DTP T EU 4K 331
DTP T EU 4K 231
DTP T MK 4K 331
DTP T MK 4K 231
Digital Twisted Pair Transmitters for Extron
Flex55, EU- & MK- type junction boxes
User Guide
DTP Systems
68-2962-01 Rev. B
03 17
Page 2
Safety Instructions
Safety Instructions • English
WARNING:This symbol, , when used on the product, is intended to
alert the user of the presence of uninsulated dangerous voltage within
the product’s enclosure that may present a risk of electric shock.
ATTENTION: This symbol, , when used on the product, is intended
to alert the user of important operating and maintenance (servicing)
instructions in the literature provided with the equipment.
For information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the Extron Safety and
Regulatory Compliance Guide, part number 68-290-01, on the Extron
website, www.extron.com.
Sicherheitsanweisungen • Deutsch
WARNUNG: Dieses Symbol auf dem Produkt soll den Benutzer
darauf aufmerksam machen, dass im Inneren des Gehäuses dieses
Produktes gefährliche Spannungen herrschen, die nicht isoliert sind und
die einen elektrischen Schlag verursachen können.
VORSICHT: Dieses Symbol auf dem Produkt soll dem Benutzer in
der im Lieferumfang enthaltenen Dokumentation besonders wichtige
Hinweise zur Bedienung und Wartung (Instandhaltung) geben.
Weitere Informationen über die Sicherheitsrichtlinien, Produkthandhabung,
EMI/EMF-Kompatibilität, Zugänglichkeit und verwandte Themen finden Sie in
den Extron-Richtlinien für Sicherheit und Handhabung (Artikelnummer
68-290-01) auf der Extron-Website, www.extron.com.
Instrucciones de seguridad • Español
ADVERTENCIA: Este símbolo, , cuando se utiliza en el producto,
avisa al usuario de la presencia de voltaje peligroso sin aislar dentro del
producto, lo que puede representar un riesgo de descarga eléctrica.
ATENCIÓN: Este símbolo, , cuando se utiliza en el producto, avisa
al usuario de la presencia de importantes instrucciones de uso y
mantenimiento recogidas en la documentación proporcionada con el
equipo.
Para obtener información sobre directrices de seguridad, cumplimiento
de normativas, compatibilidad electromagnética, accesibilidad y temas
relacionados, consulte la Guía de cumplimiento de normativas y seguridad
de Extron, referencia 68-290-01, en el sitio Web de Extron, www.extron.com.
Instructions de sécurité • Français
AVERTISSEMENT : Ce pictogramme, , lorsqu’il est utilisé sur le
produit, signale à l’utilisateur la présence à l’intérieur du boîtier du
produit d’une tension électrique dangereuse susceptible de provoquer
un choc électrique.
ATTENTION : Ce pictogramme, , lorsqu’il est utilisé sur le produit,
signale à l’utilisateur des instructions d’utilisation ou de maintenance
importantes qui se trouvent dans la documentation fournie avec le
matériel.
Pour en savoir plus sur les règles de sécurité, la conformité à la
réglementation, la compatibilité EMI/EMF, l’accessibilité, et autres sujets
connexes, lisez les informations de sécurité et de conformité Extron, réf.
68-290-01, sur le site Extron, www.extron.com.
Istruzioni di sicurezza • Italiano
AVVISO: Questo simbolo, ,quando viene utilizzato il prodotto, serve
ad avvisare l’utente della presenza di tensioni pericolose non isolate
all’interno del prodotto, che può presentare un rischio di scosse
elettriche.
ATTENTZIONE: Questo simbolo, , quando viene utilizzato il
prodotto, serve ad avvisare l’utente di importanti istruzioni di uso e
manutenzione (assistenza) nella letteratura fornita con l’apparecchiatura.
Per informazioni sulle linee guida di sicurezza, adempimenti normativi,
compatibilità EMI/EMF, accessibilità e argomenti correlati, vedere la sicurezza
di Extron e Regulatory Compliance Guide, parte numero
68-290-01, sul sito Web Extron, www.extron.com.
Instrukcje bezpieczeństwa • Polska
OSTRZEŻENIE: Ten symbol, , gdy używany na produkt, ma na celu
poinformować użytkownika o obecności izolowanego i niebezpiecznego
napięcia wewnątrz obudowy produktu, który może stanowić zagrożenie
porażenia prądem elektrycznym.
UWAGI: Ten symbol, , gdy używany na produkt, jest przeznaczony do
ostrzegania użytkownika ważne operacyjne oraz instrukcje konserwacji
(obsługi) w literaturze, wyposażone w sprzęt.
Informacji na temat wytycznych w sprawie bezpieczeństwa, regulacji
wzajemnej zgodności, zgodność EMI/EMF, dostępności i Tematy pokrewne,
zobacz Extron bezpieczeństwa i regulacyjnego zgodności przewodnik, część
numer 68-290-01, na stronie internetowej Extron, www.extron.com.
