Extron Electronics MAAP 201, MAAP 202 EUC User Manual

Extron Electronics, USA
800.633.9876 714.491.1500 FAX 714.491.1517
Extron Electronics, Europe
+800.3987.6673 +31.33.453.4040 FAX +31.33.453.4050
Extron Electronics, Asia
Extron Electronics, Japan
+81.3.3511.7655 FAX +81.3.3511.7656
www.extron.com
EU Junction Box (not included)
MAAP Mounting Adapter Plate
MAAP Modules (not included)
MAAP Plastic Cover Frame
#4 - 40 Screws (included with MAAP)
MAAP 201/202 EUC Installation Guide
Euro Channel (not included)
Mounting Bracket
Screw w/ Dogleg Attached
Back Support
MAAP Plastic Cover Frame
MAAP Module (not included)
#4 - 40 Screws (included with MAAP)
Rear View
The MAAP 201 EUC (1-EU gang) and MAAP 202 EUC (2-EU gang) mounting kits allow many of Extron's Miniature Architectural Adapter Plates (MAAPs) to be installed in 80 mm Euro Channel raceways. MAAPs must be purchased separately.
1. Run cables along the Euro Channel from the unit(s) that will be connected to the MAAP.
2. Place the mounting bracket into the front opening of the Euro Channel, so that it rests against back supports.
3. Use a screwdriver to turn the two screws on the mounting bracket so that the doglegs rotate behind the back support. Continue turning the screws so that the doglegs clamp the mounting bracket securely to the back support.
4. Place the plastic cover frame over the metal mounting bracket, inside the front opening of the Euro Channel.
5. Thread cables through the metal mounting bracket and plastic cover frame and connect them to the appropriate MAAP.
6. Insert and secure the MAAP modules to the mounting bracket, using the #4-40 screws provided with each MAAP. Tighten the screws to clamp the MAAPs and the plastic cover frame into position.
C
To avoid damaging the plastic cover frame, tighten
the socket head cap screws evenly. Do not over­tighten.
MAAP 201/202 EU Installation Guide
The MAAP 201 EU (1 EU gang) and MAAP 202 EU (2 EU gang) mounting kits allow many of Extron's Miniature Architectural Adapter Plates (MAAPs) to be installed in EU junction boxes. MAAPs must be purchased separately.
1. Run cables to the junction box from the unit(s) that will be connected to the MAAP.
2. Using the mounting screws provided with the junction box, attach the mounting adapter plate. For a 2 EU gang junction box, use two adapter plates. Ensure that they do not overlap.
The orientation of the adapter plate determines the orientation of the MAAPs.
N
3. Thread cables through the plastic cover frame and connect them to the
4. Place the plastic cover frame over the adapter plate and insert the MAAP
5. Secure the MAAP modules to the adapter plates using the #4-40 screws provided
C
These may be vertical or horizontal, depending on user requirements.
appropriate MAAP.
module(s).
with each MAAP. Tighten the screws to clamp the plastic cover frame into position.
To avoid damaging the plastic cover, tighten the socket head cap screws evenly.
Do not over-tighten.
68-1448-01
Rev B
03 08