Extron Electronics IR Link User Manual

User’s Manual
www.extron.com
Extron Electronics, USA
1230 South Lewis Street Anaheim, CA 92805 USA
714.491.1500 Fax 714.491.1517
Extron Electronics, Europe
© 2002 Extron Electronics. All rights reserved.
Extron Electronics, Asia
135 Joo Seng Road, #04-01 PM Industrial Building Singapore 368363 +65.6383.4400 Fax +65.6383.4664
Extron Electronics, Japan
Daisan DMJ Building 6F 3-9-1 Kudan Minami Chiyoda-ku, Tokyo 102-0074 Japan +81.3.3511.7655 Fax +81.3.3511.7656
IR Link
Infrared Signal Repeater
68-602-01
Printed in the USA
Precautions
Safety Instructions • English
This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment.
This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product's enclosure that may present a risk of electric shock.
Caution
Read Instructions • Read and understand all safety and operating
instructions before using the equipment.
Retain Instructions • The safety instructions should be kept for future
reference.
Follow Warnings • Follow all warnings and instructions marked on the
equipment or in the user information.
Avoid Attachments • Do not use tools or attachments that are not
recommended by the equipment manufacturer because they may be hazardous.
Consignes de Sécurité • Français
Ce symbole sert à avertir l’utilisateur que la documentation fournie avec le matériel contient des instructions importantes concernant l’exploitation et la maintenance (réparation).
Ce symbole sert à avertir l’utilisateur de la présence dans le boîtier de l’appareil de tensions dangereuses non isolées posant des risques d’électrocution.
Attention
Lire les instructions• Prendre connaissance de toutes les consignes de
sécurité et d’exploitation avant d’utiliser le matériel.
Conserver les instructions• Ranger les consignes de sécurité afin de
pouvoir les consulter à l’avenir.
Respecter les avertissements • Observer tous les avertissements et
consignes marqués sur le matériel ou présentés dans la documentation utilisateur.
Eviter les pièces de fixation • Ne pas utiliser de pièces de fixation ni
d’outils non recommandés par le fabricant du matériel car cela risquerait de poser certains dangers.
Sicherheitsanleitungen • Deutsch
Dieses Symbol soll dem Benutzer in der im Lieferumfang enthaltenen Dokumentation besonders wichtige Hinweise zur Bedienung und Wartung (Instandhaltung) geben.
Dieses Symbol soll den Benutzer darauf aufmerksam machen, daß im Inneren des Gehäuses dieses Produktes gefährliche Spannungen, die nicht isoliert sind und die einen elektrischen Schock verursachen können, herrschen.
Achtung
Lesen der Anleitungen • Bevor Sie das Gerät zum ersten Mal verwenden,
sollten Sie alle Sicherheits-und Bedienungsanleitungen genau durchlesen und verstehen.
Aufbewahren der Anleitungen • Die Hinweise zur elektrischen Sicherheit
des Produktes sollten Sie aufbewahren, damit Sie im Bedarfsfall darauf zurückgreifen können.
Befolgen der Warnhinweise • Befolgen Sie alle Warnhinweise und
Anleitungen auf dem Gerät oder in der Benutzerdokumentation.
Keine Zusatzgeräte • Verwenden Sie keine Werkzeuge oder Zusatzgeräte,
die nicht ausdrücklich vom Hersteller empfohlen wurden, da diese eine Gefahrenquelle darstellen können.
Instrucciones de seguridad • Español
Este símbolo se utiliza para advertir al usuario sobre instrucciones importantes de operación y mantenimiento (o cambio de partes) que se desean destacar en el contenido de la documentación suministrada con los equipos.
Este símbolo se utiliza para advertir al usuario sobre la presencia de elementos con voltaje peligroso sin protección aislante, que puedan encontrarse dentro de la caja o alojamiento del producto, y que puedan representar riesgo de electrocución.
Precaucion
Leer las instrucciones • Leer y analizar todas las instrucciones de
operación y seguridad, antes de usar el equipo.
Conservar las instrucciones • Conservar las instrucciones de seguridad
para futura consulta.
Obedecer las advertencias • Todas las advertencias e instrucciones
marcadas en el equipo o en la documentación del usuario, deben ser obedecidas.
