Extron Electronics Hi Res ECL Buffer User Manual

Hi Res ECL Buffer DIP Switch Settings
Verify that the Hi Res ECL Buffer internal DIP Switch settings are correct for your system application. To open the plastic housing, insert the flat blade of a screw-driver, or similar object, into the slot recess at either end of the enclosure and gently pry the halves apart. Once opened, orient the assembly so that the internal DIP switches match the orientation in the diagram below. Use the diagram and the table beneath it to verify or change the settings as required. An incorrect setting will not cause damage to the Hi Res ECL Buffer or the system being interfaced. Once settings are complete, snap the halves of the enclosure together.
User's Guide
SW1 SW2 SW3 SW4 SW5
Workstation 1231231231212
MBC - SUN/APOLLO ON ON X OFF X X ON OFF X OFF ON OFF ON MBC - WANG WIIS ON ON X OFF X X ON OFF X ON OFF OFF ON IBM 3472/77 MONO ON OFF X ON OFF ON ON OFF X OFF ON OFF ON IBM 3472/77 COLOR OFF ON X ON ON X OFF ON ON OFF ON OFF ON MBC - SIGMA LVIEW ON OFF ON ON OFF ON ON OFF X OFF ON OFF ON MBC - NCD19 MONO ON ON X OFF X X ON OFF X ON OFF OFF ON
X = No Effect
1230 South Lewis Street Anaheim, CA 92805 (714) 491-1500 FAX (714) 491-1517
U.S.A.
EXTRON ELECTRONICS, EUROPE
Beeldschermweg 6C 3821 AH Amersfoort +31-33-453-4040 FAX +31-33-453-4050
The Netherlands
EXTRON ELECTRONICS, ASIA
41B Kreta Ayer Road Singapore 089003 +65-226-0015 FAX +65-226-0019
Singapore
79-09
68-057-01 Rev. G3
Hi Res ECL Buffer
P/N 26-177-01
Hi Res ECL Buffer Operation and Installation Hi Res ECL Buffer Operation and Installation
Hi Res ECL Buffer Operation
The Extron Hi Res ECL Buffer is for use when interfacing high resolution ECL signals from graphic workstations or PC's to a compatible graphics projector or monitor. The buffer is used in combination with any one of the RGB interfaces listed below to provide a buffered signal to the interface while maintaining its resolution and bandwidth.
The Hi Res ECL Buffer must be used in combination with a Monitor Breakout Cable (MBC) corresponding to the ECL signal from the original source PC or workstation. For example, when interfacing a Sun Monochrome Workstation, use the Hi Res Buffer along with an MBC Sun/Apollo cable (P/N 26-198-01).
Power is supplied to the Hi Res ECL Buffer, through the cable, from an MBC power jack located on the RGB Interface device.
The following Extron interfaces are compatible with the Hi Res ECL Buffer: RGB 106E RGB 108 RGB 108 PLUS
RGB 116 RGB 118 RGB 118 PLUS RGB 120 RGB 200 RGB 202 RGB 202 PLUS RGB 202xi RGB 202 VS2 RGB 202 VS SL2 RGB 202 VTG RGB 300
Installation Instructions
Prior to installing the Hi Res ECL Buffer, verify its internal DIP switch settings using the procedure on the back page.
Required equipment for installation is:
Hi Res ECL Buffer (P/N 26-177-01)
RGB Interface (See list of compatible interfaces on facing page)
MBC cable compatible with computer being interfaced
1. Turn system power OFF. (Use diagram on facing page with instructions below.)
2. Disconnect the local workstation monitor at the system.
3. Connect the MBC cable labeled COMPUTER (3A) to the computer system's video output port. Connect the cable connector labeled MONITOR (3B) to the system's local workstation monitor (3C). If the MBC cable is the type with a molded dual connector at one end (as pictured below), connect the system cable to one side and the monitor cable to the other side of the dual connector.
4. Connect the MBC cable 9 pin female connector labeled INTERFACE to the Hi Res ECL Buffer input connector located on the front panel (4).
5. Connect the Hi Res ECL Buffer cable 9 pin female connector to the Analog/ECL input of the interface being used (5).
6. Plug the Hi Res ECL Buffer power connector (6) into the Interface MBC power jack which is located on the rear panel of the Interface (front panel of RGB 118 and RGB 118 PLUS).
NOTE: To activate power to the Hi Res ECL Buffer, an RGB 106E, 108, 200 or 202
must have dip switches 1 & 8 in the ON position. An RGB 108 PLUS or 202 PLUS must have dip switch 3 in the ON position.
7. Turn power ON and check for proper operation.
8. A Blue Enhance adjustment is available on the bottom of the Hi Res ECL Buffer enclosure (See picture to the right). This adjustment allows tweaking a blue text display to an easier to read blue-green color.