WARNING: This symbol, , when used on the product, is intended to
alert the user of the presence of uninsulated dangerous voltage within the
product’s enclosure that may present a risk of electric shock.
ATTENTION: This symbol, , when used on the product, is intended
to alert the user of important operating and maintenance (servicing)
instructions in the literature provided with the equipment.
For information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the Extron Safety and
Regulatory Compliance Guide, part number 68-290-01, on the Extron website,
www.extron.com.
Instructions de sécurité • Français
AVERTISSEMENT : Ce pictogramme, , lorsqu’il est utilisé sur le
produit, signale à l’utilisateur la présence à l’intérieur du boîtier du produit
d’une tension électrique dangereuse susceptible de provoquer un choc
électrique.
ATTENTION : Ce pictogramme, , lorsqu’il est utilisé sur le produit,
signale à l’utilisateur des instructions d’utilisation ou de maintenance
importantes qui se trouvent dans la documentation fournie avec le
matériel.
Pour en savoir plus sur les règles de sécurité, la conformité à la réglementation,
la compatibilité EMI/EMF, l’accessibilité, et autres sujets connexes, lisez les
informations de sécurité et de conformité Extron, réf. 68-290-01, sur le site
Extron, www.extron.com.
Sicherheitsanweisungen • Deutsch
WARNUNG: Dieses Symbol auf dem Produkt soll den Benutzer
darauf aufmerksam machen, dass im Inneren des Gehäuses dieses
Produktes gefährliche Spannungen herrschen, die nicht isoliert sind
und die einen elektrischen Schlag verursachen können.
Инструкция по технике безопасности • Русский
ПРЕДУПРЕЖДЕНИЕ: Данный символ, , если указан
на продукте, предупреждает пользователя о наличии
неизолированного опасного напряжения внутри корпуса
продукта, которое может привести к поражению
электрическим током.
ВНИМАНИЕ: Данный символ, , если указан на продукте,
предупреждает пользователя о наличии важных инструкций
по эксплуатации и обслуживанию в руководстве,
прилагаемом к данному оборудованию.
Для получения информации о правилах техники безопасности,
соблюдении нормативных требований, электромагнитной
совместимости (ЭМП/ЭДС), возможности доступа и других
вопросах см. руководство по безопасности и соблюдению
нормативных требований Extron на сайте Extron: www.extron.com,
номер по каталогу - 68-290-01.
VORSICHT: Dieses Symbol auf dem Produkt soll dem Benutzer in der
im Lieferumfang enthaltenen Dokumentation besonders wichtige Hinweise
zur Bedienung und Wartung (Instandhaltung) geben.
Weitere Informationen über die Sicherheitsrichtlinien, Produkthandhabung,
EMI/EMF-Kompatibilität, Zugänglichkeit und verwandte Themen finden Sie in
den Extron-Richtlinien für Sicherheit und Handhabung (Artikelnummer
68-290-01) auf der Extron-Website, www.extron.com.
Instrucciones de seguridad • Español
ADVERTENCIA: Este símbolo, , cuando se utiliza en el producto,
avisa al usuario de la presencia de voltaje peligroso sin aislar dentro del
producto, lo que puede representar un riesgo de descarga eléctrica.
ATENCIÓN: Este símbolo, , cuando se utiliza en el producto, avisa
al usuario de la presencia de importantes instrucciones de uso y
mantenimiento recogidas en la documentación proporcionada con el
equipo.
Para obtener información sobre directrices de seguridad, cumplimiento
de normativas, compatibilidad electromagnética, accesibilidad y temas
relacionados, consulte la Guía de cumplimiento de normativas y seguridad de
Extron, referencia 68-290-01, en el sitio Web de Extron, www.extron.com.
안전 가이드라인, 규제 준수, EMI/EMF 호환성, 접근성, 그리고 관련 항목에
대한 자세한 내용은 Extron 웹 사이트(www.extron.com)의 Extron 안전 및
규제 준수 안내서, 68-290-01 조항을 참조하십시오.
FCC Class A Notice
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part15 of the FCC rules. The ClassA limits provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause interference. This interference must be corrected at
the expense of the user.
NOTE: For more information on safety guidelines, regulatory compliances, EMI/EMF compatibility,
accessibility, and related topics, see the “Extron Safety and Regulatory Compliance
Installing the CS 123T System — Single Installer 5
Installing the CS 120P in a Suspended Ceiling —
Division of Labor .............................................. 18
Installing the CS 3T in a Suspended Ceiling —
Division of Labor .............................................. 23
Installing the CS 120P in a Hard Ceiling ............ 30
Painting the Baffle and Grille ............................. 30
CS 3T and CS 120P User Guide • Contentsv
Introduction
This section gives an overview of the Extron CS 123T SpeedMount Ceiling Speaker System,
consisting of the CS 3T speakers and CS 120P enclosure. It also provides a list of system
features and an application diagram. Topics include:
• About this Guide
• Overview
• Features
• Application Example
About this Guide
This guide describes the Extron CS 123T Speaker System, the CS 3T speaker pair and the
CS 120P enclosure and provides instructions for installing all components of the system in
different types of ceilings.
