Extron electronics Cable Cubby 600, Cable Cubby 800, Cable Cubby 300C, Cable Cubby 300S, Cable Cubby 200 User Manual

Extron Electronics, USA
1230 South Lewis Street Anaheim, CA 92805 USA
714.491.1500 Fax 714.491.1517
Extron Electronics, Europe
Beeldschermweg 6C 3821 AH Amersfoort The Netherlands +31.33.453.4040 Fax +31.33.453.4050
Extron Electronics, Asia
135 Joo Seng Road, #04-01 PM Industrial Building Singapore 368363 +65.6383.4400 Fax +65.6383.4664
Extron Electronics, Japan
Kyodo Building 16 Ichibancho Chiyoda-ku, Tokyo 102-0082 Japan +81.3.3511.7655 Fax +81.3.3511.7656
www.extron.com
© 2006 Extron Electronics. All rights reserved.
User’s Manual
Surface Access Products for Cables, AAPs, and Power Outlets
68-701-01 Rev. G
10 06
Cable Cubby® 200
Cable Cubby
®
300C
Cable Cubby
®
300S
Cable Cubby
®
600
Cable Cubby
®
800
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201 Fax 07131 911203
ce-info@camboard.de
Precautions
This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment.
This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product’s enclosure that may present a risk of electric shock.
Caution
Read Instructions • Read and understand all safety and operating
instructions before using the equipment.
Retain Instructions • The safety instructions should be kept for future
reference.
Follow Warnings • Follow all warnings and instructions marked on the
equipment or in the user information.
Avoid Attachments • Do not use tools or attachments that are not
recommended by the equipment manufacturer because they may be hazardous.
Warning
Power sources • This equipment should be operated only from the power source
indicated on the product. This equipment is intended to be used with a main power system with a grounded (neutral) conductor. The third (grounding) pin is a safety feature, do not attempt to bypass or disable it.
Power disconnection • To remove power from the equipment safely, remove all power
cords from the rear of the equipment, or the desktop power module (if detachable), or from the power source receptacle (wall plug).
Power cord protection • Power cords should be routed so that they are not likely to be
stepped on or pinched by items placed upon or against them.
Servicing • Refer all servicing to qualifi ed service personnel. There are no user-
serviceable parts inside. To prevent the risk of shock, do not attempt to service this equipment yourself because opening or removing covers may expose you to dangerous voltage or other hazards.
Slots and openings • If the equipment has slots or holes in the enclosure, these are
provided to prevent overheating of sensitive components inside. These openings must never be blocked by other objects.
Lithium battery • There is a danger of explosion if battery is incorrectly
replaced. Replace it only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions.
Ce symbole sert à avertir l’utilisateur que la documentation fournie avec le matériel contient des instructions importantes concernant l’exploitation et la maintenance (réparation).
Ce symbole sert à avertir l’utilisateur de la présence dans le boîtier de l’appareil de tensions dangereuses non isolées posant des risques d’électrocution.
Attention
Lire les instructions• Prendre connaissance de toutes les consignes de
sécurité et d’exploitation avant d’utiliser le matériel.
Conserver les instructions• Ranger les consignes de sécurité afi n de pouvoir
les consulter à l’avenir.
Respecter les avertissements • Observer tous les avertissements et consignes
marqués sur le matériel ou présentés dans la documentation utilisateur.
Eviter les pièces de fi xation • Ne pas utiliser de pièces de fi xation ni d’outils
non recommandés par le fabricant du matériel car cela risquerait de poser certains dangers.
Avertissement
Alimentations• Ne faire fonctionner ce matériel qu’avec la source d’alimentation
indiquée sur l’appareil. Ce matériel doit être utilisé avec une alimentation principale comportant un fi l de terre (neutre). Le troisième contact (de mise à la terre) constitue un dispositif de sécurité : n’essayez pas de la contourner ni de la désactiver.
Déconnexion de l’alimentation• Pour mettre le matériel hors tension sans danger,
déconnectez tous les cordons d’alimentation de l’arrière de l’appareil ou du module d’alimentation de bureau (s’il est amovible) ou encore de la prise secteur.
Protection du cordon d’alimentation • Acheminer les cordons d’alimentation de
manière à ce que personne ne risque de marcher dessus et à ce qu’ils ne soient pas écrasés ou pincés par des objets.
