Extron electronics M59, M59-3, M59-5, M59-6 Specifications

Specifications — M59 CableSpecifications — M59 Cable
Description
Part No.
Model
(length)
UL NEC/
C(UL) CEC
UL AWM
No.
of
Cond.
Standard Lengths
Ft. m
Shipping
Weights
Lbs. kg
Conductor (stranding)
Diameter
Nom. DCR
Nominal Core OD
Shielding Materials
(% coverage)
Inch mm pF/ft pF/m
Nom. DCR
Nominal
OD
Inch mm
Nom.
Imp.
(ohms)
Nom.
Vel.
Prop.
(3, 5, or 6) 24 AWG Coax • Aluminum Foil (100%) + Tinned Copper Serve Shield
Nonplenum Cable • Gas-injected Foamed Polyethylene Insulation • PVC Inner Jackets • Gray PVC Outer Jacket
22-185-02 (500')
M59-3
Min. bend radius: 4.0"
22-127-02 (500')
M59-5
Min. bend radius: 5.5"
22-133-02 (500')
M59-6
Min. bend radius: 6.0"
NEC CM UL-1581 CSA FT4
NEC CM UL-1581 CSA FT4
NEC CM UL-1581 CSA FT4
500 152.4 25.4 0.110 2.79
3 coax
500 152.4 42.2 0.110 2.79
5 coax
56
93
24 AWG
(7/32)
0.024"
0.61 mm Tinned Cu 26 ohms/
1k ft,
135 ohms/
1 km
Same as
above
6 coax
500 152.4
111
50.3
Same as
above
0.110
2.79
Tinned Cu
Braid (95%)
6.9 ohms/ 1k ft,
22.6 ohms/ 1 km
Same as
above.
Same as
above.
Single:
0.162 4.11
red, green,
blue
Overall:
0.402 10.21
gray
Single:
0.162 4.11
red, green,
blue, black,
yellow
Overall:
0.536 13.61
gray
Single:
0.162 4.11
red, green,
blue, black,
yellow, white
Overall:
0.584 14.83
gray
Sweep tested 5 MHz to 1 GHz.
of
Nominal
Capacitance
56.775 83%
17.3
Attenuation
MHz
1
5 10 30 50
100 200 400 700
900 1000 3000
Nominal
dB/
100 ft
-0.4
-0.9
-1.3
-2.2
-2.8
-4.0
-5.8
-8.3
-11.2
-12.8
-13.5
-31.0
25 November, 2008
dB/
100 m
-1.3
-2.8
-4.0
-6.7
-8.5
-12.2
-17.7
-25.3
-34.2
-39.0
-41.2
-94.7
Loading...