mal verwenden, sollten Sie alle Sicherheits-und
Bedienungsanleitungen genau durchlesen und verstehen.
Aufbewahren der Anleitungen • Die Hinweise zur elektrischen Sicherheit des Produktes sollten Sie
aufbewahren, damit Sie im Bedarfsfall darauf zurückgreifen können.
Befolgen der Warnhinweise • Befolgen Sie alle Warnhinweise und Anleitungen auf dem Gerät oder in
der Benutzerdokumentation.
Keine Zusatzgeräte • Verwenden Sie keine Werkzeuge oder Zusatzgeräte, die nicht ausdrücklich vom
Hersteller empfohlen wurden, da diese eine Gefahrenquelle darstellen können.
Warning
Power sources • This equipment should be operated only from the power source indicated on the
product. This equipment is intended to be used with a main power system with a grounded
(neutral) conductor. The third (grounding) pin is a safety feature, do not attempt to bypass or
disable it.
Power disconnection • To remove power from the equipment safely, remove all power cords from
the rear of the equipment, or the desktop power module (if detachable), or from the power
source receptacle (wall plug).
Power cord protection • Power cords should be routed so that they are not likely to be stepped on or
pinched by items placed upon or against them.
Servicing • Refer all servicing to qualified service personnel. There are no user-serviceable parts
inside. To prevent the risk of shock, do not attempt to service this equipment yourself because
opening or removing covers may expose you to dangerous voltage or other hazards.
Slots and openings • If the equipment has slots or holes in the enclosure, these are provided to
prevent overheating of sensitive components inside. These openings must never be blocked by
other objects.
Lithium battery • There is a danger of explosion if battery is incorrectly replaced. Replace it only
with the same or equivalent type recommended by the manufacturer. Dispose of used batteries
according to the manufacturer's instructions.
Avertissement
Alimentations• Ne faire fonctionner ce matériel qu’avec la source d’alimentation indiquée sur
l’appareil. Ce matériel doit être utilisé avec une alimentation principale comportant un fil de
terre (neutre). Le troisième contact (de mise à la terre) constitue un dispositif de sécurité :
n’essayez pas de la contourner ni de la désactiver.
Déconnexion de l’alimentation• Pour mettre le matériel hors tension sans danger, déconnectez tous
les cordons d’alimentation de l’arrière de l’appareil ou du module d’alimentation de bureau (s’il
est amovible) ou encore de la prise secteur.
Protection du cordon d’alimentation • Acheminer les cordons d’alimentation de manière à ce que
personne ne risque de marcher dessus et à ce qu’ils ne soient pas écrasés ou pincés par des
objets.
Réparation-maintenance • Faire exécuter toutes les interventions de réparation-maintenance par un
technicien qualifié. Aucun des éléments internes ne peut être réparé par l’utilisateur. Afin
d’éviter tout danger d’électrocution, l’utilisateur ne doit pas essayer de procéder lui-même à ces
opérations car l’ouverture ou le retrait des couvercles risquent de l’exposer à de hautes tensions
et autres dangers.
Fentes et orifices • Si le boîtier de l’appareil comporte des fentes ou des orifices, ceux-ci servent à
empêcher les composants internes sensibles de surchauffer. Ces ouvertures ne doivent jamais
être bloquées par des objets.
Lithium Batterie • Il a danger d'explosion s'll y a remplacment incorrect de la batterie. Remplacer
uniquement avec une batterie du meme type ou d'un ype equivalent recommande par le
constructeur. Mettre au reut les batteries usagees conformement aux instructions du fabricant.
Vorsicht
Stromquellen • Dieses Gerät sollte nur über die auf dem Produkt angegebene Stromquelle betrieben
werden. Dieses Gerät wurde für eine Verwendung mit einer Hauptstromleitung mit einem
geerdeten (neutralen) Leiter konzipiert. Der dritte Kontakt ist für einen Erdanschluß, und stellt
eine Sicherheitsfunktion dar. Diese sollte nicht umgangen oder außer Betrieb gesetzt werden.
Stromunterbrechung • Um das Gerät auf sichere Weise vom Netz zu trennen, sollten Sie alle
Netzkabel aus der Rückseite des Gerätes, aus der externen Stomversorgung (falls dies möglich
ist) oder aus der Wandsteckdose ziehen.
Schutz des Netzkabels • Netzkabel sollten stets so verlegt werden, daß sie nicht im Weg liegen und
niemand darauf treten kann oder Objekte darauf- oder unmittelbar dagegengestellt werden
können.
Wartung • Alle Wartungsmaßnahmen sollten nur von qualifiziertem Servicepersonal durchgeführt
werden. Die internen Komponenten des Gerätes sind wartungsfrei. Zur Vermeidung eines
elektrischen Schocks versuchen Sie in keinem Fall, dieses Gerät selbst öffnen, da beim Entfernen
der Abdeckungen die Gefahr eines elektrischen Schlags und/oder andere Gefahren bestehen.
Schlitze und Öffnungen • Wenn das Gerät Schlitze oder Löcher im Gehäuse aufweist, dienen diese
zur Vermeidung einer Überhitzung der empfindlichen Teile im Inneren. Diese Öffnungen dürfen
niemals von anderen Objekten blockiert werden.
Litium-Batterie • Explosionsgefahr, falls die Batterie nicht richtig ersetzt wird. Ersetzen Sie
verbrauchte Batterien nur durch den gleichen oder einen vergleichbaren Batterietyp, der auch
vom Hersteller empfohlen wird. Entsorgen Sie verbrauchte Batterien bitte gemäß den
Herstelleranweisungen.
Instrucciones de seguridad • Español
Este símbolo se utiliza para advertir al usuario sobre instrucciones importantes de
operación y mantenimiento (o cambio de partes) que se desean destacar en el
contenido de la documentación suministrada con los equipos.
Este símbolo se utiliza para advertir al usuario sobre la presencia de elementos con
voltaje peligroso sin protección aislante, que puedan encontrarse dentro de la caja
o alojamiento del producto, y que puedan representar riesgo de electrocución.
Precaucion
Leer las instrucciones • Leer y analizar todas las instrucciones de operación y seguridad, antes de usar
el equipo.
Conservar las instrucciones • Conservar las instrucciones de seguridad para futura consulta.
Obedecer las advertencias • Todas las advertencias e instrucciones marcadas en el equipo o en la
documentación del usuario, deben ser obedecidas.
Evitar el uso de accesorios • No usar herramientas o accesorios que no sean especificamente
recomendados por el fabricante, ya que podrian implicar riesgos.
Advertencia
Alimentación eléctrica • Este equipo debe conectarse únicamente a la fuente/tipo de alimentación
eléctrica indicada en el mismo. La alimentación eléctrica de este equipo debe provenir de un
sistema de distribución general con conductor neutro a tierra. La tercera pata (puesta a tierra) es
una medida de seguridad, no puentearia ni eliminaria.
Desconexión de alimentación eléctrica • Para desconectar con seguridad la acometida de
alimentación eléctrica al equipo, desenchufar todos los cables de alimentación en el panel trasero
del equipo, o desenchufar el módulo de alimentación (si fuera independiente), o desenchufar el
cable del receptáculo de la pared.
Protección del cables de alimentación • Los cables de alimentación eléctrica se deben instalar en
lugares donde no sean pisados ni apretados por objetos que se puedan apoyar sobre ellos.
Reparaciones/mantenimiento • Solicitar siempre los servicios técnicos de personal calificado. En el
interior no hay partes a las que el usuario deba acceder. Para evitar riesgo de electrocución, no
intentar personalmente la reparación/mantenimiento de este equipo, ya que al abrir o extraer las
tapas puede quedar expuesto a voltajes peligrosos u otros riesgos.
Ranuras y aberturas • Si el equipo posee ranuras o orificios en su caja/alojamiento, es para evitar el
sobrecalientamiento de componentes internos sensibles. Estas aberturas nunca se deben obstruir
con otros objetos.
Batería de litio • Existe riesgo de explosión si esta batería se coloca en la posición incorrecta. Cambiar
esta batería únicamente con el mismo tipo (o su equivalente) recomendado por el fabricante.
Desachar las baterías usadas siguiendo las instrucciones del fabricante.
All trademarks mentioned in this manual are the properties of their respective owners.
68-598-01 Rev. A
Printed in the USA
10 01
iiMediaLink Switchers • Table of Contents
MediaLink Switchers
Chapter One
1
Introduction
About the MediaLink Switchers
Features
Introduction
About the MediaLink Switchers
The Extron MediaLink™ switchers (MLS 306, MLS 506, MLS 506MA [70V/100V],
and MLS 506SA) are a family of rack-mountable, six-input (three video/S-video,
three RGB/computer video) switchers with audio control. The MLS 506, MLS 506MA,
and MLS 506SA can also accept component video input. Each can be used in standalone applications or can be connected to a MediaLink Controller (MLC 206) to add
control functions for integration into small to mid-sized audio-visual systems.
“MLS”, “MediaLink Switcher”, and “switcher” will be used interchangeably in this
manual to refer to all models of MediaLink switchers.
Features and Options
Standard features
Flexible control options — The MediaLink switchers can be controlled via RS-232
Audio volume control — All MLS models offer audio preamp volume adjustment
Bass and treble control — The bass and treble levels can be set separately for each
Audio amplification (MLS 506MA and MLS 506SA only) — The MLS 506MA and
Customizable input labeling — Customized input selection button labels can be
Executive mode — You can set the switcher to executive mode to prevent changes
Triple-Action Switching
connection to a third party control system or an Extron MediaLink Controller.
