Extron offers a range of eBUS Button Panels (EBPs)in one-gang EU and MK form factors. They can be mounted into one-gang
EU or MK enclosures and can also be mounted alongside other EU, MK, or Flex55 products in larger enclosures. Each panel is a
fully customizable AV system control interface for use with Extron IPCPPro Series control processors. Individual EBPs are easily
congured and can be connected with other panels to provide control for large and complex AV systems.
NOTE: These products are only for use with Extron UL Listed IPCP Pro controller products.
Each EBP button panel has two eBUS ports that support power and communications between the IPCPPro control processor
and eBUS devices. Up to eight eBUS devices such as EBP button panels can be connected to the control processor and to each
other in various cabling topologies. Cabling topology refers to the physical layout of cabling interconnections between devices
in a network such as an eBUS system. eBUS systems can include daisy chain, star, or hybrid system (a combination of both)
topologies (see the eBUS Technology Reference Guide, available on www.extron.com, for basic diagrams). Every device must
have a unique identication address (eBUS ID) within the system.
Setup involves setting eBUS ID DIP switches on the EBPs, then using Extron GlobalCongurator® Plus and Professional
software, the Toolbelt utility, or Global Scripter programming software, to congure the control processor. Once congured, the AV
system can be controlled from any of its EBPs.
This guide provides basic instructions for an experienced installer to install the EBP EU or MK series button panels. For more
details on the EBPs, see the eBUS Technology Reference Guide, available on www.extron.com. For details on conguration or
programming, see the software help les.
EBP Rear Panel Features
B
AA
B
L
S
S
M
C
C
R
+S -S G+V +S -S G
D
D
+V
eBUS
PWR LOAD = 1.5W
B
B
BB
B
L
S
B
AAA
1
S
B
M
= X.XW
PWR LOAD
Figure 1. EBP EU Models: Rear View
C
CC
R
DD
D
+V +S -S G+V +S -S G
COM ERROR
ID ERROR
eBUS
STATUS
RED
GREEN LINK
AMBER
Other EBP EU and MK Models
The features shown in gure 1 are the same for all EBP EU and MK models, except for the EBP 104 EU and EBP 104 MK.
DIP switches — Up to eight devices can be connected to one control processor. Each device connected to the same control
A
processor must have a unique eBUS ID, which is set using DIP switches (see Step 4: Set the eBUS ID on page 6).
eBUS connectors (2 ports) — The four-pole captive screw connectors use the Extron eBUS protocol to connect the panel to
B
a controller and to other panels (see Step 5: Cable All Devices on page 9).
eBUS connection status LEDs — Provide diagnostic information about the connection, communication, and power status
C
of the panels.
zThe EBP 104 EU and EBP 104 MK has a single LED that can light yellow, red, or green.zAll other EBP Decorator-style models have a single green LED.
For more information about how the LEDs are used for troubleshooting, see Step 7: Test and Troubleshoot on page 11.
Reset button — Resets the rmware to the factory installed version. To reset the rmware:
D
1. Disconnect the eBUS cable that is providing power.
2. While reconnecting power, press and hold down the Reset button.
3. Release the Reset button 1 second after reconnecting power.
During the reset process, the front panel buttons are not lit. When the eBUS Status LED lights, the reset process is
complete, and the EBP is functioning normally. For the EBP 104 EU and EBP 104 MK, the green Link LED lights to show
that the EBP is functioning normally.
1
eBUS® Button Panel EU and MK Series • Setup Guide (Continued)
EBP VC1 EUEBP VC2 EUEBP NAV EU
EBP Front Panel Features
Figure 2 shows the range of EBP EU front panels. The EBP MK series is the same except for the wall frame surrounding the
button plate. All buttons are back-lit with LEDs to identify the active button. Inactive buttons can be backlit dimly to help identify
them in low ambient lighting.
AA
SOURCE 1
SOURCE 3
SOURCE 2
Extron
MUTE
G
G
AA
PC
LAPTOP
VIDEO
DOC CAM
AUX VIDEO
Extron
B
B
AA
DISPLAY
ON
PC
LAPTOP
VIDEO
Extron
EBP 104 EUEBP 105 EUEBP 105P EU
B
B
D
DAA
DISPLAY
ON
VOLUME
VIDEO
Extron
PC
OFF
E
E
C
C
B
B
D
D
AA
DISPLAY
ON
OFF
VOLUME
PC
VIDEO
LAPTOP MUTE
Extron
E
E
C
C
AA
ON
PC
DOC
CAM
Extron
EBP 106 EUEBP 108 EUEBP 110 EU
VOLUME
F
F
G
G
MUTE
EE
DD
D
D
–+
–+
E
E
EE
HH
OK
CH +
VIDEO
CH −
VIDEO
OFF
OFF
LAPTOP
VIDEO
VGAHDMI
TITLE
VIDEO
INFO
VIDEO
C
C
Figure 2. EBP EU Series front panels
NOTES:
• The buttons and encoders must be congured or programmed to carry out their functions.
