User’s Manual
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201 Fax 07131 911203
ce-info@camboard.de
Extron Electronics, USA
1230 South Lewis Street Anaheim, CA 92805
800.633.9876 714.491.1500
www.extron.com
FAX 714.491.1517
Extron Electronics, Europe
Beeldschermweg 6C 3821 AH Amersfoort, The Netherlands +800.3987.6673 +31.33.453.4040 FAX +31.33.453.4050
© 2007 Extron Electronics. All rights reserved.
Extron Electronics, Asia
135 Joo Seng Rd. #04-01 PM Industrial Bldg., Singapore 368363 +800.7339.8766 +65.6383.4400 FAX +65.6383.4664
Extron Electronics, Japan
Kyodo Building, 16 Ichibancho Chiyoda-ku, Tokyo 102-0082 Japan +81.3.3511.7655 FAX +81.3.3511
CVEQ 100 and SVEQ 100
1-Input, 1-Output Equalizing Composite
Video and S-Video Line Drivers
68-1252-01 Rev. B
01 07
Page 2
Precautions
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201 Fax 07131 911203
ce-info@camboard.de
Safety Instructions • English
This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment.
This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product’s enclosure that may present a risk of electric shock.
Caution
Read Instructions • Read and understand all safety and operating
instructions before using the equipment.
Retain Instructions • The safety instructions should be kept for future
reference.
Follow Warnings • Follow all warnings and instructions marked on the
equipment or in the user information.
Avoid Attachments • Do not use tools or attachments that are not
recommended by the equipment manufacturer because they may be hazardous.
Consignes de Sécurité • Français
Ce symbole sert à avertir l’utilisateur que la documentation fournie avec le matériel contient des instructions importantes concernant l’exploitation et la maintenance (réparation).
Ce symbole sert à avertir l’utilisateur de la présence dans le boîtier de l’appareil de tensions dangereuses non isolées posant des risques d’électrocution.
Attention
Lire les instructions• Prendre connaissance de toutes les consignes de
sécurité et d’exploitation avant d’utiliser le matériel.
Conserver les instructions• Ranger les consignes de sécurité afi n de pouvoir
les consulter à l’avenir.
Respecter les avertissements • Observer tous les avertissements et consignes
marqués sur le matériel ou présentés dans la documentation utilisateur.
Eviter les pièces de fi xation • Ne pas utiliser de pièces de fi xation ni d’outils
non recommandés par le fabricant du matériel car cela risquerait de poser certains dangers.
Sicherheitsanleitungen • Deutsch
Dieses Symbol soll dem Benutzer in der im Lieferumfang enthaltenen Dokumentation besonders wichtige Hinweise zur Bedienung und Wartung (Instandhaltung) geben.
Dieses Symbol soll den Benutzer darauf aufmerksam machen, daß im Inneren des Gehäuses dieses Produktes gefährliche Spannungen, die nicht isoliert sind und die einen elektrischen Schock verursachen können, herrschen.
Achtung
Lesen der Anleitungen • Bevor Sie das Gerät zum ersten Mal verwenden,
sollten Sie alle Sicherheits-und Bedienungsanleitungen genau durchlesen und verstehen.
Aufbewahren der Anleitungen • Die Hinweise zur elektrischen Sicherheit
des Produktes sollten Sie aufbewahren, damit Sie im Bedarfsfall darauf zurückgreifen können.
Befolgen der Warnhinweise • Befolgen Sie alle Warnhinweise und
Anleitungen auf dem Gerät oder in der Benutzerdokumentation.
Keine Zusatzgeräte • Verwenden Sie keine Werkzeuge oder Zusatzgeräte,
die nicht ausdrücklich vom Hersteller empfohlen wurden, da diese eine Gefahrenquelle darstellen können.
Instrucciones de seguridad • Español
Este símbolo se utiliza para advertir al usuario sobre instrucciones importantes de operación y mantenimiento (o cambio de partes) que se desean destacar en el contenido de la documentación suministrada con los equipos.
Este símbolo se utiliza para advertir al usuario sobre la presencia de elementos con voltaje peligroso sin protección aislante, que puedan encontrarse dentro de la caja o alojamiento del producto, y que puedan representar riesgo de electrocución.
Precaucion
Leer las instrucciones • Leer y analizar todas las instrucciones de operación y
seguridad, antes de usar el equipo.
Conservar las instrucciones • Conservar las instrucciones de seguridad para
futura consulta.
Obedecer las advertencias • Todas las advertencias e instrucciones marcadas
en el equipo o en la documentación del usuario, deben ser obedecidas.
Evitar el uso de accesorios • No usar herramientas o accesorios que no
sean especifi camente recomendados por el fabricante, ya que podrian implicar riesgos.
Warning
Power sources • This equipment should be operated only from the power source
indicated on the product. This equipment is intended to be used with a main power system with a grounded (neutral) conductor. The third (grounding) pin is a safety feature, do not attempt to bypass or disable it.
Power disconnection • To remove power from the equipment safely, remove all power
cords from the rear of the equipment, or the desktop power module (if detachable), or from the power source receptacle (wall plug).
Power cord protection • Power cords should be routed so that they are not likely to be
stepped on or pinched by items placed upon or against them.
Servicing • Refer all servicing to qualifi ed service personnel. There are no user-
serviceable parts inside. To prevent the risk of shock, do not attempt to service this equipment yourself because opening or removing covers may expose you to dangerous voltage or other hazards.