Evitar el uso de accesorios • No usar herramientas o accesorios que no
sean especificamente recomendados por el fabricante, ya que podrian implicar riesgos.
Warning
Power sources • This equipment should be operated only from the power source
indicated on the product. This equipment is intended to be used with a main power system with a grounded (neutral) conductor. The third (grounding) pin is a safety feature, do not attempt to bypass or disable it.
Power disconnection • To remove power from the equipment safely, remove all
power cords from the rear of the equipment, or the desktop power module (if detachable), or from the power source receptacle (wall plug).
Power cord protection • Power cords should be routed so that they are not likely to
be stepped on or pinched by items placed upon or against them.
Servicing • Refer all servicing to qualified service personnel. There are no user-
serviceable parts inside. To prevent the risk of shock, do not attempt to service this equipment yourself because opening or removing covers may expose you to dangerous voltage or other hazards.
Slots and openings • If the equipment has slots or holes in the enclosure, these are
provided to prevent overheating of sensitive components inside. These openings must never be blocked by other objects.
Lithium battery • There is a danger of explosion if battery is incorrectly replaced.
Replace it only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions.
Avertissement
Alimentations• Ne faire fonctionner ce matériel qu’avec la source d’alimentation
indiquée sur l’appareil. Ce matériel doit être utilisé avec une alimentation principale comportant un fil de terre (neutre). Le troisième contact (de mise à la terre) constitue un dispositif de sécurité : n’essayez pas de la contourner ni de la désactiver.
Déconnexion de l’alimentation• Pour mettre le matériel hors tension sans danger,
déconnectez tous les cordons d’alimentation de l’arrière de l’appareil ou du module d’alimentation de bureau (s’il est amovible) ou encore de la prise secteur.
Protection du cordon d’alimentation • Acheminer les cordons d’alimentation de
manière à ce que personne ne risque de marcher dessus et à ce qu’ils ne soient pas écrasés ou pincés par des objets.
Réparation-maintenance • Faire exécuter toutes les interventions de réparation-
maintenance par un technicien qualifié. Aucun des éléments internes ne peut être réparé par l’utilisateur. Afin d’éviter tout danger d’électrocution, l’utilisateur ne doit pas essayer de procéder lui-même à ces opérations car l’ouverture ou le retrait des couvercles risquent de l’exposer à de hautes tensions et autres dangers.
Fentes et orifices • Si le boîtier de l’appareil comporte des fentes ou des orifices,
ceux-ci servent à empêcher les composants internes sensibles de surchauffer. Ces ouvertures ne doivent jamais être bloquées par des objets.
Lithium Batterie • Il a danger d'explosion s'll y a remplacment incorrect de la
batterie. Remplacer uniquement avec une batterie du meme type ou d'un ype equivalent recommande par le constructeur. Mettre au reut les batteries usagees conformement aux instructions du fabricant.
Vorsicht
Stromquellen • Dieses Gerät sollte nur über die auf dem Produkt angegebene
Stromquelle betrieben werden. Dieses Gerät wurde für eine Verwendung mit einer Hauptstromleitung mit einem geerdeten (neutralen) Leiter konzipiert. Der dritte Kontakt ist für einen Erdanschluß, und stellt eine Sicherheitsfunktion dar. Diese sollte nicht umgangen oder außer Betrieb gesetzt werden.
Stromunterbrechung • Um das Gerät auf sichere Weise vom Netz zu trennen,
sollten Sie alle Netzkabel aus der Rückseite des Gerätes, aus der externen Stomversorgung (falls dies möglich ist) oder aus der Wandsteckdose ziehen.
Schutz des Netzkabels • Netzkabel sollten stets so verlegt werden, daß sie nicht
im Weg liegen und niemand darauf treten kann oder Objekte darauf- oder unmittelbar dagegengestellt werden können.
Wartung • Alle Wartungsmaßnahmen sollten nur von qualifiziertem
Servicepersonal durchgeführt werden. Die internen Komponenten des Gerätes sind wartungsfrei. Zur Vermeidung eines elektrischen Schocks versuchen Sie in keinem Fall, dieses Gerät selbst öffnen, da beim Entfernen der Abdeckungen die Gefahr eines elektrischen Schlags und/oder andere Gefahren bestehen.