• Use Global Congurator Plus and Professional and Toolbelt to congure the EBP buttons and LEDs.
• Use Global Scripter to program the EBP buttons and LEDs.
Function buttons — These buttons must be congured to carry out various functions.
A
Power buttons — Control the power to the display device. The On button has a nub that can be felt with the nger tips.
B
Transmit LED — Blinks once when any button is pressed.
C
Volume Control
Volume buttons — Increment or decrement audio volume.
D
Volume LED meter — Shows the volume level.
E
Volume rotary encoder — Increment or decrement audio volume.
F
Mute button — Toggle between audio mute and unmute. You can congure the mute button so that it is backlit red when
G
muted and white when unmuted for a visual indication of the status.
Video Control
Transport control buttons — Used to control a DVD or Blu-ray player.
H
2
Product Category
Planning the System and Installation
When planning to install an eBUS system, consider how many EBP button panels to use, maximum cable distance, cabling
topology, and mounting. See the eBUS Technology Reference Guide for more information about eBUS topologies.
Installation
Step 1: Get Ready
Use the following check list to prepare for the installation.
Download and install the latest version of the software, rmware, and device drivers needed to congure or program the
IPCPPro and control the connected AV products. See the IPCPPro Series User Guide (available at www.extron.com)
for details on software and drivers.
Obtain model names, drivers, and setup information for AV devices.
Determine which eBUS cabling topologies to use and obtain cables, mounting hardware, and any power supplies or
hubs required by that conguration.
Step 2: Prepare the Installation Site
ATTENTION:
• Installation and service must be performed by authorized personnel only.
• L’installation et l’entretien doivent être effectués par le personnel autorisé uniquement.
• If the EBP will be installed into ne furniture, it is best to hire a licensed, bonded craftsperson to cut the access hole
and perform the physical installation so the surface will not be damaged.
• S’il est prévu d’installer le EBP dans du beau mobilier, il est préférable de faire appel à un artisan autorisé et qualié
pour couper le trou d’accès et réaliser l’installation de telle façon que la surface ne soit pas endommagée.
• Follow all national and local building and electrical codes that apply to the installation site.
• Respectez tous les codes électriques et du bâtiment, nationaux et locaux, qui s’appliquent au site de l’installation.
Site preparation
The EBPEU panels t any one-gang EU junction boxes, enclosures having 60 mm mounting centers, or Flex55 enclosures. The
EBP MK panels t any standard MK junction box. In addition, Extron offers an assortment of optional in-wall junction boxes,
external wall boxes (EWBs), and surface or tabletop mounting boxes for use with the eBUS button panels (see www.extron.com).
NOTE: For the installation to meet UL requirements and to comply with National Electrical Code (NEC), the EBP must be
installed in a UL Listed junction box (not included with the EBP). The end user or installer must furnish the junction box.
Americans with Disabilities Act (ADA) compliance
When planning where to install these devices, you may need to consider factors affecting accessibility of the button panel such
as height from the oor, distance from obstructions, and how far a user must reach to press the buttons. For guidelines, see
sections 307 (“Protruding Objects”) and 308 (“Reach Ranges”) of the 2010 ADA Standards for Accessible Design available at
You can replace a faceplate or one or more of the individual buttons. You can order replacement or custom buttons using the
Custom Button Builder at www.extron.com. To replace the buttons:
1. If required, remove the rotary encoder knob (EBP VC1 EU or EBP VC1 MK only) (see Remove the rotary encoder knob
(VC1 models only) on the next page).
2. Remove the button panel. For most models, see Remove the bezel (except the EBP 104 EU and EBP 104 MK) on the
following page. The procedure is slightly different for the EBP 104 EU and EBP 104 MK (see Remove the bezel on the EBP
104 EU or EBP 104 MK on the following page).
3. Separate the button panel from the control panel. This step uses the same procedure for all models (see Separate the bezel
from the button board (all models) on page 5)
4. Replace the buttons. For all models except the EBP 104 EU or EBP 104 MK, see Replace buttons for all models (except
EBP 104 EU and EBP 104 MK) on page 5. For the EBP 104 EU and EBP 104 MK, see Replace buttons for the
EBP 104 EU and EBP 104 MK on page 5.
