Extron Electronics GLI 2000 5BNC Setup Guide

GLI 2000 5BNC • Setup Guide
This card provides quick start instructions for an experienced installer to set up and operate the GLI 2000 5BNC. The GLI 2000 5BNC is a heavy duty passive ground loop inhibitor, eliminating hum bars and common mode noise created by improper equipment grounding.
Installation
Step 1 — Mounting
Turn off or disconnect all equipment power sources and rack mount the GLI 2000 5BNC device using four GLI 2000 5BNC 4 - 40 x 3/16 inch screws as required.
IMPO RTANT:
Refer to www.extron.com for the
complete specifications.
Step 2 — Connect Inputs
a
Connect the video source inputs to the 5 BNC outputs of the GLI 2000 5BNC.
RG B
RGBHV
H
RG B
V
RGBS
H
V
RG B
RsGsBs, RGsB, YUV, Y/C, Composite
NOTE: The H and V channels on the GLI 2000 5BNC have
a bandwidth of 200 MHz rather than 425 MHz, and should not be used for high resolution signals.
Extron USA Headquarters
+1.800.633.9876 (Inside USA/Canada Only)
© 2012 Extron Electronics — All rights reserved. All trademarks mentioned are the property of their respective owners. www.extron.com
Extron USA - West: +1.714.491.1500 FAX: +1.714.491.1517 Extron USA - East: +1.919.850.1000 FAX: +1.919.850.1001
H
V
G
R
OUTPUT
GLI 2000 5BNC • Setup Guide (continued)
Step 3 — Connect Outputs
Connect the video source outputs to the 5 BNC inputs of the GLI 2000 5BNC.
Example of a Typical GLI 2000 Application
INPUT
BUFFERED LOCAL MONITOR OUTPUT
H. SHIFT
ID PIN 4 ID PIN 11
b
VGA INTERFACE W /ADSP
RGB 109 xi
Extron RGB 109xi
Interface
Extron GLI 2000 5BNC
Ground Loop Inhibitor
INPUT
B
G
R
OUTPUT
GLI 1000 5BNC
V
H
Projector
1
INPUT
BH
2
V
68-811-01
Rev. B
08 12
GLI 2000 5BNC
GROUND LOOP INHIBITOR
Computer