Schlitze und Öffnungen • Wenn das Gerät Schlitze oder Löcher im Gehäuse
aufweist, dienen diese zur Vermeidung einer Überhitzung der empfindlichen Teile im Inneren. Diese Öffnungen dürfen niemals von anderen Objekten blockiert werden.
Litium-Batterie • Explosionsgefahr, falls die Batterie nicht richtig ersetzt wird.
Ersetzen Sie verbrauchte Batterien nur durch den gleichen oder einen vergleichbaren Batterietyp, der auch vom Hersteller empfohlen wird. Entsorgen Sie verbrauchte Batterien bitte gemäß den Herstelleranweisungen.
Advertencia
Alimentación eléctrica • Este equipo debe conectarse únicamente a la fuente/tipo
de alimentación eléctrica indicada en el mismo. La alimentación eléctrica de este equipo debe provenir de un sistema de distribución general con conductor neutro a tierra. La tercera pata (puesta a tierra) es una medida de seguridad, no puentearia ni eliminaria.
Desconexión de alimentación eléctrica • Para desconectar con seguridad la
acometida de alimentación eléctrica al equipo, desenchufar todos los cables de alimentación en el panel trasero del equipo, o desenchufar el módulo de alimentación (si fuera independiente), o desenchufar el cable del receptáculo de la pared.
Protección del cables de alimentación • Los cables de alimentación eléctrica se
deben instalar en lugares donde no sean pisados ni apretados por objetos que se puedan apoyar sobre ellos.
Reparaciones/mantenimiento • Solicitar siempre los servicios técnicos de personal
calificado. En el interior no hay partes a las que el usuario deba acceder. Para evitar riesgo de electrocución, no intentar personalmente la reparación/ mantenimiento de este equipo, ya que al abrir o extraer las tapas puede quedar expuesto a voltajes peligrosos u otros riesgos.
Ranuras y aberturas • Si el equipo posee ranuras o orificios en su caja/alojamiento,
es para evitar el sobrecalientamiento de componentes internos sensibles. Estas aberturas nunca se deben obstruir con otros objetos.
Batería de litio • Existe riesgo de explosión si esta batería se coloca en la posición
incorrecta. Cambiar esta batería únicamente con el mismo tipo (o su equivalente) recomendado por el fabricante. Desachar las baterías usadas siguiendo las instrucciones del fabricante.
FCC Class A Notice
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.
Note: This unit was tested with shielded cables on the peripheral devices. Shielded cables must be used with the unit to ensure compliance.
Extron’s Warranty
Extron Electronics warrants this product against defects in materials and workmanship for a period of three years from the date of purchase. In the event of malfunction during the warranty period attributable directly to faulty workmanship and/or materials, Extron Electronics will, at its option, repair or replace said products or components, to whatever extent it shall deem necessary to restore said product to proper operating condition, provided that it is returned within the warranty period, with proof of purchase and description of malfunction to:
USA, Canada, South America, Europe, Africa, and the Middle East: and Central America:
Extron Electronics Beeldschermweg 6C 1230 South Lewis Street 3821 AH Amersfoort Anaheim, CA 92805, USA The Netherlands
Asia: Japan:
Extron Electronics, Asia Daisan DMJ Bldg. 6F, 135 Joo Seng Road, #04-01 3-9-1 Kudan Minami PM Industrial Bldg. Chiyoda-ku, Tokyo 102-0074 Singapore 368363 Japan
This Limited Warranty does not apply if the fault has been caused by misuse, improper handling care, electrical or mechanical abuse, abnormal operating conditions or non-Extron authorized modification to the product.
If it has been determined that the product is defective, please call Extron and ask for an Applications Engineer at (714) 491-1500 (USA), 31.33.453.4040 (Europe),
65.6383.4400 (Asia), or 81.3.3511.7655 (Japan) to receive an RA# (Return Authorization number). This will begin the repair process as quickly as possible.
Units must be returned insured, with shipping charges prepaid. If not insured, you assume the risk of loss or damage during shipment. Returned units must include the serial number and a description of the problem, as well as the name of the person to contact in case there are any questions.
Extron Electronics makes no further warranties either expressed or implied with respect to the product and its quality, performance, merchantability, or fitness for any particular use. In no event will Extron Electronics be liable for direct, indirect, or consequential damages resulting from any defect in this product even if Extron Electronics has been advised of such damage.
