Extron electronics DVS 605 Setup Manual

Page 1
DVS 605 • Setup Guide
The Extron DVS 605 Digital Video Scalers are scaling products that allow most common signal formats to be processed, scaled, and output in any desired format. This setup guide allows an experienced user to easily and quickly set up and configure a DVS 605 using step by step instructions. It covers how to perform basic operations using the front panel controls and selected Simple Instruction Set (SIS™) commands.
NOTE: For full installation, configuration, menus, connector wiring, and operation details, see the DVS 605 User Guide,
available at www.extron.com
Installation
Rear Panel Features
The DVS 605 AD is shown here. All other DVS 605 models have some but not all of the features shown below.
DVS 605 AD
100-240 VAC ~ .7A MAX
50/60Hz
1
2
UNIVERSAL
3
INPUT OUTPUTS REMOTE
5
3
HDMI
4
AUX
HDMI
3G/HD - SDI
RGB/R-Y, Y, B-Y
8
7
GENLOCK
RESET
15
12345
CONTACT
RS-232 IR
Tx Rx SGG
LAN
L1R L2R L3R L4R L5R L
AUDIO INPUTS AUDIO OUTPUTS
FIXED
FIXED
R
S/PDIF
VARIABLE L
R
1
2
5
12
6
14
13
9410
11
Power and video input connections Output, user interface, and control connections
a AC power connector
b Universal analog VGA connectors
— inputs 1 and 2
c HDMI connectors — inputs 3-5
(Note: PIP is not available on input 5.)
d Audio 5-pole captive screw connectors
— inputs 1- 5 (audio models only)
e
HDMI connector
f
RGB/R-Y,Y, B-Y component VGA
connector
g
3G/HD-SDI connector (optional)
(SDI models only)
h
Genlock connectors — input and loop
through (SDI models only)
i
Audio output (fixed), 5-pole captive
screw connector (audio models only)
j
RCA audio (S/PDIF) output connector
(audio models only)
k
Audio output (variable), 5-pole captive
screw connector (audio models only)
l
Reset button and LED
m
RJ-45 LAN connector
n
RS-232 and IR 5-pole captive screw
connector
o
Contact closure 5-pole captive screw
connector (shares a ground with RS-232)
Mounting and Cabling
Step 1 — Mounting
Turn off or disconnect all equipment power sources and rack mount the DVS 605 unit using the pre-installed brackets (see image at right).
Step 2 — Connect inputs
Connect inputs from video sources to the applicable connectors marked “Inputs”. See b through c above for video connector types and d for audio connectivity.
Connect video and audio output devices to the applicable connectors marked “Outputs” (see e through k above).
Step 4 — Connect control devices
LAN port m — Connect an LAN or WAN via this RJ-45 connector for remote control of the DVS 605 using an Internet browser or the Extron configuration program, installed on a connected PC.
One connection LED lights green when connected to the LAN and one flickers amber as the devices communicate.
Rack Mount Bracket
NOTE: Do not use standard telephone cables for LAN connection, as they do not support Ethernet or Fast Ethernet.
Do not stretch or bend cables as transmission errors could occur.
RS-232/IR port — For serial RS-232 control, connect a host computer or control system to the 5-pole captive screw connector n. RS-232 protocol (default values): 9600 baud, 1 stop bit, no parity, 8 data bits, no flow control. By default the IR port is disabled.
Contact closure port — For remote input selection of any of the five inputs, connect a suitable contact closure control device to the 5-pole captive screw connector o. The contact closure port and the RS-232 port share a common ground.
1
Page 2
DVS 605 • Setup Guide (Continued)
Step 5 — Connect power
AC power connector — Plug in a standard IEC power cord from a 100 - 240 VAC, 50 - 60 Hz power source into this receptacle
Powering Up
When powering up the DVS 605 unit, it undergoes a self testing sequence (see image below). The LCD displays the default display cycle, with the signal type, resolution, and refresh rate for the currently selected input and the output resolution and refresh rate.
