135 Joo Seng Road, #04-01
PM Industrial Building
Singapore 368363
+65.6383.4400
ax +65.6383.4664
F
Extron Electronics, Japan
Kyodo Building
16 Ichibancho
Chiyoda-ku, Tokyo 102-0082 Japan
+81.3.3511.7655
Fax +81.3.3511.7656
MLS 100 A, MLS 102 VGA,
MLS 103 V, MLS 103 SV
MediaLink™ VersaTools® Switchers
68-652-01 Rev. C
05 05
Precautions
Safety Instructions • English
This symbol is intended to alert the user of important
operating and maintenance (servicing) instructions
in the literature provided with the equipment.
This symbol is intended to alert the user of the
presence of uninsulated dangerous voltage within
the product's enclosure that may present a risk of
electric shock.
Caution
ReadInstructions • Read and understand all safety and operating
instructions before using the equipment.
Retain Instructions • The safety instructions should be kept for future
reference.
Follow Warnings • Follow all warnings and instructions marked on the
equipment or in the user information.
Avoid Attachments • Do not use tools or attachments that are not
recommended by the equipment manufacturer because they may be
hazardous.
Consignes de Sécurité • Français
Ce symbole sert à avertir l’utilisateur que la
documentation fournie avec le matériel contient des
instructions importantes concernant l’exploitation
et la maintenance (réparation).
Ce symbole sert à avertir l’utilisateur de la présence
dans le boîtier de l’appareil de tensions dangereuses
non isolées posant des risques d’électrocution.
Attention
Lire les instructions• Prendre connaissance de toutes les consignes de
sécurité et d’exploitation avant d’utiliser le matériel.
Conserver les instructions• Ranger les consignes de sécurité afin de
pouvoir les consulter à l’avenir.
Respecter les avertissements • Observer tous les avertissements et
consignes marqués sur le matériel ou présentés dans la documentation
utilisateur.
Eviter les pièces de fixation • Ne pas utiliser de pièces de fixation ni
d’outils non recommandés par le fabricant du matériel car cela
risquerait de poser certains dangers.
Sicherheitsanleitungen • Deutsch
Dieses Symbol soll dem Benutzer in der im
Lieferumfang enthaltenen Dokumentation
besonders wichtige Hinweise zur Bedienung und
Wartung (Instandhaltung) geben.
Dieses Symbol soll den Benutzer darauf aufmerksam
machen, daß im Inneren des Gehäuses dieses
Produktes gefährliche Spannungen, die nicht isoliert
sind und die einen elektrischen Schock verursachen
können, herrschen.
Achtung
Lesen der Anleitungen • Bevor Sie das Gerät zum ersten Mal verwenden,
sollten Sie alle Sicherheits-und Bedienungsanleitungen genau
durchlesen und verstehen.
Aufbewahren der Anleitungen • Die Hinweise zur elektrischen Sicherheit
des Produktes sollten Sie aufbewahren, damit Sie im Bedarfsfall darauf
zurückgreifen können.
Befolgen der Warnhinweise • Befolgen Sie alle Warnhinweise und
Anleitungen auf dem Gerät oder in der Benutzerdokumentation.
Keine Zusatzgeräte • Verwenden Sie keine Werkzeuge oder Zusatzgeräte,
die nicht ausdrücklich vom Hersteller empfohlen wurden, da diese eine
Gefahrenquelle darstellen können.
Instrucciones de seguridad • Español
Este símbolo se utiliza para advertir al usuario sobre
instrucciones importantes de operación y
mantenimiento (o cambio de partes) que se desean
destacar en el contenido de la documentación
suministrada con los equipos.
Este símbolo se utiliza para advertir al usuario sobre
la presencia de elementos con voltaje peligroso sin
protección aislante, que puedan encontrarse dentro
de la caja o alojamiento del producto, y que puedan
representar riesgo de electrocución.
Precaucion
Leer las instrucciones • Leer y analizar todas las instrucciones de
operación y seguridad, antes de usar el equipo.
Conservar las instrucciones • Conservar las instrucciones de seguridad
para futura consulta.
Obedecer las advertencias • Todas las advertencias e instrucciones
marcadas en el equipo o en la documentación del usuario, deben ser
obedecidas.
Evitar el uso de accesorios • No usar herramientas o accesorios que no
sean especificamente recomendados por el fabricante, ya que podrian
implicar riesgos.
Warning
Power sources • This equipment should be operated only from the power source
indicated on the product. This equipment is intended to be used with a main
power system with a grounded (neutral) conductor. The third (grounding) pin is
a safety feature, do not attempt to bypass or disable it.
Power disconnection • To remove power from the equipment safely, remove all
power cords from the rear of the equipment, or the desktop power module (if
detachable), or from the power source receptacle (wall plug).
Power cord protection • Power cords should be routed so that they are not likely to
be stepped on or pinched by items placed upon or against them.
Servicing • Refer all servicing to qualified service personnel. There are no user-
serviceable parts inside. To prevent the risk of shock, do not attempt to service
this equipment yourself because opening or removing covers may expose you to
dangerous voltage or other hazards.
Slots and openings • If the equipment has slots or holes in the enclosure, these are
provided to prevent overheating of sensitive components inside. These openings
must never be blocked by other objects.
Lithium battery • There is a danger of explosion if battery is incorrectly replaced.
Replace it only with the same or equivalent type recommended by the
manufacturer. Dispose of used batteries according to the manufacturer's
instructions.
Avertissement
Alimentations• Ne faire fonctionner ce matériel qu’avec la source d’alimentation
indiquée sur l’appareil. Ce matériel doit être utilisé avec une alimentation
principale comportant un fil de terre (neutre). Le troisième contact (de mise à la
terre) constitue un dispositif de sécurité : n’essayez pas de la contourner ni de la
désactiver.
Déconnexion de l’alimentation• Pour mettre le matériel hors tension sans danger,
déconnectez tous les cordons d’alimentation de l’arrière de l’appareil ou du
module d’alimentation de bureau (s’il est amovible) ou encore de la prise secteur.
