The Extron HDP1014K is a compact, active HDMI to DisplayPort converter for signals
up to 4K 30 Hz @ 4:4:4. It converts HDMI signals for connection to DisplayPort displays
or peripherals. Incoming HDMI signals are equalized up to 15 feet (4 meters) at the input
to compensate for signal loss. The HDP1014K features EDID Minder®, which maintains
continuous EDID communication with connected devices and ensures that the HDMI
source powers up properly and maintains correct video output. Audio information is
passed between source and display.
The HDP1014K supports digital video resolutions of up to 4K/30 at 4:4:4 (or 10.2 Gbps)
and is DisplayPort 1.2, HDMI 1.4, and HDCP 1.4 compliant.
FCC Class A Notice
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part15 of the
FCC rules. The ClassA limits provide reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used
in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment
in a residential area is likely to cause interference. This interference must be corrected at the expense of the user.
NOTES:
• This unit was tested with shielded I/O cables on the peripheral devices. Shielded cables must be used to ensure
compliance with FCC emissions limits.
• For more information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related
topics, see the Extron Safety and Regulatory Compliance Guide on the Extron website.
Specifications
Product specifications are available on the Extron website, www.extron.com.
Features
• Provides connectivity between HDMI sources and DisplayPort displays and peripherals.
• Supports computer and video resolutions up to 4K/30 @ 4:4:4 with data rates up to 10.2 Gbps.
• Supported HDMI specification features include data rates up to 10.2 Gbps, 3D, Lip Sync, and HD lossless audio
formats.
• Equalizes incoming HDMI signals up to 15 feet (4 meters) to compensate for signal loss due to low quality cables or
marginal sources.
• EDID Minder automatically manages EDID communication between connected devices — EDID Minder ensures that all
sources power up properly and reliably output content for display.
• Selectable resolutions and refresh rates — Pre-stored EDID is communicated to the source based on a user-selected
resolution and refresh rate.
• EDID capture mode — When connected to a display, the HDP1014K offers the option of capturing and then storing EDID
information from the display device.
• Complies with HDMI and VESA Interoperability Guidelines.
• HDCP 1.4 compliant — The HDP 101 4K ensures display of content-protected media and interoperability with earlier
versions of HDCP-compliant devices.
• LED indicator for signal presence and power — Provides visual indication of system status for real-time feedback and
monitoring of key performance parameters.
• Front panel USB configuration port — Provides convenient access for setup, conguration, and rmware updates.
• Easy setup and commissioning with Extron PCS – Product Configuration Software — Conveniently congure multiple
products using a single software application.
• Compact 1 inch (2.5 cm) high, 2.2 inch (5.6 cm) wide enclosure for discreet placement and mounting in space-
constrained environments — Includes fabric hook and loop tape for easy installation in any application.
1
HDP 101 4K • User Guide (Continued)
• Includes LockIt® HDMI cable lacing brackets.
• Supports LPCM audio.
• Highly reliable, energy-efficient external universal power supply included — Provides worldwide power compatibility,
with high demonstrated reliability and low power consumption for reduced operating costs.
Application Diagram
PC
Figure 1. HDP1014K Application
Laptop
HDMI
Blu-ray Disc
POWER
SIG
12V
--A MAX
Extron
HDP 101 4K
HDMI to DisplayPort
Converter
HDMI
HDMI
DP OUT
DisplayPort
4K Display
Mounting
Use the included hook-and-loop tape to attach the HDP1014K to the application surface.
2
HDP 101 4K • User Guide (Continued)
BD
Smooth
Power Supply Output Cord
A
Cabling
A
L
CONFIG
HDMI IN
Figure 2. HDP1014K Panels
Config port — Connect a host computer to this mini-B USB port to configure the HDP1014K.
A
HDMI input —Connect an HDMI source device to the HDMI input.
B
NOTE: Extron recommends using HDMI Pro Series cables for 300 Mhz pixel clock (4K/UHD) signals.
Power inlet — Wire the external 12 VDC power supply as shown below, and connect it to the two-pole captive screw Power
C
connector.