3
eBUS® Button Panel EU and MK Series • Setup Guide (Continued)
h
.
Remove the rotary encoder knob
(VC1 models only)
The EBP VC1 EU and EBP VC1 MK have a rotary encoder
knob. Before replacing the buttons, remove the encoder, as
shown here.
1. EBP VC1 EU and EBP VC1 MK only: Turn the rotary
encoder knob (gure 3, 1) to expose the hex screw
holding the knob in place (2).
2. Insert the provided 0.05 inch Allen wrench and turn the
wrench in the direction shown (3) to loosen the screw.
3. Pull the knob straight out to remove it.
Once the encoder knob is removed, removing the faceplate
and replacing the buttons is the same for all models.
Remove the bezel (except the EBP 104 EU and
EBP 104 MK)
Insert the Extron pry tool into the gap between one side of the
bezel and the frame. Release the locking tab holding the bezel
to the metal mounting bracket (gure 4, 1). There is a single
catch in the middle of each side. If necessary, use the pry tool
to release the second catch on the opposite side.
The frame is held in place by the bezel. When the bezel is
removed, the frame also comes away from the wall. Pull the
device and the frame away from the wall.
1
Turn Knob to
Expose Screw
MUTE
VOLUME
Figure 3. Remove the Rotary Encoder (VC1 models only)
Extron
DISPLAY
ON
VOLUME
LAPTOP
VIDEO
OFF
11
Extron
Insert
to line
3
Use Allen Wrenc
to Loosen Screw
2
Remove the bezel on the EBP 104 EU or
EBP 104 MK
The EBP 104EU and EBP 104MK have two locking tabs
at the top and two more at the bottom.
Insert the Extron pry tool between the top of the bezel
and the frame and slide it to the location of one of the
locking tabs (see gure 5, 1). Pull the pry tool up so
that the locking tab is pressed down, which releases it
(2).
When the rst catch is released, slide the pry tool along
the gap between the bezel and the frame to release the
second catch.
If necessary, use the pry tool to release the catches on
the bottom of the bezel.
Tip the bezel forward and remove it (3). The frame is
held in place by the bezel. When the bezel is removed,
the frame will also come away from the wall. Pull the
device and the frame away from the wall.
Figure 4. Release Bezel
Locking
Pry Tool
SOURCE
2
SOURCE
1
MUTE
SOURCE
3
At the locking tab
1
locations, insert the
pry tool up to the
line below the arrow.
Figure 5. Release Bezel (EBP 104 EU or EBP 104 MK)
Tabs (2)
SOURCE
SOURCE
1
MUTE
SOURCE
3
Pull the pry tool to the
2
left to unhook each
locking tab from the
mounting bracket.
2
Remove the
3
module.
SOURCE
SOURCE
3
SOURCE
2
1
MUTE
4
LAPTOP
TEXT
Separate the
two-piece button
here at the corner.
Diffuser
Base
Insert
button label.
Button
Lens Cap
Removal
Tool
1
2
Separate the bezel from the button board
(all models)
1. Insert a small at-bladed screw driver into one
of the slots (see gure 6, 1). There are two
slots on each side.
2. Press in the blade of the screw driver until the
tab is pushed out of the slot (there is an audible
click when this happens).
3. Repeat steps 1 and 2 to release all four tabs
holding the bezel to the button board.
4. Tilt the top of the bezel forward so the buttons
do not fall out as you remove it (2).
2
2
Figure 6. Releasing the Button Plate
DISPLAY
ON
VOLUME
LAPTOP
VIDEO
OFF
Replace buttons for all models (except EBP 104 EU and EBP 104 MK)
1. From the front of the bezel, press the button or button pair to be replaced backward
through its slots in the bezel until the membrane containing the button is free.
2. On the back of the bezel, insert the replacement button or button pair into the
appropriate slots. Ensure the text is in the correct orientation. Align the two pegs in
the button membrane (see gure 7, 1) with the holes located at opposite corners of
the empty space in the faceplate.
3. Press the two buttons into the bezel until the pegs on the membrane are seated in
the corresponding holes.