Overview
The CS 123T system features a low profile design that houses a 3-inch driver contained in a
UL 2043 rated enclosure (CS 120P) designed for use in plenum rated ceiling spaces.
This unique speaker system splits installation into two phases, rough-in and finish, allowing
the installer to “reserve” space for the speaker system by installing the CS 120P back can
and then later installing the CS 3T speaker. This two-step process (division of labor) is
especially useful when multiple installers are involved. The CS 120P can be installed by the
low voltage contractor while the CS 3T can be installed by the AV systems contractor.
CS 3T and CS 120P User Guide • Introduction1
Features
• Patented two-piece speaker system for suspended ceilings in division-of-labor
installations —
• CS 120P plenum ceiling tile enclosure, 1’ x 2’ (30.5 cm x 61 cm), pair
• CS 3T full-range speaker cartridge, pair
• Components available separately or together in a CS 123T complete assembly
• Enclosure and speaker cartridge can be installed separately by low-voltage
and AV system contractors
• Provides significant time and cost savings in ceiling speaker installation
• 3” (7.6 cm) full-range driver
• 165° conical dispersion provides wide coverage and allows for flexible speaker
placement
• 8 ohm direct or 70/100 volt operation on a 6 position, behind-the-grille
selector —
• 8 ohm direct
• 70 volt: 16, 8, 4, 2, and 1 watt selectable
• 100 volt: 16, 8, 4, and 2 watt selectable
• 16 watts continuous pink noise, 32 watts continuous program
• Internal driver overload protection
• Thin bezel and magnetically attached grille
• Grille and bezel are available in white only and may be painted to match
environment
• Spring-loaded locking arms on the CS 3T for quick installation
• Fast-installing enclosure speeds installation; no tile bridge necessary
• UL 2043 plenum rated enclosure
• Low profile, 5” (12.7 cm) deep enclosure for plenum environments
• Compatible with US 2’ x 2’ ceiling grids and metric 600 mm x 600 mm ceiling
The illustration below is one example of configuring a system using the CS 123T.
Extron
CS 123T
SpeedMount Ceiling Speaker System
Extron
Laptop
Blu-ray Player
Extron
Extron
Extron
Extron
IN1608 MA
Scaling Presentation Switcher
1
100-240V ~ -- A MAX
2
50/60 Hz
IN1608 IPCP MA 70
3
CONFIGURABLE
HDMIHDMI
4
HDMIHDMI
5
6
INPUTSOUTPUTSAUDIO INPUTSOUTPUTSREMOTE
7
SIG
DTP IN
R
RS-232 IR
Tx Rx Tx RxG
LINKSIG
OVER DTP
RS-232 IR
Tx Rx Tx RxG
Extron
Extron
COM 1 COM 2 COM 3DIGITAL I/O
G
Tx RxGTx RxGTx Rx
IR/SERIALRELAYS
1
2
1 2 C 3 4 C
SG
SG
8
LINKSIG
OVER DTP
RS-232 IR
Tx Rx Tx RxG
DTP IN
12RTSCTS
+V+S-S G
PWR OUT = 6W
C
DTP OUT
Extron
Extron
Extron
Extron
Extron
Extron
Audio
LAN 1
34G
eBUS
LINK
LAN 2LAN 3
A
HDMI
B
L1RLR
L2
L4
R
3
R
L5R
L6
1
+48V
MIC/LINE
R
2
+48V
12
VARIABLE
LR
AMPLIFIED OUTPUT
70V -100W
CLASS 2 WIRING
RESET
RS-232
Tx Rx
G
STANDBY/ON
PQLSHDMIOPEN/CLOSEFL OFF
USB
Figure 1. Application Diagram of a CS 123T Installation
CS 3T and CS 120P User Guide • Installation3
Installation
This section provides instructions for installing the CS 3T speakers and the CS 120P
enclosure. Topics include:
• Installation Considerations
• Installation Configurations
• Installing the CS 123T — Single Installer
• Installing the CS 120P in a Suspended Ceiling — Division of Labor
• Installing the CS 3T in a Suspended Ceiling — Division of Labor
• Installing the CS 120P in a Hard Ceiling
• Painting the Baffle and Grille
Installation Considerations
WARNING: May result in serious injury. Installation and service must be performed
by authorized personnel only.
AVERTISSEMENT :Risque potentiel de blessure grave. L’installation et l’entretien
doivent être effectués par le personnel autorisé uniquement.
• All wiring and electrical connections must conform to all applicable building codes and
local ordinances.
• Installation in a plenum-rated environment requires plenum rated cable or conduit.
• If using secondary support cables, the installer provides the cables.
NOTE: Installation of conduit and conduit adapters must conform to all applicable
building codes and local ordinances.
