Extron Electronics IN3218 User Manual

Operation Manual
High Resolution Video
Distribution Amplifier / Line Driver Series:
IN3212 - 1-In, 2-Out Distribution Amplifier IN3214 - 1-In, 4-Out Distribution Amplifier IN3218 - 1-In, 8-Out Distribution Amplifier
Installation and Safety Instructions
For Models without a Power Switch:
The socket outlet shall be installed near the equipment and shall be accessible.
For Models with 110 / 220V Power Selector:
The voltage selector is a round switch located next to the A/C power input connector which looks like this:
Using a straight slot screwdriver or small coin, rotate the selector to the correct position so that the
arrow lines up with 110 or 220 as appropriate for local power line voltage as indicated in the chart below:
Local A/C Voltage Voltage Selector Setting
110 ~ 120 VAC 110
220 ~ 240 VAC 220
For all Models:
No serviceable parts inside the unit. Refer service to a qualified technician.
For Models with Internal or External Fuses:
For continued protection against fire hazard, replace only with same type and rating of fuse.
For IN2001 / IN3234 / IN3236 / IN3502 / IN3504 / IN3506 / IN3562 / IN3564 / IN3566 / IN3572 / IN3574 / IN3576:
Caution: Double pole / neutral fusing.
For all Models with Integral Lithium Battery:
Caution: Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions.
Instructions d’installation et de sécurité
Pour les modèles sans interrupteur de courant:
La prise de courant d’alimentation sera installé près de l’équipement et sera accessible.
Pour les modèles avec un sélecteur d’alimentation 110V/220V:
Attention: Avant de connecter l’appareil au circuit d’alimentation, le sélecteur de courant doit être positionné sur la sélection appropriée correspondant au voltage du circuit de courant alternatif local. Une mauvaise sélection peut engendrer des dommages à l’appareil et créer un danger d’incendie.
Le sélecteur d’alimentation est un commutateur rond positionné près du connecteur d’alimentation. Il se représente comme suit:
A l’aide d’un tourne-vis plat ou d’une pièce de monnaie, le sélecteur peut être tourné dans la position adéquate en veillaut que la flèche corresponde avec 110 ou 220, en fonction de la valeur du circuit de courant local. (Voir tableau ci-dessous)
Circuit local AC Position Sélecteur
110 ~ 120 VAC 110
220 ~ 240 VAC 220
Pour tout les modèles:
Pas de composants à entretenir à l’intérieur. Confiez toute réparation à un technicien qualifié.
Pour les modèles équipés de fusibles internes ou externes:
Afin d’éviter tout danger d’incendie, ne remplacer qu’avec le même type et la même valeur de fusible.
Pour IN2001 / IN3234 / IN3236 / IN3502 / IN3504 / IN3506 / IN3562 / IN3564 / IN3566 / IN3572 / IN3574 / IN3576:
Attention: Double pôle / fusible au neutre.
Pour tout les modèles avec une batterie au lithium interne:
Attention: Danger d’explosion si la batterie est incorrectement remplacée. Ne remplacez la batterie qu’avec le même modèle, ou avec un modèle recommandé par le constructeur. Traitez les batteries usagées selon les instructions du fabricant, ou selon les normes écologiques en viguer.
Installations und Sicherheitshinweise
Für Geräte ohne Netzschalter:
Die Netzsteckdose soll in de Nähe des Gerätes installiert und frei zugänglich sein.
Für Geräte mit 110 / 220V Spannungswähler:
Achtung: Bevor Sie dem Gerät Spann ung zuführen, muß der Spannungswähler entsprechend der Spannung des lokalen Wechselspannungsnetzes eingestellt werden. Die falsche Stellung des Spannungswählers kann eine Beschädigung des Gerätes und möglicherweise ein Feuer verursachen.
Der Spannungswähler ist ein runder Schalter in der Nähe der Netzeingangsbuchse mit folgendem Aussehen:
Drehen Sie den Wähler mit einem normalen Schraubenzieher oder einer kleinen Münze so, daß der Pfeil auf die 110 oder 220 zeigt, entsprechend der Spannung Ihr es lokalen Netzes wie hier angezeigt:
Lokale Netzwechselspannung Stellung des
Spannungswählers
110 ~ 120 V 110
220 ~ 240 V 220
Für alle Geräte:
Keine Wartung innerhalb des Gerätes notwendig. Reparaturen nur durch einen Fachmann!