They can also be controlled by contact closure devices.
(attenuation) via a front panel rotary knob.
audio input.
MLS 506SA offer amplified outputs and an effects loop that allows you to add
a device such as an equalizer into the system ahead of the amplified audio
output.
created by using a labeling machine such as a Brother P-touch labeler, or you
can use Extron software to create and print labels.
to settings from being made from the front panel controls. When executive
mode is active, only input selection can be performed from the front panel.
™
— When the MLS switches between RGB inputs, the
screen goes black briefly (you set the delay time) while the display locks on to
the new input’s sync signal, then the RGB picture is displayed without glitches.
100-240V 0.2A 50/60 Hz
.5A MAX
MLS 306 MediaLink Switcher
100-240V 0.2A 50/60 Hz
.5A MAX
MLS 506SA MediaLink Switcher
MediaLink Switchers • Introduction1-2
WORK
VCRDVD
TUNER
123456
INPUT 1
INPUT 2INPUT 3INPUT 4INPUT 5INPUT 6
LR LR LRLR LR LR
VCRDVD
TUNER
123456
INPUT 1
INPUT 2
INPUT 3
VIDEO
R-Y
VIDEO
R-Y
VIDEO
R-Y
RH/
Y
Y
Y
G
B-Y
B-Y
C
LR LR LRLR LR LR
B-Y
C
C
B
DOC
MAC
CELL CAMERA
WORK
DOC
MAC
CELL CAMERA
INPUT 4
INPUT 5
RH/
HV
V
RH/
HV
V
G
G
B
B
VIDEO
FIXEDVARIABLE
AUDIO OUT
LRLR
V
MLC/IR
ABC
MIX
VOLUME
STEREO AMPLIFIED OUTPUT
LEFT RIGHT
MLC/IRRS232
FIXEDVARIABLE
ABC
VOLUME
ADJUST
ADJUST
Y/C
MediaLink Switcher
RS232
CONTACT CLOSURE
CLIP
MLS 506SA
MediaLink Switcher
CONTACT CLOSURE
MLS 306
VID
MENU NEXT
R
RGBHV
OUTPUTS
INPUT 6
RH/
HV
V
G
B
SENDLRRETURN
LR
BGH
AUDIO OUT
LRLR
MENU NEXT
YUV
RGB
R-Y
HV
S-VIDEO
Y
Y
V
B-Y
C
AUX/MIXEFFECTS
LR
MediaLink Switchers
Chapter Two
2
Installation
UL/Safety Requirements
Mounting the Switcher
MLS 306 Rear Panel and Cabling
MLS 506, MLS 506MA, and MLS 506SA Rear Panels and Cabling
Setting the -6dB Jumpers
Application Diagrams
Installation
UL/Safety Requirements
The Underwriters Laboratories (UL) requirements listed below pertain to the safe
installation and operation of a MediaLink Switcher.
1.Do not use the switcher near water.
2.Clean the switcher only with a dry cloth.
3.Do not install the switcher near any heat source, such as a radiator, heat
4.Unplug the switcher during lightning storms or when it will be unused for
Mounting the Switcher
Tabletop use
Each MLS switcher comes with rack mounting brackets and rubber feet. For tabletop use, attach a self-adhesive rubber foot to each corner of the bottom of the unit.
Rack mounting
For rack mounting, do not install the rubber feet. If you need to change the settings
of the -6dB internal jumpers (to apply a -6dB attenuation to audio ouput), and set
the jumpers before rack mounting the switcher. See
page 2-12 for details on the jumpers.
Attach the provided rack mounting brackets
to the switcher with machine screws, as
shown at right, then fasten the
switcher to the rack using the
supplied machine screws.
For the models with
audio amplification
(MLS 506MA/SA) we
recommend allowing one
rack unit of space
(1.75”/4.5 cm) above and
below the switcher for air
circulation to prevent
overheating. There is no
cooling fan in the MLS
switcher.
To reduce the risk of fire or electric shock, do not expose this apparatus to
rain or moisture.
register, stove, or another apparatus (including amplifiers) that produces heat.
long periods.
CLIP
VOLUME
MIX
ADJUST
MLS 506
MENU NEXT
MediaLink Switcher
DOC
WORK
CELL CAMERA
MAC
TUNER
VCRDVD
1 2 3 456
Rack mounting the MediaLink Switcher
MLS 306 Rear Panel and Cabling
23456
100-240V 0.2A 50/60 Hz
1
.5A MAX
INPUT 1
LRLRLRLRLRLR
MLS 306 Rear Panel
MediaLink Switchers • Installation2-2
INPUT 2INPUT 3INPUT 4INPUT 5INPUT 6
RGBHV
OUTPUTS
R
BGH
LRLR
AUDIO OUT
V
FIXEDVARIABLE
ABC
MLC/IR
Y/C
CONTACT CLOSURE
VID
RS232
789
Power connection
AC power connector and power indicator LED — Plug a standard IEC power
1
cord into this connector to connect the switcher to a 100 to 240VAC, 50 Hz or
60 Hz power source. The LED ( ) lights while the MLS is receiving power.
Input connections
Inputs 1–3 — For inputs 1, 2, and 3, connect a cable from the video source to
2
either (choose one)
•the BNC connector (composite video) or
•the 4-pin mini DIN connector (S-video ).
Input configuration is not needed for these inputs.
For audio input, wire the audio input connector as shown in the following
illustration.
Tip
Sleeve
Tip
Sleeve
Unbalanced Stereo Input
(high impedance)
LR
Tip
Ring
Sleeve (s)
Tip
Ring
Balanced Stereo Input
(high impedance)(600 ohms)
LR
Sleeve (s)
600 ohms
Tip
Ring
Tip
Ring
600 ohms
Balanced Stereo Input
LR
Tip
Sleeve
Tip
Sleeve
Unbalanced Mono Input
(high impedance)
Inputs 4–6 — For inputs 4, 5, and 6, connect a computer to the 15-pin HD
3
connector for RGB computer video input.
Each input’s audio source can be connected to either the female 3.5 mm mini
stereo jack (unbalanced input), or the 3.5 mm, 5-pole captive screw connector
(balanced or unbalanced input).
Wire the stereo jack audio input connectors as
shown at right. Wire the captive screw
connectors as shown above in
Video output connections
RGB computer video outputs — Connect a cable from the 15-pin HD
4
connector or the five BNC connectors to the projector for computer video
output from inputs 4–6. The output signal will be in the same format
(RGBHV, RGBS, RGsB, RsGsBs) as the input signal. The signal is switched,
but not processed. The two RGB video outputs (15-pin HD and BNC
connectors) are simultaneously active. Cables can be connected between the
projector and one, some, or all of the switcher’s video outputs.
Cable the BNC connectors according to the signal format as shown below.
LR
Tip
Ring
Sleeve (s)
Tip
Ring
Balanced Mono Input
(high impedance)(600 ohms)
2
.
600 ohms
LR
Ring
Sleeve (s)
Ring
Tip
Tip
Balanced Mono Input
Tip (+)Sleeve (Gnd)
Ring (R, -)
LR
Tip (L, +)
Sleeve (Gnd)
5
6
RBGHV RBGHVRBGHV
RGBSRGBHVRGsB
(Sync on Green)
,
RsGsBs
S-video (Y/C) output — Connect a cable from these BNCs to the projector (Y/
luma on left, C/chroma on the right) for S-video output.
Composite video (Vid) output connector — Connect a cable from this BNC
connector to the projector for composite video output.
2-3MediaLink Switchers • Installation
Installation, cont’d
Audio output connections
Audio Out(put) connectors — Connect an audio output device to either
7
connector for balanced or unbalanced stereo audio output. A device such as a
tape recorder can be connected to the Fixed output while a power amplifier
can be connected to the Variable output. Wire each captive screw connector as
shown below.
Tip
See Caution
Sleeve (s)
Tip
See Caution
Unbalanced Output
AUDIO OUT
LR
Balanced Output
Tip
Ring
Sleeve (s)
Tip
Ring
AUDIO OUT
LR
CAUTION
Connect the sleeve to ground (Gnd). Connecting the sleeve to a negative
(-) terminal will damage the audio output circuits.
The Fixed connector outputs audio at a fixed level and is unaffected by
changes made via the front panel Volume/Adjust knob. The Variable
connector outputs audio that can be attenuated by turning the Volume knob.
Control connections
MLC/IR port — Connect a cable between this port and an optional Extron
8
MLC 206 MediaLink Controller or an optional IR Link IR signal repeater.
• The MLC provides remote control of input switching and volume.
• The IR Link accepts modulated IR signals from a remote control so the
remote control can be used for selecting the switcher’s inputs.
Extron Comm-Link cable is recommended for this connection. If you use
Comm-Link cable, the switcher and controller can be up to 250 feet (76.2 m)
apart. Wire the captive screw connector for connection to either an IR Link or
an MLC 206 as shown below.