Slots and openings • If the equipment has slots or holes in the enclosure, these are
provided to prevent overheating of sensitive components inside. These openings must never be blocked by other objects.
Lithium battery • There is a danger of explosion if battery is incorrectly
replaced. Replace it only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions.
Avertissement
Alimentations• Ne faire fonctionner ce matériel qu’avec la source d’alimentation
indiquée sur l’appareil. Ce matériel doit être utilisé avec une alimentation principale comportant un fi l de terre (neutre). Le troisième contact (de mise à la terre) constitue un dispositif de sécurité : n’essayez pas de la contourner ni de la désactiver.
Déconnexion de l’alimentation• Pour mettre le matériel hors tension sans danger,
déconnectez tous les cordons d’alimentation de l’arrière de l’appareil ou du module d’alimentation de bureau (s’il est amovible) ou encore de la prise secteur.
Protection du cordon d’alimentation • Acheminer les cordons d’alimentation de
manière à ce que personne ne risque de marcher dessus et à ce qu’ils ne soient pas écrasés ou pincés par des objets.
Réparation-maintenance • Faire exécuter toutes les interventions de réparation-
maintenance par un technicien qualifi é. Aucun des éléments internes ne peut être réparé par l’utilisateur. Afi n d’éviter tout danger d’électrocution, l’utilisateur ne doit pas essayer de procéder lui-même à ces opérations car l’ouverture ou le retrait des couvercles risquent de l’exposer à de hautes tensions et autres dangers.
Fentes et orifi ces • Si le boîtier de l’appareil comporte des fentes ou des orifi ces, ceux-ci
servent à empêcher les composants internes sensibles de surchauffer. Ces ouvertures ne doivent jamais être bloquées par des objets.
Lithium Batterie • Il a danger d’explosion s’ll y a remplacment incorrect de la batterie.
Remplacer uniquement avec une batterie du meme type ou d’un ype equivalent recommande par le constructeur. Mettre au reut les batteries usagees conformement aux instructions du fabricant.
Vorsicht
Stromquellen • Dieses Gerät sollte nur über die auf dem Produkt angegebene
Stromquelle betrieben werden. Dieses Gerät wurde für eine Verwendung mit einer Hauptstromleitung mit einem geerdeten (neutralen) Leiter konzipiert. Der dritte Kontakt ist für einen Erdanschluß, und stellt eine Sicherheitsfunktion dar. Diese sollte nicht umgangen oder außer Betrieb gesetzt werden.
Stromunterbrechung • Um das Gerät auf sichere Weise vom Netz zu trennen, sollten
Sie alle Netzkabel aus der Rückseite des Gerätes, aus der externen Stomversorgung (falls dies möglich ist) oder aus der Wandsteckdose ziehen.
Schutz des Netzkabels • Netzkabel sollten stets so verlegt werden, daß sie nicht im
Weg liegen und niemand darauf treten kann oder Objekte darauf- oder unmittelbar dagegengestellt werden können.
Wartung • Alle Wartungsmaßnahmen sollten nur von qualifi ziertem Servicepersonal
durchgeführt werden. Die internen Komponenten des Gerätes sind wartungsfrei. Zur Vermeidung eines elektrischen Schocks versuchen Sie in keinem Fall, dieses Gerät selbst öffnen, da beim Entfernen der Abdeckungen die Gefahr eines elektrischen Schlags und/oder andere Gefahren bestehen.
Schlitze und Öffnungen • Wenn das Gerät Schlitze oder Löcher im Gehäuse aufweist,
dienen diese zur Vermeidung einer Überhitzung der empfi ndlichen Teile im Inneren. Diese Öffnungen dürfen niemals von anderen Objekten blockiert werden.
Litium-Batterie • Explosionsgefahr, falls die Batterie nicht richtig ersetzt
wird. Ersetzen Sie verbrauchte Batterien nur durch den gleichen oder einen vergleichbaren Batterietyp, der auch vom Hersteller empfohlen wird. Entsorgen Sie verbrauchte Batterien bitte gemäß den Herstelleranweisungen.
Advertencia
Alimentación eléctrica • Este equipo debe conectarse únicamente a la fuente/tipo
de alimentación eléctrica indicada en el mismo. La alimentación eléctrica de este equipo debe provenir de un sistema de distribución general con conductor neutro a tierra. La tercera pata (puesta a tierra) es una medida de seguridad, no puentearia ni eliminaria.
Desconexión de alimentación eléctrica • Para desconectar con seguridad la acometida
de alimentación eléctrica al equipo, desenchufar todos los cables de alimentación en el panel trasero del equipo, o desenchufar el módulo de alimentación (si fuera independiente), o desenchufar el cable del receptáculo de la pared.
Protección del cables de alimentación • Los cables de alimentación eléctrica se deben
instalar en lugares donde no sean pisados ni apretados por objetos que se puedan apoyar sobre ellos.
Reparaciones/mantenimiento • Solicitar siempre los servicios técnicos de personal
califi cado. En el interior no hay partes a las que el usuario deba acceder. Para evitar riesgo de electrocución, no intentar personalmente la reparación/mantenimiento de este equipo, ya que al abrir o extraer las tapas puede quedar expuesto a voltajes peligrosos u otros riesgos.
Ranuras y aberturas • Si el equipo posee ranuras o orifi cios en su caja/alojamiento,
es para evitar el sobrecalientamiento de componentes internos sensibles. Estas aberturas nunca se deben obstruir con otros objetos.