Инструкция по технике безопасности • Русский
ПРЕДУПРЕЖДЕНИЕ: Данный символ, , если указан
на продукте, предупреждает пользователя о наличии
неизолированного опасного напряжения внутри корпуса
продукта, которое может привести к поражению электрическим
током.
ВНИМАНИЕ: Данный символ, , если указан на продукте,
предупреждает пользователя о наличии важных инструкций
по эксплуатации и обслуживанию в руководстве,
прилагаемом к данному оборудованию.
Для получения информации о правилах техники безопасности,
соблюдении нормативных требований, электромагнитной
совместимости (ЭМП/ЭДС), возможности доступа и других
вопросах см. руководство по безопасности и соблюдению
нормативных требований Extron на сайте Extron: ,
All trademarks mentioned in this guide are the properties of their respective owners.
The following registered trademarks®, registered service marks(SM), and trademarks(TM) are the property of RGBSystems, Inc. or Extron
Electronics (see the current list of trademarks on the
AVTrac, Cable Cubby, ControlScript, CrossPoint, DTP, eBUS, EDID Manager, EDID Minder, Flat Field, FlexOS, GlobalViewer, Global Configurator, Global
Scripter, Hideaway, Inline, IP Intercom, IP Link, Key Minder, LinkLicense, LockIt, MediaLink, MediaPort, NetPA, PlenumVault, PoleVault, PowerCage,
PURE3, Quantum, SoundField, SpeedMount, SpeedSwitch, System INTEGRATOR, TeamWork, TouchLink, V-Lock, VersaTools, VoiceLift, VN-Matrix,
WallVault, WindoWall, XTP, and XTP Systems
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part15 of the FCC rules. The ClassA limits provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause interference. This interference must be corrected at
the expense of the user.
ATTENTION:
• The Twisted Pair Extension technology works with shielded twisted pair (STP)
cables only. To ensure FCC Class A and CE compliance, STP cables and STP
connectors are also required.
• La technologie extension paires torsadées fonctionne avec les câbles paires
torsadées blindées(UTP) ou non blindées(STP) uniquement. Afin de s’assurer de
la compatibilité entre FCC ClasseA et CE, les câbles STP et les connecteurs STP
sont nécessaires.
• For more information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the “Extron Safety and
Regulatory Compliance Guide” on the Extron Website.
• Pour plus d'informations sur les directives de sécurité, les conformités de
régulation, la compatibilité EMI/EMF, l'accessibilité, et les sujets en lien, consultez
le «Informations de sécurité et de conformité Extron» sur le site internet
d'Extron.
Conventions Used in this Guide
Notifications
The following notifications are used in this guide:
CAUTION: Risk of minor personal injury.
ATTENTION : Risque de blessuremineure.
ATTENTION:
• Risk of property damage.
• Risque de dommages matériels.
NOTE: A note draws attention to important information.
Specifications Availability
Product specifications are available on the Extron website, www.extron.com.
Extron Glossary of Terms
A glossary of terms is available at http://www.extron.com/technology/glossary.aspx.
Troubleshooting — If no Image Appears ........... 15
vDTP T EU 4K 331, DTP T EU 4K 231, DTP T MK 4K 331, and DTP T MK 4K 231 • Contents
Page 6
DTP T EU 4K 331, DTP T EU 4K 231, DTP T MK 4K 331, and DTP T MK 4K 231 • Contentsvi
Page 7
Introduction
• About this Guide
• About the Transmitters
• Features
About this Guide
This guide describes the following wallplate-mounted transmitter models:
• DTP T EU 4K 331
• DTP T EU 4K 231
• DTP T MK 4K 331
• DTP T MK 4K 231
NOTE: In this guide:
• The units are commonly referred to as “transmitters.”
• Unless specifically identified by the model name, the discussions in the guide apply
to any model.
The transmitters output a signal to a compatible DTP receiver. This guide describes how to
install, operate, and configure the transmitter.
About the Transmitters
The transmitters covered in this guide are HDMI transmitters with DTP outputs (see
figure 1, on the next page). The transmitters are HDCP compliant, and support resolutions
up to 4k at 30 Hz with color space 4:4:4 or 4:2:2 and 4k at 60 Hz with color space 4:2:0.
Each transmitter converts one HDMI input, including embedded audio (or DVI video with
the appropriate adapter) to a proprietary digital signal. The transmitter and a compatible
DTP receiver extend the usable distance of video, audio, and control signals over a single
Extron XTP DTP 24 shielded twisted pair (STP) cable (recommended) or other STP cable.
The DTP T EU 4K 331 and DTP T MK 4K 331 are compatible with a DTP HDMI 330 Rx or
DTP DVI 330 Rx receiver, with a range of up 330 feet (100 meters).