Für Geräte mit interner oder externer Sicherung:
Für dauernden Schutz gegen Feuergefahr darf die Sicherung nur gegen eine andere gleichen Typs und gleicher Nennleistung ausgewechselt werden.
Für IN2001 / IN3234 / IN3236 / IN3502 / IN3504 / IN3506 / IN3562 / IN3564 / IN3566 / IN3572 / IN3574 / IN3576:
Achtung: Allpolige Absicherung
Für alle Geräte mit eingebauter Lithium Batterie:
Achtung: Explosionsgefahr bei falschem Batterieeinsatz. Batterie nur erstzen durch den gleichen oder entsprechenden Typ wie vom Hersteller empfohlen. Entsorgung verbrauchter Batterien nur nach den Anweisungen des Herstellers.
Instalacion E Instrucciones de Seguridad
Modelos Sin Interruptor:
La conexión debe ser instalada cerca del equipo y debe ser accesible.
Modelos con Selector de Voltaje de 110/220V:
Precaución: Antes de operar esta unidad, el selector de voltaje debe instalarse de forma que corresponda a la linea de voltaje local. Instalación inadecuada del selector de voltaje puede causar daño a la unidad y originar un incendio.
El selector de voltaje es un cambiavía redondo localizado cerca de la conexión electrica, como se ve en el dibujo:
Use un destornillador comun o una moneda pequeña, mueva el selector a la posición correcta, de forma que las flechas indiquen 110 o 220 de acuerdo con el voltaje local, como esta indicado a continuación.
Voltaje Local A/C Selector de Voltaje
110 ~ 120 VAC 110
220 ~ 240 VAC 220
Para Todos Los Modelos:
Dentro de la unidad , no hay partes para reparar. Llame un tecnico calificado.
Modelos con Fusibles Internos o Externos:
Para prevenir un incendio, reemplace solo con el mismo tipo de fusible.
Modelos IN2001 / IN3234 / IN3236 / IN3502 / IN3504 / IN3506 / IN3562 / IN3564 / IN3566 / IN3572 / IN3574 / IN3576:
Precaución: Double Polo / Fusible Neutral.
Modelos con Bateria de Lithiun Interna:
Precaución: Peligro de explosión si la batería es reemplacada incorrectamente. Reemplace solamente con la misma clase de batería, o una equivalente recomendada por el fabricante. Deseche las baterías usadas de acuerdo con las instrucciones del fabricante.
CE COMPLIANCE
All products exported to Europe by Inline, Inc. after January 1, 1997 have been tested and found to comply with EU Council Directive 89/336/EEC. These devices conform to the following standards:
EN50081-1 (1991), EN55022 (1987) EN50082-1 (1992 and 1994), EN60950-92
Shielded interconnect cables must be employed with this equipment to ensure compliance with the pertinent Electromagnetic Interference (EMI) and Electromagnetic Compatibility (EMC) standards governing this device.
FCC COMPLIANCE
This device has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide against harmful interference when equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at their own expense.
DESCRIPTION
The IN3212, IN3214 and IN3218 are high performance video distribution amplifiers with gain and peaking controls.
The IN3212 is a 1 in 2 out composite video distribution amplifier / line driver.
The IN3214 is a 1 in 4 out video distribution amplifier / line driver.
The IN3218 is a 1 in 8 out video distribution amplifier / line driver.
All three models are very similar in function, features, and operation with only a few differences as detailed in the chart below:
1
Feature
Number of Outputs­Regular Mode Number of Outputs­Split Mode Gain Controls 1 2 4 Sharpness Controls 1 2 4
These units feature a compact design, which allows them to be installed in a very small space, and offer 300 MHz bandwidth performance. The gain and peaking controls can be adjusted to compensate for signal loss due to long cable runs, and may be used to drive a signal as far as 1000 feet, depending on the signal resolution and cable. Multiple units can also be looped together to provide additional outputs.
IN3212
2 4 8
N/A (2) 1 X 2 (2) 1 X 4
IN3214 IN3218
PRODUCT FEATURES
2, 4 or 8 Outputs – Feed the signal from one video source to two, four or eight monitors, projectors,
VCRs, or other output devices.
Gain Controls – Boost the signal voltage to drive long cable runs.