Batería de litio • Existe riesgo de explosión si esta batería se coloca en la posición
incorrecta. Cambiar esta batería únicamente con el mismo tipo (o su equivalente) recomendado por el fabricante. Desachar las baterías usadas siguiendo las instrucciones del fabricante.
FCC Class A Notice
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.
Note: This unit was tested with shielded cables on the peripheral devices. Shielded cables must be used with the unit to ensure compliance.
Extron’s Warranty
Extron Electronics warrants this product against defects in materials and workmanship for a period of three years from the date of purchase. In the event of malfunction during the warranty period attributable directly to faulty workmanship and/or materials, Extron Electronics will, at its option, repair or replace said products or components, to whatever extent it shall deem necessary to restore said product to proper operating condition, provided that it is returned within the warranty period, with proof of purchase and description of malfunction to:
USA, Canada, South America, Europe, Africa, and the Middle East: and Central America: Extron Electronics, Europe
Extron Electronics Beeldschermweg 6C
1001 East Ball Road 3821 AH Amersfoort
Anaheim, CA 92805, USA The Netherlands
Asia: Japan:
Extron Electronics, Asia Extron Electronics, Japan 135 Joo Seng Road, #04-01 Kyodo Building PM Industrial Bldg. 16 Ichibancho Singapore 368363 Chiyoda-ku, Tokyo 102-0082 Japan
This Limited Warranty does not apply if the fault has been caused by misuse, improper handling care, electrical or mechanical abuse, abnormal operating conditions or non­Extron authorized modifi cation to the product.
If it has been determined that the product is defective, please call Extron and ask for an Applications Engineer at (714) 491-1500 (USA), 31.33.453.4040 (Europe), 65.6383.4400 (Asia), or 81.3.3511.7655 (Japan) to receive an RA# (Return Authorization number). This will begin the repair process as quickly as possible.
Units must be returned insured, with shipping charges prepaid. If not insured, you assume the risk of loss or damage during shipment. Returned units must include the serial number and a description of the problem, as well as the name of the person to contact in case there are any questions.
Extron Electronics makes no further warranties either expressed or implied with respect to the product and its quality, performance, merchantability, or fi tness for any particular use. In no event will Extron Electronics be liable for direct, indirect, or consequential damages resulting from any defect in this product even if Extron Electronics has been advised of such damage.
Please note that laws vary from state to state and country to country, and that some provisions of this warranty may not apply to you.
Page 3
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201 Fax 07131 911203
ce-info@camboard.de
安全须知 中文
这个符号提示用户该设备用户手册中 有重要的操作和维护说明。
这个符号警告用户该设备机壳内有暴
露的危险电压,有触电危险。
注意
阅读说明书 用 户使 用该 设备 前必 须阅 读并 理
解 所有 安全 和使 用说 明。
保存说明书 • 用户应保存安全说明书以备将来使
用。
遵守警告 • 用户应遵守产品和用户指南上的所有安
全和操作说明。
避免追加 • 不要使用该产品厂商没有推荐的工具或
追加设备,以避免危险。
警告
电源 该 设备 只能 使用 产品 上标 明的 电源 。 设备
必 须使 用有 地线 的供 电系 统供 电。 第 三条 线 ( 地线 )是 安全 设施 ,不 能不 用或 跳过 。
拔掉电源 • 为安全地从设备拔掉电源,请拔掉所有设备后
或桌面电源的电源线,或任何接到市电系统的电源线。
电源线保护 妥善布线, 避免被踩踏,或重物挤压。 维护 所有维修必须由认证的维修人员进行。 设备内部没
有用户可以更换的零件。为避免出现触电危险不要自己 试图打开设备盖子维修该设备。
通风孔 • 有些设备机壳上有通风槽或孔,它们是用来防止
机内敏感元件过热。 不要用任何东西挡住通风孔。
锂电池 • 不正确的更换电池会有爆炸的危险。 必须使用与
厂家推荐的相同或相近型号的电池。 按照生产厂的建 议处理废弃电池。
Page 4
Precautions, continued
QuarterRackVersaToolsShelf
(2) 4-40 x 3/16" Screws
Use 2 mounting holes on opposite corners.
VersaTools Rack Shelf
1/4 Rack Width Front False Faceplate
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201 Fax 07131 911203
ce-info@camboard.de
Quick Start Guide — CVEQ 100 & SVEQ 100
C
To install and set up a CVEQ 100 and SVEQ 100, follow these steps:
Installation and service must be performed by authorized
personnel only.
Step 1
Turn the input and output devices off and unplug their power cords.
Step 2
Mount the CVEQ 100 or SVEQ 100 on a rack shelf, under a desktop, through a desktop (CVEQ 100 only), or on the back of a rack (SVEQ 100 only). The example illustration below shows a VersaTools® rack shelf; you can also use the standard or 6-inch deep Universal 19-inch rack shelves. See chapter 2, "Installation and Operation", for detailed descriptions of the different mounting options.
Rack Shelf Mounting
Step 3
Attach output cables to the rear panel of the line driver and to the output devices. See "Rear Panel Features and Cabling" in chapter 2.
Step 4
Attach input cables from the input devices and to the line driver’s rear panel input connectors. See "Rear Panel Features and Cabling" in chapter 2.
