The socket outlet shall be installed near the equipment and shall be accessible.
For Models with 110 / 220V Power Selector:
Caution: Before applying power to this unit, the voltage selector must be set to the appropriate setting to match local A/C line
voltage. Improper setting of the voltage selector may cause damage to the unit and create a potential fire hazard.
The voltage selector is a round switch located next to the A/C power input connector which looks
like this:
Using a straight slot screwdriver or small coin, rotate the selector to the correct position so that
the arrow lines up with 110 or 220 as appropriate for local power line voltage as indicated in the
chart below:
Local A/C VoltageVoltage Selector Setting
110 ~ 120 VAC110
220 ~ 240 VAC220
For all Models:
No serviceable parts inside the unit. Refer service to a qualified technician.
For Models with Internal or External Fuses:
For continued protection against fire hazard, replace only with same type and rating of fuse.
Caution: Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by
the manufacturer. Dispose of used batteries according to the manufacturer’s instructions.
Instructions d’installation et de sécurité
Pour les modèles sans interrupteur de courant:
La prise de courant d’alimentation sera installé près de l’équipement et sera accessible.
Pour les modèles avec un sélecteur d’alimentation 110V/220V:
Attention: Avant de connecter l’appareil au circuit d’alimentation, le sélecteur de courant doit être positionné sur la sélection
appropriée correspondant au voltage du circuit de courant alternatif local. Une mauvaise sélection peut engendrer des
dommages à l’appareil et créer un danger d’incendie.
Le sélecteur d’alimentation est un commutateur rond positionné près du connecteur
d’alimentation. Il se représente comme suit:
A l’aide d’un tourne-vis plat ou d’une pièce de monnaie, le sélecteur peut être tourné dans la
position adéquate en veillaut que la flèche corresponde avec 110 ou 220, en fonction de la
valeur du circuit de courant local. (Voir tableau ci-dessous)
Circuit local ACPosition Sélecteur
110 ~ 120 VAC110
220 ~ 240 VAC220
Pour tout les modèles:
Pas de composants à entretenir à l’intérieur. Confiez toute réparation à un technicien qualifié.
Pour les modèles équipés de fusibles internes ou externes:
Afin d’éviter tout danger d’incendie, ne remplacer qu’avec le même type et la même valeur de fusible.
Pour tout les modèles avec une batterie au lithium interne:
Attention: Danger d’explosion si la batterie est incorrectement remplacée. Ne remplacez la batterie qu’avec le même modèle,
ou avec un modèle recommandé par le constructeur. Traitez les batteries usagées selon les instructions du fabricant, ou selon
les normes écologiques en viguer.
Installations und Sicherheitshinweise
Für Geräte ohne Netzschalter:
Die Netzsteckdose soll in de Nähe des Gerätes installiert und frei zugänglich sein.
Für Geräte mit 110 / 220V Spannungswähler:
Achtung: Bevor Sie dem Gerät Spann ung zuführen, muß der Spannungswähler entsprechend der Spannung des lokalen
Wechselspannungsnetzes eingestellt werden. Die falsche Stellung des Spannungswählers
kann eine Beschädigung des Gerätes und möglicherweise ein Feuer verursachen.
Der Spannungswähler ist ein runder Schalter in der Nähe der Netzeingangsbuchse mit
folgendem Aussehen:
Drehen Sie den Wähler mit einem normalen Schraubenzieher oder einer kleinen Münze so, daß
der Pfeil auf die 110 oder 220 zeigt, entsprechend der Spannung Ihr es lokalen Netzes wie hier
angezeigt:
Lokale NetzwechselspannungStellung des
110 ~ 120 V110
220 ~ 240 V220
Für alle Geräte:
Keine Wartung innerhalb des Gerätes notwendig. Reparaturen nur durch einen Fachmann!
Für Geräte mit interner oder externer Sicherung:
Für dauernden Schutz gegen Feuergefahr darf die Sicherung nur gegen eine andere gleichen Typs und gleicher Nennleistung
ausgewechselt werden.
Achtung: Explosionsgefahr bei falschem Batterieeinsatz. Batterie nur erstzen durch den gleichen oder entsprechenden Typ
wie vom Hersteller empfohlen. Entsorgung verbrauchter Batterien nur nach den Anweisungen des Herstellers.