SECTION A–A
Figure 3. Wiring the Power Connector
ATTENTION:
• The length of the exposed wires in the stripping process is critical. The ideal length is 3/16 inches (5 mm). Any
longer and the exposed wires may touch, causing a short circuit between them. Any shorter and the wires can be
easily pulled out even if tightly fastened by the captive screws.
• La longueur des câbles exposés est primordiale lorsque l’on entreprend de les dénuder. La longueur idéale est de
5mm (3/16inches). S’ils sont un peu PLUS longs, les câbles exposés pourraient se toucher et provoquer un court
circuit. S’ils sont un peu PLUS courts, ils pourraient sortir, même s’ils sont attachés par les vis captives.
• Always use a power supply supplied by or specied by Extron. Use of an unauthorized power supply voids all
regulatory compliance certication and may cause damage to the supply and the end product.
• Utilisez toujours une source d’alimentation fournie par Extron. L’utilisation d’une source d’alimentation non
autorisée annule toute conformité réglementaire et peut endommager la source d’alimentation ainsi que l’unité.
• If not provided with a power supply, this product is intended for use with a UL Listed power source marked “Class
2” or “LPS” rated 12 VDC, 0.5 A minimum.
• Si le produit n’est pas fourni avec une source d’alimentation, il doit être utilisé avec une source d’alimentation
certiée UL de classe 2 ou LPS avec une tension nominale de 12 Vcc, 0.5 A minimum.
• Unless otherwise stated, the AC/DC adapters are not suitable for use in air handling spaces or in wall cavities.
The power supply is to be located within the same vicinity as the Extron AV processing equipment in an ordinary
location, Pollution Degree 2, secured to the equipment rack within the dedicated closet, podium, or desk.
• Sauf mention contraire, les adaptateurs AC/DC ne sont pas appropriés pour une utilisation dans les espaces
d’aération ou dans les cavités murales. La source d’alimentation doit être située à proximité de l’équipement de
traitement audiovisuel dans un endroit ordinaire, avec un degré2 de pollution, xé à un équipement de rack à
l’intérieur d’un placard, d’une estrade, ou d’un bureau.
• The installation must always be in accordance with the applicable provisions of National Electrical Code ANSI/
NFPA 70, article 725 and the Canadian Electrical Code part 1, section 16. The power supply shall not be
permanently xed to building structure or similar structure.
• Cette installation doit toujours être en accord avec les mesures qui s’applique au National Electrical Code ANSI/
NFPA70, article725, et au Canadian Electrical Code, partie1, section16. La source d’alimentation ne devra pas
être xée de façon permanente à une structure de bâtiment ou à une structure similaire.
HDP 101 4K
Ridges
C
POWER
12V
0.1A MAX
A
SIG
DP OUT
3/16"
(5 mm) Max.
Config port
A
HDMI input
B
Power inlet
C
DP output
D
DP output — Connect a DisplayPort device to the DP output.
D
3
HDP 101 4K • User Guide (Continued)
DP OUT
SIG
POWER
12V
0.1A MAX
HDP 101 4K
L
CONFIG
HDMI IN
ABD
P
C
Space
LED Indicators
A
L
CONFIG
HDMI IN
HDP 101 4K
D
POWER
12V
0.1A MAX
B
SIG
DP OUT
Power and signal LED (front) — Lights amber to indicate power,
A
and lights green to indicate HDMI signal presence.
Output signal LED (rear) — Lights green to indicate signal
B
presence on the DisplayPort output.
Figure 4. HDP1014K LED Indicators
Firmware Upgrades
The HDP1014K rmware can be upgraded via Product Conguration Software (PCS) or the Extron Firmware Loader program
(available at www.extron.com).
SIS Commands
The HDP1014K can be congured with specic SIS commands via a USB connection. Use the Extron DataViewer utility or
a control system to send and receive SIS commands. SIS commands consist of one or more characters per eld. No special
characters are required to begin or end a command sequence. When the HDP1014K recognizes a valid command, it executes
the command and sends a response to the host device. All responses from the receiver to the host end the character string with a
carriage return and a line feed (CR/LF = ]). A string is one or more characters.