CVEQ 100 & SVEQ 100 • Quick Start Guide
QS-1
Page 5
Quick Start Guide — CVEQ & SVEQ, cont’d
CVEQ 100
GAIN
EQ
SVEQ 100
GAIN
EQ
GAIN
Y
C
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201 Fax 07131 911203
ce-info@camboard.de
Table of Contents
Step 5
Connect power cords and turn on the output devices (projector/ monitor, speakers), and input devices.
Step 6
The picture should appear, and sound should be audible. If not, ensure that all devices are plugged in and receiving power. Check the cabling; make adjustments as needed.
Step 7
While watching the display, adjust the video gain and equalization by using the rotary Gain and Equalize (EQ) controls. An oscilloscope can be used to achieve a more precise adjustment. See “Front Panel Features and Operation” in chapter 2.
Step 8
Adjust the potentiometers for the outputs, using an Extron Tweeker.
If using very short output cables, set all pots to the default setting (the arrow on the pot pointing to the dot beside it; see the illustrations below).
If using long cables, follow these steps:
a. Supply the Color Bars test signal to the input.
(Recommendation: Use an Extron VTG 300 Video Test Generator to generate the test signal.)
b. Adjust the Gain pot(s) for the output until the signal level at the
far end is the same as the input (or the display shows the correct brightness and contrast).
c. Adjust the EQ pot for the output so that no overshoot or round
front corner appears at the far end on the scope (or you see a sharp picture with no smearing).
Chapter One • Introduction .............................................1-1
About this Manual .................................................................... 1-2
About the CVEQ 100 and SVEQ 100 .................................... 1-2
Models .................................................................................... 1-2
Features .................................................................................. 1-2
Connection diagram example ............................................... 1-3
Chapter Two • Installation and Operation ................... 2-1
Mounting the CVEQ 100 and SVEQ 100 ............................. 2-2
Tabletop use ........................................................................... 2-2
UL rack mounting requirements ........................................... 2-2
Rack mounting ....................................................................... 2-3
Furniture mounting — under-desk ....................................... 2-5
Furniture mounting — through-desk (CVEQ 100 only) ....... 2-6
Back of the rack mounting (SVEQ 100 only) ........................ 2-7
Rear Panel Features and Cabling .......................................... 2-9
Power supply wiring ............................................................ 2-10
Front Panel Features and Operation ................................. 2-12
Gain adjustment control ......................................................
Equalization (EQ)
adjustment control ................................ 2-13
2-13
Appendix A • Specifications, Part Numbers, and Accessories
Specifications ..............................................................................A-2
Included Parts .............................................................................A-5
CVEQ 100/SVEQ 100 Mounting Accessories ...................... A-5
Cables and Adapters .................................................................A-5
........................................................................................A-1
All trademarks mentioned in this manual are the properties of their respective owners.
CVEQ 100 & SVEQ 100 • Quick Start Guide
CVEQ 100 & SVEQ 100 • Table of Contents
QS-2 TOC-i
68-1252-01 Rev. B
01 07
Page 6
Table of Contents, cont’d
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201 Fax 07131 911203
ce-info@camboard.de
CVEQ 100 and SVEQ 100
Chapter One
1
TOC-ii
CVEQ 100 & SVEQ 100 • Table of Contents
Introduction
About this Manual
About the CVEQ 100 and SVEQ 100
Page 7
CVEQ 100 & SVEQ 100 • Introduction
Introduction
CVEQ 100 & SVEQ 100 • Introduction
1-2
1-3
DVD
Projector
Extron SVEQ 100
S-Video Line Driver
12
V
0.2A
M
AX
L
R
L
R
Y
C
INPUT
OUTPUT
1,000’
Extron MPA 122
Mini Power Amplifier
Extron SI 26
Surface-mount Speakers
B
ASS
LEVEL
TREBLE
MINI PO
WER AMPLIFIE
R
MP
A 122
ON
OFF
LIMI
TER
STEREO
DU
AL
MONO
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201 Fax 07131 911203
ce-info@camboard.de
About this Manual
This manual provides information on the Extron VersaTools® CVEQ 100 and SVEQ 100 video line drivers and discusses how to install and operate them.
About the CVEQ 100 and SVEQ 100
The Extron CVEQ 100 and SVEQ 100 are high performance one-input, one-output video line drivers with unbalanced audio input and balanced/unbalanced audio output. Both models are ideal for driving video signals over extended cable runs up to 1000' (300 m) using Extron MHR cable.
In this manual “CVEQ” or “CVEQ 100”, or "SVEQ" or "SVEQ 100", or “line driver” are used to refer to the different models.
Models
CVEQ 100 — One input, one output composite video with
equalization and gain controls for the output
SVEQ 100 — One input, one output S-video with equalization
and separate Y/C gain controls for the output
Features
Stereo audio — Unbalanced stereo audio input can be output as
balanced or unbalanced stereo audio.
Gain adjustment — All models offer video gain adjustment.
The CVEQ 100 has a gain adjustment range of -1 dB to +3 dB. The SVEQ 100 has a gain adjustment range for Y of S-video from -1 dB to +3 dB, and for C of S-video from 0 dB to +10 dB.
Equalization adjustment — Each model also features an
equalization adjustment range from 0 dB to +7 dB @ 5 MHz that changes the level and peaking of the video output signal to compensate for use of long cables.
Rack and furniture mountability — Appropriate models can be
mounted on a rack shelf, under a desk, or in a podium.
Connection diagram example
The following diagram is an example of how the various supported devices can be connected to the SVEQ 100.