4. Repeat steps 5 through 7 for any other buttons that you want to replace.
5. Align the button board with the bezel, and press it into place. The four tabs released
in steps 1 through 3 of the previous section snap back into place. Ensure the bezel
is in the correct orientation, reattach the frame, and press the bezel back into the
mounting bracket, using the two catches released in Remove the bezel (except the
EBP 104 EU and EBP 104 MK) on the previous page.
6. EBP VC1 EU and EBP VC1 MK only: Replace the rotary encoder knob by reversing
the procedure that was described in Remove the rotary encoder knob
(VC1 models only) on the previous page.
11
Product Category
11
Figure 7. Replacing Buttons
MUTE
Replace buttons for the EBP 104 EU and EBP 104 MK
You can replace one or more of the labels within the buttons. Some button labels ship with the unit. You
can create and print your own customized labels using Extron Button Label Generator software.
To change a label, follow these instructions.
1. Remove the bezel on the EBP 104 EU or EBP 104 MK as described on the previous
2. Separate the button plate from the control plate.
3. Gently separate the button lens button cap from its white diffuser: insert the
4. Remove the label insert from the button cap. software.
5. Select one of the button labels from the printed label sheets included
6. Insert the button label into the button cap (
7. Align the cap with the white diffuser and the panel opening, and
8. Reattach the faceplate to the EBP as described in Mounting EBP EU
page.
end of the provided Extron removal tool into the corner notch and gently
twist the tool (see gure 8, 1).
TIP: If the insert does not come out easily, use a piece of
sticky tape to pull it out of the button cap.
with the unit. Remove the label from its backing and remove the
clear, protective lm from the front of the label.
press the clear cap into place on the button.
or EBP MK Devices to an Electrical Wall Box on page 12 or
Mounting EBP EU Devices in a Raceway on page 13.
2
).
Figure 8. Replacing Buttons on the EBP 104 EU
and EBP 104 MK
5
eBUS® Button Panel EU and MK Series • Setup Guide (Continued)
M
Step 4: Set the eBUS ID
Up to eight devices can be connected to one control processor. In order for the control
processor to be successfully congured, each device connected to the same control
processor must have a unique six-bit, eBUS ID, which is set with the DIP switch
assembly on the rear panel of the EBP (gure 9, 1). If two or more modules have
the same eBUS ID, address conicts may cause one or more of the panels to not be
recognized by the IPCPPro control processor.
Various combinations of the six DIP switches being set to On or Off, provide 64
addresses: 0 is a reserved eBUS ID and the congurable eBUS ID range is 1 through
63 (see the table on the two following pages). The section below shows an example of
binary to decimal conversion.
eBUS ID Setup
Dip Switch
ON
S
B
1 2
BUS ID
4
3
56
L
S
Slide
B
Position
Decimal
1
Off
Off
5
4
2
=32
2
2
=16
3
Off
Off
2
3
2
2
=8
4
=4
2
5
On
1
=2
Off
2
Figure 9. EU and MK eBUS Panel
6
0
=1
11
DIP Switches
Figure 10. eBUS ID Setup
Add the decimal numbers for each of the DIP switches that are set to On to obtain the address of the device. In gure 10, only
DIP switch 5 is on and the rest are off, which means the address for the device in gure 9 is 0+0+0+0+2+0 = 2.
NOTES:
• Any address can be used except address 0 (binary: 000000), which is reserved (as the address of the controller) and
may not be used.
• Switch 1 (on the left) is the highest value (32, the most signicant bit) and is labelled MSB.
• Switch 6 (on the right) is the lowest value (1, the least signicant bit) and is labelled LSB.
• Up = on = 1, Down = off = 0
The following table shows the factory default eBUS IDs and the corresponding addresses for the EU and MK models. These IDs
can be changed to any valid value.
ModelAddresseBUS ID
EBP 104 EU or MK24011000
EBP 105 EU or MK6000110
EBP 105P EU or MK14001110
EBP 106 EU or MK5000101
EBP 108 EU or MK10001010
EBP 110 EU or MK11001011
EBP VC1 EU or MK12001100
EBP VC2 EU or MK16010000
EBP NAV EU or MK19010011
The table on the following two pages shows the DIP switch settings for all 64 possible addresses.