NOTE: When powered and not in any menu, the LCD screen defaults to cycling through the current input/output status. The
displayed content may vary depending on the input video signal type (see typical default display below).
Apply Power
Display screen
13
first lights blank
sec.
EXTRON
ELECTRONICS
All input LEDs flash
(red then green).
1 2 3
4 5 PIP
Front Panel Overview
The DVS 605 is shown here. All other models have the same features shown below.
Note: Times shown are approximate.
16 sec.
EXTRON
DVS 605 XX
Last active input
button(s) remains lit.
1
11 sec.
60-1059-xx
FW v1.xx
2 sec.
Default Display Cycle
2
IN
RGBHV
#1 640x480
2 sec.
sec.
OUTPUT 720p@60
IN 31.47 kHz #1 59.94 Hz
2 sec.
a
.
3
1 2 3
4 5 PIP
CONFIG
2
1
a
Front panel mini USB configuration port — Connect a control system or computer to this mini USB port (cable not supplied),
AUTO
SWAP
4
EXTRON DVS 605
5
MENU
NEXT
6
for device configuration, control, and upgrading the firmware.
b
Input selection buttons and LEDs (1-5) — Selects/switches inputs; adjacent LEDs indicate which input is active (current input
lights green, PIP input lights red).
c
Auto-Image™ button — Allows automatic image size and centering adjustments on selected input.
d
PIP and Swap Image buttons — These two buttons are:
•PIP—Opens or closes the PIP (Picture-In-Picture) window •Swap—SwapsthemaindisplayedimageandthecurrentPIPinputwitheachother,orwhennotinPIPmode,itwill
switch between current and previous input.
e
LCD display — This 12x2 screen displays device settings and menu configuration information.
f
Menu navigation buttons (Menu, Next) These buttons allow navigation through the menu system of the DVS 605.
g
Adjust knobs — These are used with the menu navigation buttons to adjust the device settings and picture control.
Setting the Front Panel Locks (Executive Modes)
The DVS 605 has three modes of front panel security lock that limit the operation of the unit from the front panel.
Executive mode 0 (disabled) — The front panel is fully unlocked. This is the default setting. Executive mode 1 (enabled) — The front panel is completely locked. It can only be enabled
and disabled using SIS commands, or through the embedded web pages. See the online DVS 605 User Guide for SIS commands. Executive mode 2 (enabled) — The front panel is locked except for input switching, PIP, swap, and Auto-Image.
Enabling or disabling Executive mode 2 from the front panel
If the DVS 605 unit is in Executive mode 0 (unlocked), the procedure shown at right selects mode 2 (locked). If it is in Executive mode 2, this procedure selects mode 0 (unlocked).
When Executive mode 2 is enabled and a front panel action is attempted (other than input switching, PIP enable or disable, swap, and Auto-Image), the LCD displays the lock status for 2 seconds.
Press and hold for about
2 seconds.
ADJUST
7
LCD screen displays
MENU
NEXT
DVS 605
DIGITAL VIDEO SCALER
either
EXEC. MODE 2
ENABLED
or
EXEC. MODE
DISABLED
2
Page 3
Conguring the DVS 605
2 sec.
2
.
640x480
z
z
OUTPU
0
2 sec.
DVS 605 devices can be configured by any of the following: via the front panel, the Extron Configurator software, via the internal web pages, or via RS-232/Ethernet or USB connection, using the Extron Simple Instruction Set (SIS) of commands (see rear page).
Front Panel Menu System
The scaler has seven front panel configuration menus:
•UserPresets•PictureControl•InputConguration•OutputConguration•AudioConguration•AdvancedConguration
•ViewCommSettings•ExitMenu.Ahiddenmenu(EditCommSettings)isalsoaccessible.
NOTE: To access the hidden Edit Comm Settings menu, press and hold the input 5 and the Next button simultaneously. Release
the buttons when the menu appears. Edit the setting as needed, then press Menu to exit and save the settings.