Protection du cordon d’alimentation • Acheminer les cordons d’alimentation de
manière à ce que personne ne risque de marcher dessus et à ce qu’ils ne soient
pas écrasés ou pincés par des objets.
Réparation-maintenance • Faire exécuter toutes les interventions de réparation-
maintenance par un technicien qualifié. Aucun des éléments internes ne peut être
réparé par l’utilisateur. Afin d’éviter tout danger d’électrocution, l’utilisateur ne
doit pas essayer de procéder lui-même à ces opérations car l’ouverture ou le
retrait des couvercles risquent de l’exposer à de hautes tensions et autres dangers.
Fentes et orifices • Si le boîtier de l’appareil comporte des fentes ou des orifices,
ceux-ci servent à empêcher les composants internes sensibles de surchauffer. Ces
ouvertures ne doivent jamais être bloquées par des objets.
Lithium Batterie • Il a danger d'explosion s'll y a remplacment incorrect de la
batterie. Remplacer uniquement avec une batterie du meme type ou d'un ype
equivalent recommande par le constructeur. Mettre au reut les batteries usagees
conformement aux instructions du fabricant.
Vorsicht
Stromquellen • Dieses Gerät sollte nur über die auf dem Produkt angegebene
Stromquelle betrieben werden. Dieses Gerät wurde für eine Verwendung mit
einer Hauptstromleitung mit einem geerdeten (neutralen) Leiter konzipiert. Der
dritte Kontakt ist für einen Erdanschluß, und stellt eine Sicherheitsfunktion dar.
Diese sollte nicht umgangen oder außer Betrieb gesetzt werden.
Stromunterbrechung • Um das Gerät auf sichere Weise vom Netz zu trennen,
sollten Sie alle Netzkabel aus der Rückseite des Gerätes, aus der externen
Stomversorgung (falls dies möglich ist) oder aus der Wandsteckdose ziehen.
Schutz des Netzkabels • Netzkabel sollten stets so verlegt werden, daß sie nicht
im Weg liegen und niemand darauf treten kann oder Objekte darauf- oder
unmittelbar dagegengestellt werden können.
Wartung • Alle Wartungsmaßnahmen sollten nur von qualifiziertem
Servicepersonal durchgeführt werden. Die internen Komponenten des Gerätes
sind wartungsfrei. Zur Vermeidung eines elektrischen Schocks versuchen Sie in
keinem Fall, dieses Gerät selbst öffnen, da beim Entfernen der Abdeckungen die
Gefahr eines elektrischen Schlags und/oder andere Gefahren bestehen.
Schlitze und Öffnungen • Wenn das Gerät Schlitze oder Löcher im Gehäuse
aufweist, dienen diese zur Vermeidung einer Überhitzung der empfindlichen
Teile im Inneren. Diese Öffnungen dürfen niemals von anderen Objekten
blockiert werden.
Litium-Batterie • Explosionsgefahr, falls die Batterie nicht richtig ersetzt wird.
Ersetzen Sie verbrauchte Batterien nur durch den gleichen oder einen
vergleichbaren Batterietyp, der auch vom Hersteller empfohlen wird. Entsorgen
Sie verbrauchte Batterien bitte gemäß den Herstelleranweisungen.
Advertencia
Alimentación eléctrica • Este equipo debe conectarse únicamente a la fuente/tipo
de alimentación eléctrica indicada en el mismo. La alimentación eléctrica de este
equipo debe provenir de un sistema de distribución general con conductor
neutro a tierra. La tercera pata (puesta a tierra) es una medida de seguridad, no
puentearia ni eliminaria.
Desconexión de alimentación eléctrica • Para desconectar con seguridad la
acometida de alimentación eléctrica al equipo, desenchufar todos los cables de
alimentación en el panel trasero del equipo, o desenchufar el módulo de
alimentación (si fuera independiente), o desenchufar el cable del receptáculo de
la pared.
Protección del cables de alimentación • Los cables de alimentación eléctrica se
deben instalar en lugares donde no sean pisados ni apretados por objetos que se
puedan apoyar sobre ellos.
Reparaciones/mantenimiento • Solicitar siempre los servicios técnicos de personal
calificado. En el interior no hay partes a las que el usuario deba acceder. Para
evitar riesgo de electrocución, no intentar personalmente la reparación/
mantenimiento de este equipo, ya que al abrir o extraer las tapas puede quedar
expuesto a voltajes peligrosos u otros riesgos.
Ranuras y aberturas • Si el equipo posee ranuras o orificios en su caja/alojamiento,
es para evitar el sobrecalientamiento de componentes internos sensibles. Estas
aberturas nunca se deben obstruir con otros objetos.
Batería de litio • Existe riesgo de explosión si esta batería se coloca en la posición
incorrecta. Cambiar esta batería únicamente con el mismo tipo (o su equivalente)
recomendado por el fabricante. Desachar las baterías usadas siguiendo las
instrucciones del fabricante.
FCC Class A Notice
Note: This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful
interference, in which case the user will be required to correct the interference at his
own expense.
Note: This unit was tested with shielded cables on the peripheral devices. Shielded
cables must be used with the unit to ensure compliance.
Extron’s Warranty
Extron Electronics warrants this product against defects in materials and
workmanship for a period of three years from the date of purchase. In the event of
malfunction during the warranty period attributable directly to faulty workmanship
and/or materials, Extron Electronics will, at its option, repair or replace said products
or components, to whatever extent it shall deem necessary to restore said product to
proper operating condition, provided that it is returned within the warranty period,
with proof of purchase and description of malfunction to:
USA, Canada, South America,Europe, Africa, and the Middle East:
and Central America:
Extron ElectronicsBeeldschermweg 6C
1001 East Ball Road
Anaheim, CA 92805, USAThe Netherlands
Asia:Japan:
Extron Electronics, AsiaExtron Electronics, Japan
135 Joo Seng Road, #04-01Kyodo Building
PM Industrial Bldg.16 Ichibancho
Singapore 368363Chiyoda-ku, Tokyo 102-0082
This Limited Warranty does not apply if the fault has been caused by misuse,
improper handling care, electrical or mechanical abuse, abnormal operating conditions
or non-Extron authorized modification to the product.