Peaking Controls – Enhance image by increasing clarity and visibility of fine details.
300 MHz Video Bandwidth
BNC input and output connectors
Wide Compatibility – Compatible with composite video signals (NTSC / PAL / SECAM) and high
resolution monochrome video signals.
Split Mode Operation – By changing an internal jumper, the IN3214 or IN3218 can be set for split
mode where they function as two independent Distribution Amplifiers:
- IN3214: (2) 1x2 Distribution Amplifiers
- IN3218: (2) 1x4 Distribution Amplifiers
Loop Output – The loop output connector provides a passive loop-through signal. This can be
looped through to additional amplifiers to create a larger DA system or to drive a local monitor.
Metal case enclosure and optional mounting brackets
2
COMPATIBILITY
The IN3212 / IN3214 / IN3218 offer extremely wide bandpass characteristics and are compatible with hi-resolution monochrome signals at virtually any resolution and refresh rate, as well as with low resolution color composite video signals such as NTSC, PAL, or SECAM.
INSTALLATION
1. If operating the IN3214 / IN3218 in unified mode without loop output (factory default,) begin with step 2. If operating the IN3214 / IN3218 in split mode or with the loop output
connector, please refer to INTERNAL CONTROLS section on page 3 and set jumper as appropriate.
2. Connect the video signal from the source to the IN3212 / IN3214 / IN3218 input.
3. Connect the output(s) to the display device(s) or other equipment.
4. Apply power to the unit (9VDC, 500 mA external adapter.)
5. Adjust gain and peaking controls as needed (see GAIN AND PEAKING CONTROLS section for details.)
OPERATION
The IN3212 / IN3214 / IN3218 are designed to distribute/extend video signals. These units have gain and peaking controls which can compensate for cable losses, extending a video signal as far as 1000 feet without any degradation of the signal. Actual drive distance depends on the resolution of the signal and the quality of the cable used. Typically, low resolution video signals (15KHz) can be sent 600-800 feet, and high resolution signals (30 KHz and above) can be sent 200-400 feet.
Regular Mode / Split Mode Operation
The IN3214 / IN3218 can function in two different amplification modes, regular mode or split mode as described below: Regular Mode (factory default): The unit operates as a single amplifier. The input signal drives all four or eight outputs. The second connector adjacent to the input may be used as a loop output if the internal jumpers are set properly.
Split Mode: The unit operates as two independent amplifiers. Each input drives two outputs (IN3214) or four outputs (IN3218). In split mode operation, the IN3214 / IN3218 can be used to amplify two separate composite video signals or to amplify a single S-Video signal, with the Y (luminance) signal connected to one input connector and the C (chrominance) signal connected to the second input connector.
Please note that in split mode there is no loop output connector since the second connector is used as an input. However, if a loop output is required, the inputs can be set to High Z termination using the internal jumpers and a BNC "T" can be used to split the signal at the input.
IN3212 / IN3214 / IN3218 OPERATION MANUAL - REV. 1 10/25/97 ©1997 - INLINE, INC.
LOOP OUTPUT CONNECTOR
The loop output connector provides a passive loop-through signal. This can be looped through to additional amplifiers to create a larger DA system or to drive a local monitor. In order to use the loop output, the Input termination jumper (internal) must be set to High Z (unterminated). The location of the input termination jumper is indicated on pages 4-6.
GAIN AND PEAKING CONTROLS
The gain controls can be used to compensate for video signal voltage losses. Peaking may be used to reboost high frequency components that have been attenuated by long cable runs. The peaking control employs an equalization circuit, introducing an adjustable high frequency peak.
Gain Control
The gain control is used to increase/decrease the contrast of an image by adjusting the amplitude of the video signal. The control has a range of 0.7 to 1.4. Using the IN9333 adjustment tool, gently turn the control clockwise to increase the video gain, and counter-clockwise to decrease the gain.
Peaking Control
The peaking control enhances image detail and sharpness by boosting high frequencies. Using the IN9333 adjustment tool, gently turn the control clockwise to increase peaking, and counter-clockwise to decrease the peaking.
3
INTERNAL CONTROLS
CAUTION: Adjustment of the IN3212 / IN3214 / IN3218 internal controls must only be carried out by qualified technicians. Care must be taken to avoid static shock to the internal components.