When the HDP1014K is rst switched on, it sends the message:
When the HDP1014K receives a valid SIS command, it executes the command and sends a response to the host device. If the
HDP1014K is unable to execute the command because the command is invalid or contains invalid parameters, it returns the
following error responses to the host:
• E10 – Invalid command
• E13 – Invalid parameter
Using the Command and Response Table
The Command and Response Table for SIS Commands starting on page6 lists the following:
• Valid ASCII command codes
• The device response to the host
• A description of the command function, or the results of executing the command
The ASCII to hexadecimal conversion table below is for use with the command and response table:
ASCII to Hex Conversion Table
•
4
HDP 101 4K • User Guide (Continued)
Command and Response Table for SIS Commands
=
Carriage return and line feed (LF)
]
=
Carriage return with no line feed
}
=
|
Pipe (can be used interchangeably with the } character).
=
Space
•
Escape key
=
E
=
W
Can be used interchangeably with the Echaracter.
X! =
Status
0 = Off/low/undetected
1 = On/high/detected
EDID: 1 to 3 (see table)
X$ =
X$
1Input 1 (Store) SlotHDMI 1080p 60 Hz 2-ChDefault
2Output
3User Loaded SlotManually populated via PCS
Verbose mode:
X% =
0 = Clear/none
1 = Verbose mode (default)
2 = Tagged responses for queries
3 = Verbose mode and tagged responses for queries
HDP1014K part number 60-1739-01
X^ =
Text string of up to 24 alphanumeric characters and hyphen (-). No spaces allowed, and no distinction between upper and
X& =
lower case. First character must be a letter and the last must not be a hyphen. Default is “HDP-101-4K”.
SlotDefault EDIDDetails
NOTE: Upper- and lowercase characters can be used interchangeably in the command field unless otherwise specified.
5
HDP 101 4K • User Guide (Continued)
Command and Response Table for SIS Commands
CommandASCII Command
(Host to Device)
Signal Status
Input and output signal status
E0LS}X!•X!]
EDID Assignment
Assign EDID slot to input
View EDID assignment
EA X$
EDID}Edid A
EA
EDID}X$]
Verbose Mode
Set verbose mode
View verbose mode
EX%
CV}Vrb
ECV}X%]
Unit Name
Set the unit name
Set unit name to factory default
View unit name
EX&
CN}Ipn
E
CN}Ipn•HDP-101-4K]
•
ECN}X&]
Information and Other Queries
Query part number
Query Firmware version
Query Firmware version with build
Query model name
Query model description
Reset to factory default settings
N
Qn.nn
*Qn.nn.nnnn
1i
2i
E
ZXXX}Zpx]
Response
(Device to Host)
Sig
X!•X!]
X$]X$: 1 = default
EdidA
X$]
X%]X%: 1 = default
Vrb
X%]
X&]
•
Ipn
X&]
•
X^]
Pno
X^]
•
HDP•101•4K]
Inf01•HDP101•4K]
HDMI•TO•DP•4K•30]
Inf02•HDMI•TO•DP•4K•30]
Additional Description
Input*output (unsolicited)
Verbose mode 2/3
Verbose mode 2/3
Verbose mode 2/3
Up to 24 alphanumeric characters
including "-"
Verbose mode 2/3
Verbose mode 2/3
Verbose mode 2/3
Verbose mode 2/3
NOTE:
X! =
Status — 0 = Off/low/undetected, 1 = On/high/detected
Text string of up to 24 alphanumeric characters and hyphen (-). No spaces allowed, and no distinction between upper and
X& =
lower case. First character must be a letter and the last must not be a hyphen. Default is “HDP-101-4K”.
6
HDP 101 4K • User Guide (Continued)
Product Configuration Software
The HDP1014K uses Extron Product Conguration Software (PCS) to congure and reset the unit, as well as upload rmware.
Download Software from the Extron Website
Visit www.extron.com to download the latest version of PCS.
NOTE: Also download the latest versions of software and firmware for the HDP1014K. To update firmware, use PCS or
download and install Firmware Loader.
1. Click the Download link at the top of the Extron website (see figure5 ,
1
).
11
2
2
Figure 5. Software and Firmware Links on Download Page
2. Click the appropriate link on the left sidebar menu (
For software, either click the Software link at the top of the sidebar or, if the software is listed in the sidebar, click directly on
that link (for example, see the PCS link in figure5 , 2).
