12. Place the lid on the floor box and slide it away from the hinge to engage the tabs on the box.
13. Reinstall the two previously removed screws, securing the lid to the box.
13. Replace screws
12. Slide
14. Reconnect power and cables, as necessary.
Optional Extron Architectural Adapter Plates
A variety of optional architectural adapter plates for pass-through connections may be ordered for the MD floor box AAP bracket.
The AAP bracket can have up to two architectural adapter plates installed, depending on the configuration selected.
The following configurations of architectural adapter plates could be installed in the MD floor box adapter plate:
• two single spaced AAPs
• one double spaced AAP
Extron Electronics, USA
1230 South Lewis Street Anaheim, CA 92805 USA
www.extron.com
714.491.1500 Fax 714.491.1517
Beeldschermweg 6C 3821 AH Amersfoort The Netherlands +31.33.453.4040 Fax +31.33.453.4050
© 2002 Extron Electronics. All rights reserved.
Extron Electronics, Asia
135 Joo Seng Road, #04-01 PM Industrial Building Singapore 368363 +65.6383.4400 Fax +65.6383.4664
Extron Electronics, Japan
Daisan DMJ Building 6F 3-9-1 Kudan Minami Chiyoda-ku, Tokyo 102-0074 Japan +81.3.3511.7655 Fax +81.3.3511.7656
MD Floor Box AAP Bracket
Installation
MD Floor Box AAP Bracket Kit
68-720-01 Rev. A
Printed in the USA
09 02
Installation
Attach with M4 screws
Introduction
This guide covers installation of the Extron MD Floor Box AAP Bracket Kit in a Matsushita Denko (MD) floor box. It shows removal of the old bracket and installation of the new bracket/AAP unit.
Installation
CAUTION
1. Turn off and disconnect power from all equipment connected to the floor box.
2. Remove all cables connected to the portion of the floor box that is accessible when the lid is open (if applicable).
3. Open the lid and remove the two screws securing the lid to the floor box.
4. Remove the lid from the floor box by sliding the lid toward the hinge to disengage it from the box, then put the lid aside.
5. Remove the two screws securing the old adapter plate bracket to the box.
7. Remove the old adapter plate bracket and adapter plate unit from the floor box.
8. Attach and secure any single or double Extron AAP (for example, the double AAP shown below) to the MD AAP bracket with the 4-40 mounting nuts provided.
Installation and service must be performed by authorized personnel only.
3. Remove screws
9. Connect cables, if applicable, to the back of the AAP to be installed.
Slide bracket
4. Slide
If an existing adapter plate or blank plate is installed, complete steps 5 through 7, otherwise skip to step 8.
10. Place the MD AAP bracket into the floor box (as shown above), routing any cables through the back of the box.
Remove screws
6. Slide the adapter plate bracket to the center of the box and disconnect the cables attached to the back side of the adapter plate.
11. Align the two screw holes in the top of the new AAP bracket with the holes in the box. Attach the bracket with the two M4 screws provided.
MD Floor Box AAP Kit • InstallationMD Floor Box AAP Kit • Installation
32