Please note that laws vary from state to state and country to country, and that some provisions of this warranty may not apply to you.
Extron Electronics, Europe
Extron Electronics, Japan
Table of Contents
Chapter 1 • Introduction .......................................................... 1-1
About the IR Link ................................................................... 1-2
Features ...................................................................................... 1-2
Chapter 2 • Installation and Operation ......................... 2-1
Installation Overview.......................................................... 2-2
UL Requirements.................................................................... 2-2
Preparing the Site and Installing the Wall Box ..... 2-3
Rear Panel Connectors and Cabling............................. 2-5
Connecting an IR Link to a MediaLink Switcher.................. 2-6
Connecting an IR Link to a MediaLink Controller ............... 2-7
Connecting an IR Link to a power supply and
an IR Emitter ........................................................................ 2-10
Front Panel Features and Operation ......................... 2-11
Testing/Troubleshooting .................................................. 2-12
Appendix A • Specifications, Part Numbers,
and Dimensions ............................................................................. A-1
Specifications ......................................................................... A-2
Included Parts......................................................................... A-3
Accessories............................................................................... A-3
Cables ......................................................................................... A-3
Dimensions .............................................................................. A-4
Template .................................................................................... A-5
All trademarks mentioned in this manual are the properties of their respective owners.
68-602-01 Rev. B
Printed in the USA
02 02
iIR Link• Table of Contents
Table of Contents, cont’d
IR Link
Chapter One
1
Introduction
About the IR Link
Features
ii
IR Link • Table of Contents
Introduction
About the IR Link
The Extron IR Link is a one-gang size, hardwired, infrared signal repeater that can be used with any Extron product that uses 38 kHz carrier frequency IR signals. Infrared signals received by the IR Link are passed on to the Extron device, which can be installed out of the direct line of sight of the IR remote controls.
Features
Grey, black, or white faceplates — The IR Link is offered in
three shades for integration into a variety of environments.
Furniture and wall mountability — The IR Link can be
mounted onto or in furniture or walls either directly or attached to a standard electrical wall box or mud ring.
IR Link
Chapter Two
2
1-2
Installation and Operation
Installation Overview
UL Requirements
Rear Panel Connectors and Cabling
Front Panel Features and Operation
Testing/Troubleshooting
IR Link • Introduction
Installation and Operation
Installation Overview
CAUTION
To install and set up an IR Link, follow these steps:
Turn the equipment off. Make sure that the IR Link is
1
disconnected from the power source.
Select the site and run cables through the wall or furniture
2
to where the IR Link will be installed.
Prepare the site (cut a hole, install an electrical box or mud
3
ring/mounting bracket). See the instructions in this chapter for site preparation details. Cable clamps should be used to hold the cables in place for strain relief. Trim back and/or insulate exposed cable shields with heat shrink to reduce the chance of short circuits.
Attach connectors to the cables. See “Rear Panel
4
Connectors and Cabling” in this chapter.
Attach the terminated cables to the IR Link’s rear panel
5
connectors and, if applicable, to the remotely controlled Extron device.
Verify correct wiring and cabling, and test the system: con-
6
nect the devices to a power source, turn them on, aim an IR remote control at the IR Link, and check for the appropri­ate response at the remotely controlled Extron device.
Disconnect all the devices from the power source(s), and
7
correct any cabling errors.
Being careful not to damage the cables, place the IR Link
8
onto/against the wall or furniture and secure it to the wall or furniture with the provided screws.
Restore power to the system.
9
Installation and service must be performed by authorized personnel only. These units must be installed in accordance with the National Electrical Code and with local electrical codes and used with UL approved electrical boxes. See “UL Require­ments” on this page.
UL Requirements
1. This device is not to be connected to a centralized DC power source or used beyond its rated voltage range.
2. This unit must be installed in a UL listed junction box.
The UL approved electrical wall box (junction box) is not
included with the IR Link; the installer is responsible for obtaining and installing the box.
3. These units must be installed in accordance with the National Electrical Code and with local electrical codes.
Preparing the Site and Installing the Wall Box
The IR Link can be installed in a one-gang electrical wall box or a mud ring-type mounting bracket. Choose a location that will allow cable runs without interference. Allow enough depth for both the wall box and the cables. The box should be at least 1.5” (3.8 cm) deep to accommodate the circuit board, connectors, and cables. Install the cables into the wall, furniture, or conduits before installing the IR Link.