6
Product Category
DIP Switch Setting
1 2 3 4 5 61 2 3 4 5 6
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
0 0 0 00 0
L
S
B
0 0 0 00 1
L
S
B
0 0 0 01 0
L
S
B
0 0 0 01 1
L
S
B
0 0 01 0 0
L
S
B
0 0 01 0 1
L
S
B
0 0 01 1 0
L
S
B
0 0 01 1 1
L
S
B
0 0 10 0 0
L
S
B
0 0 10 0 1
L
S
B
0 0 10 1 0
L
S
B
0 0 10 1 1
L
S
B
0 0 11 0 0
L
S
B
0 0 11 0 1
L
S
B
0 0 11 1 0
L
S
B
Decimal
Value
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
DIP Switch Setting
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
0 0 11 1 1
L
S
B
0 1 00 0 0
L
S
B
0 1 00 0 1
L
S
B
0 1 00 1 0
L
S
B
0 1 00 1 1
L
S
B
0 1 01 0 0
L
S
B
0 1 01 0 1
L
S
B
0 1 01 1 0
L
S
B
0 1 01 1 1
L
S
B
0 1 10 0 0
L
S
B
0 1 10 0 1
L
S
B
0 1 10 1 0
L
S
B
0 1 10 1 1
L
S
B
0 1 11 0 0
L
S
B
0 1 11 0 1
L
S
B
Decimal
Value
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
7
eBUS® Button Panel EU and MK Series • Setup Guide (Continued)
DIP Switch Setting
1 2 3 4 5 61 2 3 4 5 6
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
0 1 11 1 0
L
S
B
0 1 11 1 1
L
S
B
1 0 0 00 0
L
S
B
1 0 0 00 1
L
S
B
1 0 0 01 0
L
S
B
1 0 0 01 1
L
S
B
1 0 01 0 0
L
S
B
1 0 01 0 1
L
S
B
1 0 01 1 0
L
S
B
1 0 01 1 1
L
S
B
1 0 10 0 0
L
S
B
1 0 10 0 1
L
S
B
1 0 10 1 0
L
S
B
1 0 10 1 1
L
S
B
1 0 11 0 0
L
S
B
1 0 11 0 1
L
S
B
1 0 11 1 0
L
S
B
Decimal
Value
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
DIP Switch Setting
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
ON
M
S
B
1 2
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
56
4
3
1 0 11 1 1
L
S
B
1 1 00 0 0
L
S
B
1 1 00 0 1
L
S
B
1 1 00 1 0
L
S
B
1 1 00 1 1
L
S
B
1 1 01 0 0
L
S
B
1 1 01 0 1
L
S
B
1 1 01 1 0
L
S
B
1 1 01 1 1
L
S
B
1 1 10 0 0
L
S
B
1 1 10 0 1
L
S
B
1 1 10 1 0
L
S
B
1 1 10 1 1
L
S
B
1 1 11 0 0
L
S
B
1 1 11 0 1
L
S
B
1 1 11 1 0
L
S
B
1 1 11 1 1
L
S
B
Decimal
Value
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
8
Product Category
+
G
S
+S
+V
Step 5: Cable All Devices
Attach cables using the diagrams in this section as a guide. Connect a 4-pole captive screw connector to each end of the cable,
wiring both ends as shown in gure 11. In most cases the EBPs are powered by the IPCPPro control processor that provides the
eBUS signal. Power is carried on the V+ pin of each eBUS connection.
The four connectors are:
z+V — carries 12 VDC power from the controller, active hub, or power supplyz+S — carries the positive data signalz-S — carries the negative data signalzG — ground
Extron STP20-2/1000 or STP20-2P/1000 cable is recommended for eBUS connections.
12 VDC
+ Signal
-
Signal
Ground
Drain Wires (2)
Figure 11. Basic eBUS Connector Wiring and Cable Color Code
Red
Green
White
Black
NOTES:
• The two eBUS ports are interchangeable: either port can be used to connect the device to a controller or EBDB
distribution hub and either can be used to daisy-chain the device to another EBP.
• Connect up to eight eBUS devices for each IPCP Pro control processor.
• Wire the connectors in the same way at both ends.
• Do NOT power an EBP from more than one power source.
• Do not exceed a total of 1000 feet (305 meters) of cable for connections between the IPCP Pro and all the EBP panels.
• Power is provided by the IPCP Pro. If additional power is required, use a PS 1220EB power supply and distribution
hub, or an Extron PS series desktop power supply. If more than one power source is used in a system, make sure that
the devices powered by the rst source are isolated from the devices powered by the second source by disconnecting
the +V pin appropriately (see figure 12 on the following page).