If it has been determined that the product is defective, please call Extron and ask for
an Applications Engineer at (714) 491-1500 (USA), 31.33.453.4040 (Europe),
65.6383.4400 (Asia), or 81.3.3511.7655 (Japan) to receive an RA# (Return Authorization
number). This will begin the repair process as quickly as possible.
Units must be returned insured, with shipping charges prepaid. If not insured, you
assume the risk of loss or damage during shipment. Returned units must include the
serial number and a description of the problem, as well as the name of the person to
contact in case there are any questions.
Extron Electronics makes no further warranties either expressed or implied with
respect to the product and its quality, performance, merchantability, or fitness for any
particular use. In no event will Extron Electronics be liable for direct, indirect, or
consequential damages resulting from any defect in this product even if Extron
Electronics has been advised of such damage.
Please note that laws vary from state to state and country to country, and that some
provisions of this warranty may not apply to you.
Extron Electronics, Europe
3821 AH Amersfoort
Japan
Quick Start Guide — MLS 100 Series
To install and set up the MLS 100 Series switchers, follow these steps
and see the appropriate section of this manual for details:
Step 1
Turn all of the equipment off and disconnect the power cords.
Step 2
Mount the switcher (if applicable) or affix the rubber feet to the
bottom of the switcher for tabletop use. See page 2-2.
Step 3
Attach the cables. See the instructions beginning on page 2-5.
Laptop
Projector
NOTE Ground all devices. If you use
cable that has a drain wire, tie the
drain wire to ground at both ends.
To connect a computer or control
system, see page 2-8.
DEABCABD
RS-232
1A 1B 2A 2B 3A 3B
Relays IR/ RCM
IR
Balanced/
Unbalanced
Output
External
Power Supply
MLS 102 VGA
MLS 102 VGA
VCR
Wireless
Microphone's
Receiver
INPUTS
AUDIO INPUTS
2
3
LR
LR
Unbalanced,
Stereo Input
2
4
1
1
Balanced/Unbalanced,
Mono Aux. Input
AUX/MIX
MONO
PREAMP
LR
12V .5A MAX
OUTPUT
CONTROL/
POWER
A
B
ABCDE ABC
Display/Source Control
Amplifier
For the Aux/Mix Mono audio input, connect a 3.5 mm,
3-pole captive screw connector to one end of an audio
cable as shown at right. This line level input can be
balanced or unbalanced. Wire the other end to one
tip-ring-sleeve connector.
The Aux/Mix level must be adjusted
(-43 dB to +24 dB) via the front
panel control. It
To connect an MLC 206 or a control system, see the diagram below,
CONTROL
POWER
AB
/
MLS 100 Series
Switcher
Control/Power
Port
+12 VDC input
Ground ( )
+12 VDC
Ground ( )
Receive (Rx)
B
A
Transmit (Tx)
Step 4
Connect power cords and turn the equipment on.
and see page 2-8 for details.
NOTE
You must connect a ground wire
between the MLC and MLS.
External
Power Supply
(12 VDC, 1A max.)
Transmit (Tx)
Receive (Rx)
B
A
NOTE If you use cable that
has a drain wire, tie
the drain wire to
ground at both ends.
AB
MLS / Power
Step 5
Test the system: select an input from the front panel buttons or via
the control software; observe the display and listen to
the audio output. If you use the MediaLink™ Control
Software, set the volume control in the Controller (MLC)Config section to “Switcher”, as shown at right. Make
any needed cabling corrections.
To avoid damage to your hearing, the Aux/Mix
input and the selectable audio inputs’ levels
and output volume should be set as low as
possible before you test the sound system.
Step 6
Adjust the Aux/Mix level: turn the front panel potentiometer while
listening to the audio
output. See page 3-3.
Step 7
Set up the switcher. In
the Switcher (MLS)Config part of the
MediaLink Control
Software, set the perinput audio adjustments, RGB delay
period (MLS 102 VGA),
and the output volume.
See pages 4-8 to 4-10.
This manual contains information about the Extron MLS 100
Series Switchers (MLS 100 A, MLS 103 V, MLS 103 SV,
MLS 102 VGA) and on how to install, set up, and operate them.
The terms “MLS 100 Series switcher”, “MLS”, and “switcher”
are used interchangeably in this manual.
About the MLS 100 Series Switchers
The Extron MLS 100 Series Switchers are compact, quarter rack
width switchers. The MLS 102 VGA, MLS 103 SV, and
MLS 103 V have a 250 MHz (-3 dB) video bandwidth. The
MLS 102 VGA, MLS 103 SV, and MLS 103 V provide a way to
switch up to three video input signals (up to two for the VGA
model) to one output.
All models (MLS 102 VGA, MLS 103 SV, MLS 103 V, MLS 100 A)
feature four selectable audio inputs, and also one Aux/Mix
input that is always active and can be mixed with any and all of
the four selectable audio inputs.
Front panel buttons, an RS-232-based control system, or an
Extron MediaLink
selection.
Features
Furniture, rack, and projector mountability — MLS 100 Series
Switchers can be mounted under a desk or other
furniture, or mounted on a projector lift with optional
brackets. Alternatively, they can be rack mounted on an
optional rack shelf.
Stereo audio input and output — Unbalanced stereo audio
inputs can be output as balanced or unbalanced stereo
audio, and the audio output level can be adjusted.
Mono auxiliary/mix audio input — The Aux/Mix port on each
switcher lets you mix a mono, line level audio input
signal with that of one of the four selectable stereo audio
inputs.
The Underwriters Laboratories (UL) requirements listed below
pertain to the safe installation and operation of the switcher.
1.This unit is not to be connected to a centralized DC power
source or used beyond its rated voltage range.
The Extron P/S 100 and other Extron power supplies
may be used with the MLS.
2.Do not use the switcher near water.
To reduce the risk of fire or electric shock, do not
expose this apparatus to rain or moisture.