MLC/IR
ABC
MediaLink Switcher to an IR Link
Switcher
rear panel
MLC/IR port
C
+12VDC
Ground ( )
IR (IR Link)
100-240V 0.2A 50/60 Hz
INPUT 1
INPUT 2 INPUT 3 INPUT 4 INPUT 5 INPUT 6
ABCDE
IR Link
port
IR
D
LR LR LR LR LR LR
.5A MAX
MLS 306 Rear Panel
MLA-Remote
R
BGH
V
Y/C
RGBHV
AUDIO OUT
FIXED VARIABLE
OUTPUTS
LRLR
VID
MLC/IR
ABC
RS232
CONTACT CLOSURE
SIGNAL
IR LINK
IR Link
MLC/IR
ABC
MediaLink
Switcher
rear panel
MLC/IR port
NOTE If you use cable that has a
MediaLink Switcher to an MLC 206
MediaLink Switchers • Installation2-4
+12VDC
Ground ( )
B
Receive (Rx)
A
Transmit (Tx)
+12VDC
Ground ( )
Transmit (Tx)
Receive (Rx)
drain wire, tie the drain wire
to ground at both ends.
B
A
AB
MLS / Power
100-240V 0.2A 50/60 Hz
.5A MAX
MLS 306 Rear Panel
MLC
MLS/Power
port
R
BGH
IR
DEABCABD
1A 1B 2A 2B 3A 3B
RS-232
Relays IR/RCM
RGBHV
AUDIO OUT
FIXED VARIABLE
OUTPUTS
LRLR
123456
Extron Switcher Control
INPUT 1
INPUT 2 INPUT 3 INPUT 4 INPUT 5 INPUT 6
LR LR LR LR LR LR
ABCDE ABC
Display/Source Control
MLC 206 Bottom Panel
NOTE The switcher provides
power to the controller.
Tally Out
V
Y/C
VID
MLC/IR
ABC
RS232
CONTACT CLOSURE
33-644-01 A
07 01
Printed in the
USA
MLS
/Power
Do not connect RS-232 control devices to the MLC/IR 5-pole captive screw
connector and to the 9-pin RS-232/Contact Closure port simultaneously. A
conflict may occur.
Connect devices to both ports at the same time only if
• the 9-pin connector is used for contact closure and
• the MLC/IR port is used for RS-232.
RS-232/Contact Closure port — This port can function as an RS-232 port or as
9
a contact closure port. Do not connect RS-232 devices to both this and the
MLC/IR port. See the above note.
•For a stand-alone MLS switcher, connect a cable from the host computer
or a third party control system to this 9-pin D connector to set up and
remotely control the switcher. Alternatively, connect a contact closure
keypad to this connector for remote control of input selection.
•For an MLS switcher slaved to an MLC controller, connect a cable from
the MLC’s MLS/Power port to the switcher’s MLC/IR connector (not to
this 9-pin RS-232 port). Once the system has been cabled and set up via
the Windows-based software, the MLC or a host computer
communicating through the MLC can be used to remotely control the
switcher. Refer to chapter four of the MLC 206 User’s Manual and the
MediaLink Control Program help file for details on configuring an MLCMLS system.
CAUTION
If the switcher is connected to an MLC 206 controller via the MLC/IR
port, do not connect an RS-232 device to the MLS’s 9-pin RS-232/Contact
Closure port. Conflicts between RS-232 signals received from both ports
could cause system disruptions.
When an MLC 206 is connected to the MLC/IR port, a contact closure
device may be attached to the 9-pin connector.
2-5MediaLink Switchers • Installation
Installation, cont’d
MLS 506, MLS 506MA, and MLS 506SA
Rear Panels and Cabling
23456
100-240V 0.2A 50/60 Hz
1
.5A MAX
MLS 506 Rear Panel
100-240V 0.2A 50/60 Hz
1
.5A MAX
MLS 506 MA Rear Panel
INPUT 1
VIDEO
Y
C
LLRRLR
INPUT 2
R-Y
VIDEO
R-Y
VIDEO
Y
B-Y
B-Y
C
234567
INPUT 1
VIDEO
Y
C
LLRRLR
INPUT 2
R-Y
VIDEO
R-Y
VIDEO
Y
B-Y
B-Y
C
INPUT 3
Y
C
INPUT 3
Y
C
R-Y
B-Y
R-Y
B-Y
INPUT 4
RH/
G
B
INPUT 4
RH/
G
B
INPUT 5
RH/
HV
V
LRLRLR
HV
V
LRLRLR
HV
V
G
B
INPUT 5
RH/
HV
V
G
B
INPUT 6
RH/
HV
V
G
B
INPUT 6
RH/
HV
V
G
B
YUV
RGB
RH/
G
B
RH/
G
B
SENDLRRETURN
LR
R-Y
HV
Y
V
B-Y
YUV
RGB
R-Y
HV
Y
V
B-Y
AUX/MIXEFFECTS
LR
911
101213
S-VIDEO
Y
C
S-VIDEO
Y
C
VIDEO
VIDEO
AUDIO OUT
11
AUDIO OUT
LRLR
LRLR
MLC/IRRS232
FIXEDVARIABLE
ABC
MONO AMPLIFIED OUTPUT
4 ohm
COMM8 ohm 70V
MLC/IRRS232
FIXEDVARIABLE
ABC
CONTACT CLOSURE
1213
CONTACT CLOSURE
100-240V 0.2A 50/60 Hz
1
.5A MAX
MLS 506 SA Rear Panel
Power connection
Input connections
234568
INPUT 1
VIDEO
Y
C
LRLRLRLRLRLR
INPUT 2
VIDEO
R-Y
Y
B-Y
C
AC power connector and power indicator LED — Plug a standard IEC power
1
INPUT 3
VIDEO
R-Y
Y
B-Y
C
R-Y
B-Y
INPUT 4
RH/
HV
V
G
B
INPUT 5
RH/
HV
V
G
B
INPUT 6
RH/
G
B
cord into this connector to connect the switcher to a 100 to 240VAC, 50 Hz or
60 Hz power source. The LED ( ) lights while the MLS is receiving power.
Inputs 1–3 — For inputs 1, 2, and 3, connect cables from the video sources to
2
the MLS’s input BNC connectors according to the video format as shown in
the following illustration. You must also select between “Vid” (for composite
video or S-video) and “YUV” (for component video) in the LCD menu or via
the Windows-based setup program. See pages 3-5, 3-6, and 4-9.
HV
V
YUV
R-Y
Y
B-Y
AUX/MIXEFFECTS
LR
S-VIDEO
Y
C
VIDEO
AUDIO OUT
11
FIXEDVARIABLE
LRLR
STEREO AMPLIFIED OUTPUT
LEFTRIGHT
MLC/IRRS232
ABC
RGB
RH/
HV
V
G
B
SENDLRRETURN
LR
9101213
CONTACT CLOSURE
MediaLink Switchers • Installation2-6
VIDEO
VIDEO
VIDEO
R-Y
R-Y
R-Y
Y
B-Y
C
Composite
video
Y
C
S-video
(Y, C)
B-Y
Y
B-Y
C
Component
video
(R-Y, Y, B-Y)
Video input connections for MLC 506/506MA/506SA inputs 1–3
For audio input, wire the audio input connector as shown below.
Sleeve
Sleeve
Tip
Tip
LR
Unbalanced Stereo Input
(high impedance)
Sleeve
Sleeve
Tip
Tip
LR
Unbalanced Mono Input
(high impedance)
Inputs 4–6 — For inputs 4, 5, and 6, connect a computer to the
3
Tip
Ring
Sleeve (s)
Tip
Ring
Balanced Stereo Input
(high impedance)(600 ohms)
Tip
Ring
Sleeve (s)
Tip
Ring
Balanced Mono Input
(high impedance)(600 ohms)
LR
LR
600 ohms
Tip
Ring
Sleeve (s)
Tip
Ring
600 ohms
Balanced Stereo Input
600 ohms
Tip
Ring
Sleeve (s)
Tip
Ring
Balanced Mono Input
appropriate BNC connectors for RGB computer video input.
LR
LR
RH/
HV
V
G
B
RGBHV
(separate
H & V sync)
RH/
GV
B
Connect each input’s stereo audio source to the 3.5 mm, 5-pole captive screw
connector for balanced or unbalanced input. Wire the audio input connectors
as shown above in
Video output connections
RGB computer video output — Connect coaxial cables from these five BNC
4
connectors to the projector for computer video output from inputs 4–6. Cable
the BNC connectors according to the signal format as shown in the following
illustration. The output signal will be in the same format (RGBHV, RGBS,
RGsB, RsGsBs) as the input signal. The signal is switched, but not processed.
Cables can be connected between the projector and one, some, or all of the
switcher’s video outputs.
HV
RGBS
(composite
sync)
.
2
RH/
HV
GV
B
RGsB/RsGsBs
(sync on green; or
sync on red, green, & blue)
2-7MediaLink Switchers • Installation
Installation, cont’d
Cable the BNC connectors according to the signal format as shown below.
RH/
HV
V
G
B
RGBHV
(separate
H & V sync)
RH/
GV
B
RGB output connections for MLC 506/506MA/506SA
Component video (YUV) output — Connect a cable from these three BNC
5
connectors to the projector for component output.
Composite video (Video) and S-video outputs — Connect a cable from the
6
top BNC connector for composite video output to the projector. Connect a
cable from the lower two BNC connectors to the projector for S-video output.
Audio output connections
Mono Amplified Output (MLS 506MA only) — Cable speakers to this
7
output for 30 watt amplified mono audio output. This output provides a
mono signal even if the input is a stereo signal. The Audio Out captive screw
11
connectors (
Follow the appropriate Mono Amplified Output wiring diagram for the type
MONO AMPLIFIED OUTPUT
COMM8 ohm 70V
MONO AMPLIFIED OUTPUT
COMM8 ohm 70V
) can output stereo audio.