The DTP T EU 4K 231 and DTP T MK 4K 231 are compatible with a DTP HDMI 230 Rx or
DTP DVI 230 Rx receiver, with a range of up 230 feet (70 meters).
The units consist of a device module that snaps into a plastic bezel faceplate. The
transmitters in the appropriate bezels fit into EU or MK one-gang junction boxes or
European cable channel systems, depending on the transmitter model. The products are
also compatible with the Extron Flex55 mounting system.
In most applications, a compatible receiver can power the transmitter through the STP
cable. An optional 12 VDC power supply can power the unit locally
DTP T EU 4K 331, DTP T EU 4K 231, DTP T MK 4K 331, and DTP T MK 4K 231 • Introduction1
Page 8
o
Display
RS-232HDMI
SIG LINK
POWER
12V
0.7A MAX
DTP IN
OUTPUTS
DTP CROSSPOINT 84 4K
100-240V ~ 1.6 A MAX
INPUTS
50-60 Hz
DTP HDMI 330 Rx
OUTPUTS
AUDIO
LR
Extron
DTP HDMI
4K 230 Rx
OVER DTP
IR
RS-232
TxRx Tx RxG
Receiver
CATx Cable
up to 230'
(70 m)
1
23A4A
123456
HDBT
3B
SIG LINK
XTP
DTP
OUT
Display
RS-232HDMI
SIG LINK
POWER
12V
0.7A MAX
DTP IN
CATx Cable
up to 330'
(100 m)
RS-232 IR
OVER TP
4B4
SIG LINK
OUT
G
7
SIG LINK
XTP
DTP
IN
Tx Rx Tx RxG
RS-232 IR
Tx Rx Tx Rx
Extron
TLP Pro 1020T
10" Ta bletop TouchLink
Pro Touchpanel
Doc
Tuner
1 2 3
VCRLaptop PC DVD
Cam
Tuner
321
654
987
Enter
December 15, 2013 - 7:58 AM
AV
LAN 1
LAN 2 LAN 3
+48V
1
2
3
4
Volume
Channel
Presets
Mute
Last
More
Presets
System
Audio
Control
Off
Ethernet
Ethernet
3
1
MIC/LINE
2
4
AMP OUTPUT
CLASS 2 WIRING
LR
LR4LR
AUDIO OUTPUTS
8Ω / 4Ω
1
LR
LR
1
2
3
Display
On
Off
Mute
Room
Control
0
Screen
Lighting
Help
OUTPUTS
DTP HDMI 330 Rx
AUDIO
LR
Extron
DTP HDMI
4K 330 Rx
OVER DTP
IR
RS-232
TxRx Tx RxG
Receiver
Outputs
Control
Network
COM 1COM 3COM 2 DIGITAL I/O
Tx Rx G Tx Rx G1234G
Tx Rx
RTSCTS
RESET
REMOTE
TxRx G
SIG LINK
IN
8
DTP
S/PDIF
OUT
XTP
DTP
HDBT
RS-232 IR
OVER TP
RS-232 IR
Tx Rx Tx RxG
G
IR/SERIALRELAYSDIGITAL I/O
CONTROL
12
R
SGSG
XTP
LINK
AUDIO INPUTS
DMP EXPANSION
EXP
C
12
34C+V
PWR OUT = 6W
LR
LR
1
3
2
LR4LR
+V D-S+S
LR
5
6
LR
Extron
Scaling Presentation Matrix Switcher
CATx Cable
up to 330'
HDMI IN
(100 m)
Extron
DTP T EU 4K 331
DTP Transmitter for
EU-type Junction Boxes
CATx Cable
up to 330'
HDMI IN
(100 m)
Extron
DTP T MK 4K 331
DTP Transmitter for
MK-type Junction Boxes
Microphones
DTP CrossPoint 84 4K IPCP SA
Audio
Audi
ExtronExtron
Extron
SM 26
Surface Mount
Speakers
Inputs
Figure 1. Typical Transmitter Application
DTP T EU 4K 331, DTP T EU 4K 231, DTP T MK 4K 331, and DTP T MK 4K 231 • Introduction2
Page 9
Features
• Transmits HDMI up to 330 feet (100 meters) (DTP T EU 4K 331 or
DTP T MK 4K 331) or 230 feet (70 meters) (DTP T EU 4K 231 or
DTP T MK 4K 231) over a single STP cable — The units provides high reliability and
maximum performance on an economical and easily installed cable infrastructure.
• Supports resolutions up to 4k30 with color space 4:4:4 or 4:2:2 and 4k60 with
color space 4:2:0
• The DTP output is compatible with HDBaseT-enabled devices — The DTP output
can be configured to send video and embedded audio to HDBaseT-enabled displays.