Example of devices connected to an SVEQ 100
Page 8
Introduction, cont’d
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201 Fax 07131 911203
ce-info@camboard.de
CVEQ 100 and SVEQ 100
Chapter Two
2
1-4
CVEQ 100 & SVEQ 100 • Introduction
Installation and Operation
Mounting the CVEQ 100 and SVEQ 100
Rear Panel Features and Cabling
Front Panel Features and Operation
Page 9
CVEQ 100 & SVEQ 100 • Installation and Operation
Installation and Operation
CVEQ 100 & SVEQ 100 • Installation and Operation
2-2
2-3
QuarterRackVersaToolsShelf
(2) 4-40 x 3/16" Screws
Use 2 mounting holes on opposite corners.
VersaTools Rack Shelf
1/4 Rack Width Front False Faceplate
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201 Fax 07131 911203
ce-info@camboard.de
Mounting the CVEQ 100 and SVEQ 100
Tabletop use
UL rack mounting requirements
The CVEQ 100 composite video line driver and the SVEQ 100 S-video line driver can be set on a table; mounted on a rack shelf; mounted under a desk or table; mounted through furniture (CVEQ 100 only); or mounted on the back of a rack (SVEQ 100 only).
Four self-adhesive rubber feet are included with the line driver.
For tabletop use, attach one foot at each corner of the bottom side of the unit and place the unit in the desired location.
The following Underwriters Laboratories (UL) requirements pertain to the safe installation of the line drivers in a rack.
1.
Elevated operating ambient temperature — If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient temperature. Therefore, install the line driver in an environment compatible with the maximum ambient temperature (Tma = +113 °F, +45 °C) specified by Extron.
2.
Reduced air flow — Install the equipment in a rack so that the amount of air flow required for safe operation of the equipment is not compromised.
3.
Mechanical loading — Mount the equipment in the rack so that a hazardous condition is not achieved due to uneven mechanical loading.
4.
Circuit overloading — Connect the equipment to the supply circuit and consider the effect that circuit overloading might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
5.
Reliable earthing (grounding) — Maintain reliable grounding of rack-mounted equipment. Pay particular attention to supply connections other than direct connections to the branch circuit (e.g. use of power strips).
Rack mounting
For rack mounting, do not install the rubber feet. Mount the distribution amplifier on a 19" wide 1U VersaTools® rack shelf (Extron RSF 123, part #60-190-20; Extron RSB, part #60-604-20), a standard 1U Universal or Basic rack shelf (Extron RSU 129, part #60-190-01; Extron RSB 129, part #60-604-01), or a Universal or Basic 1U 6-inch Deep Rack Shelf (Extron RSU 126, part #60-190-10; Extron RSB 126, part #60-604-10).
1.
If feet were previously installed on the bottom of the line driver, remove them.
2.
Mount the line driver on the rack shelf, using two 4-40 x 3/16" screws in opposite (diagonal) corners to secure the unit to the shelf.
3.
Install blank panel(s) or other unit(s) on the rack shelf.
Mounting the line driver on a VersaTools rack shelf
Page 10
CVEQ 100 & SVEQ 100 • Installation and Operation
Installation and Operation, cont’d
2-4
CVEQ 100 & SVEQ 100 • Installation and Operation
2-5
QuarterRackUnderdeskMounting
Under-desk mounting kit part # 70-212-01
Under-desk mounting kit part # 70-077-01
Use 2 mounting holes on opposite corners.
(2) 4-40 x 3/16" Screws
1U Universal Rack Shelf
Both front false faceplates use 2 screws.
QuarterRackStandardShelf
1/4 Rack Width Front False Faceplate
1/2 Rack Width Front False Faceplate
6" Deep Rack Shelf
Front false faceplate uses 2 screws.
1/2 Rack Width Front False Faceplate
Use 2 mounting holes on opposite corners.
(2) 4-40 x 3/16" Screws
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201 Fax 07131 911203
ce-info@camboard.de
Furniture mounting — under-desk
To mount the line driver under furniture, use the optional VersaTools® under-desk mounting kit for the SVEQ 100 (Extron MBU 123, part #70-212-01) or the optional under-desk kit for the CVEQ 100 (Extron MBU 125, part #70-077-01).
Preparing the line driver for under-desk mounting
Mounting the line driver on a standard rack shelf
Mounting the line driver on a 6-inch rack shelf
1. If rubber feet were previously attached to the bottom of the unit, remove them.
2.
Attach the mounting brackets to the line driver with the provided machine screws as shown in the previous figure.
3.
Hold the unit with the attached brackets against the underside of the table or other furniture. On the mounting surface, mark the location of the bracket’s screw holes.
4.
Drill 3/32" (2 mm) diameter pilot holes, 1/4" (6.3 mm) deep in the mounting surface at the marked screw locations.
5.
Insert #8 wood screws into the four pilot holes. Tighten each screw into the mounting surface until slightly less than 1/4" of the screw head protrudes.
6.
Align the mounting screws with the slots in the brackets and place the unit against the surface, with the screws through the bracket slots.
7.
Slide the unit slightly forward or back, then tighten all four screws to secure it in place.
Page 11
CVEQ 100 & SVEQ 100 • Installation and Operation
Installation and Operation, cont’d
2-6
CVEQ 100 & SVEQ 100 • Installation and Operation
2-7
BackofRackMountingEars
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201 Fax 07131 911203
ce-info@camboard.de
Furniture mounting — through-desk (CVEQ 100 only)
To mount the CVEQ 100 through furniture, use the optional VersaTools® through-desk mounting kit (Extron MBD 129, part #70-077-02), as follows.