3.Clean the switcher only with a dry cloth.
4.Do not install the switcher near any heat source, such as a
radiator, heat register, stove, or another apparatus
(including amplifiers) that produces heat.
5.Unplug the switcher during lightning storms or when it
will be unused for long periods.
6.This unit must be installed in accordance with the
National Electrical Code.
Mounting the Switchers
The one rack unit high, quarter rack width switchers can be set
on a table, mounted on a rack shelf, mounted under a desk or
tabletop, or mounted on a projector bracket.
Mounting the MLS on a VersaTools rack shelf
Only products in the VersaTools line can be mounted to a
VersaTools shelf. Most 1U rack-mountable Extron
products can be mounted on the standard shelf.
Each MLS switcher comes with rubber feet. For tabletop use,
attach a self-adhesive rubber foot to each corner of the bottom of
the unit.
For optional rack mounting, do not install the rubber feet.
Mount the MLS on a VersaTools® 19" 1U Rack Shelf (Extron
part #60-190-20) or a standard Universal 1U Rack Shelf (Extron
part #60-190-01). On the standard rack shelf, the MLS mounts in
one of four locations to the rear of the rack or in one of four
locations to the front of the rack.
1.If rubber feet were previously installed on the bottom of
the MLS, remove them.
2.Mount the MLS on the rack shelf, using two 4-40 x 1/8
screws in opposite (diagonal) corners to secure the MLS
switcher to the shelf.
Mounting the MLS on a 1U standard rack shelf
3.Install blank panel(s) or other unit(s) to the rack shelf.
The stereo audio inputs 1–3 (7 and 8 on page 2-5 and below)
correspond to video inputs 1, 2, and 3. All four audio inputs can
be selected via the front panel buttons, RS-232 control
(including MLC), or the MediaLink Control Software. An audio
signal from one of these inputs is output only when the
corresponding input is selected. Using the MediaLink Control
Software you can separately adjust the level of each of these
audio inputs.
Via RS-232 control, audio input signals can also be switched
separately from the video signals (a feature called “audio
breakaway”). See pages 4-4 and 4-8.
Computer audio inputs (MLS 102 VGA only) — These inputs
7
each accept unbalanced stereo audio input via a 3.5 mm stereo
Tip (+)Sleeve (Gnd)
Ring (R, -)
Tip (L, +)
Sleeve (Gnd)
Audio Inputs (all models) — Each of these 3-pole, 3.5 mm
8
captive screw
connectors accepts one
unbalanced stereo or
mono audio input.
Wire each captive screw
connector as
shown at right,
depending on the
input type.
Left (+)
Gnd (Sleeve, )
Audio Input Wiring
(unbalanced, mono)
Connect two RCA-style (tip-ring)
connectors to the other end of each audio
input cable as shown at right:
Aux/Mix Mono audio input (all models) —
9
The Aux/Mix Mono audio channel is
always active: its signal is output no matter which, if any, other
audio input (input 1, 2, 3, or 4) is selected. For example, you
could connect the output of a wireless microphone receiver to
mini receptacle (tip-ringsleeve type). If you do
not have a preterminated audio cable,
wire the mini jack on
each end of the cable as
shown at left.
LR
Gnd (Sleeve, )
Right (+)
Audio Input Wiring
(unbalanced, stereo
Tip (+) Sleeve (Gnd)
Left (+)
LR
this port so the presenter’s comments can always be heard and
are independent of the A/V source used for the presentation.
The mix output level can be adjusted between -43 dB and +24 dB.
The Aux/Mix level must be adjusted
physically via the front panel
control. It cannot be adjusted via
software.
Connect a 3.5 mm, 3-pole captive screw
connector to one end of an audio
cable as shown at right. Wire the
other end to two tip-ring connectors
or one tip-ring-sleeve connector as
shown in 7 and 8, and connect it
between the MLS 100 Series switcher
and the auxiliary audio source.
speakers or another stereo audio device to the MLS via this
5-pole, 3.5 mm captive screw connector. Depending on how the
connector is wired, the audio output can be balanced or
unbalanced stereo audio. Wire the connector as shown below.
Connect the sleeve to ground (Gnd). Connecting
the sleeve to a negative (-) terminal will damage the
audio output circuits.
Later, after all the equipment has been cabled and powered on,
use the MediaLink Control Program or an RS-232 controller to set
the per-input gain/attenuation to match the correct audio output
level for the kind of output (balanced or unbalanced) you need.
See pages 2-9 and 4-10 for details on determining and setting
the gain/attenuation to produce the desired output levels.
If you wire an audio output for balanced output, the MLS
outputs a unity signal (input level = output level).
Wiring an audio output for unbalanced output causes
the audio signal to be attenuated by 6 dB. See pages 2-9
and 2-10 for instructions on adjusting audio gain.
Overall volume control ranges from 0% (90 dB
attenuation) to 100% (0 dB attenuation). Adjustment
increments are 1 dB for steps from 1% to 40% volume.
Adjustments are in 0.5 dB increments from 41% to
100% of full volume.
MLC/RS-232 Power port (all models) — An Extron MediaLink
11
Controller (MLC 206), a computer, or an RS-232 controller
provides remote control of input switching and volume, and
also provides a way to set the switcher’s audio input levels. To
control and/or set up the MLS, connect a cable between this
5-pole, 3.5 mm captive screw connector and an optional
MLC 206, computer, or a RS-232 controller. Also connect an
external 12 VDC power supply here to provide power to the
MLS and to the optional MLC.
Extron Comm-Link cable is recommended for this connection.
If using Comm-Link cable, the switcher and controller can be up
to 250 feet (76.2 m) apart. Wire the captive screw connector for
connection to an MLC 206 or control system as shown below.
•For a stand-alone MLS switcher, connect a cable from the host
computer or a control system to this connector to set up and
remotely control the switcher,
connect a 12 VDC power
supply, and tie all the drain
wires to the same ground.