• Remotely powered by receiver — For simplified installation, only one power supply is
necessary to power both devices.
• Compatible with all DTP HDMI 330 (230) and DTP DVI 330 (230) receivers, and
DTP 330- (230-)enabled products — The transmitters can be used with the Extron
IN1608, DTP CrossPoint 84, and other DTP 330- (230-)enabled products to meet
application requirements.
DTP T EU 4K 331, DTP T EU 4K 231, DTP T MK 4K 331, and DTP T MK 4K 231 • Introduction3
Page 10
Installation and
Operation
This section contains information for mounting, connecting, and operating the
DTP T EU 4K 331, DTP T MK 4K 331, DTP T EU 4K 231, and DTP T MK 4K 231. Topics in
this section include:
• Installation Overview
• Installing the Junction Box or European Cable Channel System
• Installation Features
• Mounting the Transmitter
• Front Panel Connection
• Operation
• Troubleshooting — If no Image Appears
Installation Overview
All models can mount into junction boxes. The EU units mount into European junction boxes
and the MK units mount into MK junction boxes.
The DTP T EU 4K 331 and DTP T EU 4K 231 can mount into a European cable channel
system (also known as a “trunking system”). The products are also compatible with the
Extron Flex55 mounting options (see www.extron.com).
To mount and connect the transmitters, consider the following:
Ensure there is enough space between the rear panel and the back of the junction box
or European cable channel system to fit connectors. Figure 2, on the next page, shows
the dimensions of all transmitter models. The depth of all four transmitters is the same.
Allow at least 47 mm (1.9") in the junction box for the device plus cable clearance.
NOTE: The depth of the junction box or European cable channel system may vary.
If you are using a European cable channel system with a DTP T EU 4K 331 or
DTP T EU 4K 231, ensure the transmitter fits in the desired channel.
If necessary, prepare the mounting surface.
CAUTION: Failure to check the items listed below may result in personal injury or
property damage.
ATTENTION : La non-vérification des éléments listés ci-dessous peut provoquer
des blessures ou dommages matériels.
Ensure there are no utility cables or pipes at the intended location that might be
damaged or cause injury when installing the device.
Check that the installation meets the building, electrical, and safety codes.
DTP T EU 4K 331, DTP T EU 4K 231, DTP T MK 4K 331, and DTP T MK 4K 231 • Installation and Operation4
Page 11
`
(38.41 mm)
(8
MK Unit, Front
MK Unit, Side
3.169"
(80.50 mm)
3.386"
6.00 mm)
2.165"
(55.00 mm)
3.169"
(80.50 mm)
EU Unit, Front
2.165"
(55.00 mm)
2.165"
(55.00 mm)
2.165"
(55.00 mm)
0.398"
(10.10 mm)
(38.41 mm)
EU Unit, Side
0.394"
(10.00 mm)
1.800"
(45.72 mm)
Front, With Bezel
1.521"
Device Module
1.800"
(45.72 mm)
1.800"
(45.72 mm)
POWER
12V
0.7 A MAX
1.800"
(45.72 mm)
3.386"
(86.00 mm)
1.521"
(38.41 mm)
1.521"
Either Unit, Rear
Figure 2. Dimensions
Choose a location that allows cable runs without interference.
NOTE: Cables may need to be installed in the wall or conduits before the unit is
installed.
Install the junction box or European cable channel system (see Installing the Junction
Box or European Cable Channel System on page 6).
NOTE: Refer to the manufacturer for more junction box installation requirements.
Route and connect cables to the rear panel connectors (see Installation Features on
page 7).
Mount the unit into the junction box (see Mounting the Transmitter on page 12).
Connect input to the front panel connector (see Front Panel Connection on page 15).
DTP T EU 4K 331, DTP T EU 4K 231, DTP T MK 4K 331, and DTP T MK 4K 231 • Installation and Operation5
Page 12
Installing the Junction Box or European Cable Channel System
Refer to the junction box or European cable channel system manufacturer for additional
installation considerations. If required to cut an opening in the mounting surface, consider
the following:
• For accuracy, use a template or the mounting enclosure to mark cut guidelines.
• To avoid making the hole too big, cut inside the marked guidelines.
CAUTION: Smooth the edges of the opening to avoid personal injury during
installation and damage to the mounting device or the cables.
ATTENTION :
l’installation et d’endommager l’appareil de montage ou les câbles.
• Secure cables with clamps or ties to provide strain relief.
• Trim back and insulate shields with heat shrink.
ATTENTION:
• To prevent short circuits, the outer foil shield can be cut back to the point
where the cable exits the cable clamp. Both braided and foil shields should be
connected to an equipment ground at the other end of the cable.
• Afin d’éviter les court circuits, le blindage en aluminium extérieur peut être
réduit jusqu’à ce que le câble sorte de la cosse de câble. Le blindage tressé et
le blindage en aluminium devraient être connectés à la masse d’un équipement
à l’autre bout du câble.