Preparing the CVEQ 100 for through-desk mounting
Back of the rack mounting (SVEQ 100 only)
The SVEQ 100 can be mounted to the rear of a rack using the Extron VersaTools MBB 100 back of the rack mounting kit (part #70-367-01). The kit allows the product to be vertically mounted to the front or rear rack supports and facing either towards the front or the rear of the rack.
Using the MBB 100 back of the rack kit
1. If rubber feet were previously attached to the bottom of the unit, remove them.
2.
Attach the mounting brackets to the CVEQ 100 with the provided machine screws as shown in the previous figure.
3.
Hold the unit with the attached brackets against the underside of the table or other furniture. On the mounting surface, mark the location of the bracket’s screw holes.
4.
Drill 3/32" (2 mm) diameter pilot holes, 1/4" (6.3 mm) deep in the mounting surface at the marked screw locations.
5.
Insert #8 wood screws into the four pilot holes. Tighten each screw into the mounting surface until slightly less than 1/4" of the screw head protrudes.
6.
Align the mounting screws with the slots in the brackets and place the unit against the surface, with the screws through the bracket slots.
7.
Slide the unit slightly forward or back, then tighten all four screws to secure it in place.
1. If necessary, remove the feet from the bottom of the line driver.
2.
Remove two screws from one side of the unit. Retain the screws for possible later reassembly without the bracket.
Attach one bracket to the side of the unit using the longer
3.
screws included in the kit.
4.
Repeat steps 2 and 3 on the other side of the unit.
5.
Mount the unit to the rack using the two included rack screws (see the following illustration). The SVEQ 100 can be vertically mounted facing in either direction.
N
Only VersaTools products and most IP Link products
can be mounted using the back of the rack mounting kit.
Page 12
CVEQ 100 & SVEQ 100 • Installation and Operation
Installation and Operation, cont’d
2-8
CVEQ 100 & SVEQ 100 • Installation and Operation
2-9
L R
INPUT
OUTPUT
12V
0.2A MAX
L
VIDEO
R
VIDEO
1
4a 5
2a
3
12V
0.2A MAX
L
R
L R
Y
C
Y
C
INPUT OUTPUT
1
53 4b
2b
Outside
Inside
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201 Fax 07131 911203
ce-info@camboard.de
Rear Panel Features and Cabling
The following figures show the back panel configurations of the CVEQ 100 and SVEQ 100 line drivers.
CVEQ 100 rear panel
SVEQ 100 back of the rack installation example
SVEQ 100 rear panel
Power connector — Plug the external 12 VDC power supply
a
into this 2-pin, 3.5 mm captive screw connector. The power supply is included with the unit. The "Power supply wiring" section in this chapter explains how to wire the connector.
Video input connector (CVEQ) — Connect a composite video
Ç
input source to this BNC connector.
S-video input connectors (SVEQ) — Connect an S-video input
É
source to these BNC connectors.
Audio input connectors — Connect an unbalanced stereo audio
c
source to these left (L) and right (R) RCA connectors. Wire the male connector as shown in the following illustration.
Page 13
CVEQ 100 & SVEQ 100 • Installation and Operation
Installation and Operation, cont’d
2-10
CVEQ 100 & SVEQ 100 • Installation and Operation
2-11
Tip
(Signal)
Sleeve (Gnd)
Unbalanced Audio Output
Tip
NO GROUND HERE
Sleeve(s)
Tip
NO GROUND HERE
Balanced Audio Output
Tip
Ring
Sleeve(s)
Tip
Ring
L R
CAUTION Connect the sleeve to ground
(Gnd).
Connecting the sleeve to a negative (–) terminal will damage the audio output circuits.
L R
Power Supply
Output Cord
SECTION A–A
Ridges
Smooth
A A
Orange Captive Screw
Connector
Tie Wrap
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201 Fax 07131 911203
ce-info@camboard.de
To verify the polarity before connection, plug in the power supply with no load and check the output with a voltmeter.
W
The two power cord wires must be kept separate
while the power supply is plugged in. Remove power before wiring.
Video output connector (CVEQ) — Connect a composite video
Ü
output device to this BNC connector.
S-video output connector (SVEQ) — Connect an S-video output
á
device to these Y and C BNC connectors.
Audio output connector — Cable a balanced/unbalanced audio
e
output device to this 3.5 mm 5-pole captive screw connector. Wire the male connector as shown below.
Power supply wiring
Wire the line driver's power connector, as shown below.
C
The length of the exposed (stripped) copper wires
is important.
The ideal length is 5/16” (7 mm). Longer bare wires can short together. Shorter wires are not as secure in the direct insertion connectors and could be pulled out.
Use the supplied tie-wrap to strap the power cord to the extended tail of the connector.
N
Your line driver may have shipped with a blue captive
screw connector. This blue connector can be plugged into either a blue or an orange power receptacle.
The blue connector does not have the extended tail or the included tie-wrap.
N
Do not tin the power supply leads before installing in
the direct insertion connector. Tinned wires are not as secure in the connectors and could be pulled out.
Power connector wiring
C
Power supply voltage polarity is critical. Incorrect
voltage polarity can damage the power supply and the line driver. Identify the power cord negative lead by the ridges on the side of the cord.