•For an MLS switcher slavedto an MLC controller, connect a cable from the MLC’s MLS/
Power port and from a 12 VDC power supply, and tie all the
MLC/RS-232
POWER
AB
MLS 100 Series
Switcher
MLC/RS-232
Power Port
+12 VDC input
Ground ( )
drain wires to the same ground.
External
Power Supply
(12 VDC, 1A max.)
Ground all devices
AA
3
AUX/MIX
MONO
4
250 ft
(76.2 m)
max.
OUTPUT
PREAMP
LR
SECTION A–A
CONTROL/
POWER
A
B
12V .5A MAX
Power Supply
Power Supply
Output Cord
1
AUDIO INPUTS
2
1
LR
LR
MLS 103 V
MLS 103 V
Rear Panel
2
INPUTS
3
LR
LR
Once the system has been cabled and set up via the control
software and the front panel Aux/Mix adjustment, the MLC or
a host computer communicating through the MLC can be used
to remotely control the switcher. Refer to chapter 4 of the
MediaLink Controllers User’s Manual and to the MediaLink
Control Program help file for details on configuring an
MLC-MLS system.
An Extron IR Link infrared repeater cannot be used with
the MLS 100 Series Switchers. There is no connection
for that device’s control signals.
The MLC to which the MLS 100 Series switcher is
connected must have MLC firmware version 1.04 or
higher. The control/setup software must be version
2.0 or higher. Use one of the following methods to find
out the version levels of the MLC’s firmware and the
control software.
• Connect the MLC’s RS-232 port to a computer or
RS-232 controller, and send an SIS command of Q (see
chapter 4) to the MLC. The MLC responds with its
firmware version.
• Connect the MLC’s RS-232 port to a computer, start
the MediaLink control software
(see chapter four), and click on
Help to display the software
version, the MLC’s firmware
version, and the MLS’s
firmware version as shown in
the example at right.
If your MLS’s firmware is an earlier version, contact
Extron to obtain updated firmware.
External
Setting Up Optimal Audio Gain
Audio input levels and desired output levels vary depending on
the types of equipment involved. Before setting the MLS’s perinput gain or attenuation, determine the levels of the input and
output equipment. Use the table below as a general guide.
+12 VDC
Ground ( )
Receive (Rx)
B
A
Transmit (Tx)
NOTE If you use cable that has a
drain wire, tie the drain wire
to ground at both ends.
HyperTerminal, a third party controller, or the MediaLink
Control/Configuration Software). The gain and attenuation for
the Aux/Mix input are adjustable only via the switcher’s front
panel. (See page 3-3 for Aux/Mix details.)
Setup via the MediaLink™ Control/Configuration
Software
To avoid damage to your hearing, the output
volume should be set as low as possible before you
test the sound system.
1.Cable and power on all the equipment.
2.Start the MediaLink Control Software (see page 4-7), and
select the Switcher (MLS) Config portion of the program
(the second tab from the left).
3.Select an audio input. See the picture below for an
example.
4.Use the following table to determine the gain or
attenuation. Match the desired level for balanced output
or for unbalanced output, depending on how the output
connector is wired.
Gain and Attenuation Settings for MLS 100 Series Switchers
Desired Output Levels
Balanced
0 dBu
0 dB
+8 dB+12 dB
-10 dBV
(-8 dBu)
0 dB
10 dB+18 dB+22 dB
+4 dBu
+4 dBu0 dB-4 dB -12 dB -22 dB
0 dBu
+4 dB-8 dB -18 dB
-10 dBV
Levels
(-8 dBu)
Input Source
-20 dBV
(-18 dBu)
-20 dBV
(-18 dBu)
-10 dB
0 dB
+4 dBu 0 dBu
+10 dB +6 dB
+18 dB +14 dB
Unbalanced
+6 dB
+2 dB-6 dB-16 dB
-20 dBV
-10 dBV
(-8 dBu)
(-18 dBu)
-2 dB -12 dB
+6 dB
+16 dBn.a.+24 dB
-4 dB
+6 dB
For dBV the reference is 1 volt.
For dBu the reference is 0.775 volts.
5.In the control program, move the Audio Input Level slider
to select the gain/attenuation for that input,
as shown at left.
6.Repeat steps 3–5 for the other three inputs.
7.Test the system by listening to audio output for each input.
Start by setting the audio output to the lowest level.
7a.If the audio output is too loud or is clipping
(becoming distorted as the loudest parts are cut off),
decrease the gain for that input.
7b. If the output is too soft or inaudible, increase the gain.
Input gain and attenuation for audio inputs 1
through 4 is adjustable via RS-232 control only
(using SIS commands or the MediaLink Control/
Configuration Software.)
The Aux/Mix input level can be adjusted via the front
panel Aux/Mix Level control only. Aux/Mix level
can not be adjusted via RS-232 (SIS commands,
configuration software, or an MLC MediaLink
Controller). The Aux/Mix level is independent of the
input and volume controls for the four switchable inputs.
Volume for the four switchable inputs is not
adjustable via the front panel. It can be adjusted only via
RS-232 (including via an MLC).
Wait at least ten (10) seconds between making a change
(input selection or audio adjustment) and disconnecting
power from the MLS. The switcher needs several
seconds to store and save the new settings in its memory.
2-10
If you wire an audio output for balanced output, the
MLS outputs a unity signal (input level = output level).
If you wire an audio output for unbalanced output, it
causes the audio signal to be attenuated by 6 dB (gain =
All the MLS 100 Series switchers share the same front panel
design, shown above.
Input selection buttons and indicator LEDs — Press one of
1
these buttons to select the desired audio and video input. The
corresponding LED lights and remains lit while an audio-video
input is selected. During audio breakaway (selectable only via
RS-232 control, described in chapter 4), audio is switched
separately from video; the selected video input’s LED lights
steadily, and the audio input’s LED blinks.
•The MLS 100 A accepts only audio inputs, so pressing one
of these buttons selects an audio-only input.
•The MLS 103 V and MLS 103 SV offer three video inputs
and four selectable audio inputs. Pressing button 1, 2, or 3
selects audio-video input 1, 2, or 3; pressing button 4
selects audio-only input 4.