Réparation-maintenance • Faire exécuter toutes les interventions de réparation-
maintenance par un technicien qualifi é. Aucun des éléments internes ne peut être réparé par l’utilisateur. Afi n d’éviter tout danger d’électrocution, l’utilisateur ne doit pas essayer de procéder lui-même à ces opérations car l’ouverture ou le retrait des couvercles risquent de l’exposer à de hautes tensions et autres dangers.
Fentes et orifi ces • Si le boîtier de l’appareil comporte des fentes ou des orifi ces, ceux-ci
servent à empêcher les composants internes sensibles de surchauffer. Ces ouvertures ne doivent jamais être bloquées par des objets.
Lithium Batterie • Il a danger d’explosion s’ll y a remplacment incorrect de la batterie.
Remplacer uniquement avec une batterie du meme type ou d’un ype equivalent recommande par le constructeur. Mettre au reut les batteries usagees conformement aux instructions du fabricant.
Safety Instructions • English
Consignes de Sécurité • Français
Sicherheitsanleitungen • Deutsch
Dieses Symbol soll dem Benutzer in der im Lieferumfang enthaltenen Dokumentation besonders wichtige Hinweise zur Bedienung und Wartung (Instandhaltung) geben.
Dieses Symbol soll den Benutzer darauf aufmerksam machen, daß im Inneren des Gehäuses dieses Produktes gefährliche Spannungen, die nicht isoliert sind und die einen elektrischen Schock verursachen können, herrschen.
Achtung
Lesen der Anleitungen • Bevor Sie das Gerät zum ersten Mal verwenden,
sollten Sie alle Sicherheits-und Bedienungsanleitungen genau durchlesen und verstehen.
Aufbewahren der Anleitungen • Die Hinweise zur elektrischen Sicherheit
des Produktes sollten Sie aufbewahren, damit Sie im Bedarfsfall darauf zurückgreifen können.
Befolgen der Warnhinweise • Befolgen Sie alle Warnhinweise und
Anleitungen auf dem Gerät oder in der Benutzerdokumentation.
Keine Zusatzgeräte • Verwenden Sie keine Werkzeuge oder Zusatzgeräte,
die nicht ausdrücklich vom Hersteller empfohlen wurden, da diese eine Gefahrenquelle darstellen können.
Vorsicht
Stromquellen • Dieses Gerät sollte nur über die auf dem Produkt angegebene
Stromquelle betrieben werden. Dieses Gerät wurde für eine Verwendung mit einer Hauptstromleitung mit einem geerdeten (neutralen) Leiter konzipiert. Der dritte Kontakt ist für einen Erdanschluß, und stellt eine Sicherheitsfunktion dar. Diese sollte nicht umgangen oder außer Betrieb gesetzt werden.
Stromunterbrechung • Um das Gerät auf sichere Weise vom Netz zu trennen, sollten
Sie alle Netzkabel aus der Rückseite des Gerätes, aus der externen Stomversorgung (falls dies möglich ist) oder aus der Wandsteckdose ziehen.
Schutz des Netzkabels • Netzkabel sollten stets so verlegt werden, daß sie nicht im
Weg liegen und niemand darauf treten kann oder Objekte darauf- oder unmittelbar dagegengestellt werden können.
Wartung • Alle Wartungsmaßnahmen sollten nur von qualifi ziertem Servicepersonal
durchgeführt werden. Die internen Komponenten des Gerätes sind wartungsfrei. Zur Vermeidung eines elektrischen Schocks versuchen Sie in keinem Fall, dieses Gerät selbst öffnen, da beim Entfernen der Abdeckungen die Gefahr eines elektrischen Schlags und/oder andere Gefahren bestehen.
Schlitze und Öffnungen • Wenn das Gerät Schlitze oder Löcher im Gehäuse aufweist,
dienen diese zur Vermeidung einer Überhitzung der empfi ndlichen Teile im Inneren. Diese Öffnungen dürfen niemals von anderen Objekten blockiert werden.
Litium-Batterie • Explosionsgefahr, falls die Batterie nicht richtig ersetzt
wird. Ersetzen Sie verbrauchte Batterien nur durch den gleichen oder einen vergleichbaren Batterietyp, der auch vom Hersteller empfohlen wird. Entsorgen Sie verbrauchte Batterien bitte gemäß den Herstelleranweisungen.
Este símbolo se utiliza para advertir al usuario sobre instrucciones importantes de operación y mantenimiento (o cambio de partes) que se desean destacar en el contenido de la documentación suministrada con los equipos.