The installation must conform to national and local electrical codes and to the IR Link’s size requirements. A dimensional drawing and an actual-size cut-out template are provided in appendix A of this manual.
1. Cut out the center portion of the cut-out template that corresponds to the type of installation being used (wall box or no wall box). If installing a mud ring-type mounting bracket, use the template that came with the mud ring.
2. Place the template (or the wall box) against the installation surface, and mark the guidelines for the opening on the wall or furniture.
3. Cut out the material from the marked area.
4. Check the opening size by inserting the wall box into the
opening. The box and the IR Link’s circuit board should fit easily into the opening. Enlarge or smooth the edges of the opening if needed.
5. Feed cables through the wall box punch-out holes, and secure them with cable clamps to provide strain relief.
6. Exposed cable shields (braids or foil) are potential sources of short circuits. Trim back and/or insulate shields with heat shrink.
Screw
Braided Shield
Cable Clamp
Install Cable
Foil Shield
Grounding outer braided and foil shields
Metal Wall Box
2-2
IR Link • Installation and Operation
IR Link • Installation and Operation
2-3
Installation and Operation, cont’d
1
CAUTION
To prevent short circuits, the outer foil shield can be
Rear Panel Connectors and Cabling
cut back to the point where the cable exits the cable clamp. Both braided and foil shields should be connected to an equipment ground at the other end of the cable.
7. Insert the wall box into the opening, and attach it to the wall, stud, or furniture with nails or screws, leaving the front edge flush with the outer wall or furniture surface. See the following illustration.
Cable Clamp
Screws or NailsScrews or Nails
Wall Stud
Communications connectors — Use these connectors to connect
1
the IR Link to another Extron device(s). Both connectors function the same way, so they are interchangeable.
Plug one end of an Extron Comm-Link cable into one of these
3.5 mm, 5-pole captive screw connectors, and plug the other end into a connector on an Extron MediaLink Controller (MLC), MediaLink Control Module, or MediaLink Switcher. If the IR Link is not part of a MediaLink system, connect an external power supply to one connector, and connect one or more IR
Wall Stud
Installation Cable
Cable Clamp
Installation Cable
Attaching a wall box to a wall stud
If attaching the wall box to wood, use four #8 or #10 screws or 10-penny nails. A minimum of 1/2 inch (1.3 cm) of screw threads must penetrate the wood.
If attaching the wall box to metal studs or furniture, use four #8 or #10 self-tapping sheet metal screws or machine bolts with matching nuts.
Emitters to the other connector.
8. Cable and test the IR Link before fastening it into the wall box. The cables will be inaccessible after installation.
The MediaLink Switcher and MediaLink Controller provide 12VDC to the IR Link on pin B and a ground on pin A, so there is no need for an additional power supply. If the IR Link is used with another Extron device (switcher, scan converter, scaler), connect an external DC power supply (such as Extron part #70-055-01) to those pins.
Connect a maximum of one (1) IR Link to a device. Do not connect more than one IR Link (either in parallel or in series) to a switcher or a MediaLink Controller.
2-4
IR Link • Installation and Operation
IR Link • Installation and Operation
2-5
Installation and Operation, cont’d
Connecting an IR Link to a MediaLink Switcher
1. If it hasn’t already been done, cut a length (150’/45.7 m or less) of Extron Comm-Link cable to go between the MediaLink Switcher and the IR Link.
2. Attach a 3.5 mm, 5-pole captive screw connector to each end of the cable. Only three wires (between pins A, B, and D on the IR Link end and pins C, end) are required. Wire the cable as shown in the following illustration. Connectors are included with the IR Link, but the cable must be purchased separately. See appendix A for cable part numbers.
3. Plug the 5-pole connector into one of the IR Link’s communications connectors.
4. Plug the other end of the cable into the rear panel MLC/IR port of the MediaLink Switcher.
Do not connect more than one (1) IR Link (either in parallel or in series) to a switcher.
MediaLink
Switcher
MLC/IR
ABC
, and + on the switcher
Connecting an IR Link to a MediaLink Controller
The IR Link can either be connected directly to an MLC or be part of a daisy chain of MediaLink Control Modules connected to the MLC.