ATTENTION:
• Always use a power supply supplied or specied by Extron. Use of an unauthorized power supply voids all regulatory
compliance certication and may cause damage to the supply and the end product.
• Utilisez toujours une source d’alimentation fournie ou recommandée par Extron. L’utilisation d’une source
d’alimentation non autorisée annule toute conformité réglementaire et peut endommager la source d’alimentation ainsi
que le produit nal.
• If not provided with a power supply, this product is intended to be supplied by a UL Listed power source marked
“Class2” or “LPS” and rated output 12VDC, minimum 1.0A.
• Si le produit n’est pas fourni avec une source d’alimentation, il doit être alimenté par une source d’alimentation
certiée UL de classe 2 ou LPS, avec une tension nominale 12 Vcc, 0,5 A minimum.
• Unless otherwise stated, the AC/DC adapters are not suitable for use in air handling spaces or in wall cavities.
• Sauf mention contraire, les adaptateurs CA/CC ne conviennent pas à une utilisation dans les espaces d’aération ou
dans les cavités murales.
• The installation must always be in accordance with the applicable provisions of National Electrical Code ANSI/
NFPA70, article725 and the Canadian Electrical Code part1, section16. The power supply shall not be permanently
xed to building structure or similar structure.
• Cette installation doit toujours être conforme aux dispositions applicables du Code américain de l’électricité (National
Electrical Code) ANSI/NFPA 70, article 725, et du Code canadien de l’électricité, partie1, section16. La source
d’alimentation ne devra pas être xée de façon permanente à la structure de bâtiment ou à d’autres structures
similaires.
-
9
eBUS® Button Panel EU and MK Series • Setup Guide (Continued)
C
G
PO
1.0
G
Tx
R
S
CTS
3
2
4
G
G
TxR
C
S
G
LAN
M
X
S/
#
C
G
PO
1.0
G
S
CTS
3
G
G
C
S
G
LAN
M
S/
#
EBPs that are relatively far from the control processor (see the eBUS Technology Reference Guide on www.extron.com for
details) can be connected to an optional Extron PS1220EB eBUS power supply and distribution hub, or an Extron PS series
desktop power supply as shown in the following diagrams.
WER
A MAX
IPCP Pro
COM 1
xRT
VOL
COM 2
x
RELAYS
DIGITAL I/O
1
eBUS
-S+V +S G
PWR OUT = 6W
X
IPCP PRO 250
AC: 00-05-A6-XX-XX-X
IR/S
N: ####### E#####
100-240V 50-60Hz
Power Input
(100-240 VAC,
50-60 Hz)
ATTENTION:Do NOT connect the
power pin to any device that is already
powere d by the IPCP Pro control
0.6A MAX
-S+V +S G-S+V +S G-S+V +S G
eBUS 24 WATTS MAX
-S+V +S G-S+V +S G-S+V +S G
X
PS 1220EB
+12 VDC
+ Signal
-
Signal
Ground
3/16" (5 mm) Max.
processor or by an additional power
suppl y.
+ Signal
-
Signal
Ground
Tie drain wires
to ground.
Figure 12. Cabling an eBUS System with an PS 1220EB Power Supply and Distribution Hub
WER
A MAX
IPCP Pro
COM 1
xRT
VOL
COM 2
x
x
RELAYS
DIGITAL I/O
1
eBUS
-S+V +S G
PWR OUT = 6W
IPCP PRO 250
IR/S
AC: 00-05-A6-N: ####### E#####
-
3/16" (5 mm) Max.
Ground
-
Signal
+ Signal
Tie drain wires to ground.
Ground
-
Signal
+ Signal
+12 VDC
RidgedSmooth
eBUS Connections
• Connect up to ve (5) eBUS
endpoint devices to the PS 1220EB.
• Wire the connectors the same at both
ends.
• All ports are identical and
interchangeable.
EBP
+12 VDC input
– Return
Ground
EBP
External Power Supply
(12 VDC, 1.5 A max.)
all Devices
NOTE:
supply before connecting it to the EBP.
Check the polarity of the power
Figure 13. Cabling EBP Panels with an Extron PS Series Desktop Power Supply
NOTE: Although the rear panels for the EBP 104 EU and 104 MK are different from the rear panel shown in gures 12 and 13,
power and eBUS cables are connected in exactly the same way.