Spannungswählers
Instalacion E Instrucciones de Seguridad
Modelos Sin Interruptor:
La conexión debe ser instalada cerca del equipo y debe ser accesible.
Modelos con Selector de Voltaje de 110/220V:
Precaución: Antes de operar esta unidad, el selector de voltaje debe instalarse de forma que corresponda a la linea de voltaje
local. Instalación inadecuada del selector de voltaje puede causar daño a la unidad y originar un incendio.
El selector de voltaje es un cambia vía redondo localizado cerca de la conexión electrica, como se
ve en el dibujo:
Use un destornillador comun o una moneda pequeña, mueva el selector a la posición correcta, de
forma que las flechas indiquen 110 o 220 de acuerdo con el voltaje local, como esta indicado a
continuación.
Voltaje Local A/CSelector de Voltaje
110 ~ 120 VAC110
220 ~ 240 VAC220
Para Todos Los Modelos:
Dentro de la unidad , no hay partes para reparar. Llame un tecnico calificado.
Modelos con Fusibles Internos o Externos:
Para prevenir un incendio, reemplace solo con el mismo tipo de fusible.
Precaución: Peligro de explosión si la batería es reemplacada incorrectamente. Reemplace solamente con la misma clase de
batería, o una equivalente recomendada por el fabricante. Deseche las baterías usadas de acuerdo con las instrucciones del
fabricante.
CE COMPLIANCE
All products exported to Europe by Inline, Inc. after January 1, 1997 have been
tested and found to comply with EU Council Directive 89/336/EEC. These
devices conform to the following standards:
EN50081-1 (1991), EN55022 (1987)
EN50082-1 (1992 and 1994), EN60950-92
Shielded interconnect cables must be employed with this equipment to
ensure compliance with the pertinent Electromagnetic Interference (EMI)
and Electromagnetic Compatibility (EMC) standards governing this device.
FCC COMPLIANCE
This device has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC rules. These limits are designed to
provide against harmful interference when equipment is operated in a
commercial environment. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of
equipment in a residential area is likely to cause harmful interference, in which
case the user will be required to correct the interference at their own expense.
DESCRIPTION
The IN3526vi is a six input and one output switcher designed for composite or S-Video signals. The IN3526vi
switcher routes one of several video source signals to an attached video recorder, monitor, projector or other
video equipment. Users may select the desired input channel using front panel buttons or via remote control.
The IN3526vi switcher offers easy operation and the following features:
♦100 MHz Bandwidth - allows the unit to be used with high resolution computer video signals as well as
NTSC/PAL/SECAM composite and S-Video signals
♦Vertical Interval Switching
♦Front Panel Channel Selection Controls and LED Indicators
♦Auto-sequencing of selected inputs in time intervals of 2.5 to 30 seconds
♦Contact Closure and RS-232 control port for remote selection of input channels
♦Cascading capability to create larger switching configurations
♦I/O port to power and control an IN3546R 6 in, 1 out Stereo Audio Switcher for audio follow video
applications.
COMPATIBILITY
The IN3526vi switcher will switch a wide variety of signals. While the unit was primarily designed for
Composite Video and S-Video (Y/C) signals, it can also switch high resolution computer video signals. The
IN3526vi shares the composite video and Luma (Y) channel, so it is not designed to handle both signal formats at
the same time. However, if your display device can switch between composite and S-Video, you can have some
inputs be composite and others be S-Video (although you will need to switch your display to view the proper
signal.)
1
INSTALLATION
This section offers step-by-step instructions for installing an IN3526vi switcher.
1.Connect all sources to the IN3526vi input connectors. Unused inputs do not need to be terminated.
2.Connect the IN3526vi output to the display device.
3.Connect remote control system if required.
4.Apply AC power to the unit.
5.Configure the unit for special applications (see Power-On Settings for more information.)
The IN3526vi switcher provides seven front panel buttons that may be used to select the desired input channel or
blank the output (no input selected.) Any time the unit is powered up, Input 1 is automatically selected. In order
to select a different input, press the corresponding input button and the appropriate green LED will light to
indicate the current active channel. Input channels may also be selected remotely by using an optional IN3590
wired remote or a control system (see Remote Control Operation for more details).
Blank
You can blank the output by pressing the BLANK button. If you press the button again, the previous input will
be selected. For example, let’s say you currently have Input 3 selected. If you press BLANK, the output will be
blanked. If you press BLANK again, Input 3 will be selected. You can also exit blank by selecting another input.