1. If it wasn’t done when the wall box was installed, cut a length of Extron Comm-Link cable to go between the MLC and the IR Link.
2. Attach a 3.5 mm, 5-pole captive screw connector to the end of the cable that will be plugged into the IR Link, and connect wires on the other end of the cable to the MLC’s IR/RCM 4-pole direct insertion captive screw connector. Wire both ends of the cable identically (pin A to pin A, pin B to pin B, etc.).
Only three wires (pins A, B, and D) are required (as shown below), but use four wires (A, B, C, D) if the IR Link will be daisy chained with MediaLink Control Modules (as shown in the illustration on the next page).
The maximum total distance between the MLC and the IR Link is 150’ (45.7 m).
Do not connect more than one IR Link (either in parallel or in series) to an MLC.
Total
distance
from MLC:
150' (45.7 m)
max.
IR Link
2-6
A
+12VDC
100-240V 0.2A 50/60 Hz
.5A MAX
INPUT 1
INPUT 2
VIDEO
R-Y
VIDEO
R-Y
Y
Y
B-Y
B-Y
C
C
L LRR LR
INPUT 3
VIDEO
Y
C
C
INPUT 4
R-Y
RH/
HV
G
V
B-Y
B
LR LR LR
Ground ( )
Modulated IR
INPUT 5
RH/
HV
G
V
B
RH/
G
B
B
D
INPUT 6
RGB
RH/
R-Y
HV
HV
G
Y
V
V
B
B-Y
AUX/MIXEFFECTS
SENDLRRETURN
LR
LR
MLS 506MA Rear Panel
MediaLink Switcher to an IR Link
IR Link • Installation and Operation
YUV
C
VIDEO
S-VIDEO
Y
AUDIO OUT
FIXED VARIABLE
LRLR
MONO AMPLIFIED OUTPUT
4 ohm
COMM 8 ohm 70V
MLC/IR RS232
ABC
CONTACT CLOSURE
MLA-Remote
IR Link
150' (45.7 m) max.
SIGNAL
IR Link
SIGNAL
VCR DVD Laptop
IR LINK
MediaLink Controller
MLC 206
2-7
IR Link
+12VDC
A B
Ground ( )
D
Modulated IR
MLC
IR
/
RCM
IR LINK
ABCD
IR / RCM
port
A B
D
MLC 206 to an IR Link
MLA Remote
Extron
DISPLAY POWER
VOLUME
MAX/
MIN
MLC 206
IR Link • Installation and Operation
Installation and Operation, cont’d
A B
D
IR Link
Control Module
ADBC E ADBC E
12
ON
A
+12VDC
Ground ( )
B
Control signal (IRCM)
C
Modulated IR (IR Link)
D
MLC
IR
/
RCM
ABCD
IR / RCM
port
MLC 206 to a Control Module to an IR Link
Connectors are included with the IR Link, but the cable must be purchased separately. See appendix A for cable part numbers.
3. Plug the 5-pole connector into one of the IR Link’s communications connectors.
4. Cut a length of cable and attach 5-pole connectors to both ends of it for each additional MediaLink control module that will be connected in a daisy chain. Wire both ends of the cable identically (pin A to pin A, pin B to pin B, etc.). Up to a total of 4 control modules in any combination of models and one IR Link can be daisy chained together and connected to the MLC as long as each control module has a
A B C
D
MLA Remote
Extron
MLC 206
DISPLAY POWER
VOLUME
MAX/
MIN
Total
distance
from MLC:
150' (45.7 m)
max.
IR Link
SIGNAL
Tx
VCR CONTROL
REW PLAY FWD PAUSE STOP
Control Module
VCR DVD Laptop
IR LINK
MediaLink Controller
unique address Refer to the Control Modules User’s Manual and the Relay Control Modules User’s Manual for details on addresses and DIP switches.
5. Plug one end of the cable into the IR Link’s remaining communications connector, and plug the other end into a communications connector on the control module. The photo below shows an IR Link and control modules (IRCMs, ACMs, RCMs, and/or CMs) connected to an MLC in a typical daisy chain setup.
Do not connect more than one IR Link (either in parallel or in series) to an MLC. Also, do not connect more than four control modules to an MLC.