Page 14
CVEQ 100 & SVEQ 100 • Installation and Operation
Installation and Operation, cont’d
2-12
CVEQ 100 & SVEQ 100 • Installation and Operation
2-13
VIDEO LINE DRIVER
CVEQ 100
GAIN
EQ
1
2a 3
S-VIDEO LINE DRIVER
SVEQ 100
GAIN
EQ
GAIN
Y
C
1
2a 3 2b
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201 Fax 07131 911203
ce-info@camboard.de
Front Panel Features and Operation
The following figures show the front panel configurations of the CVEQ 100 and SVEQ 100.
CVEQ 100 front panel
SVEQ 100 front panel
Power LED — When lit, this LED indicates power is applied to
a
the line driver.
Gain potentiometer (CVEQ and luma of SVEQ) — Use an
Ç
Extron Tweeker (a small screwdriver) to rotate this pot to adjust the CVEQ 100's gain and the SVEQ 100's luminance gain when the line driver is connected to long output cables. The adjustment range is -1 dB to +3 dB. The default is unity (the dot position). See "Gain adjustment control" in this chapter.
Equalization (EQ) potentiometer — Use an Extron Tweeker
c
to rotate this pot to adjust equalization when the line driver is connected to long output cables. The adjustment range is 0 dB to +7 dB. The default is set to 0 dB (the dot position). See "Equalization (EQ) adjustment control" in this chapter.
Gain adjustment control
The gain control adjusts picture brightness by compensating for signal amplitude loss caused by cable resistance. To adjust the output gain, view the display while using a small, flat-blade screwdriver to rotate this two-turn potentiometer. This control produces a gain adjustment ranging from -6 dB to + 6dB. Select the setting that gives the best picture brightness.
You can judge the adjustment visually by looking at the display. For a more precise setting you can use an oscilloscope or a waveform monitor connected to the far end of the output cable, and adjust the gain so that the level at the waveform monitor is 100 IRE.
Equalization (EQ) adjustment control
The equalization control adjusts the output level and peaking to get a sharp picture. This adjustment changes the level and peaking of the output signal to compensate for capacitance caused by up to 1000' (300 m) of Extron MHR cable.
Use a small, flat-blade screwdriver to rotate this control. View the display and select the setting that gives the sharpest picture. For a more precise setting you can use an oscilloscope or a waveform monitor connected to the far end of the output cable, and adjust the equalization so that the color burst ranges between -20 IRE and +20 IRE.
N
The EQ control is a potentiometer with a soft mechanical
stop at the high and the low end. If you have reached the high or low end of the adjustment, the potentiometer makes a clicking sound as you turn it, and no change is apparent on the display.
Gain potentiometer (Chroma of SVEQ)— Use an Extron
É
Tweeker to rotate this pot to adjust the chroma gain when the SVEQ 100 is connected to long output cables. The adjustment range is 0 dB to +10 dB. The default is unity (The dot position). See "Gain adjustment control" in this chapter.
Page 15
Installation and Operation, cont’d
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201 Fax 07131 911203
ce-info@camboard.de
CVEQ 100 and SVEQ 100
Appendix A
A
2-14
CVEQ 100 & SVEQ 100 • Installation and Operation
Specifications, Part Numbers,
and Accessories
Specifications
Included Parts
CVEQ100/SVEQ 100 Mounting Accessories
Cables and Adapters
Page 16
CVEQ 100 & SVEQ 100 • Specifications, Part #s, Accessories
Specifications, Part Numbers, and Accessories
CVEQ 100 & SVEQ 100 • Specifications, Part #s, Accessories
A-2
A-3
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201 Fax 07131 911203
ce-info@camboard.de
Specifications
Video
Gain ................................................. Composite video and Y of S-video: -1 dB
to +3 dB (x0.9 to x1.4), adjustable C of S-video: 0dB to +10 dB (x1 to x3), adjustable
Equalization ................................... 0 dB to +7 dB (x1 to x2) at 5 MHz,
adjustable
Bandwidth (Y of S-video) ............. 185 MHz (-3 dB)
Output cable driving distance ..... Up to 1000' (300 m) with Extron MHR
cable
Video input
Number/signal type
CVEQ 100 ........................... 1 composite video
SVEQ 100 ............................ 1 S-video
Connectors
CVEQ 100 ........................... 1 female BNC
SVEQ 100 ............................ 2 female BNC
Nominal level ................................ 1 Vp-p for Y of S-video, and for composite
video (including sync)
0.3 Vp-p for C of S-video
Minimum/maximum levels
CVEQ 100 ........................... 0.4 to 2.0 Vp-p with no offset at unity gain
SVEQ 100 ............................ For Y: 0.4 to 2.0 Vp-p with no offset at
unity gain
Impedance ..................................... 75 ohms
Return loss ..................................... <-25 dB @ 0 to 5 MHz
DC offset (max. allowable)........... 4.0 V
Input coupling ............................... AC
Video output
Number/signal type
CVEQ 100 ........................... 1 composite video
SVEQ 100 ............................ 1 S-video
Connectors
CVEQ 100 ........................... 1 female BNC
SVEQ 100 ............................ 2 female BNC
Nominal level ................................ 1 Vp-p for Y of S-video, and for composite
