Extron electronics DTP T 3G-SDI 230 D, DTP T 3G-SDI 330 D Setup Manual

DTP T 3G-SDI D Series • Setup Guide
Front Panel
Rear Panel
Wall Stud
Screws
or Nails
Signal Output Cable
Decorator-Style Faceplate
Extron DTP T 3G-SDI 330 D
E
OVER TP
RS-232 IR
Tx
L O O P
T H R U
AUDIO IN
3G-SDI IN
Rx TxRxG
This setup guide provides instructions for an experienced installer to set up and operate the Extron DTP T 3G-SDI D series of SDI extenders. The DTP T 3G-SDI 230 D and DTP T 3G-SDI 330 D products can transmit video, control, and audio (if applicable) signals up to 230 feet (70 meters) and 330 feet (100 meters), respectively.
A SDI Input connector B SDI Loop Thru connector C Audio Input connector
D RS-232 and IR Over TP connector (page 2) E USB Config port (page 2) F TP Out connector (page 2) G Power input connector (page 2) H Power LED (page 3)
H A
B
L O O P
T H R U
3G/SDI IN
AUDIO IN
OVER TP
IR
RS-232
1.0A MAX 12V
POWER
+–
G
C
CONFIG
E
Tx TxRx RxG
F
D
OUT
DTP T 3G-SDI 330 D
Installation
Step 1 — Prepare the Mounting Surface
Step 2 — Disconnect Power
Disconnect all equipment from power sources.
DTP T 3G-SDI 230/330 D
DTP T 3G-SDI 230/330 D
NOTE: Use a UL-listed junction box with a depth of at least
3.0 inches (7.6 cm). Alternatively, the included mud ring (MR 100) can be used. For more information, see the full product user guide at
www.extron.com. The installation must comply with the
National Electrical Code and all applicable local codes.
a. Place the junction box against the installation surface and
mark the opening guidelines.
b. Cut out the material from the marked area.
c. Secure the junction box with 10-penny nails or #8 or #10 screws, leaving the front edge ush with the surface.
d. Run all required cables (see steps 4, 5, and 6) and secure them with cable clamps.
TIP: To ensure a proper t the unit in the junction box, do not install boots on TP cables and RJ-45 connectors.
Step 3 — Connect Rear Panel Inputs to the Transmitter
A SDI input connector — Connect a coaxial cable to the output port of the SDI or HD-SDI video source. B SDI Loop Thru connector — Connect a display to this BNC loop-through connector for local monitoring.
C Audio input connector — Connect an unbalanced stereo audio source to this 3.5 mm mini stereo jack.
NOTES:
The DTP T 3G-SDI D series of products do not embed this audio onto the SDI signal. Audio is transported
AES/EBU digital audio is passed through with the supported SDI format.
separately over the DTP connection.
DTP T 3G-SDI D Series • Setup Guide (Continued)
Output Cord
D RS-232 and IR Over TP — Plug an RS-232 or modulated IR device into
this RS-232 and IR Over TP pass-through port. Wire the cable as shown to the right.
E USB Config port — Connect a PC to this USB mini-B port for device
conguration and rmware updates.
RS-232
IR
OVER TP
Tx TxRx RxG
Connected RS-232 and IR Device Pins
Receive pin on connected unit Transmit pin on connected unit Ground Receive pin on connected unit Transmit pin on connected unit
F TP Out connector — Connect the rear panel transmitter output (see
on page 1) to the rear panel receiver input using
F
shielded twisted pair (STP) cable.
ATTENTION:
Do not connect these outputs to a telecommunications or computer data network.
Ne connectez pas ces appareils à des données informatiques ou à un réseau de télécommunications.
Do not use Extron UTP23SF-4 Enhanced Skew-Free AV UTP cable or STP201 cable.
N’utilisez pas le câble AV Skew-FreeUTP version améliorée UTP23SF d’Extron ou le câble STP201.
For optimal performance, Extron highly recommends the following:
RJ-45 termination with STP cable must comply with TIA/EIA T568-B wiring standard for all connections. For more
information on cable wiring and termination, see the full product user guide at www.extron.com.
Use shielded twisted pair cable, 24 AWG solid conductor or better, with a minimum cable bandwidth of 400 MHz.
Use shielded RJ-45 plugs to terminate the cable.
Limit the use of RJ-45 patches. Overall transmission distance capabilities vary
depending on the number of patches used. If possible, limit the number of patches to a maximum of 2.
If RJ-45 patches must be used in the system, shielded CAT 6 (or better) patches
are recommended.
Smooth
3/16"
(5 mm) Max.
Ridges
AA
G Power input connector — Plug the included external 12 VDC power supply into
either this 2-pole connector (see the illustration to the right for wiring information) or the power input connector on the receiver (see the user guide of your respective receiver for more information).
The unit can be powered either locally, with the included external 12 VDC power supply, or over the DTP line by a locally powered receiver or switcher.
SECTION A–A
Power Supply
Captive Screw
Connector
ATTENTION:
Extron recommends installing the DTP T 3G-SDI D into a grounded, UL-listed electrical junction box.
Extron recommande d’installer le DTP T 3G-SDI D dans un boîtier d’encastrement électrique mis à la terre,
listé UL.
Step 4 — Connect Outputs from the Receiver
The DTP T 3G-SDI D series is compatible with DTP 230 and DTP 330 receivers (sold separately).
a. Output connector — Connect a DisplayPort or HDMI cable between this port and the input port of the display. For
complete instructions on connecting receivers or switchers to outputs, see the user guide for the appropriate product at
www.extron.com.
b. Audio output — Connect a stereo audio device to this 3.5 mm mini stereo jack to receive the passed through
unbalanced audio.
c. RS-232 and IR Over TP connector — Plug an RS-232 or modulated IR device into the RS-232 and IR Over TP
pass-through port. Wire the connector as shown in step 3 above.
Step 5 — Final Installation
a. Make all connections and test the system for satisfactory operation.
b. At the power outlet, unplug the power supply.
c. Mount the transmitter into the wall box and attach the supplied decorator-style faceplate to the unit.
d. At the power outlet, reconnect the power supply. This can power up both the transmitter and receiver.
2