Limez les bords de l’ouverture afin d’éviter toute blessure lors de
DTP T EU 4K 331, DTP T EU 4K 231, DTP T MK 4K 331, and DTP T MK 4K 231 • Installation and Operation6
Page 13
Installation Features
RearFront
DTP
HDTP
DTP
B
C
HDBT
Top
A
BDD
POWER
12V
HDMI IN
0.7 A MAX
E
Side
Figure 3. Installation Features
TP function switch (see below)
A
TP port(see page 8)
B
Power connector(see page 8)
C
Electrostatic ground point — Use the included grounding strap to ground the unit.
D
NOTE: This ground eliminates electrostatic discharge only. This is not an electrical
safety ground.
HDMI input port (see Front Panel Connection on page 15)
E
TP function switch — If the receiving device is in the Extron DTP series, use a
A
stylus or other tapered object to set this recessed switch to the DTP position. For
an HDBaseT-enabled receiver type, set this switch to the HDBT position. This
switch tailors the output signal as follows:
ATTENTION:
• Position this switch BEFORE connecting the appropriate device to the TP
connector. Failure to comply can damage the endpoint.
• Positionnez le sélecteur AVANT de connecter l’appareil approprié au
connecteur TP. Ne pas respecter cette procédure pourrait endommager le
point de connexion.
HDBT position — The TP output consists of HDMI with embedded audio.
DTP position — The TP output consists of HDMI with embedded audio and remote
power.
NOTES:
• When the switch is in the HDBT position, the transmitter and receiver each
requires a local 12 VDC power supply.
• When the switch is in the DTP position, one 12 VDC power supply,
connected to either the transmitter or the receiver, can power both units.
DTP T EU 4K 331, DTP T EU 4K 231, DTP T MK 4K 331, and DTP T MK 4K 231 • Installation and Operation7
Page 14
TP port (see figure 3 on the previous page) — Plug one end of a TP cable
0.7 A MAX
Side
Pair Wires
Pins:
Connector
B
into this RJ-45 female jack. Plug the opposite end into the DTP Input RJ-45
port on a compatible receiver (see “TP Cable Termination and
Recommendations” to wire the RJ-45 connector and for detailed NOTES).
Signal (green) LED — Lights when the transmitter outputs a video signal.
Link (yellow) LED — Lights when a device is connected and communicating.
ATTENTION:
• Do not connect this connector to a computer data or telecommunications
network.
• Ne connectez pas ces port à des données informatiques ou à un réseau de
télécommunications.
Power connector — When the TP function switch is in the DTP position, this
C
connector is probably not necessary. The connected receiving device can
remotely power the transmitter via the TP cable.
POWER
12V
ATTENTION:
• Remote power is intended for indoors use only. No part of a network that uses
remote power can be routed outdoors.
• L’alimentation à distance est exclusivement réservée à un usage en intérieur.
Un réseau utilisant une alimentation à distance ne peut pas être routé en extérieur.
If the TP function switch (item A on the previous page) is in the HDBT position, or if
otherwise desired, plug an optional external 12 VDC power supply into this 2-pole direct
insertion connector (see Power Supply Wiring on page 10).
NOTE: When the TP function switch is in the DTP position, one power supply
can power both units.
When the TP function switch is in the HDBT position, the transmitter
and receiver each requires a local 12 VDC power supply.
HDMI input port (see Front Panel Connection on page 15)
E
Connection and Wiring Details
TP Cable Termination and Recommendations
Figure 4 details the TIA/EIA-T568B wiring standard. Use this standard to terminate the DTP
cable with RJ-45 connectors.
Figure 4. TP Cable Termination
DTP T EU 4K 331, DTP T EU 4K 231, DTP T MK 4K 331, and DTP T MK 4K 231 • Installation and Operation8
12345678
Insert
Twisted
Pin
White-orange
1
Orange
2
3
White-green
4
Blue
5
White-blue
6
Green
7
White-brown
8
Brown
RJ-45
TIA/EIA T
568 B
Wire color
Page 15
NOTE: Do not use Extron UTP23SF-4 Enhanced Skew-Free AV UTP cable or STP201
cable to link the transmitter and receiver. The DTP T EU and DTP T MK units do not
work properly with these cables.
Supported cables
The DTP units are compatible with shielded twisted pair (STP) and unshielded twisted pair
(U/UTP) cable. However, Extron strongly recommends that you use STP cable to achieve
best performance.
ATTENTION:
• To ensure FCC Class A and CE compliance, STP cables and STP connectors are
required.
• Afin de s’assurer de la compatibilité entre FCC ClasseA et CE, les câbles STP et
les connecteurs STP sont nécessaires.