To 1–2 additional
IR Control Modules
(IRCMs)
IRCM #2 rear view
IRCM #1 rear view
MLC 206
MLM faceplate
IR Emitter
(Connect 1 per
each IRCM.)
RS-232
projector
connection
MLC 206 rear view
IR Link Infrared Repeater
rear view
To an
MLS
switcher
An IR Link and control modules connected to an MLC
6. Connect one Extron IR Emitter to the MLC’s Display/ Source Control IR connector for each control module that is part of the system, or connect an Extron IR Broadcaster instead.
2-8
IR Link • Installation and Operation
IR Link • Installation and Operation
2-9
Installation and Operation, cont’d
Connecting an IR Link to a power supply and an IR Emitter
An external, stand-alone power supply is only necessary if the IR Link is not part of a MediaLink system.
1. Attach an external 12VDC power supply to pins A (+12VDC) and B (ground) of a 3.5 mm captive screw connector, and plug it into one of the IR Link’s communications connectors as shown below.
Connect a maximum of one IR Link. Do not connect more than one IR Link (either in parallel or in series).
2. Attach the black wire of an Extron IR Emitter to pin B (ground) and the white striped wire to pin D (IR signal) of a 3.5 mm captive screw connector, and plug it into the IR Link’s remaining communications connector, as shown below. Two or three emitters can be wired to the same connector, if needed.
3. Place the head of the IR Emitter near or in front of the IR pickup device of the IR-controllable Extron product.
Ground ( )
B
Modulated IR
D
(IR Link)
B
D
White striped wire only
IR controlled
IR
Emitter
To an
Extron device
Front Panel Features and Operation
1
2
3
SIGNAL
1
IR LINK
2-10
A
A
+12VDC
Ground ( )
B
B
IR Link
External power supply (12VDC, 1 A max.)
Stand-alone IR Link with power supply and IR Emitter
IR Link • Installation and Operation
MLA Remote
SIGNAL
IR Link
Mounting screws — These two screws attach the IR Link to the
1
electrical wall box, mud ring, or furniture.
IR signal pickup device — The IR Link receives infrared signals
2
from an IR remote control through this window so it can be converted to an electronic signal that is sent to a connected Extron device to control that device. The output carrier frequency is 38 kHz, and the IR Link should be used only with Extron products. When you use the IR remote control, point it directly at this window for best results.
Signal LED — This LED lights to indicate that the IR Link is
IR LINK
3
receiving an infrared signal.
IR Link • Installation and Operation
2-11
Installation and Operation, cont’d
Testing/Troubleshooting
Before installing the IR Link into the wall or furniture, test the system to make sure that the connections are correct and the IR Link is working correctly.
1. Connect the cables between the MediaLink Controller or MediaLink Switcher and the IR Link, and connect the Controller or Switcher to a power source;
or
connect the IR Link’s external power supply to a power source and connect the IR-controllable Extron device to a power source.
Make sure that only one IR Link is connected to the controller, switcher, or power supply.
2. Aim the Extron device’s remote control at the IR Link and press one of the buttons. Watch the IR Link’s Signal LED, and observe the Extron device or the display connected to the device.
2A If the Signal LED does not light when the IR remote
control’s button is pressed, check the captive screw connector wiring at the MediaLink Controller or MediaLink Switcher (if applicable) and at the IR Link’s connectors.
If the conductor assignments are not correct at both ends of the cable, the IR Link will not turn on, and circuits may be damaged if power is applied to the wrong pin.
2B If power is present at the MediaLink Controller/
Switcher/power supply and at the IR Link, the Signal LED lights when the remote control’s button is pressed, but the MediaLink Controller, MediaLink Switcher, or other Extron device does not respond as expected, verify that the device has been set up or programmed correctly.
3. Call the Extron S3 Sales and Technical Support Hotline if the item(s) being controlled still does (do) not respond when the remote control’s buttons are pressed.
IR Link
Appendix A
A
Specifications, Part Numbers,
and Dimensions
Specifications
Included Parts
Accessories
2-12
Cables
Dimensions
Template
IR Link • Installation and Operation
Specifications, Part Numbers, Dimensions
Specifications
Control/remote — IR repeater
IR controller module ................... Extron IR remote controls only
IR output carrier frequency........ 38 kHz
Use the IR Link with Extron products only.