4 ohm
4 ohm
HV
RGBS
(composite
sync)
Mono +
Ground ( )
sync on red, green, & blue)
Mono +
RH/
HV
GV
B
RGsB/RsGsBs
(sync on green; or
4 Ohm Load
of load you want
to use: 4 ohm,
8 ohm, or a
distributed 70 volt
or 100 volt
(depending on the
model) system.
The 70 volt model
is shown here; the
wiring is the same
for both versions
of the MLS 506MA.
Two 8 ohm speakers in
parallel make a 4 ohm load.
Connecting a 4 ohm load to the mono amplified ouput
MediaLink Switchers • Installation2-8
MONO AMPLIFIED OUTPUT
4 ohm
COMM8 ohm 70V
Ground ( )
4 Ohm Total Load
Mono +
Ground ( )
8 Ohm Load
Mono +
MONO AMPLIFIED OUTPUT
4 ohm
COMM8 ohm 70V
Ground ( )
Two 4 ohm speakers in
series make an 8 ohm load.
8 Ohm Total Load
Connecting an 8 ohm load to the mono amplified output
70V
or
100V
MONO AMPLIFIED OUTPUT
4 ohm
COMM8 ohm 100V
70V
Ground ( )
100V Speakers
(depending
on the model)
Connecting a 70 or 100 volt system to the mono amplified output
or
CAUTION
Connect a 70 volt speaker system to the 70 volt model, and connect a 100
volt speaker system to the 100 volt model. Connecting a 70 volt speaker
system to the 100 volt model can cause damage to the switcher and
speakers and create a safety hazard.
Stereo Amplified Output (MLS 506SA only) — Cable speakers to this output
8
for 30 watt amplified stereo audio output. Wire the connector as shown
below for stereo output to 4 ohm or 8 ohm loads.
Left +
4 Ohm or
8 Ohm
Left –
STEREO AMPLIFIED OUTPUT
LEFTRIGHT
Stereo amplified output:
30 watts per channel into a 4 ohm or 8 ohm load.
NOTE
You must also select the appropriate
speaker load (4 ohm or 8 ohm) from
the SpkrLoad submenu of the Audio
Settings LCD menu or via the
control software.
Right –
4 Ohm or
8 Ohm
Right +
2-9MediaLink Switchers • Installation
Installation, cont’d
Audio Out(put) connectors — Connect an audio output device to either
11
connector for balanced or unbalanced audio output. A device such as a tape
recorder can be connected to the Fixed output while speakers can be connected
to the Variable output. Wire each captive screw connector as shown below.
Tip
See Caution
Sleeve (s)
Tip
See Caution
Unbalanced Output
AUDIO OUT
LR
Balanced Output
Tip
Ring
Sleeve (s)
Tip
Ring
AUDIO OUT
LR
CAUTION
Connect the sleeve to ground (Gnd). Connecting the sleeve to a negative
(-) terminal will damage the audio output circuits.
The Fixed connector outputs audio at a fixed level and is unaffected by
changes made via the front panel Volume/Adjust knob. The Variable
connector outputs audio that can be attenuated by turning the Volume knob.
These preamp outputs can be set for mono or stereo output via the front panel
menu or the control software.
Audio processing connections — MLS 506MA, MLS 506SA only
Effects connectors (Send, Return) — These two 3.5 mm, 3-pole captive screw
9
connectors allow the selected audio signal to be looped through an optional
recording device or equalizer before being sent to the main Audio Output (
(preamp outputs) or the amplified audio output (
We recommend using shielded cables no longer
than 10 feet (3 meters). These connectors should be
wired as shown at right.
An active, unbalanced signal is always available at
the Send connector. The Return connector accepts
the unbalanced signal that has been routed through
an external device. In order for the
Return connector to accept an incoming/
returning audio signal, you must enable
the Return port via the front panel LCD
menu (see pages 3-5 and 3-6) or the
Windows-based setup program.
or 8).
7
Left
Gnd ( )
Right
EFFECTS
RETURN
SEND
LR
LR
Audio Processing
Device
Right
Gnd ( )
Left
)
11
Aux/Mix input connector — An auxiliary balanced or unbalanced line level
10
audio signal input at this connector can be mixed with the signal from the
selected audio input. Use the front panel Mix knob to control the level of this
auxiliary signal. Wire the connector as shown below, which is the same as the
wiring for audio inputs 1–6.
Tip
Sleeve
Tip
Sleeve
Unbalanced Stereo Input
Tip
Sleeve
Tip
Sleeve
Unbalanced Mono Input
MediaLink Switchers • Installation2-10
(high impedance)
(high impedance)
LR
LR
Tip
Ring
Sleeve (s)
Tip
Ring
Balanced Stereo Input
(high impedance)(600 ohms)
Tip
Ring
Sleeve (s)
Tip
Ring
Balanced Mono Input
(high impedance)(600 ohms)
LR
Sleeve (s)
LR
Sleeve (s)
600 ohms
Tip
Ring
Tip
Ring
600 ohms
Balanced Stereo Input
600 ohms
Tip
Ring
Tip
Ring
Balanced Mono Input
LR
LR
Control connections
MLC/IR port — This port allows you to provide remote control of the
12
switcher. Connect a cable between this port and an optional Extron MLC 206
MediaLink Controller or an optional IR Link IR signal repeater.
• The MLC provides remote control of input switching and volume.
• The IR Link accepts modulated IR signals from a remote control so the
remote control can be used for selecting the switcher’s inputs.
Extron Comm-Link cable is recommended for this connection. If you use
Comm-Link cable, the switcher and controller can be up to 250 feet (76.2 m)
apart. Wire the captive screw connector for connection to either an IR Link or
an MLC 206 as shown below.
MLC/IR
ABC
Switcher
rear panel
MLC/IR port
C
MediaLink Switcher to an IR Link
+12VDC
Ground ( )
IR (IR Link)
ABCDE
IR
IR Link
port
100-240V 0.2A 50/60 Hz
.5A MAX
INPUT 1
INPUT 2
VIDEO
R-Y
VIDEO
R-Y
Y
Y
B-Y
B-Y
C
C
LLRRLR
INPUT 3
VIDEO
Y
C
INPUT 4
R-Y
RH/
HV
V
G
B-Y
B
LR LR LR
RH/
G
B
INPUT 5
HV
V
RH/
G
B
YUV
INPUT 6
HV
VIDEO
RGB
RH/
V
G
B
SENDLRRETURN
LR
MONO AMPLIFIED OUTPUT
R-Y
HV
S-VIDEO
4 ohm
COMM 8 ohm 70V
Y
Y
V
B-Y
C
AUX/MIXEFFECTS
MLC/IR RS232
AUDIO OUT
FIXED VARIABLE
ABC
LR
LRLR
CONTACT CLOSURE
MLS 506MA Rear Panel
D
MLA-Remote
SIGNAL
IR LINK
IR Link
MLC/IR
ABC
MediaLink
Switcher
rear panel
MLC/IR port
100-240V 0.2A 50/60 Hz
.5A MAX
INPUT 1
INPUT 2
VIDEO
VIDEO
R-Y
Y
Y
B-Y
C
C
LLRRLR
R-Y
B-Y
INPUT 3
VIDEO
Y
C
INPUT 4
RH/
R-Y
HV
G
B-Y
B
LR LR LR
INPUT 5
INPUT 6
RH/
V
G
B
RGB
RH/
RH/
HV
HV
HV
V
V
V
G
G
B
B
SENDLRRETURN
LR
MLS 506MA Rear Panel
ABCDE ABC
DEABCABD
+12VDC
Ground ( )
B
Receive (Rx)
A
Transmit (Tx)
+12VDC
Ground ( )
Transmit (Tx)
Receive (Rx)
NOTE If you use cable that has a
drain wire, tie the drain wire
to ground at both ends.
B
A
AB
MLS / Power
MLC
MLS/Power
port
NOTE The switcher provides
1A 1B 2A 2B3A 3B
IR
RS-232
Display/Source Control
Relays IR/RCM
MLC 206 Bottom Panel
power to the controller.
MediaLink Switcher to an MLC 206
If the switcher is connected to an MLC 206 controller via the MLC/IR port, do
not connect an RS-232 device to the MLS’s 9-pin RS-232/Contact Closure
port. The 9-pin D and 5-pole captive screw connectors are both for RS-232
control.
Connect devices to both ports at the same time only if
• the 9-pin connector is used for contact closure and
• the MLC/IR port is used for RS-232.
RS-232/Contact Closure port — This port can function as an RS-232 port or as
13
a contact closure port. Do not connect RS-232 devices to both this and the
MLC/IR port. See the above note.
•For a stand-alone MLS switcher, connect a cable from the host computer
•For an MLS switcher slaved to an MLC controller, connect a cable from
CAUTION
RS-232
function
Description
Contact closure
51
96
DB9 Pin Locations
Female
or a third party control system to this 9-pin D connector to set up and
remotely control the switcher. Alternatively, connect a contact closure
keypad to this connector for remote control of input selection.
the MLC’s MLS/Power port to the switcher’s MLC/IR connector (not to
the 9-pin RS-232 port). Once the system has been cabled and set up via
the Windows-based software, the MLC or a host computer communicating through the MLC can be used to remotely control the switcher. Refer
to chapter four of the MLC 206 User’s Manual and the MediaLink Control
Program help file for details on configuring an MLC-MLS system.
If the switcher is connected to an MLC 206 controller via the MLC/IR
port, do not connect an RS-232 device to the MLS’s 9-pin RS-232/Contact
Closure port. Conflicts between RS-232 signals received from both ports
could cause system disruptions.