Este símbolo se utiliza para advertir al usuario sobre la presencia de elementos con voltaje peligroso sin protección aislante, que puedan encontrarse dentro de la caja o alojamiento del producto, y que puedan representar riesgo de electrocución.
Precaucion
Leer las instrucciones • Leer y analizar todas las instrucciones de operación y
seguridad, antes de usar el equipo.
Conservar las instrucciones • Conservar las instrucciones de seguridad para
futura consulta.
Obedecer las advertencias • Todas las advertencias e instrucciones marcadas
en el equipo o en la documentación del usuario, deben ser obedecidas.
Evitar el uso de accesorios • No usar herramientas o accesorios que no
sean especifi camente recomendados por el fabricante, ya que podrian implicar riesgos.
Advertencia
Alimentación eléctrica • Este equipo debe conectarse únicamente a la fuente/tipo
de alimentación eléctrica indicada en el mismo. La alimentación eléctrica de este equipo debe provenir de un sistema de distribución general con conductor neutro a tierra. La tercera pata (puesta a tierra) es una medida de seguridad, no puentearia ni eliminaria.
Desconexión de alimentación eléctrica • Para desconectar con seguridad la acometida
de alimentación eléctrica al equipo, desenchufar todos los cables de alimentación en el panel trasero del equipo, o desenchufar el módulo de alimentación (si fuera independiente), o desenchufar el cable del receptáculo de la pared.
Protección del cables de alimentación • Los cables de alimentación eléctrica se deben
instalar en lugares donde no sean pisados ni apretados por objetos que se puedan apoyar sobre ellos.
Reparaciones/mantenimiento • Solicitar siempre los servicios técnicos de personal
califi cado. En el interior no hay partes a las que el usuario deba acceder. Para evitar riesgo de electrocución, no intentar personalmente la reparación/mantenimiento de este equipo, ya que al abrir o extraer las tapas puede quedar expuesto a voltajes peligrosos u otros riesgos.
Ranuras y aberturas • Si el equipo posee ranuras o orifi cios en su caja/alojamiento,
es para evitar el sobrecalientamiento de componentes internos sensibles. Estas aberturas nunca se deben obstruir con otros objetos.
Batería de litio • Existe riesgo de explosión si esta batería se coloca en la posición
incorrecta. Cambiar esta batería únicamente con el mismo tipo (o su equivalente) recomendado por el fabricante. Desachar las baterías usadas siguiendo las instrucciones del fabricante.
Instrucciones de seguridad • Español
Extron’s Warranty
Extron Electronics warrants this product against defects in materials and workmanship for a period of three years from the date of purchase. In the event of malfunction during the warranty period attributable directly to faulty workmanship and/or materials, Extron Electronics will, at its option, repair or replace said products or components, to whatever extent it shall deem necessary to restore said product to proper operating condition, provided that it is returned within the warranty period, with proof of purchase and description of malfunction to:
USA, Canada, South America, Europe, Africa, and the Middle East: and Central America:
Extron Electronics, Europe Extron Electronics Beeldschermweg 6C
1001 East Ball Road 3821 AH Amersfoort
Anaheim, CA 92805, USA The Netherlands
Asia: Japan:
Extron Electronics, Asia Extron Electronics, Japan 135 Joo Seng Road, #04-01 Kyodo Building PM Industrial Bldg. 16 Ichibancho Singapore 368363 Chiyoda-ku, Tokyo 102-0082 Japan
This Limited Warranty does not apply if the fault has been caused by misuse, improper handling care, electrical or mechanical abuse, abnormal operating conditions or non­Extron authorized modifi cation to the product.
If it has been determined that the product is defective, please call Extron and ask for an Applications Engineer at (714) 491-1500 (USA), 31.33.453.4040 (Europe), 65.6383.4400 (Asia), or 81.3.3511.7655 (Japan) to receive an RA# (Return Authorization number). This will begin the repair process as quickly as possible.
Units must be returned insured, with shipping charges prepaid. If not insured, you assume the risk of loss or damage during shipment. Returned units must include the serial number and a description of the problem, as well as the name of the person to contact in case there are any questions.
Extron Electronics makes no further warranties either expressed or implied with respect to the product and its quality, performance, merchantability, or fi tness for any particular use. In no event will Extron Electronics be liable for direct, indirect, or consequential damages resulting from any defect in this product even if Extron Electronics has been advised of such damage.
Please note that laws vary from state to state and country to country, and that some provisions of this warranty may not apply to you.