Cable recommendations
Extron recommends using the following practices to achieve full transmission distances up
to 330 feet (100 meters) (DTP T EU 4K 331 and DTP T MK 4K 331) or 230 feet (70 meters)
(DTP T EU 4K 231 and DTP T MK 4K 231) and reduce transmission errors.
• Use the following Extron XTP DTP 24 STP cables and DTP 24 connectors for the best
• If not using XTP DTP 24 cable, at a minimum, Extron recommends 24 AWG, solid
conductor, STP cable with a minimum bandwidth of 400 MHz.
• Terminate cables with shielded connectors to the TIA/EIA-T568B standard.
• Use no more than two pass-through points, which may include patch points, punch
down connectors, couplers, and power injectors. If these pass-through points are
required, use CAT 6 or 6a shielded couplers and punch down connectors.
NOTE: When using STP cable in bundles or conduits, consider the following:
• Do not exceed 40% fill capacity in conduits.
• Do not comb the cable for the first 20 meters, where cables are straightened,
aligned, and secured in tight bundles.
• Loosely place cables and limit the use of tie wraps or hook-and-loop fasteners.
• Separate twisted pair cables from AC power cables.
DTP T EU 4K 331, DTP T EU 4K 231, DTP T MK 4K 331, and DTP T MK 4K 231 • Installation and Operation9
Page 16
Power Supply Wiring
Power Supply
Output Cord
Direct Insertion
Connector
SECTION A–A
Ridges
Smooth
AA
3
5
1.0 A MAX
12V
0.7 A MAX
POWER
12V
NOTE: The transmitter normally receives power from the receiver. A power supply is not
included with the transmitter. This section is for wiring an optional power supply.
Figure 5 shows how to wire the connector.
Figure 5. Power Connector Wiring
CAUTION:
ATTENTION :
• The wires must be kept separate while the power supply is plugged in. Remove
power before wiring.
• Les deux cordons d’alimentation doivent être maintenus séparés lorsque la
source d’alimentation est branchée. Coupez l’alimentation avant d’effectuer un
raccordement.
• The length of exposed wires is important. The ideal length is 3/16 inch (5 mm).
• Any longer and the exposed wires may touch, causing a short circuit between
them.
• Any shorter and the wires can be easily pulled out even if tightly fastened by the
captive screws.
• La longueur des câbles exposés est importante. La longueur idéale est de 5mm
(3/16inches).
• S’ils sont trop longs, les câbles exposés pourraient se toucher et provoquer un
court-circuit.
• S’ils sont trop courts, ils peuvent être tirés facilement, même s’ils sont
correctement serrés par les borniers à vis.
• Do not tin the power supply leads before installing them in the connector. Tinned
wires are not as secure in the connector and could be pulled out.
• Ne pas étamer les conducteurs avant de les insérer dans le connecteur. Les câbles
étamés ne sont pas aussi bien fixés dans le connecteur et pourraient être retirés.
DTP T EU 4K 331, DTP T EU 4K 231, DTP T MK 4K 331, and DTP T MK 4K 231 • Installation and Operation10
Page 17
ATTENTION:
• If not provided with a power supply, this product is intended to be supplied by a UL
Listed power source marked “Class 2” or “LPS” and rated output 12V dc, minimum
1.0 A minimum. Always use a power supply supplied by or specified by Extron. Use
of an unauthorized power supply voids all regulatory compliance certification and
may cause damage to the supply and the end product.
• Si le produit n’est pas fourni avec une source d’alimentation, il doit être alimenté
par une source d’alimentation certifié UL de classe 2 ou LPS, avec une tension
nominale 12 Vcc, 1 A minimum. Utilisez toujours une source d’alimentation
fournie ou recommandée par Extron. L’utilisation d’une source d’alimentation non
autorisée annule toute conformité réglementaire et peut endommager la source
d’alimentation ainsi que le produit final.
• Unless otherwise stated, the AC/DC adapters are not suitable for use in air handling
spaces or in wall cavities.
• Sauf mention contraire, les adaptateurs CA/CC ne conviennent pas à une utilisation
dans les espaces d’aération ou dans les cavités murales.
• The installation must always be in accordance with the applicable provisions of
National Electrical Code ANSI/NFPA 70, article 725 and the Canadian Electrical
Code part 1, section 16. The power supply shall not be permanently fixed to a
building structure or similar structure.
• Cette installation doit toujours conforme aux dispositions applicables du Code
américain de l’électricité (National Electrical Code) ANSI/NFPA 70, article 725, et
du Code canadien de l’électricité, partie1, section16. La source d’alimentation ne
devra pas être fixée de façon permanente à une structure de bâtiment ou à une
structure similaire.
• Power supply voltage polarity is critical. Incorrect voltage polarity can damage the
power supply and the unit. The ridges on the side of the cord (see figure 5 on the
previous page) identify the power cord negative lead.