When an MLC 206 is connected to the MLC/IR port, a contact closure
device may be attached to the 9-pin connector.
Setting the -6dB Jumpers
In the MLS switchers, when audio signals are converted from an unbalanced input
to a balanced output, an additional +6dB gain is applied to the output signal. To
remove the +6dB gain from the balanced output or to apply a 6dB attenuation to
unbalanced output, jumper headers have been applied to pins inside the switcher.
The jumper headers can be removed if you would like to restore the +6dB gain.
The -6dB attenuation can be set separately for the left and right audio channels by
removing one of the jumper headers.
Input signal
UnbalancedUnbalanced-6dB0dB
UnbalancedBalanced0dB+6dB
BalancedUnbalanced-6dB0dB
BalancedBalanced0dB+6dB
CAUTION
Follow these steps to set the -6dB jumpers in any MediaLink Switcher.
1.Disconnect the AC power cord from the MLS to remove power from the unit.
Output signal
Changes to settings inside the unit must be performed by authorized
service personnel only.
To prevent electric shock, always unplug the MLS switcher from the AC
power source before opening the enclosure.
Gain/attenuation
Gain/attenuation
with jumperswithout jumpers
MediaLink Switchers • Installation2-12
2.Remove the switcher from the rack, or furniture and set it on a level, stable
surface.
3.Remove the cover of the switcher (the top half of the enclosure) by removing
the screws, then lifting the cover straight up. Set the cover down on a level
surface, and save the screws for later use.
CAUTION
Do not touch any switches or other electronic components inside the
switcher. Doing so could damage the switcher. Electrostatic discharge
(ESD) can damage IC chips even though you cannot feel it. You must be
electrically grounded before proceeding with jumper installation or
replacement. A grounding wrist strap is recommended.
4.Locate the pairs of pins labeled JMP1 and JMP2 on the circuit board, as
shown in the boxed area of the following picture, which shows the pins with
the jumpers already set for the -6dB attenuation. The MLS 506MA is shown in
the example below, but these jumpers are in the same location in all models.
MLS 506MA Rear Panel (Top View)
MLS 506MA Front Panel
(Top View)
5.After you are electrically
6.Replace the top cover on the switcher, and fasten it with the screws that were
7.Rack mount the switcher or mount it into the furniture.
8.Reconnect the AC power cord.
grounded, place a jumper on
the pins for the audio channel to
which the -6dB attenuation will
be applied, or remove a jumper
to remove the attenuation.
• JMP1 is for the left audio
channel.
• JMP2 is for the right audio
channel.
The picture at right shows
jumpers set for both left and
right channels.
removed in step 3.
JMP1 and JMP2 -6dB Audio Jumpers
2-13MediaLink Switchers • Installation
Installation, cont’d
Application Diagrams
BUFFERED
PC Audio
LOCAL MONITOR
Input
COMPUTER
ID PIN 4
INPUT
ID PIN11
P/2 DA2 MT
Extron
P/2 DA2 MT
70V Mono Distribution
Laptop
DVD
VCR
DISPLAY
POWER
MLC 206
VOLUME
MediaLink Controller
MAX/
MIN
Extron
Extron MLC 206
or
RS-232 Control
PC Computer
Stereo Amplified Output
Extron
MLS 506SA
INPUT 4
R H/
H/
HV
INPUT 3
R
G V
R-Y
INPUT 2
VIDEO
G V
B
R-Y
INPUT 1
Y
VIDEO
R
B
L
R-Y
B-Y
Y
C
VIDEO
R
L
B-Y
Y
C
L R
B-Y
C
R
L
100-240V 0.2A 50/60 Hz
Extron MLS 306
VCR
70V
8 ohm
4 ohm
MONO AMPLIFIED OUTPUT
VIDEO
COMM
YUV
RS232
RGB
S-VIDEO
R-Y
E
D
COMM LINK
C
H/
CONTACT CLOSURE
Y
B
HV
A
INPUT 6
R
Y
AUDIO OUT
L R
C
HV
INPUT 5
G V
B-Y
AUX/MIX
R H/
LR
HV
EFFECTS
RETURN
B
G V
R
SEND
L
R
L
B
L R
R
L
VID
RS232
Y/C
E
D
V
COMM LINK
C
CONTACT CLOSURE
B
A
H
AUDIO OUT
BG
L R
R
RGBHV
OUTPUTS
R
INPUT 6
L
R
INPUT 5
L
R
INPUT 4
L
INPUT 3
LR
INPUT 2
R
L
INPUT 1
R
L
100-240V 0.2A 50/60 Hz
DVD
RGB Document
Camera
Laptop
w/ Audio
Extron
Audio
Amplifier
Laptop
DVD
VCR
DISPLAY
POWER
MLC 206
VOLUME
MediaLink Controller
X/
A
M
IN
M
Extron MLC 206 or
Projector Control
Laptop
w/ Audio
RS-232 Control
Projector
Projector Control
VCR
MediaLink Switchers • Installation2-14
DVD
AUDIO
EXTENDER WM
Wall Plate
Video Camera
RGB Document
Camera
INPUT
BUFFERED LOCAL
MONITOR OUTPUT
H. SHIFT
ID PIN 4
ID PIN 11
VGA INTERFACE W /ADSP
RGB 109 xi
PC Computer
Projector
xi
MediaLink Switchers
Chapter Three
3
Operation
Front Panel Features and Basic Operation
Menus, Configuration, and Adjustments
Remote Control of the MLS
Operation
Front Panel Features and Basic Operation
MediaLink switcher can be set up and operated by using:
• The front panel controls.
• A computer, a touch screen panel, or any other device that can send and receive
the serial communications through the RS-232 port. Extron’s Simple
Instruction Set™ (SIS™) is a set of simple keystroke commands that can be
used with any such devices, and Extron’s control software for Windows
provides a graphical interface for controlling the switcher from a computer.
This gives you full control of switching, volume adjustment, and all setup
steps.
• A contact closure device (for input selection only).
• An infrared remote control, such as the MLA-Remote, in conjunction with the
IR Link infrared repeater (for input selection and volume adjustment).
Some settings can be adjusted only through a host computer. For details on serial
communications control via the RS-232 port, see chapter four, “Serial Communication”.
213457
MLS 306 Front Panel
MLS 506 Front Panel
WORK
VCRDVD
123456
TUNER
MAC
DOC
CELL CAMERA
213457
WORK
VCRDVD
123456
TUNER
MAC
DOC
CELL CAMERA
21345678
WORK
VCRDVD
123456
TUNER
MAC
DOC
CELL CAMERA
MENU NEXT
MENU NEXT
MENU NEXT
VOLUME
ADJUST
VOLUME
ADJUST
MIX
VOLUME
ADJUST
MLS 306
MediaLink Switcher
MLS 506
MediaLink Switcher
CLIP
MLS 506MA Front Panel (same as MLS 506SA)
Power LED — This LED lights when the MLS receives power.
1
Input selection buttons, LEDs, and button labels — Press and release one of
2
these buttons to select an input (1–6). The corresponding LED lights to
indicate the selected input.
MediaLink Switchers • Operation3-2
MLS 506MA
MediaLink Switcher
Audio and video signals can be switched separately (broken away from each
other) via the User Mode screen of the control software. If the signals are
switched separately, the LED above the audio input’s button blinks, and the
LED above the video input’s button lights steadily.
The labels above the LEDs can be replaced. See appendix B in this manual for
details.
LCD— This two-row liquid crystal display provides a way to see the menus
3
and options for setting up the switcher. During regular operation the LCD
displays the following messages:
EXTRON
MLS 506
Menu button — Press this button to enter the setup menus and to move from
4
2 sec.
2 sec.
INPUT
#6
menu to menu. The Menu and Next buttons are also used to enable/disable
the executive mode. See the note below.
Next button — When the MLS’s setup menus are active, press this button to
5
enter a specific submenu or to move between options within a submenu.
Press the Menu and Next buttons simultaneously for three seconds to enable/
disable the executive mode. When executive mode is enabled, adjustments
and changes to switcher setup cannot be made from the front panel controls.
Only input selection and adjustments to overall volume and mixer levels are
allowed. See page 3-7.
Mix knob (MLS 506 MA and MLS 506 SA only) — Turn this knob to adjust
6
the level of the Aux/Mix audio input. This control determines how much
gain or attenuation is applied to the Aux/Mix channel and, therefore, how loud
the auxiliary audio sounds. This knob has no function during setup.
There is no physical limit to this knob’s rotation. During mix level adjustment
the LCD screen displays the level (shown below), and also indicates when the
knob has reached its functional minimum (0) or maximum (100) limit.
Mix
Min
AttenuationGain
Volume/Adjust(ment) knob — While in the regular operating mode, turn this
7
MIXMIXMIXMIX
Mix
014
Mix
050
Mix
079
knob to adjust the master audio volume for the Audio Out preamp audio
outputs (and the amplified output on the MA and SA models). There is no
physical limit to this knob’s rotation. During volume adjustment the LCD
screen displays the level (shown below), and also indicates when the knob has
reached its functional minimum (0) or maximum (100) limit. The minimum
setting produces 100% signal attenuation.
Volume
Min
100%
attenuation
VOLUME
ADJUST
Volume
007
VOLUME
ADJUST
Volume
050
VOLUME
ADJUST
Volume
086
VOLUME
ADJUST
When the setup menus are active, turn the Volume/Adjust knob to make
adjustments to switcher settings.
