www.extron.com
Device A
Device B
Female
9 pin D-sub
Male
9 pin D-sub
Female
9 pin D-sub
Female
9 pin D-sub
Tx
Tx
Rx
Rx
A Rx/B Tx
A Tx/B Rx
1
2
V
0
.5
A
M
A
X
L
A
N
C
O
M
1
PC Running Extron DataViewer Software
Projector
RS-232
Send
Receive
Extron IPL T S1
Ethernet Control Interface with GlobalViewer
software
Extron DVC-3
DataView Communication Cable
Device A
Device B
DVC-3 Data View Communications Cable
The Extron DVC-3 Data View Communications Cable can be inserted between two RS-232 devices for troubleshooting and monitoring (listening into) the serial communications between the two devices, without interrupting the communications. The DVC-3 Cable is terminated with female to male 9-pin D-sub connectors for data pass through, with two additional female 9-pin D-sub connectors used as the monitoring connections to your PC or laptop.
Using the cables
To use the Extron DVC-3 Data View Communications Cable, unplug the RS-232 cables between the host and controlled unit, and connect the DVC-3 cable labeled with “Device A” and “Device B” connectors. Connect one of the two monitoring cables to the PC or laptop. The monitoring cable used will depend on the communication line intended to be monitored. The connector labeled “A Tx/B Rx” is for monitoring the Tx (transmit) line of device A, which is also the Rx (receive) line of device B, and the cable labeled “A Rx/B Tx” is for monitoring the Rx (receive) line of device A, which is also the Tx (transmit) line of device B.
Figure 1 Typical DVC-3 application
The cable assembly has four 9-pin D-sub connectors, interconnected as shown below;