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201 Fax 07131 911203
ce-info@camboard.de
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201 Fax 07131 911203
ce-info@camboard.de
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201 Fax 07131 911203
ce-info@camboard.de
i
Cable Cubby® Products • Table of Contents
i
Table of Contents
Chapter 1 • Introduction ...........................................................1-1
About the Cable Cubby® Products ....................................... 1-2
Features ........................................................................................ 1-5
Chapter 2 • Installation ............................................................. 2-1
Installation Overview ............................................................... 2-2
Preparing the Routing Template .......................................... 2-3
Preparing the Table .................................................................. 2-4
Preparing the table with a router ........................................ 2-4
Preparing the table with a hole saw
(Cable Cubby 300C only) .......................................................2-6
Installing the Cables and AAPs ............................................. 2-7
AAP shelf brackets (CC 300, 600, and 800) ........................... 2-7
Installing the power module (CC 300, 600, and 800) .......... 2-8
Installing the cables ............................................................... 2-8
Installing the AAPs ................................................................. 2-9
Installing the shelf assembly (CC 300, 600, and 800) ........2-10
Adjusting the cable position (CC 200) ................................ 2-10
Mounting the Cable Cubby .................................................. 2-11
Chapter 3 • Maintenance and Modifications ............. 3-1
Removing and Replacing the Cable Cubby ....................... 3-2
Replacing Cables or an AAP ................................................... 3-5
Adding an Additional Power Module (CC 600 and CC 800)
................................................................. 3-6
Appendix A • Reference Information ..............................A-1
Specifications ..............................................................................A-2
Cable Cubby Part Numbers ....................................................A-7
Included Parts .............................................................................A-8
Replacement/Modification Part Numbers .........................A-9
Routing Template Part Numbers ........................................A-11
Top Plate Dimensions .............................................................A-11
Appendix B • Packaging for Shipment ........................... B-1
Chapter One • Introduction .................................................... 1-1
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201 Fax 07131 911203
ce-info@camboard.de
ii
Cable Cubby® Products • Table of Contents
Table of Contents, cont’d
All trademarks mentioned in this manual are the properties of their respective owners.
68-701-01 Rev. G
10 06
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201 Fax 07131 911203
ce-info@camboard.de
Cable Cubby® Products
1
Chapter One
Introduction
About the Cable Cubby® Products
Features
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201 Fax 07131 911203
ce-info@camboard.de
Cable Cubby® Products • Introduction
Introduction
1-2
About the Cable Cubby® Products
The Extron Cable Cubbies are furniture-mounted, architectural solutions for inconspicuous cable access and connection points. When cables are not in use, they can be stored out of the way while remaining connected to the presentation system.
Most US/domestic Cable Cubby models provide two unswitched USA AC power outlets. The US/domestic Cable Cubby 200 provides one outlet. Each of the international versions provides a single unswitched AC power outlet appropriate to the region where the Cable Cubby is sold. Several different types of power receptacles are available for the international version, including UK, French, Israeli, Australian, Indian, European, and Swiss receptacles.
The four different sizes of Cable Cubbies provide room for the indicated number of Extron’s Architectural Adapter Plates (AAPs):
Cable Cubby 800 USA/domestic model — Eight single­space (single-height) AAPs
Cable Cubby 800 (international model) — Seven single­space (single-height) AAPs
Cable Cubby 600 USA/domestic model — Six single­space AAPs
Cable Cubby 600 (international model) — Five single­space AAPs
Cable Cubby 300 USA/domestic model — Three single­space AAPs
Cable Cubby 300S — Square cover (figure 1-1)
Cable Cubby 300C — Circular (round) cover
Cable Cubby 300 (international model) — Two single­space AAPs
Cable Cubby 300S — Square cover
Cable Cubby 300C — Circular (round) cover
Cable Cubby 200 (all models) — Two single-space AAPs
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201 Fax 07131 911203
ce-info@camboard.de
Cable Cubby® Products • Introduction
1-3
Figure 1-1 — Cable Cubby 300S US/domestic enclosure
The AAP spaces inside the cubbies allow you to customize the enclosure to meet your unique needs, with the included split double space AAPs and Extron’s full line of optional passive AAPs. The split AAPs can store almost any type of cable you might encounter. The line of passive AAPs allows you to customize the AAP with almost any kind of pass-through connectivity you may need.
The elevation of the AAPs inside the cubby and the arrangement of the AAPs and the power outlets are adjustable to suit cable lengths and connector types.
N
The elevation and arrangement of the power outlet
and AAPs in the Cable Cubby 200 are fixed and not customizable.
