FOX II RS 104 and FOX RS 104 • Setup Guide
Video A
Video Audi
Fiber Optic RS-232 Inserter
Inserter connected on switcher input
Inserter connected on
ããÜÜÕÕÎÎ
This guide provides instructions for an experienced installer to set up and operate the Extron FOX RS 104 and FOX II RS 104 RS-232 Inserters. The inserters provide local insertion points for long-haul RS-232 control. The inserters can be installed on the input of a ber optic matrix switcher (see the gure below left) or on the output (see the gure below right).
NOTES:
The FOX II RS 104 supports Extron legacy and FOX II products. The FOX RS 104 supports legacy products only. The two
models are otherwise functionally identical.
For more information on any subject in this guide, see the FOX RS 104 and FOX II RS 104 RS-232 Inserters User Guide at
www.extron.com.
IMPORTANT:
Go to www.extron.com for the complete
user guide, installation instructions, and
ore connecting the
wer source.
Tx
Rx
FOX Tx
&
udio
&
o
OUT
IN
FOX Matrix Switcher
Installation
Step 1 — Mounting
Turn off or disconnect all equipment power sources and mount the inserter as required.
Step 2 — Connections
Fiber optic connectors and LEDs — Each
A
port, 1 through 4, has two SFP optical transceiver modules with LC connectors, labeled “A” and “B.” Transceiver B is connected to an internal UART that inserts serial communications into the ber optic signal or extracts the serial communications, depending on the application (see the connection example drawings above).
PC or
Control System
Ethernet
Control
LAN
Inserted RS-232
1
Tx Rx
AB
Tx Rx
UART
FOX II RS 104
Fiber Optic RS-232 Inserter
LAN
switcher output
PC or
Control System
FOX Matrix Switcher
OUT
Video & Audio
FOX Rx
CC BBAA AA AA AA
Rear
100-240V ~ 50/60 Hz
1
Tx Rx
Tx Rx
0.3 A MAX
ABABABAB
IN
Video, Audio & Inserted RS-232
Tx
Rx
2
Tx Rx
Tx Rx
Tx Rx
AB
FOX II RS 104
3
Tx Rx
Tx Rx
Ethernet
1
Tx Rx
Tx Rx
4
Control
LAN
UART
Tx Rx
LAN
Optical return signal
FOX II RS 104
LAN
RESET
WARNING: The FOX inserter outputs continuous invisible light (class 1 rated), which may be harmful to the eyes; use
with caution. Plug the attached dust caps into the transceivers when the ber cable is unplugged.
AVERTISSEMENT : Le FOX inserter émet une lumière invisible en continu (conforme à la classe1) qui peut être dangereux
pour les yeux, à utiliser avec précaution. Branchez les protections contre la poussière dans l’ensemble émetteur/récepteur lorsque le câble bre optique est débranché.
NOTE: Ensure that you use the proper fiber cable for your inserter. Typically, singlemode fiber has a yellow jacket and multimode
cable has an orange or aqua jacket.
Tx A — For one-way communication from the inserter to a downstream device, typically a matrix switcher, connect a ber optic
Î
cable to the Tx A LC connector. Connect the free end of this ber optic cable to the In or Rx connector on the downstream device.
1
FOX II RS 104 and FOX RS 104 • Setup Guide (Continued)
Front
AA BB
Rx A — To receive one-way transmission from an upstream device, typically a matrix switcher, connect a ber optic cable to the
Õ
Rx A LC connector. Connect the free end of this ber optic cable to the Out or Tx connector on the upstream device.
Tx B — For one-way communication from the inserter to a downstream device, which typically can be either a receiver or a
Ü
transmitter, depending on the application, connect a ber optic cable to the Tx B LC connector. Connect the free end of this ber optic cable to the Rx connector on the downstream device.