•The MLS 102 VGA offers two computer-video inputs and
four selectable audio inputs. Pressing button 1 or button 2
selects audio-video input 1 or 2; pressing button 3 or
button 4 selects an audio-only input (3 or 4).
If you select an audio-only input (input 3 or 4 for MLS 102 VGA,
input 4 for MLS 103 SV and MLS 103 V) via front panel buttons,
the video signal is muted, and the selected audio input’s LED
blinks.
Input 0 can be selected via RS-232 control only by using an SIS
command or by selecting Mute (shown here)
from the User Mode section of the control
program (if the MLS is used without an MLC).
Selecting input 0 mutes the audio from inputs
1 through 4.
For all models the Aux/Mix audio input is always enabled and
cannot be turned on or off from the front panel. The Aux/Mix
AUX/M IX
LEVEL
MediaLink Switcher
21
audio does not change when you switch between the four
selectable audio inputs.
The last selected input (including audio/video breakaway selections) will be the active input when the MLS is powered on.
Wait at least 10 seconds between making a change (input
selection or audio adjustment) and disconnecting power
from the MLS. The switcher needs several seconds to
store the new settings in its memory.
Aux/Mix Level control — This potentiometer controls the
2
auxiliary/mix audio volume. This channel’s audio is always
output, no matter which, if any, other audio input (0, 1, 2, 3, 4) is
selected. Use a small screwdriver to turn this control while you
listen to the audio output. When the control is turned to its
counterclockwise limit (-43 dB), the Aux/Mix signal is
inaudible. You hear the maximum Aux/Mix volume when the
control is turned to the clockwise limit (+24 dB).
Once this level is set, the Aux/Mix level remains the
same no matter which input (1 through 4) is selected,
and the Aux/Mix audio can be heard at that level even if
the selectable audio inputs are muted or if audio input 0
is selected via RS-232 control.
The gain and attenuation for audio inputs 1 through 4
is adjustable only via RS-232 control (using SIS
commands or the MediaLink Control/Configuration
Software.)
The gain and attenuation for the Aux/Mix input is
adjustable only via the Aux/Mix Level control.
Wait at least 10 seconds between making a change (input
selection or audio adjustment) and disconnecting power
from the MLS. The switcher needs several seconds to
store/save the new settings in its memory.
Executive mode — enabling and disabling front
panel buttons
1.To disable front panel input selection (turn executive mode
on), simultaneously press input selection buttons 1 and 4
and hold them down for three seconds. All LEDs light for
about one second.
2.While executive mode is on, input selection can be
performed via RS-232 control or from an optional
MediaLink Controller.
3.To enable front panel input selection (turn executive mode
off), repeat step 1 (pressing and holding buttons 1 and 4).
1.Connect the cables between the MLS and the A/V input
devices. Connect the provided power supply and a host
computer, third party control system, or MediaLink
Controller to the MLS’s MLC/RS-232 Power port.
Connect the MLS to the display device (projector) and
audio output device (tape deck, speakers).
2.Connect the control device (computer, control system, or
MLC 206), the A/V source devices, projector and audio
output device to a power source and turn them on.
3.Start the MediaLink Control Program, and set up the MLS
(and the MLC, if one is used). See chapter 4.
4.Press an input button on the MLS, watch the MLS’s LEDs,
observe the display, and listen to the audio.
4a.If the input selection LED does not light when a
button is pressed, the MLS might not be receiving
power. Check the wiring at the MLS’s MLC/RS-232
Power port.
• If the conductor assignments are not correct, the
• If the wiring is correct, ensure that the power
4b. If power is present at the MLS and at the input and
output devices, but nothing happens (an A/V
switch is not detected) when a button is pressed:
• If a MediaLink Controller is part of the system, the
To set up the MLS 100 Series switcher you must use
MediaLink Control Software version 2.0 or higher.
See the second note on page 2-9. If the software version
is below 2.0, download a new version of the software
from the Extron Web site, www.extron.com.
circuits may be damaged if power is applied to the
wrong pole.
supply has been plugged in to a functional power
source.
MLC’s firmware may be too old. If it is older than
version 1.04, contact Extron for a firmware
upgrade.
The MLC to which the MLS 100 Series switcher is
connected must have MLC firmware version
1.04 or higher. Use one of the following methods
to find out the version levels of the MLC’s
firmware and the control software.
• Connect the MLC’s RS-232 port to a computer
or RS-232 controller, and send an SIS command
of Q to the MLC. The MLC responds with its
firmware version.
• Connect the MLC’s RS-232 port to a computer,
start the MediaLink control software, and click
on Help to display the software version, the
MLC’s firmware version, and the MLS’s
firmware version.
• The audio settings may be too low. Adjust the
Aux/Mix level by turning the Aux/Mix Level
adjustment on the front panel. Adjust each
selectable input’s level by using SIS commands, a
control system, or the Switcher (MLS) Config. part
of the MediaLink Control/Configuration
Software.
• The input or output connectors may not be firmly
attached to the MLS, or they may be miswired.
4c.If power is present, but sound from inputs 1
through 4 isn’t audible, and if changing the audio
volume and gain/attenuation settings does not
resolve the problem, make sure that neither audio
input 0 nor audio mute is selected. Use the SIS
information (I) command or the MediaLink Control/
Configuration Program to determine the audio
settings.
5.Call the Extron S3 Sales and Technical Support Hotline if
the equipment still does not respond when the MLS’s
buttons are pressed.
3-4
MediaLink VersaTools Switchers • Operation
MediaLink VersaTools Switchers • Operation
3-5
Operation, cont’d
This page has been left blank intentionally.
MediaLink™ VersaTools® Switchers
Chapter 4
4
3-6
MediaLink VersaTools Switchers • Operation
Serial Communication
RS-232 Programmer’s Guide
Control/Configuration Software for Windows
®
Serial Communication
The MediaLink switcher can be remotely set up and controlled
via a host computer or other device (such as a control system)
attached to the rear panel MLC/RS-232 Power port.