There are two options for selecting what will be sent to the output when BLANK is selected (see Power-On
Settings for more information):
1.Send nothing to the output.
2.Send sync to the output with no video (the sync is stripped off of Input 1.)
REMOTE CONTROL OPERATION
The IN3526vi switcher has an I/O port and an RS-232 port. The functions of these ports are described in this
section.
I/O Port
Channels can be selected through the remote port by providing contact closures between the appropriate pins.
The port also includes a +5V power supply and tally outputs, which can be used to power and control an
IN3546R audio switcher to provide audio follow video switching. Several contact closure type control devices
are available including:
IN3590 - An optional hard wired remote designed to work with IN3500 Series switchers.
Control System - many control systems are capable of providing contact closures.
In order to select a channel, the channel select pin (pins 1 - 6 and pin 8) must be connected to Common
(pin 7).
The contact closures may be momentary or continuous (latching). However, if the closure is latching, it
must be opened before another channel can be selected.
Example:To switch to Input Channel #4, apply a contact closure between Pin 4 and Pin 7.
Tally Output
The I/O port also provides tally outputs (pins 10 - 15) which may be used to trigger other devices (such
as the IN3546R), or provide feedback to a control system. When a channel is selected, either from the
front panel the I/O port or RS-232, the Tally Output for that channel is switched on. The Tally Output is
high when off, and goes low when switched on.
Control Port Pin Outs
The I/O port is a Female 15 Pin D connector with the following
pin outs:
Pin 1Select Input 1Pin 9+5 volts DC
Pin 2Select Input 2Pin 10 Tally output for Input 6
Pin 3Select Input 3Pin 11 Tally output for Input 5
Pin 4Select Input 4Pin 12 Tally output for Input 4
Pin 5Select Input 5Pin 13 Tally output for Input 3
Pin 6Select Input 6Pin 14 Tally output for Input 2
Pin 7CommonPin 15 Tally output for Input 1
Pin 8Select Blank
3
Using the IN3546R Stereo Audio Switcher
The IN3546R Stereo Audio Switcher may be attached to the IN3526vi via the REMOTE CONTROL
port. This provides a +5V power supply for the IN3546R Switcher and a control link. When the
IN3546R is attached to the control port using an IN9112 control link cable, the IN3546R will
automatically switch to the appropriate input channel, mirroring the input selected on the attached RGBS
switcher and adding audio-follow-video capability to the switcher.
The IN3526vi has an RS-232 ports which will accept serial commands from a control system,
computer serial port, or any other device capable of sending out serial ASCII commands at
compatible baud rates. All switching and most configuration and set-up parameters can be
controlled using RS-232 commands.
Communication Protocol:
The baud rate is selectable from 1200 to 19200 baud. Communication parameters are as follows:
1200 baud (Factory default setting)
No Parity
8 data bits
1 stop bit
Protocol Structure:
All commands sent to the unit must contain a leading character, the actual command, and an ending character.
Each command must be completely executed by the IN3526vi before it will accept a new command. When a
command is executed, the unit provides the response [OK] to indicate that the command was received and
executed. The response [ERR] indicates that there was a problem and the command was not executed.
The IN3526vi can recognize one of four sets of leading and ending characters, also called the Command Codes.
These are: [ ]{ }( )< >. The factory default for the Command Code is [ ]. The Command code can
only be changed via RS-232.
A complete command string consists of:
[The leading character
CH2The actual command.
]The ending character
Some sample commands are as follows:
[CH1]Select Input 1
[FP0]Disable the front panel operation
CONTROLLING MULTIPLE INLINE PRODUCTS
Many INLINE products such as the IN3526vi, PATHFINDER, and the IN1024/IN1224/IN1424 scan doublers
use similar communication protocol structures. By setting each unit to a different Command Code, up to four
INLINE products can be controlled independently by a single RS-232 serial control port (Note: An RS-232
distribution amplifier may be required.)
The IN3526vi has features that can be of benefit in some applications. These features can be enabled/disabled
via power-on or RS-232 (see those sections for more details.)
VERTICAL INTERVAL SWITCHING
Vertical interval switching can eliminate visual glitches when switching between different sources. This is
accomplished by waiting and switching the input during the vertical interval when no image is being displayed.
However, this is only useful when all input signals are genlocked together. Vertical interval switching can be
enabled or disabled via a power-on setting.