10
Product Category
Step 6: Configure the System
EBPs are shipped with pre-labelled buttons in place but these buttons do not have any functions associated with them until
they are congured with Global Congurator or programmed with Global Scripter. See the Global Configurator Help File or the
Global Scripter Help File for step-by-step instructions and detailed information.
Step 7: Test and Troubleshoot
1. Verify that the DIP switches on the EBPs are set to the desired address on each device and that there are no eBUS ID
conicts in the system.
2. The eBUS LED provides information about power and communication status and eBUS ID address conicts.
The EBP 104 EU and EBP 104 MK have an LED that shows three different colors:
zOff — If the LED is off, the device is not receiving power.zLED Lights Yellow— Lights solidly when the device is receiving power but communication with the control processor is
not conrmed.
zLED Lights Red — Lights solidly when there is a eBUS ID address conict.zLED Lights Green — Lights solidly when power and communication are both conrmed.
All other Decorator-style panels have a single green LED that provides information as follows:
zOff — The device is not receiving power.zSlow blink (1 blink per second)— The device is receiving power but communication with the control processor is not
conrmed.
zFast blink (2 blinks per second) — There is a eBUS ID address conict.zLights solidly — Power and communication are both conrmed.
3. Verify that cables to and from the EBPs are wired the same at each end (pin 1 to pin 1, pin 2 to pin 2, and so forth).
4. Test the system.
zPress buttons on the EBPs and ensure the buttons light as desired and that the appropriate control commands or
functions are triggered.
zEnsure that the audio output responds correctly to the volume knob or button. Also ensure that the volume LEDs light
correctly as you increase or decrease the audio gain.
5. Make adjustments to wiring, eBUS ID address, or system conguration as needed. Remember that the rear panel ports
and DIP switches will not be accessible after the EBP is mounted. If needed, upload a revised conguration to the control
processor.
If you have questions during installation and setup, call the ExtronS3 Sales & Technical Support Hotline or the ExtronS3
Control Systems Support Hotline (1.800.633.9877).
Step 8: Mount the EBPs
EBP panels can be installed directly into the wall using a 1-gang wall mounting bracket (mud ring) or a wall box.
ATTENTION:
• All electrical installation should be performed by qualied personnel in accordance with local and national building
codes, re and safety codes, and local and national electrical codes.
• Toute installation électrique devrait être effectuée par un personnel qualié, conformément aux codes du bâtiment, aux
codes incendie et sécurité, et aux codes électriques locaux et nationaux.
11
eBUS® Button Panel EU and MK Series • Setup Guide (Continued)
EBP 106 MK
Prior to mounting:
1. If it has not already been done, feed all device cables through the wall or furniture.
2. Ensure that cables are connected to the EBP rear panel (see EBP Rear Panel Features on page 1).
NOTE: The EBP VC1 EU and EBP VC1 MK are deeper than other EU or MK panels and have front panel rotary encoders that
protrude from the wall more than the buttons of the other models.
• Allow at least 1.44 inches (36.6 mm) depth in the wall or furniture for cables.
• The EBP VC1 EU or EBP VC1 MK front panel, including the rotary encoder, extends 0.77 inches (19.6 mm) from the
wall.
Mounting EBP EU or EBP MK Devices to an
Electrical Wall Box
The EBP EU models can be mounted into one-gang EU junction
boxes and enclosures having 60 mm mounting centers. Figure 14
shows how to mount the EBP 106 EU. Other 1-gang EU models are
mounted in exactly the same way. The EBP EU models can also be
mounted directly into an EU raceway (see Mounting EBP EU Devices
in a Raceway on the following page).
The EBP MK models can be mounted in any standard 1-gang
MK electrical junction box. Figure 15 shows how to mount the
EBP 106 MK. Other 1-gang MK models are mounted in exactly the
same way.
NOTES:
• The electrical wall box is not provided and must be
purchased separately.
• Install the electrical wall box by following the instructions
provided by the manufacturer.
• Use the metal bracket provided with EBP device.
Mount the EBP device as follows:
1. Decide where the panel will be located. Take into consideration
the position of wall studs and windows that could obstruct cable
runs.
2. Install the electrical wall box (
provided by the manufacturer.
3. Attach the provided mounting bracket (
) by following the instructions
1
) using the two
2
provided screws.
NOTES:
• The mounting brackets provided with the EU and MK
models are different and are not interchangeable.
• Ensure the bracket is in the correct orientation (with
the side marked “Front” facing away from the wall.
• The EU model is attached with screws at the top and
bottom.