General
Power............................................. 12VDC, 0.21 A from an Extron MediaLink
Controller (MLC), MediaLink Switcher (MLS), or external power supply
Temperature/humidity .............. Storage -40° to +158°F (-40° to +70°C) /
10% to 90%, non-condensing Operating +32° to +122°F (0° to +50°C) /
10% to 90%, non-condensing
Rack mount................................... No, but furniture/wall mountable
Enclosure type.............................. Metal
Enclosure dimensions
Faceplate (1-gang).... 4.5" H x 2.8" W x 0.1” D (11.4 cm H x
7.1 cm W x 0.3 cm D) (1-gang)
Circuit board ............ 2.6" H x 1.75" W x 0.8" D
(4.1 cm H x 4.4 cm W x 2.0 cm D)
(Depth includes connectors and
components.)
Allow at least 1.5” (3.8 cm) depth within
the wall box or furniture to accommodate
the circuit board, connectors, and cables.
Product weight............................. 0.1 lbs (<0.1 kg)
Shipping weight ........................... 1 lb (0.5 kg)
Vibration ....................................... ISTA/NSTA 1A in carton
(International Safe Transit Association)
Listings .......................................... UL, CUL as a component of the
MediaLink Controller (MLC 206)
Compliances ................................. CE, FCC Class A, VCCI, AS/NZS, ICES as
a component of the MediaLink
Controller (MLC 206)
MTBF ............................................. 30,000 hours
Warranty ....................................... 3 years parts and labor
Included Parts
These items are included in each order for an IR Link:
Included parts Part number
IR Link (grey, black, white) 60-404-01, -02, -03
3.5 mm, 5-pole captive screw connectors 10-319-10 IR Link User’s Manual 68-602-01
Accessories
Miscellaneous accessories Part number
12VDC, 1 A power supply 70-055-01 IR Emitter 19-823-01
Cables
Comm-link cable Part number
50 feet/15.2 meters long 26-461-01 100 feet/30.5 meters long 26-461-02
Conductor gauges in Extron Comm-Link cables
red and black single strands (for power/ground) 18 AWG
white and violet shielded single strands (for signals) 22 AWG
drain wire 24 AWG
Specifications are subject to change without notice.
IR Link • Specifications, Part Numbers
IR Link • Specifications, Part Numbers
A-3A-2
Specifications, Part Numbers, Dimensions, cont’d
Dimensions
The following diagram has been reduced to fit on the page. All dimensions are given in inches. The symbol “ø“ indicates a diameter.
R.250
(4 PLCS)
4.500
3.890
3.375
+.003/
Ø.166
THRU
-.000
PEM INSERT BSOS-440-16
(2 PLCS)
OR EQUIV. INSERT FROM
NEAR SIDE. (2 REQ'D)
2.250
1.450
1.125
0.610
0.000
0.000
0.720
1.395
1.808
2.070
Ø.156 THRU WITH Ø.290x82˚ C'SINK (2 PLCS)
DETAIL 'A'
Ø.133 THRU
2.790
R.060
TOP EDGE
ALL AROUND
(.100)
Template
Use a 100% size photocopy of the cut-out template below as a guide for cutting a hole in the wall or furniture.
The medium grey area
indicates the cut-out area
(4.13"H x 2.3"W) for a
regular electrical wall box.
To install the IR Link
wall box, use the cut-out area
(2.8" H x 1.9" W) indicated
by the dotted line.
The dashed line
indicates the cut-out
area (3.13"H x
2.13"W) for a
compact, adjustable
electrical wall box.
without
a
A-4
R.062
(4 PLCS)
0.040 RECESS
ON NEAR SIDE.
IR Link • Specifications, Part Numbers
.640 SQ.
.320
DETAIL 'A'
.388
.775
+.050
-.000
SQ.
IR Link • Specifications, Part Numbers
A-5
Specifications, Part Numbers, Dimensions, cont’d
This page was intentionally left blank.
This page was intentionally left blank.
A-6 A-7
IR Link • Specifications, Part Numbers
IR Link • Specifications, Part Numbers
Specifications, Part Numbers, Dimensions, cont’d
This page was intentionally left blank.
A-8
IR Link • Specifications, Part Numbers
Loading...