Extron Electronics IN3252HR Setup Guide

Setup GuideIN3252HR
This guide provides basic instructions for an experienced installer to set up and operate the Extron® IN3252HR Distribution Amplifier (DA).
C
Installation and service must be performed
Step 1 — Turn off the DA and input/output devices
Turn the input and output devices off and unplug their power cords. Verify that the DA is disconnected from the power source before proceeding.
Step 2 — Configure the jumpers
W
To ensure the best picture quality, inputs are DC coupled as a factory default. If the source device has a high DC offset that causes picture distortion and/or instability, change the jumpers to AC coupling. If a local monitor will be used, change the jumpers so inputs are unterminated (see figure 2).
If necessary, access the jumpers by following the steps below.
a. Remove the screws from the sides of the unit and slide the top cover off.
b. Identify the location of the jumpers (see figure 1) and configure them as needed
(see figure 2).
c. Replace the top cover and tighten the screws.
Input is terminated to 75 ohms (loop-through not used)*
Input is unterminated (high Z) (loop-through connected to a local monitor or another amplifier)
AC coupling
DC coupling*
*Factory default settings
Figure 2 – Jumper configuration table
Changes to internal jumpers must
be performed by authorized service personnel only. Take steps to prevent electrostatic discharge.
Configuration
Figure 1 – Board view of jumpers
J2 J3 J5 J1 J4 J6
Closed* Closed*
Open
Open
Closed*
Open
Closed*Closed* Closed*
Open
OpenOpenOpen
Closed
Step 3 — Attach input or loop-through cables
Connect an RGBHV, RGBS, RGsB, RsGsBs, component video, S-video, high resolution monochrome video, or composite video device to these BNC connectors (c). See figure 3 on the reverse side for information on how to cable the BNC connectors.
N When using a loop-through connected to a local monitor, be sure to keep the cable
shorter than 12 feet in order to prevent reflections.
Step 4 — Attach output cables
Connect up to two RGBHV, RGBS, RGsB, RsGsBs, component video, S-video, high resolution monochrome video, or composite video output devices, such as projectors or monitors, to these BNC connectors (b). See figure 3 on the reverse side for more information on how to cable the BNC connectors.
Setup Guide — IN3252HR (cont’d)
Power
RGsB,
Step 5 — Power on DA, input/output devices, and check for picture
Plug the external power supply cord into the DA (a) and turn on the input and output devices. The picture should appear. If not, ensure that all devices are plugged in and receiving power. Check cabling and make adjustments as needed.
N The BNCs for the output(s) and input
C
Step 6 — Adjust video gain and peaking
With an oscilloscope:
a. Feed a grayscale signal from an Extron VTG 300/400 to the input of the IN3252HR.
b. Remove the green output cable attached to the display device and connect it to the
c. Adjust the green gain control (d) to achieve 0.7 Vp-p for the white bar of the test pattern.
d. Repeat steps b and c for the red and blue channels.
e. Adjust the peaking by connecting the green output cable from the display device to
f. Plug the red, green, and blue cables back into the display device.
Without an oscilloscope:
a. Feed a grayscale signal from an Extron VTG 300/400 to the input of the IN3252HR.
b. Adjust the green gain control (d) until the picture from the display device appears to
c. Adjust the red and blue controls (d) until the grayscale picture appears to be gray only.
d. Adjust the peaking control (e) until the picture appears sharp with no visible smearing.
must be connected with an identical signal.
Always use a power supply supplied or
specified by Extron. Use of an unauthorized power supply voids all regulatory compliance certification and may cause damage to the supply and the end product. Unless otherwise stated, the AC/DC adapters are not suitable for use in air handling spaces or in wall cavities. The installation must always be in accordance with the applicable provisions of National Electrical Code ANSI/NFPA 70, article 75 and the Canadian Electrical Code part 1, section 16. The power supply shall not be permanently fixed to building structure or similar structure.
oscilloscope with 75 ohm termination.
the oscilloscope and adjusting the peaking control (e) until no overshooting or round corners appear on the test pattern.
have the correct brightness and contrast.
No color should be present.
Peaking
Gain controls
RGBS
5
control
4
RsGsBs, Component
Bottom view
S-video
Input
Composite video
connector
Outputs
2
RGBHV
R
G
B
H
V
1
Figure 3 – Connectors/controls and
BNC connection diagram
3
Step 7 — Mount the DA
If necessary, mount the DA. For mounting information, see the IN3252HR User’s Guide or refer to the bottom of the DA.
Extron USA - West
Headqua rters
+800.6 33.9876
Inside USA / Canada Only
+1.714.491.1500 +1.714.491.1517 FAX
Extron USA - East
+800.6 33.9876
Inside USA / Canada Only
+1.919.863.1794 +1.919.863.1797 FA X
Extron Euro pe
+800.3 987.6673
Inside Europe Only
+31.33.4 53.4040 +31.33.4 53.4050 F AX
© 2010 Extron Electronics. All rights reserved.
Extron Asia
+800.7 339.8766
Inside Asia Only
+65.63 83.440 0 +65.63 83.466 4 FAX
Extron Japa n
+81.3.35 11.7655 +81.3.35 11.7656 FAX
Extron Chi na
+400. 883.1568
Inside China Only
+86.21. 3760.1568 +86.21. 3760.1566 FA X
Extron Mid dle East
+971.4.2 991800 +971.4.2 991880 FA X
68-824-50
Rev. B
03 10
Loading...