The IN3526vi uses the sync signal from input 1 to generate its sync reference. When a switch is made, the unit
waits for the next vertical sync pulse and then executes the switch. If a vertical sync pulse is not received within
approximately 71 msec (the time for about 4 fields), the switch is made.
SCAN MODE
When set to the Scan mode, the IN3526vi automatically switches the inputs at a certain interval. The inputs to be
selected can be set to all inputs or the first so many inputs (such as inputs 1, 2 and 3.) The time interval can be
set to approximately 2.5, 5, 7.5, 10, 15, 20 or 30 seconds, and is the same interval for all inputs.
5
When the auto-sequencing is active, none of the input buttons function except for the BLANK button. The autosequencing can be paused by pressing the BLANK button. While paused, you can select any input by pressing
the desired input button. To resume the auto-sequencing, simply press the BLANK button again.
MASTER / SLAVE SWITCHER
Large switching systems can be configured by cascading multiple IN3526vi switchers. Connect the output of the
first switcher to Input 1 of the next switcher and continue for as many switchers as you are cascading. Also,
connect the RS-232 Transmit pin of the first switcher to the RS-232 Receive pin of the next switcher and
continue for as many switchers as you are cascading.
Lastly, you need to configure all switchers except the last one as a Master switcher. When an IN3526vi is set-up
as a Master switcher, it transmits the RS-232 command [CH1] every time a switch occurs. This command causes
the next switcher to switch to channel 1, and this proceeds for all down-stream switchers so that the selected
channel is sent to the output. You can set an IN3526vi as a Master or Slave switcher via a Power-On Setting.
(Note: All switchers must be set for the same baud rate and command codes for cascading to operate properly.)
A Slave switcher does not send out any RS-232 command when a switch occurs. This is the default mode of
operation.
The power-on settings set the IN3526vi for specific applications. The installing technician will generally set
these settings when the unit is first installed and rarely changed. Power-On settings are selected by holding down
a specific front panel button while applying power to the unit and holding the button for approximately 3
seconds. These settings are not selectable when the unit is already powered up (except through RS-232
commands.) Once set, these settings are stored in the IN3526vi so that the unit will return to this mode on power
down/up.
Reset to Factory
Default Settings
Vertical Interval
Switching
Hold down the INPUT 1 button while applying power to the unit. This will reset
the unit to the following state:
Front Panel operation enabled
Vertical Interval switching off
Slave Switcher operation
1200 baud
“[ ]” Command codes
Normal switching operation (scanning off)
Blank sends nothing to the output
Hold down the INPUT 2 button while applying power to the unit. This will enable
vertical interval switching. The unit uses the sync signal from Input 1 to determine
when to switch. The vertical interval switching can be disabled by resetting the
unit to Factory Default.
Hold down the INPUT 3 button while applying power to the unit. The front panel
and contact closure remote control will be disables. The only way to switch the
unit is via RS-232 control. The front panel can be enable via RS-232 or by
resetting the unit to Factory Default.
Hold down the INPUT 4 button while applying power to the unit. This will set the
unit up as a master switcher (see Master/Slave Operation)
Hold down the INPUT 5 button while applying power to the unit. Hold the button
until the INPUT 6 LED turns on. Upon releasing the button, the BLANK and
INPUT 6 LEDs will begin to flash (if you have a signal on Input 6 it will flash on
your screen.) Press one of the input buttons to select the inputs to scan:
Hold down the BLANK button while applying power to the unit. Hold the button
until the INPUT 6 LED turns on. Upon releasing the button, the BLANK and
INPUT 6 LEDs will begin to flash (if you have a signal on Input 6 it will flash on
your screen.) . Press one of the input buttons to select the baud rate shown below.