• The MK model is attached with screws on both the
sides.
Wall Box
11
2
2
Mounting Bracket
Frame
Figure 14. Mounting with an EU Wall Box
Wall
MK Wall Box
2
2
11
Mounting Bracket
Frame
3
3
DISPLAY
OFF
ON
VOLUME
PC
EBP 106 EU
3
3
DISPLAY
ON
VOLUME
PC
PC
VIDEO
APTOP
L
OFF
VIDEO
MUTE
4. Disconnect power from all devices at the source and run cables
through the hole in the wall. Pass them through the metal bracket
and frame and connect them to the rear panel captive screw
connectors (see Step 5: Cable All Devices on page 9).
5. Set the DIP switches to give the panel a unique eBUS ID (See
Step 4: Set the eBUS ID on page 6).
6. Insert the EBP into the frame (
) and press the entire assembly
3
into the metal bracket (2). The EBP is secured to the metal
bracket by two catches (one on each side) and holds the frame in
place.
NOTE: The EBP 104 EU and EBP 104 MK are held in place by
12
four catches, two on the top and two on the bottom.
Figure 15. Mounting with an MK Wall Box
Mounting EBP EU Devices in a Raceway
J
F
e
M
i
ng
B
t
E
NOTES:
• If there is a gap between the metal mounting bracket and the wall frame, insert the provided raceway spacer between
the mounting bracket and the rim of the junction box (see gure 16).
The spacer looks very similar to the metal mounting bracket, but has a slightly larger center opening, has holes
instead of slots for the mounting screws, and is engraved with the words “Optional Spacer” and “Place behind
bracket.”
• Do not use the spacer instead of the metal mounting bracket. The spacer has a larger opening and will not hold the
EBP securely in the wall frame.
To mount the EBP EU to a raceway using the spacer:
1. Mount an electrical box in the raceway (Figure 16,
Follow the instructions provided by the manufacturer.
2. If required, align the screw holes of the provided spacer
with the holes in the electrical box (2).
3. Align the screw holes in the metal bracket with the holes
in the spacer and electrical box (3).
NOTE: Ensure that the front surface of the mounting
bracket is facing out (away from the wall).
4. Secure the metal bracket and spacer to the junction box,
using the two provided screws (4). Leave the screw
heads protruding approximately 1/8 inch (3.18 mm) from
the surface of the spacer.
5. Rotate the metal bracket as necessary to ensure that the
EBP will be aligned correctly on the mounting surface.
6. Tighten the screws to secure the bracket to the spacer.
7. Disconnect power from all devices at the source and
run cables through the raceway, junction box, spacer,
bracket and frame. Connect them to the rear panel
captive screw connectors (see Step 5: Cable All
Devices on page 9).
8. If you have not already done so, set the DIP switches to
give the panel a unique eBUS ID (See Step 4: Set the
eBUS ID on page 6).
9. Insert the EBP into the wallplate (
entire assembly into the metal bracket (6). The EBP
is secured to the metal bracket by two catches (one on
each side) and holds the frame in place.
NOTE: The EBP 104 EU and EBP 104 MK are held in
place by four catches, two on the top and two on
the bottom.
) and press the
5
1
unction Box
).
Figure 16. Mounting in an EU Raceway with Spacer
11
Cable Raceway
2
2
Raceway Spacer
3
3
Mounting Bracket
ount
6
6
Product Category
racke
Frame
4
4
ram
5
DISPLAY
ON
VOLUME
PC
EBP 106 EU
BP 106 EU
OFF
13
eBUS® Button Panel EU and MK Series • Setup Guide (Continued)
Removing EBP EU or MK Wallplates
If you need to remove an EBP EU or MK wallplate from where it is
mounted, follow these steps:
1. Insert the provided Extron removal tool into the gap between
the side of the button plate and the frame (gure 17, 1).
The tip of the tool should be inserted to the depth of the line
marked on the tool.
2. Slide the removal tool along the gap until the catch on the
side of the button plate (2) is released.
3. If necessary, repeat steps 1 and 2 to release the other side of
the button plate.
NOTE: The EBP 104 EU and EBP 104 MK are held in
place by four catches, two on the top and two on the
bottom and are removed by a different procedure (see
Remove the bezel on the EBP 104 EU or EBP 104
MK on page 4).
4. Pull the EBP away from the frame. The frame is released at
the same time.
5. Remove cables.
6. Remove the screws holding the metal bracket to the wall box