The IN3212 / IN3214 / IN3218 have internal jumpers which can be accessed using the following procedure:
1. Remove the screws from the sides of the unit.
2. (For IN3212 / IN3214 only) Remove hex-nuts from the output BNC connectors.
3. Slide the top cover off.
4. Identify location of jumpers using the diagrams on pages 4-6 and adjust as needed.
5. Replace top cover and tighten the BNC hex-nuts (if applicable) and the side screws.
© 1997 - INLINE, INC. IN3212 / IN3214 / IN3218 OPERATION MANUAL - REV. 1 10/25/97
4
IN3212 Internal Jumpers
Jumper Functions
J3
J4 & J5
*Closed Open *Always Closed Jumpers Must Always Be Closed
Table of Operating Modes
*Input is Terminated to 75ohms (Loop Through Not Used) Input is Unterminated (High Z) (Loop Through Connected to a Local Monitor or Another Amplifier )
*Factory Default Settings
Input Terminated into 75 ohms Input Unterminated (High Z)
J3 J4 J5
Closed Closed Closed
Open Closed Closed
IN3212 / IN3214 / IN3218 OPERATION MANUAL - REV. 1 10/25/97 ©1997 - INLINE, INC.
IN3214 Internal Jumpers
5
Jumper Functions
J3
J4 & J5
J2
*Closed Open *Closed Open Closed *Open
Input Terminated into 75 ohms Input Unterminated (High Z) Unit Operates as One 1 x 4 Distribution Amplifier Unit Operates as Two 1 x 2 Distribution Amplifiers Input #2 Terminated into 75 ohms Input #2 Unterminated (High Z)
Table of Operating Modes
*Normal Mode - Unit Operates as a Single 1 x 4 Distribution Amplifier Input is Terminated (no loop through) Normal Mode - Unit Operates as a Single 1 x 4 Distribution Amplifier Input is Unterminated (Using Loop Output) Split Mode - Unit Operates as Two Independent 1 x 2 Distribution Amplifiers Input 1 & Input 2 Terminated into 75 ohms Split Mode - Unit Operates as Two Independent 1 x 2 Distribution Amplifiers Input 1 & Input 2 Unterminated (High Z) *Factory Default Settings
J2 J3 J4 J5
Open Closed Closed Closed
Open Open Closed Closed
Closed Closed Open Open
Open Open Open Open
© 1997 - INLINE, INC. IN3212 / IN3214 / IN3218 OPERATION MANUAL - REV. 1 10/25/97
6
IN3218 Internal Jumpers
Jumper Functions
J2
J1 & J3
J9
J4 / J5 / J6 / J7
*Closed Open *Closed Open Closed *Open Closed *Open
Input Terminated into 75 ohms Input Unterminated (High Z) Unit Operates as One 1 x 8 Distribution Amplifier Unit Operates as Two 1 x 4 Distribution Amplifiers Input #2 Terminated into 75 ohms Input #2 Unterminated (High Z) Outputs DC Coupled Outputs AC Coupled
Table of Operating Modes
*Normal Mode - Unit Operates as a Single 1 x 4 Distribution Amplifier Input is Terminated (No Loop-Through) Normal Mode - Unit Operates as a Single 1 x 4 Distribution Amplifier Input is Unterminated (Using Loop Output) Split Mode - Unit Operates as Two Independent 1 x 2 Distribution Amplifiers Input 1 & Input 2 Terminated into 75 ohms Split Mode - Unit Operates as Two Independent 1 x 2 Distribution Amplifiers Input 1 & Input 2 Unterminated (High Z) *Factory Default Settings
J2 J3 J1 J9
Closed Closed Closed Open
Open Closed Closed Open
Closed Open Open Closed
Open Open Open Open
IN3212 / IN3214 / IN3218 OPERATION MANUAL - REV. 1 10/25/97 ©1997 - INLINE, INC.