Alternatively, the switcher can be controlled by an optional
MediaLink Controller (MLC) (connected to the MLS’s
MLC/RS-232 Power port), or by an RS-232 device acting
through the MLC. The control device (host) can use either the
Extron Simple Instruction Set (SIS™) commands or the graphical
control/configuration program for Windows
use and setup of a system that includes a MediaLink Controller,
see the MediaLink Controllers User’s Manual.
MLC
/RS-232
POWER
AB
MLS 100 Series
Switcher
MLC/RS-232
Power Port
+12 VDC
Ground ( )
Receive (Rx)
B
A
Transmit (Tx)
MLC/RS-232 Power port pin assignments
RS-232 Programmer’s Guide
Host-to-MLS communications
SIS commands consist of one or more characters per field. No
special characters are required to begin or end a command
sequence. When the MLS determines that a command is valid,
it executes the command and sends a response to the host
device. All responses from the switcher to the host end with a
carriage return and a line feed (CR/LF = ), which signals the
end of the response character string. A string is one or more
characters.
MLS-initiated messages
When a local event such as a front panel selection or adjustment
takes place, the MLS responds by sending a message to the host.
No response is required from the host. The MLS-initiated
messages are listed here (underlined).
(c)Copyright 2002, Extron Electronics MLS 100 Series, V0.08
The MLS sends the copyright message when it first powers on.
Vx.xx is the firmware version number. The MLS 102 VGA is
used in this example.
X1
Chn
The MLS sends this response when an input is switched.
(where X1 is the input number)
®
. For details on
The switcher protocol is
9600 baud
1 stop bit
no parity
no flow control.
The MLC/RS-232 Power
3.5 mm, 5-pole captive screw
connector’s pin assignments
are shown at left.
Error responses
When the MLS receives a valid SIS command, it executes the
command and sends a response to the host device. If the MLS is
unable to execute the command because the command is invalid
or it contains invalid parameters, it returns an error response to the
host. Error response codes and their descriptions are as follows:
E01 – Invalid input channel number (the number is too large)
E10 – Invalid command
E13 – Invalid value (the number is out of range/too large)
E14 – Invalid for this configuration
Using the command/response tables
The command/response tables on the next page list valid
command ASCII codes, the MLS’s responses to the host, and a
description of the command’s function or the results of
executing the command. Unless otherwise indicated (as for the
gain commands), upper and lower case characters may be used
interchangeably in the command field.
Firmware version, part number & information requests
Request general info.I(see below)Show the MLS’s status.
Zap (reset to default settings)
Zap all MLS settings/memories.
4-5
Serial Communication, cont’d
Command/response table for
special function SIS commands
The syntax for setting a special function is __ * X? # where __ is the
function number and X? is the value.
To view a function’s setting, use
__#, where __ is the function
number. In the table at left the
values of the X? variable are
different for each command/
function. These values are given
in the rightmost column.
values
X?
0 = 0.0 seconds (default), 1 = 0.5
seconds, 2 = 1.0 seconds, ... in
½ second steps up to
10 = 5.0 seconds
Example: 3.5 second RGB delay.
X?
Control/Configuration Software for Windows
The included Extron MediaLink Control/Configuration
Program for Windows offers another way to control the
switcher via RS-232 connection in addition to the Simple
Instruction Set commands. The control program’s graphical
interface includes input selection functions and some additional
features that are available only through the software.
To set up the MLS 100 Series switcher you must use
MediaLink Control/Configuration Software
version 2.0 or higher.
The control software is compatible with Windows 95/98,
Windows NT, and Windows 2000. Extron’s MediaLink Control
Program is included with the MLS, and updates can be
downloaded from the Extron Web site
(http://www.extron.com).
Installing the software
The program is contained on a set of 3.5-inch diskettes; it
requires approximately 2 MB (megabytes) of hard disk space.
To install the software on the hard drive:
1.Run SETUP.EXE from the floppy disk.
2.Follow the instructions that appear on the screen.
By default the installation creates a C:\MediaLnk
directory, and it places two icons (MediaLnk Control Pgm
and MediaLnk Help) into a group or folder named “Extron
Electronics”.
®
4-6
#RGBDly*
X?
(host to switcher)(switcher to host)and additional descriptions
Example: 3*7#RGBDly*07
Command/response table for special function SIS commands
The MediaLink Help Program provides information on settings
and on how to use the control program itself. Some features are
available only via this control program. These features are
described in the sections of this chapter that correspond to the
parts of the control program where the features are found.
1.To run the control program, double-click on the MediaLnk
Control Pgm icon in the Extron Electronics
group or folder. The Comm Port Selection
menu appears on the screen.
2.Click on the comm port that is connected to the MLS’s
RS-232 port. The Extron MediaLink Control/
Configuration Program windows appear. The port and
firmware information are displayed at the bottom of the
screen. There are two views available: the User Mode
screen, and the Switcher (MLS) Configuration screen.
If an MLS 100 Series switcher is used without a MediaLink
Controller, the User Mode screen, shown below, emulates the
MLS’s front panel input selection buttons and also provides a
means of volume control. See page 3-2 for details on basic
operation.
Disable Switcher Front Panel Menus — This feature (near the
bottom of the screen) toggles the executive mode on or off
to prevent or enable making changes (input selections)
via the MLS’s front panel.
For MLS 100 Series switchers controlled by an MLC
If the MLS 100 Series switcher is connected to and controlled by
an MLC, the user mode screen will look something like what is
shown in the picture below.
4-64-64-8
Special features
Audio/video breakaway switching — To switch the audio sig-
nal separately from the video signal, check the Audio
checkbox (at the right side of the I/O Switching area) and
uncheck the Video checkbox, then select an input. The
MLS switches to that input’s audio and leaves the previously selected video source active. Audio breakaway is
shown above: the video is from input 1 and the audio is
from input 2. (The corresponding SIS command is 1&2$.)
To switch the video signal without changing the audio
source, check the Video check box and
uncheck the Audio checkbox. See the
picture at left.
Selecting Mute selects input 0 (no input).
Volume Mute — Check this box (shown at right) in
the lower left corner of the software window to
activate the audio mute (Amt) command. See
page 4-4 for the corresponding SIS command.