Default Display Cycle
#1
RGBHV
sec
720p@6
T
IN 31.47 kH #1 59.94 H
Menu
Next
Menu
USER
PRESETS
AUDIO
CONFIG
Menu
Menu
PICTURE CONTROL
ADVANCED
CONFIG
Menu
Menu
INPUT
CONFIG
VIEW COMM
SETTINGS
Menu
Menu
Menu
Menu
OUTPUT CONFIG
EXIT MENU?
PRESS NEXT
Next
To use any menu, press the Menu button to access the main menu, then repeatedly press the Menu button to cycle through to the desired menu. Press the Next button to enter and cycle through the desired submenu.
NOTE: Press Menu at any time to exit a submenu and return to the main menu.
For detailed information on the menus, see the DVS 605 User Guide, available online at www.extron.com.
To congure the DVS 605 using the front panel, follow the steps below:
1. Within the Output Configuration menu, use the Adjust knobs to select the output resolution and refresh rate, the output
signal type, and the sync polarity to match the requirements of the display device. The HDMI format can be set to match the connected HDMI display.
2. From the Advanced Configuration menu, Test Pattern submenu, select the Alternating Pixels (Alt. Pixels) test pattern.
Adjust the connected analog display's active pixels (size), total pixels (clocking), and pixel phase (fine sync) settings for optimal picture quality.
3. From the Advanced Configuration menu, change the test pattern to Crop, and adjust the display's position settings until
all four sides of the crop pattern are visible. Disable the test pattern. No further adjustments or Auto Images should be performed on the display device itself.
4. Use the Advanced Configuration menu to set the Aspect Ratio (Fill or Follow) for each input. Rotate either Adjust knob to
the desired setting.
5. Perform Auto-Image on each DVS 605 input. Auto-Image is a quick way to size an input to fit the current window size.
To perform Auto-Image on the current input, press the Auto-Image button, then press it again to confirm.
NOTE: Alternatively using the Input Configuration menu, make any desired advanced adjustments, including turning on or
off Film detection, Horizontal and Vertical Start, Active Lines, Pixel Phase, and EDID setting selection.
6. Adjust the Overscan mode under the Advanced Configuration menu as required. Overscan masks Closed Caption and
ancillary data common on broadcast signals. (Applies to SMPTE input resolutions only.)
7. Use the Picture Control buttons to adjust the Horizontal and Vertical Position and Size, Brightness and Contrast, Color and
Tint, and Detail settings if needed.
8. Use the User Presets menu to save the adjustments to each input for manual recall later.
Extron Congurator Software
To configure the unit using the Extron Configurator software, the software must be installed (from the included DVD or from
www.extron.com) on a PC connected to the DVS 605 via an RS-232 or a LAN connection, or via the front panel USB config port.
Installation creates a C:\Program Files\Extron\DVS 605 folder and installs the program, a help file, and an uninstall utility. After installation, start the program and either connect via the comm (RS-232) port, TCP/IP, or by USB. For full instructions press <F1> or click on Help>Contents.
Web pages
The DVS 605 can be configured, controlled, and operated through the Ethernet port when connected to a LAN or WAN, using a web browser such as Microsoft® Internet Explorer®. The browser displays the factory-installed web pages, which provide a means of viewing and operating the device. Access the HTML pages by entering the IP address of the unit in the browser Address field.
NOTE: If the system administrator has not changed it, DHCP is On (factory default setting).
If the unit is password-protected, enter the administrator or user password in the Password field. A user name entry is required. Enter admin for administrator level or user for user level (all lower case letters).
3
Page 4
DVS 605 • Setup Guide (Continued)
Upgrading the Firmware Using the Web Pages
The onboard firmware version of the DVS 605 unit can be upgraded via the factory-installed web pages when connected via the Ethernet port to a LAN or WAN, using a web browser such as Microsoft Internet Explorer.