Clip LED (MLS 506MA and MLS 506SA only) — This LED flashes when the
8
audio level for a particular input is too high. If the audio level exceeds the
point at which the Clip LED flashes, the audio will be clipped, which results
in a distorted output. Adjust the output level of the active source or the input
level at the switcher (via the front panel LCD Audio Adjust menu or via the
control software) so clipping does not occur.
Mix
Max
Volume
Max
0%
attenuation
3-3MediaLink Switchers • Operation
Operation, cont’d
Menus, Configuration, and Adjustments
Switcher configuration and adjustments can be performed by using the Windowsbased control program (see chapter 4 for details) or by using the front panel
controls and the menus that are displayed on the LCD screen. These menus are
used primarily when the switcher is first set up.
Moving through menus by using front panel controls
Menu button — Press the Menu button to activate menus and to move to the four
main menus.
Next button — Press the Next button to move between the submenus of a selected
main menu. Pressing the Next button during video configuration causes the
current input’s number and video format type to be displayed on the LCD.
Volume/Adjust knob — In configuration mode rotate this knob to scroll through
submenu options and to make selections and adjustments. Settings and
adjustments are stored in nonvolatile memory.
Input selection buttons — When a menu or submenu is active, press an input
selection button to select that input for configuration.
Menu overview
The default menus appear on the LCD when no adjustments are actively being
made. They cycle between the screen showing the name of the switcher and the
screen that shows the active input’s number, as shown below.
Power
on
FIRMWARE
Ver 1.XX
Default menus immediately after power-on or
when audio & video are switched together
EXTRON
MLS 506
2 sec.
2 sec.
INPUT
#6
EXTRON
MLS 506
Default menus during breakaway
(via RS-232) when audio
was most recently switched
2 sec.
2 sec.
AUDIO
INPUT #2
From any menu or submenu,
after seven seconds of
inactivity the MLS will save all
adjustment settings and timeout to the default menus.
The main menus are as shown at right. Use
the Menu button to scroll between them.
To return to the default screens,
let the MLS time-out for 7
seconds, or press the Menu button
until Exit Menu appears, then
press the Next button.
EXTRON
MLS 506
Default menus during breakaway
(via RS-232) when video
was most recently switched
Power
on
FIRMWARE
Ver 1.XX
EXTRON
MLS 506
2 sec.
2 sec.
2 sec.
2 sec.
MENU
VIDEO
CONFIG
MENU
AUDIO
ADJUST
MENU
AUDIO
SETTINGS
MENU
VIDEO
INPUT #5
INPUT
#6
MediaLink Switchers • Operation3-4
NEXT
or timeout
EXIT
MENU
MENU
The following flowchart shows the main menus and submenus available for all
four switcher models. Items within the dashed lines are not offered on all models.
Power
on
FIRMWARE
Ver 1.XX
EXTRON
MLS506SA
2 sec.
2 sec.
MENU
VIDEO
CONFIG
MENU
AUDIO
ADJUST
MENU
INPUT
#2
Select the video type
for inputs 1–3.
NEXT
NEXT
Default: Vid.
Input #2
<Vid>YUV
VOLUME
ADJUST
Input #2
Vid<YUV>
Set audio output level
per input.
MLS 306/506: -15dB to +09dB
MLS 506MA/506SA: 0 to 100 steps
Level
#2 050
VOLUME
selection/configuration is not available
Video input format
or necessary for the MLS 306.
Select
another
input.
NEXT
Input #3
<Vid>YUV
35
VOLUME
ADJUST
Input #3
Vid<YUV>
Adjust bass
per input (2dB
increments).
-14dB to +14dB
Bass
#2 +00dB
VOLUME
Select
another
input.
NEXT
Inputs 4–6
are RGB only.
Input #5
RGB Only
Adjust treble
per input (2dB
increments).
-14dB to +14dB
Treble
#2 +00dB
VOLUME
NEXT
RGB delay time:
0 seconds to 5
seconds in 0.5
sec. intervals.
RGBdelay
0.0 sec
VOLUME
ADJUST
RGBdelay
5.0 sec
NEXT / MENU
MENU
NEXT
or timeout
AUDIO
SETTINGS
MENU
EXIT
MENU
ADJUST
Level
#2 067
Set the overall
left / right audio
output balance.
NEXTNEXT
Balance
––––––––
VOLUME
ADJUST
Balance
––––––––
ADJUST
Bass
#2 -08dB
Stereo: Audio Out
outputs stereo audio.
Mono: the Audio Out
signal is the same
on both left & right.
Output
M<Stero>
VOLUME
ADJUST
Output
<Mono>St
ADJUST
Treble
#2 +06dB
MENU
The Effects submenu
is available for the
MLS 506MA and
MLS 506SA only.
Default: the Effects
Return is disabled.
Enable: the Effects
NEXT
Return will be active,
its input will be
to the Audio Out
amplified outputs.
Effects
E<Dsabl>
VOLUME
ADJUST
Effects
<Enabl>D
sent
and
NEXT
The Speaker Load
submenu is
available for the
MLS 506SA only.
4ohm: 4 ohm load
on stereo amplified
output.
8ohm: 8 ohm load
on stereo amplified
output.
SpkrLoad
<4ohm> 8
VOLUME
ADJUST
SpkrLoad
4 <8ohm>
NEXT / MENU
3-5MediaLink Switchers • Operation
Operation, cont’d
Menu details
Video Config(uration) menu
For the MLS 506, MLS 506MA, and MLS 506SA, the Video Config menu provides a
way to set the video format for inputs 1, 2, and 3. Select between Vid (for
composite video or S-video input) and YUV (component video) input. By default
inputs 4–6 are always RGB computer video.
The RGB delay (Triple-Action Switching delay) (the time when the screen goes
black during RGB input switching) for inputs 4, 5, and 6 can be set from this menu
for all MLS switchers. The period can be from 0 seconds to 5 seconds long.
Audio Adjust(ment) menu
From this menu you can set each input’s audio output level and bass and treble
adjustments.
The Level adjustment range is -15dB to +9dB for the MLS 306 and MLS 506, but it is
0 steps through 100 steps for the MLS 506MA and MLS 506SA. For all models
when the minimum limit of level adjustment is reached, the level number (-15dB or
000) is replaced by MIN. When the maximum limit of level adjustment is reached,
the level number (+09dB or 100) is replaced by MAX.
Audio Settings menu
Audio balance
The system’s overall (global) left/right audio balance can be set from the Balance
submenu. As the indicator on the LCD screen moves toward the left, the right
audio channel is attenuated. As the indicator moves to the right, the left audio
channel is attenuated. In the center no attenuation is applied to either channel.
The balance adjustment is not applied to the MLS506MA’s 70V output.
Mono/stereo output
The Audio Out connectors (Fixed and Variable) can output either mono or stereo
audio signals. If Mono is selected from the Output submenu, the audio signal will
be the same on both the left and right channels. If Stero is selected, the switcher
will send out different (stereo) signals on the left and right channels.
Effects — MLS 506MA and MLS 506SA only
For the MLS 506MA and MLS 506SA, the Effects submenu lets you choose whether
to enable the Effects Return connector.
• If the Effects setting is disabled, the Effects Send connector still outputs an audio
signal (to a tape deck, for example), but the Effects Return connector will be
internally disabled so any audio signal present there will not reach the Audio
Out or amplified output connectors.
• If the Effects setting is enabled, any audio signal input via the Effects Return
connector will be output via the Audio Out connector and the amplified
output (if applicable).
System reset
To reset all the switcher’s settings to the factory defaults, press and hold the Menu
and Next buttons while connecting the switcher to the AC power source.
MediaLink Switchers • Operation3-6
Executive mode
Executive mode locks all front panel functions except input selection and volume
and mix adjustment; it disables setup menu options. When executive mode is
active, all functions and adjustments can still be made through RS-232 control. For
details on RS-232 control, see chapter four. To enable or disable executive mode,
from the main menu press the Menu and Next buttons simultaneously for three
seconds, as shown below.
Press
simultaneously
for 3 sec.
Extron
MLS 506
MENUNEXT
Press
simultaneously
for 3 sec.
MENUNEXT
Remote Control of the MLS
The MediaLink Switcher can be controlled by using its front panel controls; an
optional Extron infrared remote control and Extron IR Link; a contact closure
device; a MediaLink Controller, or an RS-232 control device or computer.
X-mode
enabled
X-mode
disabled
Extron
MLS 506
2 sec.
2 sec.
Input
#6
3-7MediaLink Switchers • Operation
Operation, cont’d
Troubleshooting
x
MediaLink Switchers • Operation3-8
MediaLink Switchers
Chapter Four
4
Serial Communication
RS-232 Programmer’s Guide
Control Software for Windows
Serial Communication
DB9 Pin Locations
Female
51
96
The MediaLink switcher can be remotely set up and controlled via a host computer
or other device (such as a control system) attached to the rear panel RS-232/
Contact Closure port. Alternatively, the switcher can be controlled by an optional
MediaLink Controller (MLC 206) (connected to the MLS’s MLC/IR port) or by an
RS-232 device acting through the MLC. The control device (host) can use either
Extron’s Simple Instruction Set (SIS) commands or the graphical control program
for Windows. For details on use and setup of a system that includes a MediaLink
Controller, see the MediaLink Controller User’s Manual.
The switcher uses a protocol of 9600 baud, 1 stop bit, no parity, and no flow control.