3. If there is no direct link to the software or rmware, scroll down to the alphabetic navigation bar (see gure 6).
Figure 6. Alphabetic Navigation Bar
4. Click the appropriate letter to locate the software or rmware (for example, click H for the HDP1014K).
5. Click Download and follow the on-screen instructions.
2
).
Using PCS
1. Connect the control PC, with PCS installed, to the HDP1014K. The Windows-based PCS communicates with the device via
the Front Panel Conguration port (see figure2, Apage 3) with a standard USB mini-B connector.
2. Open PCS on the control PC from the PCS icon loaded on the desktop (optional, see image on the right) or
The Product Conguration Software opens to the DeviceDiscovery screen:
1
Figure 7. PCS Device Discovery Screen
3
2
7
HDP 101 4K • User Guide (Continued)
3. Select the HDP1014K device by clicking on it to highlight it in the list (see figure7,
on the previous page).
1
NOTE: If the device does not appear in the list and one or more network adapters are being used, click on the Network
Adapter button (3) to select the appropriate adapter.
4. Click Connect (
The ProductConfigurationSoftware opens to the device main menu.
12
2
).
Figure 8. HDP1014K PCS Main Menu
The conguration pages have a global navigation bar (see figure8) from which each of the individual conguration pages can
be accessed.
These pages are:
5. Select either of these pages to begin conguring the HDP1014K.
Input/Output Configuration
1
EDID Minder
2
Input/Output Configuration
This page allows users to view the status of the input and congure the output.
Input Configuration
Figure 9. Input Configuration Panel
The InputConfiguration panel (see figure9) allows the user to view the signal presence of the input.
• Signal Presence — Connection status icon shows green when an active HDMI signal is present.
8
HDP 101 4K • User Guide (Continued)
Output Configuration
2
Figure 10. Output Configuration Panel
• Signal Presence — Signal status icon shows green when an active DisplayPort signal is present (see figure10).
EDID Minder
EDID Minder is an EDID process that manages the resolution and refresh rate between the HDP1014K HDMI input and the
DisplayPort output source. Click the EDIDMinder icon (see figure11, 1) on the global navigation bar to open the EDIDMinder
page. EDID can be set to match output rate, a custom user-dened EDID, or a factory setting.
1
2
34
5
6
7
8
9
Figure 11. EDID Minder Page
Filtering Available EDID
Use the Filter tab (2) to limit the number of available EDID displayed in the Favorites, Connected Output, and
Available EDID panels.
1. From the Resolution drop-down menu (
2. From the RefreshRate drop-down menu (
3. From the VideoFormat drop-down menu (
4. From the AudioFormat drop-down menu (
), select a specic resolution or Any.
3
), select a specic refresh rate or Any.
4
), select HDMI or Any.
5
), select LPCM 2-Ch, None or Any.
6
9
HDP 101 4K • User Guide (Continued)
Assigning EDID
To assign EDID to the input:
1. From the Input box on the right (see figure11,
2. From the Favorites, AvailableEDID, or ConnectedOutput panel on the left, select the desired EDID.
3. Then either:
• Click the Assign button (
OR
• Drag and drop the EDID image from the Favorites, AvailableEDID, or ConnectedOutput panels to the Input box.
) to assign EDID to the input.
8
Adding EDID to the EDID Library
1. Click the AddEDID to Library button (see figure11,
window opens (see figure12).
1
on the previous page), select the input.
7
on the previous page). The BrowseAddEDIDtoLibrary
9
2
Figure 12. Browse Add EDID to the Library Window
2. Navigate to the desired EDID le location and select it (
1
).
NOTE: Valid EDID files have a .bin file extension.
3. Click the Open button (
). The EDID is added to the Available EDID panel.
2
Device Menu
Disconnect the device from PCS
1
View the hardware Settings
2
ResetDevice to factory default
3
UpdateFirmware
4
View information AboutthisModule
5
1
2
3
4
5
Extron PCS Help File
For assistance, Extron PCS Help contains complete information about using the
program to congure the HDP1014K.
To access Extron PCS Help, click the button in the top right corner of the PCS program
screen (see the image on the right, 1) and click on Extron PCS Help(2).