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201 Fax 07131 911203
ce-info@camboard.de
Cable Cubby® Products • Introduction
Introduction, cont’d
1-4
The installed Cable Cubbies fit nearly flush within a table or podium top, storing the AAPs and cables out of the way and out of sight. To access the AAPs and connectors, lift the lid (figure 1-2). Half-moon cutouts in the lid allow you to run cables in or out and then close the lid. For Cable Cubby 300s, 600s, and 800s, you can lower the lid into its recessed position.
Mounted
through a table
or podium
Extron Cable Cubby 800
Hideaway Cable Access Enclosure
Audio Cable, Network Cable
15-pin HD Cable
Figure 1-2 — Typical Cable Cubby 800 application
The Cable Cubby 300 is available with either a round or a rectangular top. The other cubbies all have rectangular tops only. Preparing the table to install a Cable Cubby 300C (round) requires simply drilling a hole in the table with a 6-inch hole saw (figure 1-3). Preparing the table to install a square cubby requires routing a square hole in the table top. Sheet metal routing templates are available on request for all models at no cost.
1
2 3
Figure 1-3 — Cable Cubby 300C mounting
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201 Fax 07131 911203
ce-info@camboard.de
Cable Cubby® Products • Introduction
1-5
Features
Easy access to cables and AAPs
Durable mechanical movement
Cable Cubby 300, 600, and 800 available in a variety of surface finishes
Compact size
Flexible installation of Extron passive AAPs
Grounded AC receptacle(s)
UL/CUL listing
CSA certification
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201 Fax 07131 911203
ce-info@camboard.de
Cable Cubby® Products • Introduction
Introduction, cont’d
1-6
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201 Fax 07131 911203
ce-info@camboard.de
Cable Cubby® Products
2
Chapter Two
Installation
Installation Overview
Preparing the Routing Template
Preparing the Table
Installing the Cables and AAPs
Mounting
the Cable Cubby
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201 Fax 07131 911203
ce-info@camboard.de
Cable Cubby® Products • Installation
Installation
2-2
Installation Overview
Install and set up the Cable Cubby enclosures as follows:
1
If you plan to use a mounting template that has not been
prepared, prepare the template. See Preparing the Routing Template, later in this chapter.
2
Cut a hole in the surface where the enclosure will be
installed. See Preparing the Table, later in this chapter.
3
Run all cables necessary to support the AC connector,
the cables stored in the cubby, and all planned AAP connectors. Leave enough slack in the cables to connect or route them before the cubby is installed in the table.
4
If applicable, install the power module. If your location
requires electrical conduit, install an Extron flexible conduit kit. Refer to the Flexible Conduit Kit Installation Guide, Extron part #68-734-01.
5
Install all desired cables into the cable pass-through (split)
AAPs and install the AAPs into the Cable Cubby. See Installing the Cables and AAPs, later in this chapter.
6
If applicable, connect cables to the rear connectors on
the passive AAPs and install the AAPs in the cubby. See Installing the AAPs, later in this chapter.
7
Mount the Cable Cubby in the table. See Mounting the
Cable Cubby, later in this chapter.
8
Peel the protective film from the top surface.
9
Connect the Cable Cubby power cord.
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201 Fax 07131 911203
ce-info@camboard.de
Cable Cubby® Products • Installation
2-3
Preparing the Routing Template
Extron provides metal templates for the Cable Cubbies at no charge. See Routing Template Part Numbers, in appendix A, Reference Information, for part numbers. Extron recommends using this template as a guide to cut the hole in the table where the cubby will be installed.
N
The metal routing template is reusable. Do not discard
this template when the installation is complete. Save it for installing Cable Cubby models of the same size.
1. Cut 1/2" x 4" strips of soft, finished lumber at least
long enough to span the distance between the desired installation location on the mounting surface and the edges of the mounting surface (figure 2-1).
These strips raise the routing template above the mounting
surface to provide room for the router’s collar, protect the mounting surface, and extend the routing template’s reach so that it can be clamped to the edge of the surface.
Mounting Surface Edge
Mounting Surface Edge
Wood Thickness
0.5" / 1.3 cm
Width of Mounting Surf
ace
Routing Template
Wood Strip Height 4" / 10.2 cm
Minimum 4 Screws
Wood Strips
Figure 2-1 — Prepared CC 300 mounting template
2. Using four or more short wood screws, secure the
mounting template to the lumber strips.