Firmware upgrade files (with an EFF or ESS extension) for the DVS 605 unit are available at www.extron.com. At the website, browse to the file location and download the latest firmware version to a PC connected to the DVS 605.
Access the DVS 605 internal web pages by entering the IP address of the unit in the browser Address field. When the web pages open do the following:
1. Click the Hardware button above the global navigation bar.
2. Click the Firmware Loader icon on the global navigation bar. The Firmware Loader screen opens.
3. Click Browse. The Choose File to Upload dialog box opens.
4. Browse to and select the downloaded firmware file to upload to the device. Valid firmware files have an EFF or ESS extension.
5. Click Open. This closes the dialog box and returns you to the Firmware Loader screen.
6. Click Upload. Uploading progress is displayed and will indicate when completed.
7. When the upload is complete the unit reboots. Any IP connections to the unit will need to be re-established.
Basic SIS Commands Table
The DVS 605 can be configured with specific SIS commands via RS-232 or a LAN connection. This table lists a selection of the commands. For a full list of SIS commands and variables see the DVS 605 User Guide, online at www.extron.com.
Command ASCII command
(host to scaler)
Select video and audio input
Select video input
Select audio input
Execute Auto-Image Mute video to black
Mute video and output sync Unmute video PIP on
PIP off
Swap
Recall PIP preset (without input)
Recall PIP preset (with input) Save PIP preset Enable Executive mode 1 Enable mode 2 Disable Executive mode View front panel lock status
X!
! In
X!
& In
X!
$ In
0*A Img0 1B 2B Vmt2 0B
EX!PIP} PipX!] E0PIP} Pip0]
%
3*X2@ . 4*X2@ .
4*X2@ , 1X Exe1 2X Exe2 0X Exe0 X 0] (or 1
NOTE: Changes made to all Ethernet settings do not take effect until the reboot networking command (2BOOT) is issued.
Response
(scaler to host)
X!
]
All
X!
]
RGB
X!
]
Aud
]
]
Vmt1
]
]
Vmt0
]
Tke
3RprX2@] 4RprX2@]
4SprX2@]
] ] ]
]
)
(or 2])
Additional description
Selects video and audio from input X!.
Selects video only from input X!.
Selects audio only from input X!.
Executes Auto-Image for current input. Mutes video and display a black screen.
Mutes video and sync output. Unmutes video. Turns on PIP and displays input X!.
Turns off PIP.
Swaps inputs between main and PIP windows, or current and previous input when not in PIP mode.
Recalls PIP preset
Recalls PIP preset Saves PIP preset Locks out entire front panel. Allows limited front panel adjustments only. Allows all front panel adjustments and selections. Shows executive mode status.
X2@
without input.
X2@
with input.
X2@
.
Set DHCP to Off or On View DHCP status Set IP address View IP address Reboot network
NOTE:
Extron Headquarters
+1.800.633.9876 (Inside USA/Canada Only)
Extron Europe
+31.33.453.4040
X!
= Input number (1 – 5)
X2@
= PIP presets (1-16)
© 2012 Extron Electronics — All rights reserved. All trademarks mentioned are the property of their respective owners. www.extron.com
EX1&DH} IdhX1&] EDH} EX1(CI} ECI} X1(] E2BOOT}
X1&
Extron Asia
+65.6383.4400
Extron Japan
+81.3.3511.7655
4
Sets DHCP mode.
X1&] X1(]
Boot2]
= DHCP mode (0 = Off, 1 = On, default)
Shows DHCP setting. Sets IP address to Shows current IP address Restarts network after IP address or DHCP changes.
Extron China
+86.21.3760.1568)
Extron Middle East
+971.4.2991800
X1(
.
X1(
.
X1(
= IP address (such as 192.168.254.254)
Extron Korea
+82.2.3444.1571
Extron India
+91.80.3055.3777
68-2110-50
Rev. A 04 12
Loading...