12. Place the lid on the floor box and slide it away from the
hinge to engage the tabs on the box.
13. Reinstall the two previously removed screws, securing the
lid to the box.
13. Replace screws
12. Slide
14. Reconnect power and cables, as necessary.
Optional Extron Architectural Adapter Plates
A variety of optional architectural adapter plates for pass-through
connections may be ordered for the MD floor box AAP bracket.
The AAP bracket can have up to two architectural adapter plates
installed, depending on the configuration selected.
The following configurations of architectural adapter plates could
be installed in the MD floor box adapter plate:
• two single spaced AAPs
• one double spaced AAP
Extron Electronics, USA
1230 South Lewis Street
Anaheim, CA 92805
USA
www.extron.com
714.491.1500
Fax 714.491.1517
Extron Electronics, Europe
Beeldschermweg 6C
3821 AH Amersfoort
The Netherlands
+31.33.453.4040
Fax +31.33.453.4050
© 2002 Extron Electronics. All rights reserved.
Extron Electronics, Asia
135 Joo Seng Road, #04-01
PM Industrial Building
Singapore 368363
+65.6383.4400
Fax +65.6383.4664
Extron Electronics, Japan
Daisan DMJ Building 6F
3-9-1 Kudan Minami
Chiyoda-ku, Tokyo 102-0074 Japan
+81.3.3511.7655
Fax +81.3.3511.7656
MD Floor Box AAP Bracket
Installation
MD Floor Box AAP Bracket Kit
68-720-01 Rev. A
Printed in the USA
09 02
Installation
Introduction
This guide covers installation of the Extron MD Floor Box AAP
Bracket Kit in a Matsushita Denko (MD) floor box. It shows
removal of the old bracket and installation of the new bracket/AAP
unit.
Installation
CAUTION
1. Turn off and disconnect power from all
equipment connected to the floor box.
2. Remove all cables connected to
the portion of the floor box
that is accessible when
the lid is open (if
applicable).
3. Open the lid and
remove the two screws
securing the lid to the
floor box.
4. Remove the lid from
the floor box by sliding
the lid toward the
hinge to disengage it
from the box, then put the
lid aside.
5. Remove the two screws securing the old adapter plate
bracket to the box.
7. Remove the old adapter plate bracket and adapter plate unit
from the floor box.
8. Attach and secure any single or double Extron AAP (for
example, the double AAP shown below) to the MD AAP
bracket with the 4-40 mounting nuts provided.
Installation and service must be performed by
authorized personnel only.
3. Remove screws
9. Connect cables, if applicable, to the back of the AAP to be
installed.
Slide bracket
4. Slide
If an existing adapter plate or blank plate is installed,
complete steps 5 through 7, otherwise skip to step 8.
10. Place the MD AAP bracket into the floor box (as shown
above), routing any cables through the back of the box.
Remove screws
6. Slide the adapter plate bracket to the center of the box and
disconnect the cables attached to the back side of the
adapter plate.
11. Align the two screw holes in the top of the new AAP bracket
with the holes in the box. Attach the bracket with the two
M4 screws provided.
MD Floor Box AAP Kit • InstallationMD Floor Box AAP Kit • Installation
32