Installation Configurations
The CS 3T can be configured in the following ways:
• Open-back: For configurations in which the CS 120P is not used, use the ceiling
mount kit accessory, available at www.extron.com. The C-ring spreads out the
clamping force of the dog-legs when used in drop ceilings and gypsum ceilings.
• Using the CS 120P: When used with the CS 120P, the CS 3T can be placed in plenum
environments. This is the only configuration that is UL 2043 rated.
NOTE: The CS 120P can be ordered separately or as part of the CS 123T kit.
For hard ceiling installations, see Installing the CS 120P in a Hard Ceiling on
page 30.
CS 3T and CS 120P User Guide • Installation4
Installing the CS 123T System — Single Installer
Side View
15/16" (24 mm)
If a single installer is installing the CS 123T system, follow this procedure for the entire
system:
NOTE: The ceiling grid must be installed before the installation of the CS 123T begins.
• Verify if fiberglass ceiling tiles are being used (see step 3 below and step 11 on
page 9 for details).
• The grid face must be at least 15/16 inch (24 mm) for proper installation of the
CS 120P (see step 13 on page 10 for details on suspending the enclosure on a
smaller grid face).
Grid Face
Figure 2. Grid Face Example
1. Disconnect power — Power down all attached devices before proceeding.
2. Verify the space where the system will be installed — Ensure that there is sufficient
clearance above the ceiling tile for the unit to be installed.
3. Cut a hole for the CS 3T speaker — Use the provided cutout template to outline the
hole to be cut in the ceiling tile as described below.
a. Remove the ceiling tile.
b. To find the center of the tile, use a tape measure to measure the space between
two opposite corners (diagonally), and mark the half-way point.
c. Position the center hole of the cutout template directly over the center of the tile
that you marked in step3b.
d. Using the provided cutout template, trace a circle on the ceiling tile as follows:
For installations in ceiling tiles that are NOT fiberglass or when installing
the speakers in an open back configuration: Trace a circle around the cutout
template.
NOTE: The fiberglass tile adapters are not needed and can be discarded.
For installations in 1-inch (2.54 cm) thick fiberglass ceiling tiles with the
CS 120P:
NOTE: A set of fiberglass tile adapters is provided with both the CS 3T and the
CS 120P. Only one set is needed to install the CS 3T with the CS 120P kit in
a 1-inch (2.54 cm) thick fiberglass tile. The adapter works only with 1-inch
(2.54 cm) thick fiberglass tile.
i. Place the fiberglass tile adapter around the outer diameter of the template that
ii. Trace a circle around the outer diameter of the adapter.
was positioned in step 3c.
CS 3T and CS 120P User Guide • Installation5
e. Cut out the circle traced in the ceiling tile.
V
V
f. Replace the tile in the ceiling.
4. Remove the adjacent ceiling tile — To facilitate the installation
process, remove the tile adjacent to the ceiling tile where the
CS 3T will be installed. If the CS 120P is being installed, skip to
step 6. Otherwise, proceed to step 5.
5. If NOT using the CS 120P, install the Ceiling Mount kit — Place two V-rails and
one C-ring across the tile above the hole that you cut in step 3 where the speaker will
be installed.
a. Place the two V-rails in parallel across the top of the ceiling tile so that the ends of
the V-rails rest securely over the ceiling grid with the hole that was cut in the tile
situated between the V-rails, as shown below.
NOTE: The V-rails must be placed with the rail screw holes facing (closest to)
the hole in the ceiling tile.
-rail
Figure 3. Install the V-rails
b. Install the C-ring clips over the V-rails screw holes so that the C-ring is centered
over the tile hole and supported by the V-rails, as shown below.
C-ring
-rail
Figure 4. Install the C-ring
c. Insert a screw (included) through the C-ring and into the V-rail screw hole as shown
above. Do this for each V-rail.Skip to step 14 on page 10.
d. Skip to step 14 on page 10.
CS 3T and CS 120P User Guide • Installation6
6. Configure the CS 120P for a U.S. or metric ceiling grid — For U.S. ceilings (2 feet
by 2 feet or 2 feet by 4 feet), leave intact the four tabs that are on one of the short ends
of the enclosure.
For metric ceilings (600 mm by 600 mm or 600 mm by 1200 mm), cut off the tabs.
Tabs (4)
Removable
Tabs
Figure 5. Tabs on the CS 120P
7. Remove the cover plate — Loosen (do not remove) the two screws on the cover
plate and remove it, as shown in figure 6.
Cover Plate
Figure 6. Removing the Cover Plate
8. Route the cables through the cover plate —
NOTES:
• The CS 120P is fully UL 2043 compliant only when it is used with a metal
conduit or with plenum rated cables.
• Installation of all conduits, conduit adapters, wiring, and electrical connections
must conform to all applicable building codes and local ordinances.
Using a flexible conduit:
a. Route wires through the conduit.
b. Insert the conduit into the cover plate opening using an appropriate conduit
adapter, and secure the conduit to the plate as shown below.
c. Pull the wires out of the conduit and through the cover plate.
CS 3T and CS 120P User Guide • Installation7