Rx B — To receive one-way transmission from an upstream device, which typically can be either a transmitter or a receiver,
ã
depending on the application, connect a ber optic cable to the Rx B LC connector. Connect the free end of this ber optic cable to the Tx connector on the upstream device.
Tx Link and Rx Link LEDs — When lit, the link on the associated LC connector is active (light is received).
LAN port — For IP conguration of the inserter and to insert serial data into and extract it from the ber stream, connect the unit to a
B
PC or to an Ethernet LAN via this RJ-45 connector. Use a PC for conguration (with SIS commands or downloaded HTML pages from the inserter) and serial data insertion and extraction from anywhere in the world.
Link LED indicator — The green (link) LED indicates that the inserter is properly connected to an Ethernet LAN. This LED should light steadily.
Act LED indicator — The yellow (activity) LED indicates transmission of data packets on the RJ-45 connector. This LED should blink as the inserter communicates.
AC power connector — Plug a standard IEC power cord into this connector to connect the inserter to a 100 VAC to 240 VAC,
C
50-60 Hz power source.
Front Panel Features
Power LED — This LED lights green when power is applied.
A
Input Data Rate switch — This switch selects between the 2.125 Gbits (2G) and
B
4.25 Gbits (4G) input data rate. After switching data rates, cycle the inserter power to properly lock onto the selected input data rate.
INPUT DATA RATE
2.125G
4.25G
Operation and Configuration
To insert RS-232 commands into or extract RS-232 responses from the ber optic signal stream, connect a computer or other Ethernet­capable device to the rear panel LAN port and access the inserter via TCP connection to the ports mentioned below. To congure the inserter, use either SIS commands (see “Selected SIS Commands — Enable and Disable Serial Insertion Ports,” below) or the built-in HTML pages (see “Embedded Web Pages,” below).
Selected SIS Commands — Enable and Disable Serial Insertion Ports
Command ASCII Command
(host to unit)
Enable one port
Disable one port Enable all ports Disable all ports View port status
EX!
EX! E
0*1LRPT
E
0*0LRPT
EX!
}
*1LRPT
}
*0LRPT
} }
} X@] X@
LRPT
Embedded Web Pages
1. Click in the Address eld of a Web browser and enter the inserter address.
NOTE: 192.168.254.254 is the factory-specified default.
2. Press the keyboard <Enter> key.
If the inserter is not password-protected, it checks and downloads the startup page. If the inserter is password-protected, the inserter prompts for a password (see right).
3. Click in the Password eld and type in the appropriate password. Click OK.
Extron Headquarters
+800.633.9876 Inside USA/Canada Only
Extron USA - West Extron USA - East
+1.714.491.1500 +1.919.850.1000
+1.714.491.1517 FAX +1.919.850.1001 FAX
2
© 2015 Extron Electronics All rights reserved. All trademarks mentioned are the property of their respective owners. www.extron.com
Extron Europe
+800.3987.6673
Inside Europe Only
+31.33.453.4040
+31.33.453.4050 FAX
Response
(unit to host)
LrptX!*1
LrptX!*0 Lrpt0*1 Lrpt0*0
]
] ] ]
Extron Asia
+65.6383.4400
+65.6383.4664 FAX
Additional description
Enable serial insertion port X! (allow data to be inserted onto ber optic port X!). Disable serial insertion port X!.
= 0 (disabled) or 1 (enabled).
Extron Japan
+81.3.3511.7655
+81.3.3511.7656 FAX
Extron China
+86.21.3760.1568
+86.21.3760.1566 FAX
Extron Middle East
+971.4.299.1800
+971.4.299.1880 FAX
X!
= UART Port
Extron Korea
+82.2.3444.1571
+82.2.3444.1575 FAX
Telnet port
1 2001 2 2002 3 2003 4 2004
Extron India
1800.3070.3777
(Inside India Only)
+91.80.3055.3777
+91.80.3055.3737 FAX
68-2172-50 Rev. B
01 15
Loading...