The rear panel RS-232 9-pin D connector has the following pin assignments:
SIS commands consist of one or more characters per field. No special characters
are required to begin or end a command sequence. When the MLS determines that
a command is valid, it executes the command and sends a response to the host
device. All responses from the switcher to the host end with a carriage return and
a line feed (CR/LF = ), which signals the end of the response character string. A
string is one or more characters.
MLS-initiated messages
When a local event such as a front panel selection or adjustment takes place, the
MLS responds by sending a message to the host. No response is required from the
host. The MLS-initiated messages are listed here (underlined).
(c)Copyright 2001, Extron Electronics, MediaLink Switcher MLS506SA, Vx.xx
The MLS sends the copyright message when it first powers on. Vx.xx is the
firmware version number. The MLS 506SA is used in this example.
X1
C hn
The MLS sends this response when an input is switched.
Error responses
When the MLS receives a valid SIS command, it executes the command and sends a
response to the host device. If the MLS is unable to execute the command because
the command is invalid or it contains invalid parameters, it returns an error
response to the host.
The error response codes and their descriptions are as follows:
E01 – Invalid input channel number (the number is too large)
E10 – Invalid command
E13 – Invalid value (the number is out of range/too large)
E14 – Invalid for this configuration.
(where X1 is the input number)
MediaLink Switchers • Serial Communication4-2
Using the command/response tables
The command/response tables on the next page list valid command ASCII codes, the
MLS’s responses to the host, and a description of the command’s function or the
results of executing the command. Upper and lower case characters may be used
interchangeably in the command field.
GIn
Set current input’s audio attenuation.X5 gInX8 Aud=X5 Set attenuation (in dB).
Increment current input’s gain.+GInX8 Aud=X4 Increase the gain by 1dB.
Decrement current input’s gain.-GInX8 Aud=X4 Decrease the gain by 1dB.
View current input’s audio gain level. GInX8 Aud=X4 Show the audio level.
*+GInX8 Aud=X4 Increase an input’s gain by 1 step.
X8
*-GInX8 Aud=X4 Decrease an input’s gain by 1 step.
X8
*GInX8 Aud=X4 Show an input’s audio level.
X4
GIn
Increment current input’s gain.+GInX8 Aud=X4 Increase the gain by 1 step.
Decrement current input’s gain.-GInX8 Aud=X4 Decrease the gain by 1 step.
View current input’s audio gain level. GInX8 Aud=X4 Show the audio level.
X8
Aud=X4 Set a single input’s gain/
attenuation (in steps).
X8
Aud=X4 Set the current input’s gain/
attenuation (in steps).
Audio treble adjustment (per input)
Set a specific input’s treble level.
X2*X9
>In
Example:4*6>InX2 Trb=-02Example: set input 4’s treble to -2dB.
Increment an input’s treble level.
Decrement an input’s treble level.
View a specific input’s treble level.X2* >InX2 Trb=X9 Show input X9’s treble level.
Increment current input’s treble level. + >InX2 Trb=X9 Increase the current input’s treble.
Decrement the current input’s treble. – >InX2 Trb=X9 Decrease the current input’s treble.
View the current input’s treble level. >InX2 Trb=X9 Show the current input’s treble level.
X2
Trb=X9 Set a specific input’s treble level.
X2
Trb=X9 Set the currently selected
input’s treble level.
MediaLink Switchers • Serial Communication4-4
Command/response table for SIS commands (continued)
Example:2*10<InX2 Bas=+06Example: set input 2’s bass to +6dB.
Increment an input’s bass level.
Decrement an input’s bass level.
View a specific input’s bass level.
Increment the current input’s bass. + <InX2 Bas=X9 Increase the current input’s bass.
Decrement the current input’s bass. – <InX2 Bas=X9 Decrease the current input’s bass.
View the current input’s bass level. <InX2 Bas=X9 Show the current input’s bass level.
X2
Bas=X9 Set a specific input’s bass level.
X2
Bas=X9 Set the currently selected
input’s bass level.
Audio mute (overall)
Mute on (fixed & variable audio outputs) 1ZAmt1Mute all audio outputs.
Mute off (fixed & variable audio outputs) 0ZAmt0Unmute all audio outputs.
View the audio mute status.ZAmt X7 Show the status of audio mute.
Volume adjustment (overall)
Set the overall output volume.
X10
VVol
Example:27VVol013 Example: set volume to 13.
Increment the volume.+VVol
Decrement the volume.-VVol
View the volume level.VVol
X10
Specify the volume for the
audio output.
X10
Increase audio output.
X10
Decrease audio output.
X10
Show the output volume.
Executive mode
Disable executive mode.0XExe0 Adjustments & selections can
be made from the front panel.
Enable (lock adjustments).1XExe1 Lock front panel adjustments;
adjust via RS-232 only. Only input
selection and volume adjustment
are available via the front panel.
View the executive mode status.XExe X7 Show executive mode status.
Example:XExe0
Firmware version, part number & information requests
Query firmware version number.QVer
Request the part number.NN60-386-0XShow the MLS’s part #.
Request general info.I(see below)Show the MLS’s status.
X11
Show the switcher’s firmware
version.
X1X1X7
Video input # X1
is selected/active.
Vid • Aud • Clp
Audio input
# X1 is
selected/active.
Audio clipping
status.
Zap (reset to default settings)
Zap all MLS settings/memories.
Zap the audio settings. zAZapA Reset the audio settings and
Esc
zXXXZapXXX Reset everything (all settings
and adjustments) to the factory
default.
adjustments to the factory
default.
4-5MediaLink Switchers • Serial Communication
Serial Communication, cont’d
The syntax for setting a special function is __ * X? # where __ is the function number and X? is the value.
To view a function’s setting, use __#, where __ is the function number. In the following table the values of
the X? variable are different for each command/function. These values are given in the rightmost column.
Command/response table for special function SIS commands
CommandASCII Command Response
(host to switcher)(switcher to host)and additional descriptions
X?
values
Delay times
Set the RGB delay (Triple-Action Switching). 3 * X? #RGBDly* X? 0 = 0.0 seconds (default), 1 = 0.5
seconds, 2 = 1.0 seconds,
... in ½ second steps up to
10 = 5.0 seconds
Example: 3*7#RGBDly*07Example: 3.5 second RGB delay.
Audio settings
Set the preamp output mode.18 * X? #PreAmpMod* X? Set the Audio Out (fixed and
If mono is selected, the audio signal will
be the same on both the left and right
channels. If stereo is selected, the
switcher will send out different (stereo)
signals on the left and right channels.
Enable/disable the Effects Return.19 * X? #EffectIn* X? This setting of for the
• If the Effects setting is disabled, the
Effects Send connector still outputs an
audio signal, but the Effects Return
connector will be internally disabled so
any audio signal present there will not
reach the Audio Out or amplified output
connectors.
• If the Effects setting is enabled, any
audio signal input via the Effects Return
connector will be output via the Audio
Out connector and the amplified output
(if applicable).
variable) connectors’ output to
be either mono or stereo signals.
1 = mono
2 = stereo (default)
Set the left-right audio balance.22 * X? #Balance* X? Set the attenuation applied to
the left and right audio
channels.
0 = attenuate the left audio
channel 100% (mute the left,
scroll bar is at the right)
...
20 = 0dB attenuation for both
channels
...
40 = attenuate the right channel
100% (mute the right, scroll bar
is at the left)
Select the stereo output speaker load 23 * X? #SpkrLoad*X? Tell the MLS 506SA the total
(MLS 506SA only)
impedance of speakers that are
attached to the stereo amplified
output.
1 = 4 ohm total load (default)
2 = 8 ohm total load
MediaLink Switchers • Serial Communication4-6
Control Software for Windows
The included Extron MediaLink Control Program for Windows offers another way
to control the Switcher via RS-232 connection in addition to the Simple Instruction
Set commands. The control program’s graphical interface includes the same
functions as those on the switcher’s front panel and some additional features that
are only available through the Windows-based software.
The control software is compatible with Windows 95/98, Windows NT, and
Windows 2000. Extron’s MediaLink Control Program is included with the MLS,
and updates can be downloaded from the Extron Web site
(http://www.extron.com).
Installing the software
The control program is contained on a set of 3.5-inch diskettes, and it requires
approximately 2 MB (megabytes) of hard disk space.
To install the software on the hard drive:
1.Run SETUP.EXE from the floppy disk.
2.Follow the instructions that appear on the screen.
By default the installation creates a C:\MediaLnk directory, and it places two icons
(MediaLnk Control Pgm and MediaLnk Help) into a group or folder named
“Extron Electronics”.
Using the control program
Many items found in the MediaLink Control Program are also accessible via front
panel controls and the LCD menus described in chapter three. Refer to that chapter
for details on features and settings. The MediaLink Help Program provides
information on settings and on how to use the control program itself. Some
features are only available via this control program. These features are described in
the sections of this chapter that correspond to the parts of the control program
where the features are found.
1.To run the control program, double-click on the MediaLnk Control Pgm icon
in the Extron Electronics group or folder. The Comm menu
appears on the screen.
2.Click on the comm port that is connected to the MLS’s RS-232 port.
The Extron MediaLink Control Program windows appear. The port and
firmware information are displayed at the bottom of the screen. There are
two views available: the User Mode screen,and the Switcher (MLS)Configuration screen.
4-7MediaLink Switchers • Serial Communication
Serial Communication, cont’d
User Mode
The User Mode screen, shown below, includes the most frequently used controls: it
emulates the front panel for basic functions (input selection, volume control). See
chapter two of this manual for details on basic functions.
operation.