video (including sync)
0.3 Vp-p for C of S-video
Minimum/maximum levels ........ 0.4 to 2.0 Vp-p (follows input)
Impedance ..................................... 75 ohms
Return loss ..................................... -30 dB @ 5 MHz
DC offset ........................................ ±5 mV with no input signal
Floating: +0.1 to -0.6 V, depending on input signal content
Sync
Standards ........................................ NTSC 3.58, NTSC 4.43, PAL, SECAM
Audio
Gain ................................................ Unbalanced output: 0 dB;
balanced output: +6 dB
Frequency response ..................... 20 Hz to 20 kHz, +0.05 dB, -0.0 dB
THD + Noise ................................. 0.015% @ 1 kHz at nominal level
S/N ................................................. >100 dB at maximum output (unweighted)
Stereo channel separation ........... >80 dB @ 1 kHz
Output cable driving distance ..... Up to 1000’ (300 m) with Extron STP cable
Audio input
Number/signal type .................... 1 stereo unbalanced
Connectors .................................... 2 RCA female
Impedance ..................................... 20k ohms unbalanced, DC coupled
Nominal level ................................ -10 dBV (316 mVrms)
Maximum level ............................. +16 dBu (4.9 V), balanced at
1% THD+N
N
0 dBu = 0.775 Vrms, 0 dBV = 1 Vrms, 0 dBV 2 dBu
Audio output
Number/signal type .................... 1 stereo, balanced/unbalanced
Connectors .................................... (1) 3.5 mm captive screw connector, 5 pole
Impedance ..................................... 50 ohms unbalanced, 100 ohms balanced
Nominal level ................................ -10 dBV (316 mVrms), unbalanced;
-2 dBu (632 mV), balanced output
Maximum level .............................. +9 dBV (2.8 V) unbalanced,
+17 dBu (5.6 V) balanced at 1% THD+N
with a 10k ohm load
Page 17
CVEQ 100 & SVEQ 100 • Specifications, Part #s, Accessories
Specifications, Part Numbers, Accessories, cont’d
CVEQ 100 & SVEQ 100 • Specifications, Part #s, Accessories
A-4
A-5
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201 Fax 07131 911203
ce-info@camboard.de
General
External power supply ................. 100 VAC to 240 VAC, 50/60 Hz, external,
autoswitchable; to 12 VDC, 1 A, regulated
Power input requirements ........... 12 VDC, 0.2 A
Temperature/humidity ................ Storage: -40 to +158 °F (-40 to +70 °C) /
10% to 90%, noncondensing ..
Operating: +32 to +122 °F (0 to +50 °C) /
10% to 90%, noncondensing
Rack mount .................................... Yes, with optional 1U rack shelf, part
#60-190-01 or 60-604-01; or 1U, 6" deep
rack shelf, part #60-190-10 or 60-604-10; or
VersaTools® 3" deep rack shelf, part
#60-190-20 or 60-604-20
Also furniture and projector mountable
with optional mounting kits.
Enclosure type .............................. Metal
Enclosure dimensions
CVEQ 100 .......................... 1.0" H x 4.3" W x 3.0" D
(<1U high, quarter rack wide)
2.5 cm H x 11.0 cm W x 7.6 cm D
(Depth excludes connectors. )
SVEQ 100 ............................ 1.7" H x 4.3" W x 3.0" D
(1U high, quarter rack wide)
4.3 cm H x 11.0 cm W x 7.6 cm D
(Depth excludes connectors.)
Product weight .............................. 0.7 lbs (0.3 kg)
Shipping weight ........................... 3 lbs (2 kg)
Vibration ........................................ ISTA 1A in carton (International Safe
Transit Association)
Listings............................................ UL, CUL
Compliances ................................... CE, FCC Class A, VCCI, AS/NZS, ICES
MTBF ............................................... 30,000 hours
Warranty ........................................ 3 years parts and labor
N
N
All nominal levels are at ±10%.
Specifications are subject to change without notice.
Included Parts
Included parts Replacement
part number
CVEQ 100 or 60-812-01
SVEQ 100 60-813-01
CVEQ 100 & SVEQ 100 User's manual
Tweeker
Rubber feet (not attached)
CVEQ 100/SVEQ 100 Mounting Accessories
Description Part number
RSF 123 VersaTools® rack shelf kit 60-190-20
RSB 123 VersaTools rack shelf 60-604-20
RSU 126 6" deep universal rack shelf kit 60-190-10
RSB 126 6" deep basic rack shelf 60-604-10
RSU 129 1U universal rack shelf kit 60-190-01
RSB 129 1U basic rack shelf 60-604-01
MBU 123 under-desk mount kit 70-212-01
MBU 125 under-desk mount kit 70-077-01
MBD 125 through-desk mount kit 70-077-02
MBB 100 back of the rack mount kit 70-367-01
Cables and Adapters
Description Part number
MHR-2P Plenum S-video cable 22-129-0X
MHR-2 Non-Plenum S-video cable 22-123-0X
SVHSF-BNCM adapter (S-video female to 2 male BNCs)
RCAF-BNCM/10 adapter (RCA female to BNC male, Qty. 10)
AV RCA/6 cable (RCA male to male 6') IN8906
26-541-0X
100-229-01
Page 18
CVEQ 100 & SVEQ 100 • Specifications, Part #s, Accessories
Specifications, Part Numbers, Accessories, cont’d
CVEQ 100 & SVEQ 100 • Specifications, Part #s, Accessories
A-6
A-7
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201 Fax 07131 911203
ce-info@camboard.de
Page 19
Specifications, Part Numbers, Accessories, cont’d
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201 Fax 07131 911203
ce-info@camboard.de
A-8
CVEQ 100 & SVEQ 100 • Specifications, Part #s, Accessories
Loading...