In this case, you must set the volume control in
the Controller (MLC) Config sectionto
“Switcher”, as shown at right.
Wait at least 10 seconds between making a change (input
selection or audio adjustment) and disconnecting power
from the MLS. The switcher needs several seconds to
store/save the new settings in its memory.
The Switcher (MLS) Config screen, shown below, allows you to
make adjustments without having to use the front panel
controls.
Wait at least 10 seconds between making a change (input
selection or audio adjustment) and disconnecting power
from the MLS. The switcher needs several seconds to
store the new settings in its memory.
In this part of the program you can:
• Set the per-input audio gain or attenuation.
• Set overall volume; this is the same as the User Mode volume
adjustment.
• Set the RGB delay period (MLS 102 VGA model only).
• Reset the switcher to factory default settings.
3.To retrieve the configuration from within the MediaLink
Control Program, select File, then select Restore
Configuration from... . A set of all the switcher and audio
adjustment settings is downloaded into the MLS.
Emulation mode
The MediaLink Control/Configuration Program features an
emulation mode so you can set up a MediaLink system before
equipment is available on site. In emulation mode a MediaLink
Controller is always included in the system. You select which
MLS switcher and which control modules will be connected to
the MLC. For a stand-alone MLS (without an MLC), connect the
MLS directly to the host computer for setup rather than using
emulation mode.
You can save the emulated settings to a configuration file, then
load that configuration file to the switcher (or switcher and
MLC) when equipment is available.
1.Start the control program by double-
clicking on the MediaLnk Control Pgm
icon in the Extron Electronics group or
folder. The Comm Port Selection
screen (shown at right) appears.
2.Click the Emulate radio button, then
click OK. The Initialize EmulatedMediaLink Configuration from... dialog box appears.
3.Because you will be creating a brand new configuration,
click Cancel instead of selecting a driver file.
Saving and restoring configurations
The MLS can be configured via RS-232 communication, and the
configuration settings can be saved to a file for later use.
1.In the MediaLink Control/Configuration Program, select
File, then select Save Configuration as... .
2.Save the file as filename.MLK. An unlimited number of
configuration files can be saved as long as each file has a
unique file name ending in .MLK.
4.Enter a filename of your choice for storing the configuration
settings, then click Save.
The Emulation Configuration dialog box appears.
This procedure must be performed using a PC on which the
MediaLink Control Software (version 2.4 or higher) has been
installed, and the PC’s RS-232 port must be directly cabled to
the MLS’s MLC/RS-232 Power port.
CAUTION
1.Visit the Extron Web site (
appropriate firmware file for the model of switcher you
want to update. Save the new firmware file, and write
down the filename and location for later use.
2.Connect a cable between the MLC/RS-232 Power port of
the MLS and the serial (RS-232) port of the PC (see chapter
2), and power on the MLS.
3.Start the MediaLink control/configuration program.
4.From the File pull-down menu in the upper left corner,select Update Firmware.
Do not attempt to upload firmware if a MediaLink
Controller (MLC) or other control system is
connected to the MLS switcher. The RS-232 cable
from the PC must be connected directly to the MLS.
Each time you replace existing firmware, the switcher is
reset to the factory default settings.
www.extron.com) to find the
5.Select the MediaLink equipment that will be part of the
6.Select the desired settings in each section of the program.
7.To save the configuration for future use, follow steps 1 and
Updating firmware
If the need arises, you can replace the MLS’s firmware without
opening the unit or changing firmware chips. Follow the
directions on the next page.
system you want to configure, then click on OK. The
Extron MediaLink Control/Configuration Program
window appears.
If you include an MLC in the system, keep in mind that
IR learning cannot be performed in emulation mode.
You must have an MLC connected to the host computer.
2 on page 4-10.
The MediaLink Control Software closes, and a separate
utility program opens and displays a window indicating
the current firmware version.
5.Click Upload. You are prompted to select the firmware
file that you downloaded in step 1. Click OK.
6.When the browser window opens, locate and select the
firmware file, then click Open to upload the firmware into
the MLS.
The firmware update file must have a filename extension
of .s19. If the file does not have that extension, it will
not work properly.
7.Follow the on-screen instructions.
When you recycle power, power off the switcher for at
least four seconds, then restore power.
8.When the firmware uploading is complete, a dialog box
appears and asks you
•to exit the firmware update utility program if the
new firmware loaded correctly (if the correct
firmware version is displayed in the program
window, as shown in the example below)
Using the help program
For information on program features, press the F1 computer
key, or click on the Help menu within the
MediaLink control program, or double-click
on the MediaLnk Help icon in the Extron
Electronics group or folder.
For explanations of buttons or functions, click on the tabs in the
help screen to reach the desired screen. Use a mouse or the Tab
and Enter keys to select a button/function. A description and
tips on using the program appear on screen.
Key to file names
File nameDescription
________.MLK —User-saved MLC/MLC-MLS/MLS
configuration file. This includes adjustments/
settings. If the MLS is connected to an
MLC 206, the file also contains whatever
driver (if any) was installed in the MLC 206 at
the time the file was saved. See the Media-Link Controllers User’s Manual for details.
________.s19 — This is an Extron-supplied firmware update
file. When the firmware is replaced, the
switcher is also automatically reset to factory
default settings.
4-14
or
•to run the utility again (Upload Firmware File, see
step 5) if the firmware didn’t load correctly.
Follow the on-screen directions to complete the process.
Input gain/attenuation for audio inputs 1 – 4 is adjustable via
RS-232 control only (using SIS commands or the MediaLink
Control/Configuration Software.)
The Aux/Mix input level can be adjusted via the front panel Aux/Mix Level control only. Aux/Mix level can not be adjusted via
RS-232 (SIS commands, configuration software, or an MLC
MediaLink Controller). The Aux/Mix level is independent of the
input and volume controls for the four switchable inputs.
Volume for the four switchable inputs is not adjustable via the
front panel. It can be adjusted only via RS-232 (including via an
MLC).