Special features
Audio/video breakaway switching — To switch the audio signal separately from
the video signal, check the Audio checkbox (at the right side of the I/O
Switching area) and uncheck Video checkbox, then select an input. The MLS
switches to that input’s audio source while leaving the previously selected
video source active. Alternatively, you can select the Mixer button to switch
to the Mix input’s audio. The picture above shows audio breakaway: video is
from input 3 and audio from input 4.
To switch the video signal without changing the audio source, check the
Video check box and uncheck the Audio checkbox.
Selecting Mute selects input 0 (no input).
Volume Mute — Check this box (in the lower left corner) to activate the audio mute
(Amt) command.
Disable Switcher Front Panel — This feature (shown activated in the picture
above) toggles the executive mode on or off to prevent or enable making
configuration (menu-based) changes via the MLS’s front panel.
MediaLink Switchers • Serial Communication4-8
Switcher (MLS) Config
The Switcher (MLS) Config screen, shown below, allows you to make adjustments
without having to use the front panel controls.
In this part of the program you can:
• Set per-input audio adjustments (level, bass, treble).
• Set overall volume.
• Set the left-right audio balance.
• Set the mixer volume (MLS 506MA & MLS 506SA only).
• Choose between stereo and mono output for the variable preamp output.
• Tell the MLS 506SA whether a 4 ohm or an 8 ohm total load is connected to the
stereo amplified output.
• Set the video format (composite video/S-video, or component video) for inputs 1
through 3 on an MLS 506, MLS 506MA, or MLS 506SA.
• Set the RGB delay period (for Triple-Action Switching).
• Reset the switcher to factory default settings.
Saving and restoring configurations
The MLS can be configured by various means (front panel adjustments,
downloading settings, or combinations of those methods), and the configuration
settings can be saved to a file for later use.
1.In the MediaLink Control Program, select File, then select Save Configuration
as... .
2.Save the file as (filename).MLK. An unlimited number of configuration files
can be saved as long as each file has a unique file name ending in .MLK.
3.To retrieve the configuration from within the MediaLink Control Program,
select File, then select Restore Configuration from... . A set of all the switcher
and audio adjustment settings will be downloaded into the MLS.
4-9MediaLink Switchers • Serial Communication
Serial Communication, cont’d
Using the help program
For information on program features, press the F1 computer key, or click on the
Help menu from within the MediaLink control program, or
double-click on the MediaLnk Help icon in the Extron Electronics
group or folder.
For explanations of buttons or functions, click on the tabs in the help screen to
reach the desired screen. Use a mouse or the Tab and Enter keys to select a button/
function. A description and tips on using the program will appear on screen.
Key to file names
File nameDescription
________.MLKUser-saved MLC/MLC-MLS/MLS configuration file. This
includes adjustments/settings. If the MLS is connected to an
MLC 206 MediaLink Controller, the file will also contain
whatever driver (if any) was installed in the MLC 206 at the time
the file was saved. See the MLC 206 User’s Manual for details.
MediaLink Switchers • Serial Communication4-10
MediaLink Switchers
Appendix A
A
Specifications, Part Numbers,
and Dimensions
Specifications
Part Numbers and Accessories
Dimensions
Specifications, Part Numbers, and Accessories
Specifications
Video
Gain ............................................... Unity
A-5MediaLink Switchers • Specifications, Part Numbers, and Accessories
Specifications, Part Numbers, and Accessories, cont’d
MediaLink Switchers • Specifications, Part Numbers, and AccessoriesA-6
MediaLink Switchers
Appendix B
B
Labeling
Labeling Buttons on the Switcher
Button-Label Generator Software
Label Templates
Labeling
Labeling Buttons on the Switcher
Button-Label Generator Software
The MLS switchers have translucent panels (“windows”) behind which customized
labels can be inserted. To remove a panel,
1.Insert the head of a small Phillips screwdriver into the hole in one end of the
panel.
2.Gently slide the tab on the edge of the panel out of the recess in the MLS’s
faceplate.
Premade templates and blank templates for the MLSs’ label windows are printed in
this chapter. However, you can easily create, customize, and print labels by using
the Button-Label Generator software or any Brother P-Touch labeler.
The Extron Button-Label Generator program (Buttons.exe) is shipped with the MLS
switchers, and it is also available on the Extron Web site. This program is used to
create and print labels that can be placed in slot above the input selection buttons
on the MLSs.
The program occupies approximately 0.5 MB of disk space. It can be run on a
diskette from a floppy drive, but it is more convenient to load and run the program
from a hard drive.
Installing the software
This program is installed at the same time and from the same diskettes as the
MediaLink control program. See chapter four for details. The Button-Label
Generator program can be installed separately via the Download page of the Extron
Web site (http://www.extron.com). Follow the on-screen directions if you install
the program from the Web site.
By default, the Windows installation creates a C:\BUTTONS directory, and it will
place an icon (Button-Label Generator) into a group or folder named “Extron
Electronics”.
Using the software to make labels
1.To run the Button-Label Generator program, double-click on the Button-Label
Generator icon (shown at left) in the Extron Electronics group or
folder, and click OK when prompted.
2.Under System selection, choose SCP 200. The button label editing area changes
to reflect the number and arrangement of buttons on the device. Choosing
the SCP 200 will allow you to create two label rows of six buttons each.
3.Using normal Windows controls, you can create and print labels for the front
panels of the MLS switchers.
4.Cut the label strips to the appropriate length, and install them in the MLS’s
windows.
For information about using the program, you can access a help file by clicking on
the Help menu on the main screen and choosing Show Help.
You can also see an example of a completed Button-Label Generator window by
clicking on the Help menu on the main screen, choosing Show Help, and clicking on
the Load Demo button.
The following picture shows how the Button-Label Generator screen looks when
set for the SCP 200.
MediaLink Switchers • LabelingB-2
SCP 200 button label screen
Label Templates
Below are full-sized templates for the labels. Feel free to photocopy them, write
button information in each area of the blank templates as desired, cut the strips out,
and insert the strips in the label window.
Each input, display, and room
control can be labeled with
names, alphanumeric characters, or bitmapped pictures.
Each button’s label can contain
from 1 to 3 lines of text (or none).
Each line provides a choice of
font sizes and text placement.
Pictures can be selected either
from the Device Palette or a
user-supplied graphic file.
User-supplied graphics should
be icon (.ICO) or bitmap (.BMP)
files. Files called TEST.BMP and
DEMO_BTN.DAT are installed
with this program as examples.
DISPLAY
POWER
DISPLAY
POWER
DISPLAY
MUTE
DISPLAY
MUTE
MODEROOM 1 ROOM 2
MODEROOM 1 ROOM 2
1
1
234567
123456
B-3MediaLink Switchers • Labeling
Labeling, cont’d
This page is left blank intentionally.
MediaLink Switchers • LabelingB-4
FCC Class A Notice
Note: This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause harmful interference to
radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference, in which case the user will be required to correct the interference at his own expense.
Note: This unit was tested with shielded cables on the peripheral devices. Shielded cables must be
used with the unit to ensure compliance.
Extron’s Warranty
Extron Electronics warrants this product against defects in materials and workmanship for a period
of three years from the date of purchase. In the event of malfunction during the warranty period
attributable directly to faulty workmanship and/or materials, Extron Electronics will, at its option,
repair or replace said products or components, to whatever extent it shall deem necessary to restore
said product to proper operating condition, provided that it is returned within the warranty period,
with proof of purchase and description of malfunction to:
USA, Canada, South America,Europe, Africa, and the Middle East:
and Central America:
Extron ElectronicsBeeldschermweg 6C
1230 South Lewis Street3821 AH Amersfoort
Anaheim, CA 92805, USAThe Netherlands
Extron Electronics, Europe
Asia:Japan:
Extron Electronics, Japan
Extron Electronics, AsiaDaisan DMJ Bldg. 6F,
135 Joo Seng Road, #04-013-9-1 Kudan Minami
PM Industrial Bldg.Chiyoda-ku, Tokyo 102-0074
Singapore 368363Japan
This Limited Warranty does not apply if the fault has been caused by misuse, improper handling
care, electrical or mechanical abuse, abnormal operating conditions or non-Extron authorized
modification to the product.
If it has been determined that the product is defective, please call Extron and ask for an Applications
Engineer at (714) 491-1500 (USA), 31.33.453.4040 (Europe), 65.383.4400 (Asia), or 81.3.3511.7655 (Japan)
to receive an RA# (Return Authorization number). This will begin the repair process as quickly as
possible.
Units must be returned insured, with shipping charges prepaid. If not insured, you assume the risk
of loss or damage during shipment. Returned units must include the serial number and a
description of the problem, as well as the name of the person to contact in case there are any
questions.
Extron Electronics makes no further warranties either expressed or implied with respect to the
product and its quality, performance, merchantability, or fitness for any particular use. In no event
will Extron Electronics be liable for direct, indirect, or consequential damages resulting from any
defect in this product even if Extron Electronics has been advised of such damage.
Please note that laws vary from state to state and country to country, and that some provisions of
this warranty may not apply to you.
Extron Electronics, USA
1230 South Lewis Street
Anaheim, CA 92805
USA
www.extron.com
714.491.1500
Fax 714.491.1517
Extron Electronics, Europe
Beeldschermweg 6C
3821 AH Amersfoort
The Netherlands
+31.33.453.4040
Fax +31.33.453.4050
Extron Electronics, Asia
135 Joo Seng Road, #04-01
PM Industrial Building
Singapore 368363
+65.383.4400
Fax +65.383.4664