SPECIFICATIONS
7
IN3212
IN3214 IN3218
Inputs
Input 1 (1) BNC for composite video signals
Termination: 75O or High Z
Signal Analog Video, 1.5 Vp-p max. Loop Out / Input 2 (1) BNC
Termination: 75O or High Z
Output
Connectors 2 BNC female 4 BNC female 8 BNC female Impedance 75O
Controls
Gain Range 0.7 (30% decrease) to 1.4 (40% increase) Peaking
Optimized for NTSC/PAL/SECAM Signals
General
Bandwidth 300 MHz @ -3dB Internal Jumpers
(2) Input Termination
(2) Normal / Split Mode
(4) AC/DC Coupling (IN3218 only)
Power
Voltage 9 VDC
500 mA external adapter included
Power Consumption Dimensions
Height x Width x Depth
Weight
Regulatory Approvals
4” x 5.6” x 1.25” /
10.2cm x 14.2cm x 3.2cm
Product weight: 0.75 lbs. / 0.35 Kg
Shipping weight: 2 lbs. / 1Kg
UL1950, CAN/CSA-22.2 No.950, Third Edition
CE: EN5502 (1987), EN50081-1 (1991),
EN50082-1 (1992 and 1994), EN0950-92
4” x 5” x 1.6” /
10.2cm x 12.7cm x 4cm
Parts Included
IN9204 9 VDC 500 mA Power Supply
IN9333 Gain / Peaking Adjustment Tool
Operation Manual
Optional Accessories
Mounting Brackets
© 1997 - INLINE, INC. IN3212 / IN3214 / IN3218 OPERATION MANUAL - REV. 1 10/25/97
IN9127 (for IN3214/IN3218); IN9128 (for IN3218).
8
TROUBLESHOOTING
Problem: There is no image on the output of the IN3212 / IN3214 / IN3218. Suggestions:
q Make sure the power supply is plugged in and that the input and output cables are
connected properly.
q Bypass the IN3212 / IN3214 / IN3218 by connecting the input and output cables
with a BNC barrel connector to ensure there is a video signal present.
Problem: The output image is too dark. Suggestion:
q First make sure the display device contrast and brightness controls are set properly.
Then increase the appropriate IN3212 / IN3214 / IN3218 gain control until the desired image is achieved.
Problem: The output image is too bright or the picture blooms. Suggestions:
q First make sure the display device contrast and brightness controls are set properly.
Then decrease the appropriate IN3212 / IN3214 / IN3218 output gain control until the desired image is achieved.
q The input termination may be set to High Z. Check the termination jumper settings
(see pages 4-6.)
Problem: The output image is not sharp enough. Vertical lines are very thin. Suggestions:
q Make sure you are using the appropriate video cable for your signal type. When
dealing with high resolution video signals, a high quality coaxial cable must be used for long distance cable runs (50 ft. or more). IN7100 or IN7200 series cables are recommended for very long cable runs.
q Increase the peaking control of the IN3212 / IN3214 / IN3218 to compensate for
high frequency losses.
Problem: The loop output is not working. Suggestion:
q The input termination for input 1 must be set to High Z. Set the internal jumpers as
shown on pages 4-6.
IN3212 / IN3214 / IN3218 OPERATION MANUAL - REV. 1 10/25/97 ©1997 - INLINE, INC.
WARRANTY
Inline warrants the equipment it manufactures to be free from defects in materials and workmanship.
If equipment fails because of such defects and INLINE is notified within two (2) years from the date of shipment, INLINE will, at its option, repair or replace the equipment at its plant, provided that the equipment has not been subjected to mechanical, electrical, or other abuse or modifications.
Equipment that fails under conditions other than those covered will be repaired at the current price of parts and labor in effect at the time of repair. Such repairs are warranted for ninety (90) days from the day of re-shipment to the Buyer.
This warranty is in lieu of all other warranties expressed or implied, including without limitation, any implied warranty or merchantibility or fitness for any particular purpose, all of which are expressly disclaimed.
9
The information in this manual has been carefully checked and is believed to be accurate. However, Inline, Inc. assumes no responsibility for any inaccuracies that may be contained in this manual. In no event will Inline, Inc. be liable for direct, indirect, special, incidental, or consequential damages resulting from any defect or omission in this manual, even if advised of the possibility of such damages. The technical information contained herein regarding IN3212 / IN3214 / IN3218 features and specifications is subject to change without notice.
All trademarks and brands are property of their respective companies. All Rights Reserved © Copyright 1997
©
(800) 882-7117 ♦ (714) 450-1800 ♦ FAX (714) 450-1850
INLINE, INC. ♦ 810 West Taft ♦ Orange, CA 92865
www.inlineinc.com
© 1997 - INLINE, INC. IN3212 / IN3214 / IN3218 OPERATION MANUAL - REV. 1 10/25/97
Loading...