C
Do not allow the wood screws to protrude through
the bottom of the wooden strips. Protruding screws will mar the table when the template is used.
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201 Fax 07131 911203
ce-info@camboard.de
Cable Cubby® Products • Installation
Installation, cont’d
2-4
Preparing the Table
The preferred and recommended method for preparing the table for square Cable Cubbies and one of two preferred methods for the Cable Cubby 300C is to use the appropriate Extron routing template and a router.
For the Cable Cubby 300C, another preferred method is to use a 6" hole saw.
C
The opening in the table for the Cable Cubby should
be cut only by licensed and bonded craftspeople. Exercise care to prevent scarring or damaging the furniture.
The surfaces of the Cable Cubby enclosure have screws and other protruding hardware that could damage fine furniture. Do not rest the enclosure on unprotected furniture.
Alternatively, for any model, you can use a paper cut-out template (see appendix A) and a sabre saw or keyhole saw; but this method is not recommended.
Preparing the table with a router
Prepare the table with a router as follows:
C
The routing templates for the various Cable Cubbies
are not interchangeable. If you use the wrong template, you will cut an improperly-sized hole. If you use a larger template than required, the cut will result in gaps in the table surface on either side of the enclosure.
C
Ensure that only the wooden strips on the routing
template contact the furniture. Failure to do so may mar the furniture.
N
The metal routing template is reusable. Do not discard
the template when the installation is complete. Save it for installing other Cable Cubbies of the same size.
1. Mark the desired mounting location on the tabletop or other installation surface.
2. Place the mounting template assembly on the table, centered on the mounting location. Angle the template for the optimum positioning. If necessary, use a square to ensure that the template is properly positioned. Extron is not responsible for improperly positioned Cable Cubbies.
3. Once the template assembly is positioned properly, secure the assembly to the table with C-clamps.
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201 Fax 07131 911203
ce-info@camboard.de
Cable Cubby® Products • Installation
2-5
W
Wear safety glasses when operating the router.
Failure to comply can result in eye injury.
4. Using a router with a 5/8" (or 16 mm) outside diameter guide bushing and a 1/2" (or 12 mm or 12.7 mm) diameter straight router bit, carefully cut the opening in the surface (figure 2-2).
Figure 2-2 — Cutting the opening with a router
5. Remove the C-clamps and the routing template.
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201 Fax 07131 911203
ce-info@camboard.de
Cable Cubby® Products • Installation
Installation, cont’d
2-6
Preparing the table with a hole saw (Cable Cubby 300C only)
Prepare the table with a hole saw as follows:
1. On the tabletop or other installation surface, mark the 6" circle, then find and mark the center of the circle.
W
Wear safety glasses when operating the drill.
Failure to comply can result in eye injury.
2. Using a portable drill with a 6" (or 152 mm) hole saw, carefully cut the opening in the table surface at the desired location (figure 2-3). Extron is not responsible for improperly positioned Cable Cubbies.
C
Use a portable drill with sufficient power to handle
the 6” hole saw. Exercise caution when handling the drill and hole saw. Take care to protect the mounting surface from damage.
Figure 2-3 — Cutting the opening with a hole saw
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201 Fax 07131 911203
ce-info@camboard.de
Cable Cubby® Products • Installation
2-7
Installing the Cables and AAPs
Each Cable Cubby 300, 600, and 800 model ships with one or two moveable AAP shelf assemblies. The Cable Cubby 200’s AAP shelf is fixed in place.
AAP shelf brackets (CC 300, 600, and 800)
Each shipped AAP shelf assembly consists of a set of shelf brackets and a number of cable pass-through (split) AAPs. Depending on the Cable Cubby model, each set of shelf brackets supports either two, three, or four single-space AAPs (figure 2-4).
Four-Space Shelf Bracket
and Split AAPs
Three-Space Shelf Bracket
and Split AAPs
Two-Space Shelf Bracket
and Split AAPs
Figure 2-4 — Shelf brackets
The simplest way to install the cables and AAPs in the Cable Cubby 300, 600, and 800 is to populate the shelf brackets with split and/or standard AAPs outside the cubby and then install the populated AAP shelf assembly into the cubby.
N
Cable cubby 300, 600, and 800 only —
On US/domestic models, the power module takes up two AAP spaces. On IEC, EU, Swiss, UK, Israeli, and Australian models, the power module takes up three AAP spaces. Cable pass-through AAPs take two, three, or four AAP spaces. Consider the arrangement of the Cable Cubby AAPs when you install them so that you do not waste AAP space.