• La polarité de la source d’alimentation est primordiale. Une polarité incorrecte
pourrait endommager la source d’alimentation et l’unité. Les stries sur le côté du
cordon (voir l’illustration 5 sur la page 10) permettent de repérer le pôle négatif du
cordon d’alimentation.
To verify the polarity before connection, plug in the power supply with no load and check the
output with a voltmeter.
DTP T EU 4K 331, DTP T EU 4K 231, DTP T MK 4K 331, and DTP T MK 4K 231 • Installation and Operation11
Page 18
Mounting the Transmitter
EU MountingMK Mounting
ATTENTION:
• Ensure that the junction box is grounded properly.
• Assurez vous que le boîtier d’encastrement est correctement mis à la terre.
Mount the transmitter to a junction box as follows:
1. Disconnect power from all devices at the source.
2. Orient the mounting bracket as appropriate for your transmitter (see figure 6):
• MK mounting — The word “Front” engraved on the bracket reads vertically.
• EU mounting — “Front” reads horizontally.
MK Wall Box
EU Wall Box
EU Mounting Bracket
MK Mounting Bracket
Figure 6. Mounting the Transmitter to a Junction Box
3. Fasten the provided metal mounting bracket to the mounted junction box, in the proper
orientation, using the two included screws.
NOTES:
• To keep the transmitter securely in place and prevent it from being easily pulled
from its mounting surface, ensure that the side of the bracket with the word
“Front” engraved on it faces out (away from the junction box).
• If you want to be able to remove the transmitter easily from its mounting, attach
the mounting bracket with “Front” facing inward, toward the junction box.
4. Run the TP cable and optional power cable through the junction box and the plastic
bezel frame.
5. Set the TP function switch to the appropriate position (see item A on page 7).
6. Connect the rear panel cables to the transmitter.
7. Align the bezel frame to the metal mounting bracket on the mounting surface.
8. Holding the bezel frame in place on the bracket, press the transmitter into the frame
until the unit snaps into place and all four tabs on the unit snap into their slots.
Bezel Frame
DTP T EU
DTP T EU 4K 331, DTP T EU 4K 231, DTP T MK 4K 331, and DTP T MK 4K 231 • Installation and Operation12
Page 19
Mounting an EU transmitter in a Raceway Using Spacers (Optional)
Mounting Bra
Raceway
J
If the EU transmitter does not stay in place when installed in
a cable raceway, this may be due to a gap between the
metal mounting bracket and the bezel frame. When this gap
exists, the tabs on the sides of the transmitter do not reach
the metal mounting bracket and the transmitter does not
snap completely into the mounting bracket.
You can fix this problem by installing a spacer (provided with
the EU transmitter) between the metal mounting bracket
and the rim of the junction box. This spacer is engraved
with the words “Optional Spacer” and “Place behind
bracket” and has a slightly larger center opening than the mounting bracket.
NOTE: Do not attempt to use the spacer in place of the metal mounting bracket.
Because of its larger opening, the spacer cannot hold the EU transmitter in place.
To mount the transmitter EU to a raceway using the spacer:
1. Disconnect power from all devices at the source.
2. Mount the junction box in the raceway.
3. Attach the spacer to the junction box using two of the included screws in the holes
at the sides of the spacer. Leave the screw heads protruding approximately 1/8 inch
(3.175 mm) from the surface of the spacer (see figure 7).
Junction Box
cket
Spacer
unction Box
Spacer
Metal Bracket
Bezel Frame
Cable Raceway
Figure 7. Mounting the EU Transmitter Using a Spacer
4. With the “Front” marking toward you (away from the spacer and junction box), place the
metal mounting bracket onto the spacer so that the screw heads pass through two of
the slotted holes in opposite sides of the bracket.
5. Rotate the mounting bracket as necessary to ensure that the transmitter will be
positioned straight on the mounting surface and not skewed to either side.
6. Tighten the screws to secure the bracket to the spacer.
7. Pull the TP cable and optional power cable through the junction box and the plastic
bezel frame and connect them to the transmitter.
8. Align the bezel frame with the metal mounting bracket on the mounting surface.
9. Press the transmitter into the frame until the unit snaps into place.
DTP T EU 4K 331, DTP T EU 4K 231, DTP T MK 4K 331, and DTP T MK 4K 231 • Installation and Operation13
DTP T EU
Page 20
Removing the Transmitter (Accessing the Side and Rear Features)
e.
To access the transmitter side and rear panel features after the transmitter has been
mounted, you must use a removal tool (included, shown at right) to remove the
transmitter from the installation surface.
Remove the transmitter from the mounting surface as follows:
1. Insert the flat tip of the removal tool in the center of the right or left edge of the
transmitter, between the unit and the wall frame, all the way to the line below the arrow
on the tool (see figure 8).
