Extron electronics KP 6 Keypad, KP 6 Remote User Manual

User’s Guide
Keypad Remote Controls
68-694-01 Rev. A
Printed in the USA
07 02
KP 6 Keypad Remote
Keypad Remote Controls • Installation and OperationKeypad Remote Controls • Installation and Operation
Installation and Operation
32
Introduction
The KP 6 is designed to control MSW 4 Series, SW AV Series (4 and 6 input models only), SW VGA/Ars Series, and SW RGBHV/ A Series switchers, or other Extron products with contact closure ports or ports labeled as “Remote.”
The KP 6 is a contact closure remote for selecting the switcher’s input. When a number key is pressed, the wire associated with that input is momentarily shorted to ground, making the switcher switch to that input.
The KP 6 can control up to 6 inputs and requires no power.
Installation
Installation with a 9-pin D-sub connector
Many switchers, such as the SW6 VGA Ars Switcher, come equipped with a 9-pin D-sub connector. To use the KP 6 Keypad Remote Control on this type of switcher, install it as follows:
1. Power down the switcher.
2. Connect the KP 6 adapter’s 9-pin plug to the contact closure
connector on the switcher’s rear panel.
3. Position the KP 6 Keypad for the most convenient operation.
4. Power up the switcher.
Figure 1 — Typical KP 6 application (with 9-pin D­sub connector)
Figure 2 — 9-pin Sub-D connector pinout
Installation with a captive screw connector
Some switchers, such as the MSW 4 Series, are not equipped with 9-pin D-sub connectors and have a 3.5mm, 5-pole captive screw connector (labeled “Contact”) instead. In order to use the KP 6 Keypad Remote Control with these switchers, a captive screw connector (included with the switcher) must be used. To use a captive screw connector, the existing 9-pin D-sub connector must be removed from the cable and a captive screw connector installed.
To install the captive screw connector, remove the wire from the 9-pin D-sub connector, then strip the wires and insert them into the new connector (supplied with the switcher). Wire the connector as shown here. Tighten the screws to secure the wires. Clip off the green and blue wires.
Do not tin the stripped wire leads before installing the captive screw connector. Tinned wires are not as secure in the captive screw connectors and could pull out.
Install the KP 6 Keypad Remote Control on this type of switcher as follows:
1. Rewire the connector on the KP 6 Keypad Remote Control.
2. Power down the switcher.
3. Connect the KP 6 adapter’s captive screw connector to the
“Contact” connector on the switcher’s rear panel.
4. Position the KP 6 Keypad for the most convenient operation.
5. Power up the switcher.
Brown
Red
Orange
Yellow
Black
4
3
2
1
25 foot cable
KP 6 Keypad
Remote Control
SW6 VGA Ars Switcher
SW6 VGA Ars
REMOTE
100-240V 0.2A
INPUTS
1
2
3
4
5
50-60Hz
OUTPUT
OUTPUT
LR
SW6 VGA Ars
6
niP erusolctcatnoC n Wire coloroitcnuF
1
1#nI 1 Brown#tupnI
2
3
4
2#nI 2 Red#tupnI
5 dnG d BlacknuorglangiS
6
3#nI 3 Orange#tupnI
7
4#nI 4 Yellow#tupnI
8
5#nI 5 Green#tupnI
9
6#nI 6 Blue#tupnI
Not used
Not used
Male
15
69
Users Guide
Extron Electronics, USA
1230 South Lewis Street Anaheim, CA 92805 USA
714.491.1500 Fax 714.491.1517
Extron Electronics, Europe
Beeldschermweg 6C 3821 AH Amersfoort The Netherlands +31.33.453.4040 Fax +31.33.453.4050
Extron Electronics, Asia
135 Joo Seng Road, #04-01 PM Industrial Building Singapore 368363 +65.6383.4400 Fax +65.6383.4664
Extron Electronics, Japan
Daisan DMJ Building 6F 3-9-1 Kudan Minami Chiyoda-ku, Tokyo 102-0074 Japan +81.3.3511.7655 Fax +81.3.3511.7656
www.extron.com
© 2002 Extron Electronics. All rights reserved.
Figure 3 — KP 6 application (with 5-pole captive screw connector)
Operation
To select an input using the KP 6 Keypad Remote Control, press the number key for the desired input.
Specifications
25 foot cable
KP 6 Keypad
Remote Control
MSW 4V Switcher
MSW 4V SDI
POWER
1.2V .5A MAX
INPUTS
OUTPUTS
1
2
3
4
CONTACT
1
2
3
4
A
B
Power ............................................. None required
Temperature/humidity .............. Storage -40° to +158° (-40° to +70°C)/ 10%
to 90%, non-condensing
Operating ...................................... +32° to +122° (0° to +50°C)/ 10% to 90%,
non-condensing
Enclosure type .............................. Plastic
Approvals ..................................... CE
MTBF ............................................. 30,000 hours
Warranty ....................................... 3 years parts and labor
Loading...