Extron® Shielded DTP RJ-45 Plug for DTP26 Cable Termination Kit
Strip 1.25" from
Fold back braid
The Extron Shielded DTP RJ-45 Connector kit terminates shielded CAT 5e, CAT 6e, CAT 7, and DTP26 cable. The connector can accommodate solid and stranded conductors with an outside diameter in the range of 0.037 to 0.042 inches.
The kit contains connectors and guides and provides a method to complete a fully shielded cable assembly. To terminate shielded cable, follow these steps:
1. Optional: Slide a strain relief or heat shrink over the cable. The strain relief and heat
shrink are not included.
cable jacket.
Braid Shield
Foil Shield
3. Strip approximately 0.8 inches (20.3 mm) of foil shielding from the end of the cable
(CAT 7 and DTP26 cables only).
4. Separate the four exposed twisted pair wires and trim (but do not strip) the wires to
0.8 inches (20.3 mm).
Tr im to .80”
(conductors)
12345678
Untwist and Arrange in Order
5. Arrange and lay flat the eight wires in the correct order to
comply with TIA/EIA 568A or 568B wiring standard (see the chart at right). The cables shown in this guide comply with the 568A standard.
NOTES: Plenum cable does not have a stripe
on the white conductor. Use the foil shield to identify and group the colored conductors.
The cables must be terminated to one
Pin
568 A 568 B
White-green
1
Green
2
White-orange
3
Blue
4
White-blue
5
Orange
6
White-brown
7
Brown
8
White-orange
Orange
White-green
Blue
White-blue
Green White-brown Brown
of these wiring standards at each end. Straight-through cables must be terminated to the same standard at each end. The figures in this guide show the 568A standard.
6. Turn the cable over and flatten the braid against the bottom of the cable.
87654321
NOTE: In figure above, the cable is viewed from beneath, so wires are in reverse
order.
Extron® Shielded DTP RJ-45 Plug for DTP26 Cable Termination Kit (continued)
0.3"
S
7. Feed the individual wires, in the correct order, through the open front face of the
plastic guide and out through the individual holes at the rear. The rear of the guide should be seated against the end of the foil shield with CAT 7 or DTP26 cables and against the braid for all other types of twisted pair cables.
Heat Shrink Tubing or Strain Relief (Optional)
Insert wires through the open front face and out through the holes in the rear face of the guide.
8. Cut the wires to 0.3 inches (7.6 mm), as shown in the figure below. The total length of
exposed wire should not exceed 0.6 inches (15.2 mm).
9. Insert the guide and wires into the RJ-45 connector, making sure the wires pass the
crimping teeth of the connector.
Guide (rear face shown)
Strain Relief
train Relief
Insert into RJ-45 Connector
NOTE: Ensure the wires are in the correct order (see chart on previous page) and
the bottom of the connector is next to the braid shield that was folded under the cable in step 6.
10. Insert the connector into the termination tool and crimp it to secure the connector to
the cable. Use pliers to secure the connector tabs around the cable and the ground.
Crimp connector.
NOTE:
Ensure conductors are
Connector Tab
seated properly under contacts.
NOTE: To ensure correct grounding throughout the cable, the braid shield, folded
back in step 6, must make contact with the shielded RJ-45 connector on both ends of the cable.
11. If a strain relief is present, slide it forward to cover the cable and the first 0.4 inches
(10.2 mm) of the RJ-45 connector.
12. Test both ends of the cable for conductivity.
Extron USA - West Headquarters
+800.633.9876
Inside USA and Canada Only
+1.714.491.1500 +1.714.491.1517 FAX
Extron USA - East
+800.633.9876
Inside USA and Canada Only
+1.919.863.1794 +1.919.863.1797 FAX
Extron Europe
+800.3987.6673
Inside Europe Only
+31.33.453.4040 +31.33.453.4050 FAX
Extron Asia
+800.7339.8766
Inside Asia Only
+65.6383.4400 +65.6383.4664 FAX
Extron Japan
+81.3.3511.7655 +81.3.3511.7656 FAX
© 2010 Extron Electronics All rights reserved. www.extron.com
Extron China
+400.883.1568
Inside China Only
+86.21.3760.1568 +86.21.3760.1566 FAX
Extron Middle East
+971.4.2991800 +971.4.2991880 FAX
68-1813-01 Rev.
C
11 10
Loading...