Extron
Extron
Insert to lin
Figure 8. Inserting the Removal Tool in a Transmitter
2. Gently press the removal tool either inward or outward to release the tab holding the
transmitter in place in the wall frame.
3. If the transmitter does not immediately come free of the bezel frame, pry the unit
outward (away from the wall) until it is free of the installation surface, then lift it out,
leaving the metal mounting bracket attached.
NOTE: Without the transmitter to hold the bezel frame in place, the frame is also
removed.)
To reinstall the transmitter, hold the bezel frame in place on the bracket and press the
transmitter into the frame until the unit snaps into place and all four tabs on the unit snap
into their slots.
DTP T EU 4K 331, DTP T EU 4K 231, DTP T MK 4K 331, and DTP T MK 4K 231 • Installation and Operation14
Page 21
Front Panel Connection
B
A
HDMI IN
Figure 9. Front Panel HDMI Connection and Indicator
HDMI IN
HDMI input port — Connect a digital video source to the transmitter via
A
this HDMI connector. It accepts HDMI, and can also accept a DVI or dual
mode DisplayPort video source with an appropriate adapter.
NOTE: The maximum HDMI cable length is 4.5 m (15 feet).
Operation
Plug in all system components and turn on the input device (such as a Blu-Ray player or
computer) and the output device. Set the input devices to output video using the operating
instructions of that device. The image should appear on the screen. If no image appears,
see “Troubleshooting — If no Image Appears,” below.
Indications
Power ( ) LED — Lights to indicate power and signal status:
B
Amber — The transmitter is receiving power from either the connected DTP receiver or
a local power supply. No digital video signal is input.
Green — The transmitter is receiving power and is detecting TMDS on the HDMI input
connector.
Troubleshooting — If no Image Appears
1. Ensure that all devices are plugged in and powered on.
2. Ensure an active input is applied to the transmitter. The transmitter is receiving an active
input if the power LED is lit green.
3. Ensure that the proper signal format is supplied.
4. Check the cabling and make corrections as necessary.
5. Call the Extron S3 Sales & Technical Support Hotline if necessary. See the end of this
guide for the phone number in your region of the world.
DTP T EU 4K 331, DTP T EU 4K 231, DTP T MK 4K 331, and DTP T MK 4K 231 • Installation and Operation15
Page 22
Extron Warranty
Extron Electronics warrants this product against defects in materials and workmanship for a period of three years
from the date of purchase. In the event of malfunction during the warranty period attributable directly to faulty
workmanship and/or materials, Extron Electronics will, at its option, repair or replace said products or components,
to whatever extent it shall deem necessary to restore said product to proper operating condition, provided that it is
returned within the warranty period, with proof of purchase and description of malfunction to:
USA, Canada, South America,
and Central America:
Extron Electronics
1230 South Lewis Street
Anaheim, CA 92805
U.S.A.
Europe and Africa:
Extron Europe
Hanzeboulevard 10
3825 PH Amersfoort
The Netherlands
Japan:
Extron Electronics, Japan
Kyodo Building, 16 Ichibancho
Chiyoda-ku, Tokyo 102-0082
Japan
China:
Extron China
686 Ronghua Road
Songjiang District
Shanghai 201611
China
Asia:
Extron Asia Pte Ltd
135 Joo Seng Road, #04-01
PM Industrial Bldg.
Singapore 368363
Middle East:
Extron Middle East
Dubai Airport Free Zone
F13, PO Box 293666
United Arab Emirates, Dubai
Singapore
This Limited Warranty does not apply if the fault has been caused by misuse, improper handling care, electrical
or mechanical abuse, abnormal operating conditions, or if modifications were made to the product that were not
authorized by Extron.
NOTE: If a product is defective, please call Extron and ask for an Application Engineer to receive an RA (Return
Authorization) number. This will begin the repair process.
USA: 714.491.1500 or 800.633.9876 Europe: 31.33.453.4040
Asia: 65.6383.4400 Japan: 81.3.3511.7655
Units must be returned insured, with shipping charges prepaid. If not insured, you assume the risk of loss or damage
during shipment. Returned units must include the serial number and a description of the problem, as well as the
name of the person to contact in case there are any questions.
Extron Electronics makes no further warranties either expressed or implied with respect to the product and its quality,
performance, merchantability, or fitness for any particular use. In no event will Extron Electronics be liable for direct,
indirect, or consequential damages resulting from any defect in this product even if Extron Electronics has been
advised of such damage.
Please note that laws vary from state to state and country to country, and that some provisions of this warranty may
not apply to you.
Extron Headquarters
+1.800.633.9876 (Inside USA/Canada Only)
Extron USA - West Extron USA - East
+1.714.491.1500 +1.919.850.1000
+1.714.491.1517 FAX +1.919.850.1001 FAX