Hold down the BLANK button while applying power to the unit. Hold the button
until the INPUT 6 LED turns on. Upon releasing the button, the BLANK and
INPUT 6 LEDs will begin to flash (if you have a signal on Input 6 it will flash on
your screen.) Press INPUT 6 or BLANK button to select the BLANK setup:
BLANKSend nothing to output when BLANK is selected
INPUT 6Send sync from INPUT 1 to output when BLANK is
ACI3Set baud rate to 1200, default settingOK
ACI4Set baud rate to 2400OK
ACI5Set baud rate to 4800OK
ACI6Set baud rate to 9600OK
ACI7Set baud rate to 19200OK
BLANK0Blank output (no input selected)OK or CH1
BLANK1Un-blank output (selects previous input)OK or CH1
CH0Blank output (same as pressing the front panel BLANK button)OK or CH1
CH1Select Input 1OK or CH1
CH2Select Input 2OK or CH1
CH3Select Input 3OK or CH1
CH4Select Input 4OK or CH1
CH5Select Input 5OK or CH1
CH6Select Input 6OK or CH1
CMDCD0Select "[" & "]"OK
CMDCD1Select "{" & "}"OK
CMDCD2Select "(" & ")"OK
CMDCD3Select "<" & ">"OK
SCAN0Disable scan modeOK
SCAN1Enable scan modeOK
SCANxConfigure scan to scan up to channel x where x = 2 to 6.OK
SCANTxSet scan time as follows:
x = 1: 2.5 seconds
x = 2: 5 seconds
x = 3: 7.5 seconds
x = 4: 10 seconds
x = 5: 15 seconds
x = 6: 20 seconds
x = 7: 30 seconds
FPEnable/Disable the front panel (toggle)OK
FP0Disable the front panelOK
FP1Enable the front panelOK
INF0Get the firmware versionIN3526VI V1.0
INF1Get the currently selected input0 to 6 (0 is for Blank)
* Command codes are not shown for clarification purposes.
OK
RS-232 SAMPLE COMMANDS
DescriptionCommandResponse
Switch to Input 2 (for a Slave switcher)[CH2][OK]
Switch to Input 2 (for a Master switcher)[CH2][CH1]
Get status of input selected[INF1][2]
Disable Front Panel operation[FP0][OK]
Change baud rate to 4800[ACI5][OK]
Change command codes to { }[CMDCD1]{OK}
The IN3526vi switcher employs a universal (switch mode) power supply which automatically adjusts to accept
input voltages worldwide. Input voltages can range between 90 and 260 VAC and the frequency may range from
47 to 63 Hz. The power supply entry module uses an IEC standard male connector for power connection. U.S
domestic units are shipped with a standard IEC female to Edison male power cable.
Changing Fuses
The power entry module includes a quick-change fuse holder. This holder contains the main fuse and a spare. If
the unit does not power-up, check the fuse. If the fuse is blown:
1.Remove the power cord from the unit.
2.Use a flat blade screwdriver to pull out the fuse holder.
3.Replace the blown fuse with the spare.
4.Replace the spare fuse with a new 125 mA, 250 V fuse.
5.Push the fuse holder back into the casing.
SPECIFICATIONS
IN3526vi Composite/S-Video Switcher
Inputs
Connector typeSix BNC female for composite video
Six 4 pin mini-din female for S-Video
Signal CompatibilityComposite Video, S-Video (Y/C), Monochrome with Sync
IN3546R Stereo Audio Switcher - Featuring 6 Inputs and 1 Output, the
IN3546R adds stereo audio -follow-video capabilities to IN3500 Series
Switchers. The IN3546R attaches to the IN3500 Series I/O port and receives
both power and switching commands from the control port.
IN3590 Wired Remote Control with 25' Long Cable. Allows Remote Channel
Selection for IN3500 Series Switchers
10
WARRANTY
♦
INLINE warrants the equipment it manufactures to be free from defects in materials and
workmanship.
♦
If equipment fails because of such defects and INLINE is notified within two (2) years from the
date of shipment, INLINE will, at its option, repair or replace the equipment at its plant, provided
that the equipment has not been subjected to mechanical, electrical, or other abuse or
modifications.
♦
Equipment that fails under conditions other than those covered will be repaired at the current
price of parts and labor in effect at the time of repair. Such repairs are warranted for ninety (90)
days from the day of re-shipment to the Buyer.
♦
This warranty is in lieu of all other warranties expressed or implied, including without
limitation, any implied warranty or merchantibility or fitness for any particular purpose,
all of which are expressly disclaimed.
The information in this manual has been carefully checked and is believed to be accurate. However, Inline, Inc. assumes
no responsibility for any inaccuracies that may be contained in this manual. In no event will Inline, Inc. be liable for
direct, indirect, special, incidental, or consequential damages resulting from any defect or omission in this manual, even if
advised of the possibility of such damages. The technical information contained herein regarding IN3526VI features and
specifications is subject to change without notice.